Thomas de Lange
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas de Lange has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
- Michael Alexander Riegler
SimulaMet, Oslo, Norway
9 shared publications - Kristin Ranheim Randel
Department of Colorectal Cancer Screening, Cancer Registry of Norway, Norwegian Institute of Public Health
8 shared publications - Anna Lisa Schult
Section for Colorectal Cancer Screening, Cancer Registry of Norway, Oslo, Norway
7 shared publications - Debesh Jha
Northwestern University
7 shared publications - Edoardo Botteri
Cancer Registry of Norway, Oslo, Norway
7 shared publications - Pål Halvorsen
Oslo Metropolitan University, Oslo, Norway
7 shared publications
Latest Publications
- Open Access
- 22 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials
Background and study aims Computer-aided diagnosis (CADx) is intended to improve real-time characterization of colorectal polyps. This study evaluates whether CADx-assisted colonoscopy improves the accuracy of polyp classification compared with conventional colonoscopy (CC). Patients and methods We pooled CADx-relevant data from two randomized trials evaluating CAD EYE and GI Genius. Participants were randomized 1:1 to CADx-assisted colonoscopy or conventional colonoscopy, with no AI active at any stage in the control group. The primary outcome was per-polyp accuracy of the endoscopist’s optical diagnosis against histopathology. Results 684 patients with 1,154 lesion records were included, 795 lesions (451 CADx-assisted, 344 CC) entering the primary analysis. Overall accuracy did not differ between CADx-assisted endoscopy and CC (76.9%, 95% CI 72.8–80.6 vs 79.7%, 75.1–83.6). CC showed higher sensitivity than CADx-assisted endoscopy (88.9%, 84.2–92.3 vs 80.6%, 75.9–84.6; adjusted odds ratio 0.50, 0.28–0.91), with a similar trend for negative predictive value (NPV) (71.7% vs 58.9%). The sensitivity difference was confined to experienced and expert endoscopists (89.4% vs 80.2%) and absent among trainees and newly qualified specialists (p for interaction 0.248). For 0–4 mm polyps, NPV was 71.4% with CC and 54.2% with CADx; for 0–4 mm rectosigmoid lesions, the population to which the guideline threshold applies, it was 92.9% and 66.7%. At least one adenoma was optically classified as non-neoplastic in 25.9% of CADx participants versus 13.0% of CC participants (p=0.003). Conclusions CADx assistance did not improve polyp characterization, and sensitivity for adenomatous lesions was lower when a prediction was displayed. These findings indicate that CADx requires refinement before it can support optical management.
- 22 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Open AccessArtificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials
Background and study aims Computer-aided diagnosis (CADx) is intended to improve real-time characterization of colorectal polyps. This study evaluates whether CADx-assisted colonoscopy improves the accuracy of polyp classification compared with conventional colonoscopy (CC). Patients and methods We pooled CADx-relevant data from two randomized trials evaluating CAD EYE and GI Genius. Participants were randomized 1:1 to CADx-assisted colonoscopy or conventional colonoscopy, with no AI active at any stage in the control group. The primary outcome was per-polyp accuracy of the endoscopist’s optical diagnosis against histopathology. Results 684 patients with 1,154 lesion records were included, 795 lesions (451 CADx-assisted, 344 CC) entering the primary analysis. Overall accuracy did not differ between CADx-assisted endoscopy and CC (76.9%, 95% CI 72.8–80.6 vs 79.7%, 75.1–83.6). CC showed higher sensitivity than CADx-assisted endoscopy (88.9%, 84.2–92.3 vs 80.6%, 75.9–84.6; adjusted odds ratio 0.50, 0.28–0.91), with a similar trend for negative predictive value (NPV) (71.7% vs 58.9%). The sensitivity difference was confined to experienced and expert endoscopists (89.4% vs 80.2%) and absent among trainees and newly qualified specialists (p for interaction 0.248). For 0–4 mm polyps, NPV was 71.4% with CC and 54.2% with CADx; for 0–4 mm rectosigmoid lesions, the population to which the guideline threshold applies, it was 92.9% and 66.7%. At least one adenoma was optically classified as non-neoplastic in 25.9% of CADx participants versus 13.0% of CC participants (p=0.003). Conclusions CADx assistance did not improve polyp characterization, and sensitivity for adenomatous lesions was lower when a prediction was displayed. These findings indicate that CADx requires refinement before it can support optical management.
