    Evaluation of a generalized knowledge-based planning performance for VMAT irradiation of breast and locoregional lymph nodes—Internal mammary and/or supraclavicular regions

    by Maria Rago, Lorenzo Placidi, Mattia Polsoni, Giulia Rambaldi, Davide Cusumano, Francesca Greco, Luca Indovina, Sebastiano Menna, Elisa Placidi, Gerardina Stimato, et al.

    Purpose: To evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions. Methods and materials: Six RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure. Five more models, twins of the previous models, have been created without the need of these structures. Results: All models were successfully validated on an independent cohort of 40 patients, 30 from the same institute that provided the training patients and 10 from an additional institute, with the resulting plans being of equal or better quality compared with the clinical plans. The internal validation shows that the models reduce the heart maximum dose of about 2 Gy, the mean dose of about 1 Gy and the V20Gy of 1.5 Gy on average. Model R and L together with model B without optimization structures ensured the best outcomes in the 20% of the values compared to other models. The external validation observed an average improvement of at least 16% for the V5Gy of lungs in RP plans. The mean heart dose and for the V20Gy for lung IPSI were almost halved. The models reduce the maximum dose for the spinal canal of more than 2 Gy on average Conclusions: All KB models allow a homogeneous plan quality and some dosimetric gains, as we saw in both internal and external validation. Sub-KB models, developed by splitting right and left breast cases or including only whole breast with locoregional lymph nodes, have shown good performances, comparable but slightly worse than the general model. Finally, models generated without the optimization structures, performed better than the original ones.


  • Open Access

    Characterization of an inorganic scintillator for small‐field dosimetry in MR‐guided radiotherapy

    by Davide Cusumano, Lorenzo Placidi, Emiliano D'Agostino, Luca Boldrini, Sebastiano Menna, Vincenzo Valentini, Marco De Spirito, Luigi Azario

    Introduction Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B). Methods The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, angular response, and dependence by energy, field size, and B orientation using a 6 MV magnetic resonance (MR)-Linac and a water tank. Field size dependence was investigated by measuring the output factor (OF) at 1.5 cm. The results were compared with those measured using other detectors (ion chamber and synthetic diamond) and those calculated using a Monte Carlo (MC) algorithm. Energy dependence was investigated by acquiring a percentage depth dose (PDD) curve at two field sizes (3.32 x 3.32 and 9.96 x 9.96 cm(2)) and repeating the OF measurements at 5 and 10 cm depths. Results The mean SNR was 116.3 +/- 0.6. Detector repeatability was within 1%, angular dependence was <2% and its response variation based on the orientation with respect to the B lines was <1%. The detector has a temporal resolution of 10 Hz and it showed a linear response (R-2 = 1) in the dose range investigated. All the OF values measured at 1.5 cm depth using the scintillator are in accordance within 1% with those measured with other detectors and are calculated using the MC algorithm. PDD values are in accordance with MC algorithm only for 3.32 x 3.32 cm(2)field. Numerical models can be applied to compensate for energy dependence in case of larger fields. Conclusion The inorganic scintillator in the present form can represent a valuable detector for small-field dosimetry and periodic quality controls at MR-Linacs such as dose stability, OFs, and dose linearity. In particular, the detector can be effectively used for small-field dosimetry at 1.5 cm depth and for PDD measurements if the field dimension of 3.32 x 3.32 cm(2)is not exceeded.


  • Open Access

    A field strength independent MR radiomics model to predict pathological complete response in locally advanced rectal cancer

    by Davide Cusumano, Gert Meijer, Jacopo Lenkowicz, Giuditta Chiloiro, Luca Boldrini, Carlotta Masciocchi, Nicola Dinapoli, Roberto Gatta, Calogero Casà, Andrea Damiani, et al.

    Purpose: Aim of this study was to develop a generalised radiomics model for predicting pathological complete response after neoadjuvant chemo-radiotherapy in locally advanced rectal cancer patients using pre-CRT T2-weighted images acquired at a 1.5 T and a 3 T scanner. Methods: In two institutions, 195 patients were scanned: 136 patients were scanned on a 1.5 T MR scanner, 59 patients on a 3 T MR scanner. Gross tumour volumes were delineated on the MR images and 496 radiomic features were extracted, applying the intensity-based (IB) filter. Features were standardised with Z-score normalisation and an initial feature selection was carried out using Wilcoxon–Mann–Whitney test: The most significant features at 1.5 T and 3 T were selected as main features. Several logistic regression models combining the main features with a third one selected by those resulting significant were elaborated and evaluated in terms of area under curve (AUC). A tenfold cross-validation was repeated 300 times to evaluate the model robustness. Results: Three features were selected: maximum fractal dimension with IB = 0–50, energy and grey-level non-uniformity calculated on the run-length matrix with IB = 0–50. The AUC of the model applied to the whole dataset after cross-validation was 0.72, while values of 0.70 and 0.83 were obtained when 1.5 T and 3 T patients were considered, respectively. Conclusions: The model elaborated showed good performance, even when data from patients scanned on 1.5 T and 3 T were merged. This shows that magnetic field intensity variability can be overcome by means of selecting appropriate image features.


