Anand Viswanathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anand Viswanathan has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Bradford J. Wood
Center for Interventional Oncology, NCI, NIH, Bethesda, MD, USA
8 shared publications Neil Glossop
4 shared publicationsGabor Fichtinger
Johns Hopkins Univ. (USA)
3 shared publicationsKevin Cleary
Georgetown Univ. Medical Ctr
3 shared publicationsDavid Lindisch
Georgetown Univ. Medical Ctr
2 shared publicationsEmad M. Boctor
Johns Hopkins Univ. (USA)
2 shared publications
Latest Publications
- 3 September 2020
- Published by American Society for Engineering Education
- p. 7.1044.1-7.1044.13
Surgical Robot Competition Introducing Engineering In Medicine To Pre College Students
Main Menu Session 2793 Surgical Robot Competition – Introducing Engineering in Medicine to Pre-college Students Oleg Gerovichev, Randal P. Goldberg, Ian D. Donn, Anand Viswanathan, Russell H. Taylor Department of Biomedical Engineering / Department of Mechanical Engineering / Department of Electrical and Computer Engineering/ Department of Computer Science/ Department of Computer Science Johns Hopkins University (Baltimore, Maryland) Abstract Robotics is a multidisciplinary field that holds great potential for hands-on education throughout a student’s school career. However, making technology accessible for learning is challenging due to cost, safety and implementation concerns. This paper describes a method for drawing on current, real life challenges faced by researchers in the field and translating such experiences into a secondary school level program. The concept of the competition, application of LEGO Mindstorms® robotics platform, methods of organization and expansion, past experiences and future plans are presented. Our goal is to show an example of how to integrate off-the-shelf robotic technology with current real-world engineering challenges and to engage students in the fields of engineering, robotics, and medicine in a fun and exciting atmosphere. Introduction and Background Modern medical practice relies on innovation and technology to provide better solutions in the operating room. Doctors, scientists and engineers work together to improve current surgical care by designing tools and machines to overcome human limitations, namely precision, control, reliability, patience and memory. Computers and robots do not have these restrictions. Computers have had such an impact on surgery that many current procedures would be impossible or significantly more difficult without them. Computers aid surgeons by displaying images of internal organs through computed tomography (CT) and magnetic resonance imaging (MRI) or exposing brain function through electroencephalographic analysis. Robots can function as surgical assistants [1] or even substitute for the surgeon on location (e.g. telesurgery). Robotics is a popular tool for science and engineering education on various levels because of its multidisciplinary nature. The development of a successful robot incorporates knowledge from a variety of disciplines such as physics, math, mechanical engineering, materials science, electrical engineering, and computer science as well as a variety of skills gained through practical experience. There is also a need for equipment: raw building materials and shop tools, wires and a soldering iron, a variety of computers and, often, complicated programming interfaces. A complete engineering education is founded on the acquisition of these skills, yet the time and “Proceedings of the 2002 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2002, American Society for Engineering Education” Main Menu
- 3 September 2020
- Published by American Society for Engineering Education
- p. 7.1044.1-7.1044.13
Surgical Robot Competition Introducing Engineering In Medicine To Pre College Students
Main Menu Session 2793 Surgical Robot Competition – Introducing Engineering in Medicine to Pre-college Students Oleg Gerovichev, Randal P. Goldberg, Ian D. Donn, Anand Viswanathan, Russell H. Taylor Department of Biomedical Engineering / Department of Mechanical Engineering / Department of Electrical and Computer Engineering/ Department of Computer Science/ Department of Computer Science Johns Hopkins University (Baltimore, Maryland) Abstract Robotics is a multidisciplinary field that holds great potential for hands-on education throughout a student’s school career. However, making technology accessible for learning is challenging due to cost, safety and implementation concerns. This paper describes a method for drawing on current, real life challenges faced by researchers in the field and translating such experiences into a secondary school level program. The concept of the competition, application of LEGO Mindstorms® robotics platform, methods of organization and expansion, past experiences and future plans are presented. Our goal is to show an example of how to integrate off-the-shelf robotic technology with current real-world engineering challenges and to engage students in the fields of engineering, robotics, and medicine in a fun and exciting atmosphere. Introduction and Background Modern medical practice relies on innovation and technology to provide better solutions in the operating room. Doctors, scientists and engineers work together to improve current surgical care by designing tools and machines to overcome human limitations, namely precision, control, reliability, patience and memory. Computers and robots do not have these restrictions. Computers have had such an impact on surgery that many current procedures would be impossible or significantly more difficult without them. Computers aid surgeons by displaying images of internal organs through computed tomography (CT) and magnetic resonance imaging (MRI) or exposing brain function through electroencephalographic analysis. Robots can function as