- 17 June 2026
- Published by Springer Nature in Nature Reviews Gastroenterology & Hepatology
- Vol. 23 (10) , 776-790
Synthetic data generation: challenges and perspectives for gastrointestinal medicine
In the era of artificial intelligence, machines are demonstrating an unprecedented capacity to learn from massive amounts of real-world data to perform human-like cognitive processes, enabling them to recognize environments, objects, and conditions and make critical decisions more accurately than ever. In the medical field, the potential to generate realistic, privacy-preserving, unbiased synthetic data can be the key to unlocking the potential of artificial intelligence in medicine and overcoming the current barriers such as data privacy concerns and high data curation costs. Advanced data-driven solutions could lead towards more robust clinical decision support systems and enhanced clinical training. This Perspective critically examines current and emerging advances in synthetic data generation, and highlights its anticipated transformational effect for early and efficient prevention, diagnosis and treatment of gastrointestinal diseases. Research challenges and directions are identified for leveraging the benefits of synthetic data as well as translating and adopting them in clinical workflows.
- 17 June 2026
- Published by Springer Nature in Nature Reviews Gastroenterology & Hepatology
- Vol. 23 (10) , 776-790
Synthetic data generation: challenges and perspectives for gastrointestinal medicine
In the era of artificial intelligence, machines are demonstrating an unprecedented capacity to learn from massive amounts of real-world data to perform human-like cognitive processes, enabling them to recognize environments, objects, and conditions and make critical decisions more accurately than ever. In the medical field, the potential to generate realistic, privacy-preserving, unbiased synthetic data can be the key to unlocking the potential of artificial intelligence in medicine and overcoming the current barriers such as data privacy concerns and high data curation costs. Advanced data-driven solutions could lead towards more robust clinical decision support systems and enhanced clinical training. This Perspective critically examines current and emerging advances in synthetic data generation, and highlights its anticipated transformational effect for early and efficient prevention, diagnosis and treatment of gastrointestinal diseases. Research challenges and directions are identified for leveraging the benefits of synthetic data as well as translating and adopting them in clinical workflows.
- Open Access
- 3 May 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (8) , 1-8
Colonoscopy in elderly patients: diagnostic yield, pre-referral assessment and quality indicators in two Swedish cohorts
Colorectal cancer (CRC) is among the most common cancers worldwide and the incidence increases with age [1]. In Sweden and other high-income countries, a large proportion of new CRC diagnoses occur...
- 3 May 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (8) , 1-8
Open AccessColonoscopy in elderly patients: diagnostic yield, pre-referral assessment and quality indicators in two Swedish cohorts
Colorectal cancer (CRC) is among the most common cancers worldwide and the incidence increases with age [1]. In Sweden and other high-income countries, a large proportion of new CRC diagnoses occur...
- Open Access
- 14 April 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (6) , 589-597
Endoscopist as a key determinant of patient pain: a sigmoidoscopy screening model for unbiased assessment
Pain perception during lower gastrointestinal endoscopy varies among individuals and may influence participation in colorectal cancer (CRC) screening. Community reputation and word-of-mouth regardi...
- 14 April 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (6) , 589-597
Open AccessEndoscopist as a key determinant of patient pain: a sigmoidoscopy screening model for unbiased assessment
Pain perception during lower gastrointestinal endoscopy varies among individuals and may influence participation in colorectal cancer (CRC) screening. Community reputation and word-of-mouth regardi...