  • Open Access

    Evaluation of a simplified optimizer for MR‐guided adaptive RT in case of pancreatic cancer

    by Davide Cusumano, Luca Boldrini, Sebastiano Menna, Stefania Teodoli, Elisa Placidi, Giuditta Chiloiro, Lorenzo Placidi, Francesca Greco, Gerardina Stimato, Francesco Cellini, et al.

    Purpose: Magnetic resonance‐guided adaptive radiotherapy (MRgART) is considered a promising resource for pancreatic cancer, as it allows to online modify the dose distribution according to daily anatomy. This study aims to compare the dosimetric performance of a simplified optimizer implemented on a MR‐Linac treatment planning system (TPS) with those obtained using an advanced optimizer implemented on a conventional Linac.Methods: Twenty patients affected by locally advanced pancreatic cancer (LAPC) were considered. Gross tumor volume (GTV) and surrounding organ at risks (OARs) were contoured on the average 4DCT scan. Planning target volume was generated from GTV by adding an isotropic 3 mm margin and excluding overlap areas with OARs.Treatment plans were generated by using the simple optimizer for the MR‐Linac in intensity‐modulated radiation therapy (IMRT) and the advanced optimizer for conventional Linac in IMRT and volumetric modulated arc therapy (VMAT) technique. Prescription dose was 40 Gy in five fractions. The dosimetric comparison was performed on target coverage, dosimetric indicators, and low dose diffusion.Results: The simplified optimizer of MR‐Linac generated clinically acceptable plans in 80% and optimal plans in 55% of cases. The number of clinically acceptable plans obtained using the advanced optimizer of the conventional Linac with IMRT was the same of MR‐Linac, but the percentage of optimal plans was higher (65%). Using the VMAT technique, it is possible to obtain clinically acceptable plan in 95% and optimal plans in 90% of cases.The advanced optimizer combined with VMAT technique ensures higher target dose homogeneity and minor diffusion of low doses, but its actual optimization time is not suitable for MRgART.Conclusion: Simplified optimization solutions implemented in the MR‐Linac TPS allows to elaborate in most of cases treatment plans dosimetrically comparable with those obtained by using an advanced optimizer. A superior treatment plan quality is possible using the VMAT technique that could represent a breakthrough for the MRgART if the modern advancements will lead to shorter optimization times.


  • Open Access

    A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case

    by Mariangela Massaccesi, Davide Cusumano, Luca Boldrini, Nicola Dinapoli, Bruno Fionda, Stefania Teodoli, Luigi Azario, Gian Carlo Mattiucci, Mario Balducci, Francesco Cellini, et al.

    The case of a 50‐year‐old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri‐60‐Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery and a respiratory gating protocol was applied for the different breathing phases (Free Breathing, Deep Inspiration Breath Hold and Final Expiration Breath Hold). Three intensity modulated radiation therapy (IMRT) plans were calculated and Final Expiration Breath Hold plan was finally selected due to the absence of PTV coverage differences and better organs at risk sparing (i.e. kidneys). This case report suggests that organs at risk avoidance with MRI‐guided respiratory‐gated Radiotherapy is feasible and particularly advantageous whenever sparing the organs at risk is of utmost dosimetric or clinical importance.