surgical assistants [1] or even substitute for the surgeon on location (e.g. telesurgery). Robotics is a popular tool for science and engineering education on various levels because of its multidisciplinary nature. The development of a successful robot incorporates knowledge from a variety of disciplines such as physics, math, mechanical engineering, materials science, electrical engineering, and computer science as well as a variety of skills gained through practical experience. There is also a need for equipment: raw building materials and shop tools, wires and a soldering iron, a variety of computers and, often, complicated programming interfaces. A complete engineering education is founded on the acquisition of these skills, yet the time and “Proceedings of the 2002 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2002, American Society for Engineering Education” Main Menu
- 28 February 2010
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 21 (2) , S46-S47
Abstract No. 118: A comparison of methods for tracking RFA probes and sensitivity to RF field and temperature
- 28 February 2010
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 21 (2) , S46-S47
Abstract No. 118: A comparison of methods for tracking RFA probes and sensitivity to RF field and temperature
- 1 September 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (9) , 1141-1150
Electromagnetic Tracking for Thermal Ablation and Biopsy Guidance: Clinical Evaluation of Spatial Accuracy
- 1 September 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (9) , 1141-1150
Electromagnetic Tracking for Thermal Ablation and Biopsy Guidance: Clinical Evaluation of Spatial Accuracy
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6509, 65092
Precision instrument placement using a 4-DOF robot with integrated fiducials for minimally invasive interventions
Minimally invasive procedures are increasingly attractive to patients and medical personnel because they can reduce operative trauma, recovery times, and overall costs. However, during these procedures, the physician has a very limited view of the interventional field and the exact position of surgical instruments. We present an image-guided platform for precision placement of surgical instruments based upon a small four degree-of-freedom robot (B-RobII; ARC Seibersdorf Research GmbH, Vienna, Austria). This platform includes a custom instrument guide with an integrated spiral fiducial pattern as the robot's end-effector, and it uses intra-operative computed tomography (CT) to register the robot to the patient directly before the intervention. The physician can then use a graphical user interface (GUI) to select a path for percutaneous access, and the robot will automatically align the instrument guide along this path. Potential anatomical targets include the liver, kidney, prostate, and spine. This paper describes the robotic platform, workflow, software, and algorithms used by the system. To demonstrate the algorithmic accuracy and suitability of the custom instrument guide, we also present results from experiments as well as estimates of the maximum error between target and instrument tip.© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6509, 65092
Precision instrument placement using a 4-DOF robot with integrated fiducials for minimally invasive interventions
Minimally invasive procedures are increasingly attractive to patients and medical personnel because they can reduce operative trauma, recovery times, and overall costs. However, during these procedures, the physician has a very limited view of the interventional field and the exact position of surgical instruments. We present an image-guided platform for precision placement of surgical instruments based upon a small four degree-of-freedom robot (B-RobII; ARC Seibersdorf Research GmbH, Vienna, Austria). This platform includes a custom instrument guide with an integrated spiral fiducial pattern as the robot's end-effector, and it uses intra-operative computed tomography (CT) to register the robot to the patient directly before the intervention. The physician can then use a graphical user interface (GUI) to select a path for percutaneous access, and the robot will automatically align the instrument guide along this path. Potential anatomical targets include the liver, kidney, prostate, and spine. This paper describes the robotic platform, workflow, software, and algorithms used by the system. To demonstrate the algorithmic accuracy and suitability of the custom instrument guide, we also present results from experiments as well as estimates of the maximum error between target and instrument tip.© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
- 1 January 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (1) , 9-24
Technologies for Guidance of Radiofrequency Ablation in the Multimodality Interventional Suite of the Future
- 1 January 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (1) , 9-24
Technologies for Guidance of Radiofrequency Ablation in the Multimodality Interventional Suite of the Future
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 10 (3) , 490-496
Radio Frequency Ablation Registration, Segmentation, and Fusion Tool
The radio frequency ablation segmentation tool (RFAST) is a software application developed using NIH's medical image processing analysis and visualization (MIPAV) API for the specific purpose of assisting physicians in the planning of radio frequency ablation (RFA) procedures. The RFAST application sequentially leads the physician through the steps necessary to register, fuse, segment, visualize and plan the RFA treatment. Three-dimensional volume visualization of the CT dataset with segmented 3D surface models enables the physician to interactively position the ablation probe to simulate burns and to semi-manually simulate sphere packing in an attempt to optimize probe placement.