- Open Access
- 22 February 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (5) , 544-554
Adalimumab and infliximab are equally efficient in achieving sustained remission in ulcerative colitis but infliximab is superior in severe disease—a retrospective observational study
Infliximab and adalimumab are first-line biological therapies in ulcerative colitis. Meta-analyses of randomized control trials indicate infliximab being more effective but observational studies indicate similar effect. Our aim was to compare short- and long-term efficacy of infliximab and adalimumab in bio-naive patients with ulcerative colitis in a real-world setting during the modern era of therapeutic drug monitoring and dose optimization. We performed a retrospective multicentre observational cohort study. Patients initiating infliximab or adalimumab at four out-patient IBD-clinics between 2018 and 2022 were included. 105 patients were treated with infliximab and 166 with adalimumab. Steroid-free clinical remission at 12 months was reached in 43% (n = 37) of patients with infliximab and 35% (n = 55) with adalimumab (aOR: 1.41 (0.81-2.45), p = 0.22). Clinical remission at 3 months was more common with infliximab than adalimumab (68 vs. 57%, aOR 1.83 (1.07-3.14), p < 0.05) but no difference was observed regarding clinical response at 3 months, clinical remission at 12 months, and biochemical remission at 3 months and at 12 months. In the subpopulations with mild and moderate disease activity, infliximab and adalimumab were equal regarding clinical remission at 3 months and steroid-free clinical remission at 12 months. In patients with severe disease activity, infliximab had higher remission rates than adalimumab at 3 months; 70% (n = 32) vs. 46% (n = 26) (p < 0.05). Adalimumab and infliximab achieved similar rates of long-term remission in bio-naive patients with ulcerative colitis. However, infliximab was superior in induction of remission and in patients with severe disease.
- 22 February 2026
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 61 (5) , 544-554
Open AccessAdalimumab and infliximab are equally efficient in achieving sustained remission in ulcerative colitis but infliximab is superior in severe disease—a retrospective observational study
Infliximab and adalimumab are first-line biological therapies in ulcerative colitis. Meta-analyses of randomized control trials indicate infliximab being more effective but observational studies indicate similar effect. Our aim was to compare short- and long-term efficacy of infliximab and adalimumab in bio-naive patients with ulcerative colitis in a real-world setting during the modern era of therapeutic drug monitoring and dose optimization. We performed a retrospective multicentre observational cohort study. Patients initiating infliximab or adalimumab at four out-patient IBD-clinics between 2018 and 2022 were included. 105 patients were treated with infliximab and 166 with adalimumab. Steroid-free clinical remission at 12 months was reached in 43% (n = 37) of patients with infliximab and 35% (n = 55) with adalimumab (aOR: 1.41 (0.81-2.45), p = 0.22). Clinical remission at 3 months was more common with infliximab than adalimumab (68 vs. 57%, aOR 1.83 (1.07-3.14), p < 0.05) but no difference was observed regarding clinical response at 3 months, clinical remission at 12 months, and biochemical remission at 3 months and at 12 months. In the subpopulations with mild and moderate disease activity, infliximab and adalimumab were equal regarding clinical remission at 3 months and steroid-free clinical remission at 12 months. In patients with severe disease activity, infliximab had higher remission rates than adalimumab at 3 months; 70% (n = 32) vs. 46% (n = 26) (p < 0.05). Adalimumab and infliximab achieved similar rates of long-term remission in bio-naive patients with ulcerative colitis. However, infliximab was superior in induction of remission and in patients with severe disease.
- Open Access
A comparative study benchmarking colon polyp with computer‐aided detection (CADe) software
Background and aims: Computer‐aided detection software (CADe) has shown promising results in real‐time polyp detection, but a limited head‐to‐head comparison of the available CADe systems has been performed. Moreover, such systems have not been compared to endoscopists using standardized videos. This study aims to compare the performance of three CADe systems in detecting polyps, employing a novel standardized methodology.Methods: Videos from 300 colonoscopies conducted at Oslo University Hospital were analyzed. Short video clips (20–45 s) presenting normal mucosa or polyps were randomly selected. These videos were then streamed through each CADe system from Medtronic, Olympus, and Augere Medical. Each system featured diverse configurations, resulting in a total of six software settings. Sensitivity and false positivity (FP) were assessed by comparing the CADe systems to both the mean of the systems and pairwise between them. Furthermore, the systems’ performance was compared to the performance of five endoscopists.Results: CADe systems’ sensitivity ranged between 84.9% and 98.7%, with statistically significant differences observed between the systems, both in comparison to the mean and to each other. FP rates ranged between 1.2% and 5.6%, also differing statistically significantly between the systems. The CADe systems achieving the highest sensitivity also exhibited the highest FP. Statistically significant differences in the alert delay were observed between different CADe systems and endoscopists.Conclusions: This study highlights significant differences between commercially available CADe software regarding sensitivity and FP, but a superior performance compared to endoscopists. The software with the highest sensitivity also exhibited the highest FP, highlighting the need for further refinement.
