AMAntonia Morabito

Antonia Morabito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Antonia Morabito has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spectral study of the lateral trace-space of laser-driven proton beams

    by C. Salgado-López, I. Rodríguez-Pérez, J. I. Apiñaniz, A. Curcio, T. Cebriano, A. Morabito, L. Volpe, G. Gatti

    The characterization of the phase space of laser-driven proton beams—particularly across a broad energy spectrum—in spite of the recent interest in laser-driven particle accelerators, remains a significant challenge due to the complex interplay between transverse dynamics and spectral properties. This work presents a detailed spectral study of the lateral emittance of laser-driven proton beams, providing energy-resolved, single-shot measurements of the beam emittance by means of a magnetically streaked pepper-pot method. Experimental results from a laser-driven proton source demonstrate the ability to resolve the beam’s transverse trace space at various proton energies, yielding precise emittance estimations and highlighting the variation of beam quality with energy. The study emphasizes the necessity of high spectral resolution for accurate emittance characterization. The findings offer valuable implications for optimizing beamline design and improving the performance of future tabletop laser accelerators.

  • Addressing the role of advanced targets for enhanced control of laser-driven hadron sources

    by Francesco Mirani, Kevin Ambrogioni, Alessandro Maffini, Francesco Gatti, Maria Sole Galli De Magistris, Marta Galbiati, Davide Vavassori, Davide Orecchia, Dario Rastelli, Davide Mazzucconi, et al.


  • Open Access

    Design of a Semiconductor-Based Proton Spectrometer for Laser-Driven Sources Applications

    by Francesco Gatti, Francesco Mirani, Dario Rastelli, Davide Mazzucconi, José Luis Henares, Antonia Morabito, Andrea Pola, Matteo Passoni

    Laser-driven proton sources are attracting increasing interest because of their promising uses in several fields, from basic science to materials analysis. Applications require quantitative and accurate measurements of the laser-driven particle spectra. However, the peculiar features of these sources pose several challenges to their in-depth characterization. In this work, we present the design of a spectrometer based on silicon photodiodes, focusing on TW-class laser proton sources and their foreseen applications. The device comprises a dipole magnet to deflect the ions along different trajectories according to their energies. The magnet can also be removed to avoid beam deflection and make the particles available for applications. We exploit a finely shaped differential filter to cut the contribution of unwanted heavy ions and a photodiode array for proton detection. These elements are described and experimentally characterized, allowing the development of an analytical description useful to size the instrument. We perform Monte Carlo simulations to validate the model and calibrate the system. The retrieved data are used to simulate the detection of protons in a typical laser-driven particle acceleration experiment. The spectrum reconstructed by Monte Carlo simulations wellmatches the distribution provided as source, demonstrating the founding principles of the spectrometer. Lastly, a first test in a real laser environment at Centro de Láseres Pulsados (1 PW VEGA-3 laser) is also presented, showing the full response of the device and its potential as a laser-driven proton beam monitor in application-oriented scenarios.


  • Open Access

    Novel Spectrometer Designs for Laser-Driven Ion Acceleration

    by Antonia Morabito, Kwinten Nelissen, Mauro Migliorati, Sargis Ter-Avetisyan

    We propose novel spectrometer designs that aim to enhance the measured spectral range of ions on a finite-sized detector. In contrast to the traditional devices that use a uniform magnetic field, in which the deflection of particles increases inversely proportional to their momentum, in a gradient magnetic field, the deflection of particles will decrease due to the reduction of the magnetic field along their propagation. In this way, low-energy ions can reach the detector because they are deflected less, compared to the uniform field case. By utilizing a gradient magnetic field, the non-linear dispersion of ions in a homogeneous magnetic field approaches nearly linear dispersion behavior. Nonetheless, the dispersion of low-energy ions, using a dipole field, remains unnecessarily high. In this article, we discuss the employed methodology and present simulation results of the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy (energy dynamic range) and energy resolution.

