Kevin Kubachka
Research Subjects
Kevin Kubachka has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Aline Fernandes de Oliveira
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00 Brno, Czech Republic
2 shared publications - John T. Creed
USEPA, CESER, 26 W. Martin Luther King Drive, Cincinnati, OH 45268, USA
2 shared publications - Madhavi Mantha
U.S. Food and Drug Administration, Forensic Chemistry Center, Office of Regulatory Science, Office of Regulatory Affairs , 6751 Steger Dr , Cincinnati, OH 45237, USA
2 shared publications Nicole Hanks
Student Service Contractor, USEPA, CESER, Cincinnati, OH 45268, USA
2 shared publicationsRobert A. Wilson
U.S. Food and Drug Administration, Forensic Chemistry Center, Cincinnati, OH 45237, USA
2 shared publicationsTravis Falconer
Office of Regulatory Affairs, Office of Regulatory Science, Forensic Chemistry Center, U.S. Food and Drug Administration, Cincinnati, USA
2 shared publications
Latest Publications
- Open Access
- 13 March 2026
- Published by SAGE Publications in Applied Spectroscopy Practica
- Vol. 4 (1)
Detection of Lead (II) Chromate in Cinnamon
As part of the public health investigation into elevated lead (Pb) levels in an apple cinnamon fruit puree, cinnamon was identified as the source of contamination. Cinnamon samples were tested by inductively coupled plasma mass spectrometry (ICP-MS) at the U.S. Food and Drug Administration's (FDA) Kansas City Human and Animal Food Laboratory and determined to contain elevated levels of Pb (>2000–5000 µg/g) and chromium (Cr) (>500–1200 µg/g). Total Pb and Cr concentrations alone could not determine the source of the contamination. To aid in the investigation of potential sources of the Pb and Cr contamination, e.g., particles from grinding equipment or addition of lead (II) chromate (PbCrO 4 ), further information was needed. The FDA's National Forensic Chemistry Center conducted additional analyses in which suspected lead (II) chromate particles were physically isolated and preconcentrated, then analyzed by Raman microspectroscopy. Once Raman spectra of the preconcentrated particles were obtained, the same particles were removed from the microscope slide and digested with nitric acid for ICP-MS analysis. The combination of the Raman spectral comparison to a lead (II) chromate reference standard and confirmation of Pb and Cr in the particles with 1:1 stoichiometry using ICP-MS identified lead (II) chromate as the contamination source. This confirmed that lead (II) chromate had been added to the cinnamon, suggesting intentional adulteration. Previous reports indicate that lead (II) chromate can be added to spices to enhance the color and/or increase the mass of the product. This paper demonstrates how combining two complimentary instrumental techniques was used to identify and quantify an inorganic compound in a possible case of economically motivated adulteration.
- 13 March 2026
- Published by SAGE Publications in Applied Spectroscopy Practica
- Vol. 4 (1)
Open AccessDetection of Lead (II) Chromate in Cinnamon
As part of the public health investigation into elevated lead (Pb) levels in an apple cinnamon fruit puree, cinnamon was identified as the source of contamination. Cinnamon samples were tested by inductively coupled plasma mass spectrometry (ICP-MS) at the U.S. Food and Drug Administration's (FDA) Kansas City Human and Animal Food Laboratory and determined to contain elevated levels of Pb (>2000–5000 µg/g) and chromium (Cr) (>500–1200 µg/g). Total Pb and Cr concentrations alone could not determine the source of the contamination. To aid in the investigation of potential sources of the Pb and Cr contamination, e.g., particles from grinding equipment or addition of lead (II) chromate (PbCrO 4 ), further information was needed. The FDA's National Forensic Chemistry Center conducted additional analyses in which suspected lead (II) chromate particles were physically isolated and preconcentrated, then analyzed by Raman microspectroscopy. Once Raman spectra of the preconcentrated particles were obtained, the same particles were removed from the microscope slide and digested with nitric acid for ICP-MS analysis. The combination of the Raman spectral comparison to a lead (II) chromate reference standard and confirmation of Pb and Cr in the particles with 1:1 stoichiometry using ICP-MS identified lead (II) chromate as the contamination source. This confirmed that lead (II) chromate had been added to the cinnamon, suggesting intentional adulteration. Previous reports indicate that lead (II) chromate can be added to spices to enhance the color and/or increase the mass of the product. This paper demonstrates how combining two complimentary instrumental techniques was used to identify and quantify an inorganic compound in a possible case of economically motivated adulteration.