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 10 (3) , 490-496
Radio Frequency Ablation Registration, Segmentation, and Fusion Tool
The radio frequency ablation segmentation tool (RFAST) is a software application developed using NIH's medical image processing analysis and visualization (MIPAV) API for the specific purpose of assisting physicians in the planning of radio frequency ablation (RFA) procedures. The RFAST application sequentially leads the physician through the steps necessary to register, fuse, segment, visualize and plan the RFA treatment. Three-dimensional volume visualization of the CT dataset with segmented 3D surface models enables the physician to interactively position the ablation probe to simulate burns and to semi-manually simulate sphere packing in an attempt to optimize probe placement.
- Open Access
- 1 May 2006
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 11 (3) , 119-125
Respiratory motion compensation with tracked internal and external sensors during CT-guided procedures
This paper investigates the possibility of using the motion of a patient's anterior surface in combination with a motion model to compensate for internal respiratory motion during tracked biopsies. Position data from two electromagnetically tracked sensors, one placed on the patient's sternum, the other incorporated into a biopsy needle, were acquired during a liver biopsy. The data were used to evaluate the correlation between the position measurements of the two sensors and to derive an affine motion model to assess respiratory motion compensation for image-guided interventional procedures. The correlation reached up to 94% for ranges of steady respiration. The residual motion of the internal sensor after compensation is reduced by a factor of approximately four.
- 1 May 2006
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 11 (3) , 119-125
Open AccessRespiratory motion compensation with tracked internal and external sensors during CT-guided procedures
This paper investigates the possibility of using the motion of a patient's anterior surface in combination with a motion model to compensate for internal respiratory motion during tracked biopsies. Position data from two electromagnetically tracked sensors, one placed on the patient's sternum, the other incorporated into a biopsy needle, were acquired during a liver biopsy. The data were used to evaluate the correlation between the position measurements of the two sensors and to derive an affine motion model to assess respiratory motion compensation for image-guided interventional procedures. The correlation reached up to 94% for ranges of steady respiration. The residual motion of the internal sensor after compensation is reduced by a factor of approximately four.
- 1 January 2006
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 829 (1) , 122-126
CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)
To demonstrate the feasibility of CT and B‐mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non‐thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position‐sensing arm and an active six degree‐of‐freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2–4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre‐clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre‐clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non‐enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre‐clinical models may be translated to large animals and humans for HIFU‐induced ablation and drug delivery. Integrated CT‐guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real‐time.
- 1 January 2006
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 829 (1) , 122-126
CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)
To demonstrate the feasibility of CT and B‐mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non‐thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position‐sensing arm and an active six degree‐of‐freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2–4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre‐clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre‐clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non‐enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre‐clinical models may be translated to large animals and humans for HIFU‐induced ablation and drug delivery. Integrated CT‐guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real‐time.
- 1 May 2005
- Published by Elsevier in International Congress Series
- Vol. 1281, 746-751
An electro-magnetically tracked laparoscopic ultrasound for multi-modality minimally invasive surgery
- 1 May 2005
- Published by Elsevier in International Congress Series
- Vol. 1281, 746-751
An electro-magnetically tracked laparoscopic ultrasound for multi-modality minimally invasive surgery
- 12 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 527-530
A novel closed form solution for ultrasound calibration
- 12 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 527-530
A novel closed form solution for ultrasound calibration