Open AccessA comparative study benchmarking colon polyp with computer‐aided detection (CADe) software
Background and aims: Computer‐aided detection software (CADe) has shown promising results in real‐time polyp detection, but a limited head‐to‐head comparison of the available CADe systems has been performed. Moreover, such systems have not been compared to endoscopists using standardized videos. This study aims to compare the performance of three CADe systems in detecting polyps, employing a novel standardized methodology.Methods: Videos from 300 colonoscopies conducted at Oslo University Hospital were analyzed. Short video clips (20–45 s) presenting normal mucosa or polyps were randomly selected. These videos were then streamed through each CADe system from Medtronic, Olympus, and Augere Medical. Each system featured diverse configurations, resulting in a total of six software settings. Sensitivity and false positivity (FP) were assessed by comparing the CADe systems to both the mean of the systems and pairwise between them. Furthermore, the systems’ performance was compared to the performance of five endoscopists.Results: CADe systems’ sensitivity ranged between 84.9% and 98.7%, with statistically significant differences observed between the systems, both in comparison to the mean and to each other. FP rates ranged between 1.2% and 5.6%, also differing statistically significantly between the systems. The CADe systems achieving the highest sensitivity also exhibited the highest FP. Statistically significant differences in the alert delay were observed between different CADe systems and endoscopists.Conclusions: This study highlights significant differences between commercially available CADe software regarding sensitivity and FP, but a superior performance compared to endoscopists. The software with the highest sensitivity also exhibited the highest FP, highlighting the need for further refinement.
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (01) , 1-20
Vision transformer distillation for enhanced gastrointestinal abnormality recognition in wireless capsule endoscopy images
PurposeWireless capsule endoscopy (WCE) is a non-invasive technology used for diagnosing gastrointestinal abnormalities. A single examination generates ∼55,000 images, making manual review both time-consuming and costly for doctors. Therefore, the development of computer vision-assisted systems is highly desirable to aid in the diagnostic process.ApproachWe presents a deep learning approach leveraging knowledge distillation (KD) from a convolutional neural network (CNN) teacher model to a vision transformer (ViT) student model for gastrointestinal abnormality recognition. The CNN teacher model utilizes attention mechanisms and depth-wise separable convolutions to extract features from WCE images, supervising the ViT in learning these representations.ResultsThe proposed method achieves accuracy of 97% and 96% on the Kvasir and KID datasets, respectively, demonstrating its effectiveness in distinguishing normal from abnormal regions and bleeding from non-bleeding cases. The proposed approach offers computational efficiency and generalization to unseen datasets, outperforming several state-of-the-art methods.ConclusionsWe proposed a deep learning approach utilizing CNNs and a ViT with KD to effectively classify gastrointestinal diseases in WCE images. It demonstrates promising performance on public datasets, distinguishing normal from abnormal regions and bleeding from non-bleeding cases while offering optimal computational efficiency compared with existing methods, making it suitable for GI disease applications.
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (01) , 1-20
Vision transformer distillation for enhanced gastrointestinal abnormality recognition in wireless capsule endoscopy images
PurposeWireless capsule endoscopy (WCE) is a non-invasive technology used for diagnosing gastrointestinal abnormalities. A single examination generates ∼55,000 images, making manual review both time-consuming and costly for doctors. Therefore, the development of computer vision-assisted systems is highly desirable to aid in the diagnostic process.ApproachWe presents a deep learning approach leveraging knowledge distillation (KD) from a convolutional neural network (CNN) teacher model to a vision transformer (ViT) student model for gastrointestinal abnormality recognition. The CNN teacher model utilizes attention mechanisms and depth-wise separable convolutions to extract features from WCE images, supervising the ViT in learning these representations.ResultsThe proposed method achieves accuracy of 97% and 96% on the Kvasir and KID datasets, respectively, demonstrating its effectiveness in distinguishing normal from abnormal regions and bleeding from non-bleeding cases. The proposed approach offers computational efficiency and generalization to unseen datasets, outperforming several state-of-the-art methods.ConclusionsWe proposed a deep learning approach utilizing CNNs and a ViT with KD to effectively classify gastrointestinal diseases in WCE images. It demonstrates promising performance on public datasets, distinguishing normal from abnormal regions and bleeding from non-bleeding cases while offering optimal computational efficiency compared with existing methods, making it suitable for GI disease applications.