  • Open Access

    Online adaptive magnetic resonance guided radiotherapy for pancreatic cancer: state of the art, pearls and pitfalls

    by Luca Boldrini, Davide Cusumano, Francesco Cellini, Luigi Azario, Gian Carlo Mattiucci, Vincenzo Valentini

    Different studies have proved in recent years that hypofractionated radiotherapy (RT) improves overall survival of patients affected by locally advanced, unresectable, pancreatic cancer. The clinical management of these patients generally leads to poor results and is considered very challenging, due to different factors, heavily influencing treatment delivery and its outcomes. Firstly, the dose prescribed to the target is limited by the toxicity that the highly radio-sensitive organs at risk (OARs) surrounding the disease can develop. Treatment delivery is also complicated by the significant inter-fractional and intra-fractional variability of therapy volumes, mainly related to the presence of hollow organs and to the breathing cycle. The recent introduction of magnetic resonance guided radiotherapy (MRgRT) systems leads to the opportunity to control most of the aforementioned sources of uncertainty influencing RT treatment workflow in pancreatic cancer. MRgRT offers the possibility to accurately identify radiotherapy volumes, thanks to the high soft-tissue contrast provided by the Magnetic Resonance imaging (MRI), and to monitor the tumour and OARs positions during the treatment fraction using a high-temporal cine MRI. However, the main advantage offered by the MRgRT is the possibility to online adapt the RT treatment plan, changing the dose distribution while the patient is still on couch and successfully addressing most of the sources of variability. Aim of this study is to present and discuss the state of the art, the main pitfalls and the innovative opportunities offered by online adaptive MRgRT in pancreatic cancer treatment.


  • Open Access

    Personalized re-treatment strategy for uveal melanoma local recurrences after interventional radiotherapy (brachytherapy): single institution experience and systematic literature review

    by Luca Tagliaferri, Monica Maria Pagliara, Bruno Fionda, Andrea Scupola, Luigi Azario, Maria Grazia Sammarco, Rosa Autorino, Valentina Lancellotta, Silvia Cammelli, Carmela Grazia Caputo, et al.

    Purpose To report the results of a patient’s tailored therapeutic approach using a second course of interventional radiotherapy (brachytherapy) in patients with locally recurrent uveal melanoma. Material and methods Patients who had already undergone ocular brachytherapy treated at our...


  • Predicting tumour motion during the whole radiotherapy treatment: a systematic approach for thoracic and abdominal lesions based on real time MR

    by Davide Cusumano, Jennifer Dhont, Luca Boldrini, Giuditta Chiloiro, Stefania Teodoli, Mariangela Massaccesi, Bruno Fionda, Francesco Cellini, Luigi Azario, Jef Vandemeulebroucke, et al.


  • Open Access

    Delta radiomics for rectal cancer response prediction with hybrid 0.35 T magnetic resonance-guided radiotherapy (MRgRT): a hypothesis-generating study for an innovative personalized medicine approach

    by Luca Boldrini, Davide Cusumano, Giuditta Chiloiro, Calogero Casà, Carlotta Masciocchi, Jacopo Lenkowicz, Francesco Cellini, Nicola Dinapoli, Luigi Azario, Stefania Teodoli, et al.

    The aim of this study was to evaluate the variation of radiomics features, defined as “delta radiomics”, in patients undergoing neoadjuvant radiochemotherapy (RCT) for rectal cancer treated with hybrid magnetic resonance (MR)-guided radiotherapy (MRgRT). The delta radiomics features were then correlated with clinical complete response (cCR) outcome, to investigate their predictive power. A total of 16 patients were enrolled, and 5 patients (31%) showed cCR at restaging examinations. T2*/T1 MR images acquired with a hybrid 0.35 T MRgRT unit were considered for this analysis. An imaging acquisition protocol of 6 MR scans per patient was performed: the first MR was acquired at first simulation (t0) and the remaining ones at fractions 5, 10, 15, 20 and 25. Radiomics features were extracted from the gross tumour volume (GTV), and each feature was correlated with the corresponding delivered dose. The variations of each feature during treatment were quantified, and the ratio between the values calculated at different dose levels and the one extracted at t0 was calculated too. The Wilcoxon–Mann–Whitney test was performed to identify the features whose variation can be predictive of cCR, assessed with a MR acquired 6 weeks after RCT and digital examination. The most predictive feature ratios in cCR prediction were the L_least and glnu ones, calculated at the second week of treatment (22 Gy) with a p value = 0.001. Delta radiomics approach showed promising results and the quantitative analysis of images throughout MRgRT treatment can successfully predict cCR offering an innovative personalized medicine approach to rectal cancer treatment.


  • Experimental evaluation of the impact of low tesla transverse magnetic field on dose distribution in presence of tissue interfaces

    by Davide Cusumano, Stefania Teodoli, Francesca Greco, Andrea Fidanzio, Luca Boldrini, Mariangela Massaccesi, Francesco Cellini, Vincenzo Valentini, Luigi Azario, Marco De Spirito