  • Open Access

    Novel Spectrometer Designs for Laser Driven Ion Acceleration

    by Antonia Morabito, Kwinten Nelissen, Mauro Migliorati, Sargis Ter-Avetisyan

    We propose novel spectrometer designs that aim to enhance the measured spectral range 1 of ions on a finite-sized detector. In contrast to the traditional devices that use uniform magnetic 2 field, in which the deflection of particles increases inversely proportional to their momentum, in a 3 gradient magnetic field, the deflection of particles will be decreased due to the reduction of the 4 magnetic field along their propagation. Low energy ions are particularly impacted, as they are 5 deflected less and are more likely to reach the detector compared to being driven out of it while 6 using a uniform magnetic field. By the means of a gradient magnetic field, the nonlinear dispersion 7 of ions in a homogeneous magnetic field can approach a nearly linear dispersion. Nonetheless, 8 the dispersion of low energy ions in a homogeneous magnetic field remains unnecessarily high. 9 In this article, we explore linear, quadratic, and higher-order field profiles in comparison to the 10 homogeneous field case. We discuss the employed methodology and present simulation results of 11 the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy 12 (energy dynamic range) and energy resolution

  • Open Access

    Liouville Theory for Fully Analytic Studies of Transverse Beam Dynamics in Laser-Plasma Ion Accelerators

    by Alessandro Curcio, Jon Imanol Apiñaniz Aginako, Teresa Cebriano Ramírez, Michael Ehret, Berkahoum Kebladj, Antonia Morabito, Alberto Pérez Delgado, Carlos Salgado López, Luca Volpe, Giancarlo Gatti

    The exact solution of the Liouville equation expressed in terms of exponential operators can describe the phase space evolution of particle beams in transport lines. In this paper, we generalize the solution of the above equation for the case of beam losses induced by apertures and for particle beams with large spreads in the momentum space. We discuss the applicability of such approach to ion beams produced by high-intensity lasers interacting with critical plasmas, based on the comparison between theoretical findings and measurements.


  • Design and optimization of a laser-PIXE beamline for material science applications

    by A. Morabito, M. Scisciò, S. Veltri, M. Migliorati, P. Antici

    Multi-MeV proton beams can be generated by irradiating thin solid foils with ultra-intense (>1018 W/cm2) short laser pulses. Several of their characteristics, such as high bunch charge and short pulse duration, make them a complementary alternative to conventional radio frequency-based accelerators. A potential material science application is the chemical analysis of cultural heritage (CH) artifacts. The complete chemistry of the bulk material (ceramics, metals) can be retrieved through sophisticated nuclear techniques such as particle-induced X-ray emission (PIXE). Recently, the use of laser-generated proton beams was introduced as diagnostics in material science (laser-PIXE or laser-driven PIXE): Coupling laser-generated proton sources to conventional beam steering devices successfully enhances the capture and transport of the laser-accelerated beam. This leads to a reduction of the high divergence and broad energy spread at the source. The design of our hybrid beamline is composed of an energy selector, followed by permanent quadrupole magnets aiming for better control and manipulation of the final proton beam parameters. This allows tailoring both, mean proton energy and spot sizes, yet keeping the system compact. We performed a theoretical study optimizing a beamline for laser-PIXE applications. Our design enables monochromatizing the beam and shaping its final spot size. We obtain spot sizes ranging between a fraction of mm up to cm scale at a fraction of nC proton charge per shot. These results pave the way for a versatile and tunable laser-PIXE at a multi-Hz repetition rate using modern commercially available laser systems.


  • Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability

    by S. N. Chen, M. Gauthier, M. Bazalova-Carter, S. Bolanos, S. Glenzer, R. Riquier, G. Revet, P. Antici, A. Morabito, A. Propp, et al.

    Radiochromic films (RCF) are commonly used in dosimetry for a wide range of radiation sources (electrons, protons, and photons) for medical, industrial, and scientific applications. They are multi-layered, which includes plastic substrate layers and sensitive layers that incorporate a radiation-sensitive dye. Quantitative dose can be retrieved by digitizing the film, provided that a prior calibration exists. Here, to calibrate the newly developed EBT3 and HDv2 RCFs from Gafchromic™, we used the Stanford Medical LINAC to deposit in the films various doses of 10 MeV photons, and by scanning the films using three independent EPSON Precision 2450 scanners, three independent EPSON V750 scanners, and two independent EPSON 11000XL scanners. The films were scanned in separate RGB channels, as well as in black and white, and film orientation was varied. We found that the green channel of the RGB scan and the grayscale channel are in fact quite consistent over the different models of the scanner, although this comes at the cost of a reduction in sensitivity (by a factor ∼2.5 compared to the red channel). To allow any user to extend the absolute calibration reported here to any other scanner, we furthermore provide a calibration curve of the EPSON 2450 scanner based on absolutely calibrated, commercially available, optical density filters.