- Open Access
- 7 October 2024
- Published by Wiley in Alimentary Pharmacology & Therapeutics
- Vol. 61 (1) , 122-131
Performance of Faecal Immunochemical Testing for Colorectal Cancer Screening at Varying Positivity Thresholds
Background: The positivity thresholds of faecal immunochemical testing (FIT) in colorectal cancer (CRC) screening vary between countries.Aims: To explore the trade‐off between colonoscopies performed, adverse events and lesions detected at different FIT thresholds in a Norwegian CRC screening trial.Methods: We included first participation in biennial FIT screening for 47,265 individuals aged 50–74 years. Individuals with FIT > 15 μg Hb/g faeces were referred for colonoscopy. We estimated the number of colonoscopies, adverse events, screen‐detected CRCs, advanced adenomas and serrated lesions expected at FIT thresholds currently or recently used in other European countries ranging between 20 and 150 μg/g.Results: At the 15 μg/g threshold (Norway), 3705 participants underwent colonoscopy, of whom 203 had CRC, 1119 advanced adenomas and 256 advanced serrated lesions. Using a 47 μg/g threshold, 1826 (49.3%) individuals would have undergone colonoscopy, and 154 (75.9%) would have been diagnosed with CRC, 702 (62.7%) with advanced adenoma and 128 (50.0%) with advanced serrated lesion compared to the 15 μg/g threshold. At 150 μg/g, the corresponding figures would have been 838 (22.6%) undergoing colonoscopy, 114 (56.2%) with CRC, 345 (30.8%) advanced adenoma and 54 (21.1%) advanced serrated lesions. The detection rate of stage I CRC was 0.22% at 15 μg/g and 0.11% at 150 μg/g. Post‐colonoscopy bleeding rates were 0.8% and 1.7%, respectively.Conclusions: Increasing the FIT threshold reduces colonoscopy demand, but substantially decreases lesion detection and unfavourably changes CRC stage distribution. The risk of adverse events at colonoscopy increased with FIT threshold, requiring country‐specific information on adverse events.Trial Registration: Clinicaltrials.gov identifier: NCT01538550
- 7 October 2024
- Published by Wiley in Alimentary Pharmacology & Therapeutics
- Vol. 61 (1) , 122-131
Open AccessPerformance of Faecal Immunochemical Testing for Colorectal Cancer Screening at Varying Positivity Thresholds
Background: The positivity thresholds of faecal immunochemical testing (FIT) in colorectal cancer (CRC) screening vary between countries.Aims: To explore the trade‐off between colonoscopies performed, adverse events and lesions detected at different FIT thresholds in a Norwegian CRC screening trial.Methods: We included first participation in biennial FIT screening for 47,265 individuals aged 50–74 years. Individuals with FIT > 15 μg Hb/g faeces were referred for colonoscopy. We estimated the number of colonoscopies, adverse events, screen‐detected CRCs, advanced adenomas and serrated lesions expected at FIT thresholds currently or recently used in other European countries ranging between 20 and 150 μg/g.Results: At the 15 μg/g threshold (Norway), 3705 participants underwent colonoscopy, of whom 203 had CRC, 1119 advanced adenomas and 256 advanced serrated lesions. Using a 47 μg/g threshold, 1826 (49.3%) individuals would have undergone colonoscopy, and 154 (75.9%) would have been diagnosed with CRC, 702 (62.7%) with advanced adenoma and 128 (50.0%) with advanced serrated lesion compared to the 15 μg/g threshold. At 150 μg/g, the corresponding figures would have been 838 (22.6%) undergoing colonoscopy, 114 (56.2%) with CRC, 345 (30.8%) advanced adenoma and 54 (21.1%) advanced serrated lesions. The detection rate of stage I CRC was 0.22% at 15 μg/g and 0.11% at 150 μg/g. Post‐colonoscopy bleeding rates were 0.8% and 1.7%, respectively.Conclusions: Increasing the FIT threshold reduces colonoscopy demand, but substantially decreases lesion detection and unfavourably changes CRC stage distribution. The risk of adverse events at colonoscopy increased with FIT threshold, requiring country‐specific information on adverse events.Trial Registration: Clinicaltrials.gov identifier: NCT01538550
- Open Access
- 16 September 2024
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 42 (1)
Key Control Characteristics of Carbon Black Materials for Fuel Cells and Batteries for a Standardized Characterization of Surface Properties
Carbon Blacks (CBs) are primarily used in electrocatalysis as support materials for nanoparticulate electrocatalysts. In fuel cells, CBs, catalysts, and proton conductive polymers (ionomers) undergo a dispersion/homogenization process for electrode coating. The interactions between components in dispersion and the surface of CB particles are complex. The surface characteristics of CB particles impact slurry formulation, electrode coating, and the resulting electrode layer, affecting fuel cell and battery performance and durability. This study investigates commercially available CBs such as Vulcan XC72R, Ketjen Black EC‐300J, Ketjen Black EC‐600JD, and Super C65, focusing on application‐relevant key control characteristics (KCCs). The KCCs include physicochemical features like electrical conductivity (electron transport through the catalyst layer, CL), oxygen‐containing surface groups (hydrophilicity/phobicity of the CL, catalyst functionalization), surface basicity/acidity, ionomer adsorption, and particle dispersibility (catalyst ink stability). KCCs are determined by particle bulk electrical conductivity, Boehm titration (BT), isoelectric point (IEP), and Hansen solubility parameters (HSP). HSP, understood as similarity parameters for particles, indicate how nanoparticle surfaces interact with liquids during dispersion. The proposed KCCs serve as a starting point for characterizing CBs and guiding product design to obtain meaningful structure‐property relationships, essential for a successful energy transition.
- 16 September 2024
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 42 (1)
Open AccessKey Control Characteristics of Carbon Black Materials for Fuel Cells and Batteries for a Standardized Characterization of Surface Properties
Carbon Blacks (CBs) are primarily used in electrocatalysis as support materials for nanoparticulate electrocatalysts. In fuel cells, CBs, catalysts, and proton conductive polymers (ionomers) undergo a dispersion/homogenization process for electrode coating. The interactions between components in dispersion and the surface of CB particles are complex. The surface characteristics of CB particles impact slurry formulation, electrode coating, and the resulting electrode layer, affecting fuel cell and battery performance and durability. This study investigates commercially available CBs such as Vulcan XC72R, Ketjen Black EC‐300J, Ketjen Black EC‐600JD, and Super C65, focusing on application‐relevant key control characteristics (KCCs). The KCCs include physicochemical features like electrical conductivity (electron transport through the catalyst layer, CL), oxygen‐containing surface groups (hydrophilicity/phobicity of the CL, catalyst functionalization), surface basicity/acidity, ionomer adsorption, and particle dispersibility (catalyst ink stability). KCCs are determined by particle bulk electrical conductivity, Boehm titration (BT), isoelectric point (IEP), and Hansen solubility parameters (HSP). HSP, understood as similarity parameters for particles, indicate how nanoparticle surfaces interact with liquids during dispersion. The proposed KCCs serve as a starting point for characterizing CBs and guiding product design to obtain meaningful structure‐property relationships, essential for a successful energy transition.
- Open Access
- 8 June 2024
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 59 (8) , 1002-1009
Impact of inadequate bowel cleansing in sigmoidoscopy screening
Colorectal cancer (CRC) is a major health burden with more than 1.9 million annual new cases in 2020 worldwide [1]. The most effective and efficient approach for CRC screening is still unknown and ...
- 8 June 2024
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 59 (8) , 1002-1009
Open AccessImpact of inadequate bowel cleansing in sigmoidoscopy screening
Colorectal cancer (CRC) is a major health burden with more than 1.9 million annual new cases in 2020 worldwide [1]. The most effective and efficient approach for CRC screening is still unknown and ...