- 3 October 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 69-76
Using Liquid Chromatography—Isotope Ratio Mass Spectrometry for Detection of Economically Motivated Adulteration of Maple Syrup
Background: Maple syrup is a sought-after commodity, and used as a condiment and a sweetener. Also, it is an active target of economically motivated adulteration (EMA), similar to other foods such as lemon juice and honey. Objective: This study is aimed to detect low cost sugar adulteration in maple syrup via an internal standard method using malic acid through solid-phase extraction (SPE) and LC with isotope ratio mass spectrometric detection (LC–IRMS). Methods: In this work, an optimized SPE sample preparation procedure was used for the isolation of organic acids from maple syrup. Using LC–IRMS, malic acid was separated from other organic acids and the δ13C value of malic acid was determined. Eleven maple syrup samples, domestic or imported from Canada, were evaluated for 13C/12C ratios (δ13C values) using combustion module—cavity ring down spectrometry (CM-CRDS) and compared to the δ13C values obtained from well-established elemental analyzer–isotope ratio mass spectrometry (EA–IRMS) methods. The δ13C values of isolated malic acid analyzed by SPE–LC–IRMS were used as internal standards and compared to the δ13C values of bulk maple syrup; difference (δ13Csugars − δ13Cmalic acid) values greater than 3.6‰ are indicative of low-cost sugar adulteration. Results: Overall, the results obtained from SPE–LC–IRMS provided a faster, novel analysis approach for determining low-cost sugar adulteration in maple syrup for regulatory purposes. This method also provided lower detectable limits of adulteration versus current literature reports using bulk analysis and comparable detection limits to Tremblay and co-workers who utilized an internal standard method. Conclusion: SPE–LC–IRMS is a robust method that can be used for detecting adulteration in maple syrup samples for regulatory purposes. Highlights: SPE-LC-IRMS is a faster, novel analysis approach for determining C4 adulteration in maple syrup with lower detection limits.
- 3 October 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 69-76
Using Liquid Chromatography—Isotope Ratio Mass Spectrometry for Detection of Economically Motivated Adulteration of Maple Syrup
Background: Maple syrup is a sought-after commodity, and used as a condiment and a sweetener. Also, it is an active target of economically motivated adulteration (EMA), similar to other foods such as lemon juice and honey. Objective: This study is aimed to detect low cost sugar adulteration in maple syrup via an internal standard method using malic acid through solid-phase extraction (SPE) and LC with isotope ratio mass spectrometric detection (LC–IRMS). Methods: In this work, an optimized SPE sample preparation procedure was used for the isolation of organic acids from maple syrup. Using LC–IRMS, malic acid was separated from other organic acids and the δ13C value of malic acid was determined. Eleven maple syrup samples, domestic or imported from Canada, were evaluated for 13C/12C ratios (δ13C values) using combustion module—cavity ring down spectrometry (CM-CRDS) and compared to the δ13C values obtained from well-established elemental analyzer–isotope ratio mass spectrometry (EA–IRMS) methods. The δ13C values of isolated malic acid analyzed by SPE–LC–IRMS were used as internal standards and compared to the δ13C values of bulk maple syrup; difference (δ13Csugars − δ13Cmalic acid) values greater than 3.6‰ are indicative of low-cost sugar adulteration. Results: Overall, the results obtained from SPE–LC–IRMS provided a faster, novel analysis approach for determining low-cost sugar adulteration in maple syrup for regulatory purposes. This method also provided lower detectable limits of adulteration versus current literature reports using bulk analysis and comparable detection limits to Tremblay and co-workers who utilized an internal standard method. Conclusion: SPE–LC–IRMS is a robust method that can be used for detecting adulteration in maple syrup samples for regulatory purposes. Highlights: SPE-LC-IRMS is a faster, novel analysis approach for determining C4 adulteration in maple syrup with lower detection limits.
- Open Access
- 6 January 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (1) , 5-6
Solution to arsenic speciation challenge
- 6 January 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (1) , 5-6
Open AccessSolution to arsenic speciation challenge
- 8 June 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (16) , 4535-4536
Arsenic speciation challenge
- 8 June 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (16) , 4535-4536
Arsenic speciation challenge
- 18 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (4) , 898-909
An evaluation of M2+ interference correction approaches associated with As and Se in ICP-MS using a multi-day dataset along with ICP-MS/MS/HR-ICP-MS based analysis and hierarchical modeling as a means of assessing bias in fortified drinking waters and single component matrices
M2+ internal standard ions mimic the drift of other M2+ ions better than M1+. ICP-MS/MS and HR-ICP-MS are used to assess the bias of various M2+ corrections while a Bayesian hierarchical model is used to estimate day to day impacts on the correction.
- 18 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (4) , 898-909
An evaluation of M2+ interference correction approaches associated with As and Se in ICP-MS using a multi-day dataset along with ICP-MS/MS/HR-ICP-MS based analysis and hierarchical modeling as a means of assessing bias in fortified drinking waters and single component matrices
M2+ internal standard ions mimic the drift of other M2+ ions better than M1+. ICP-MS/MS and HR-ICP-MS are used to assess the bias of various M2+ corrections while a Bayesian hierarchical model is used to estimate day to day impacts on the correction.
- Open Access
- 16 November 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (47) , 32090-32100
Elemental Analysis of Tetrahydrocannabinol and Nicotine E-Liquids Related to EVALI
- 16 November 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (47) , 32090-32100
Open AccessElemental Analysis of Tetrahydrocannabinol and Nicotine E-Liquids Related to EVALI
- 1 October 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (10) , 2094-2104
Analytical considerations associated with implementing M2+ correction factors to address false positives on As and Se within U.S. EPA method 200.8
Rare earth elements (REE) can produce M2+ ions in ICP-MS and 150Nd2+, 150Sm2+, and 156Gd2+ can produce false positives on 75As and 78Se.
- 1 October 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (10) , 2094-2104
Analytical considerations associated with implementing M2+ correction factors to address false positives on As and Se within U.S. EPA method 200.8
Rare earth elements (REE) can produce M2+ ions in ICP-MS and 150Nd2+, 150Sm2+, and 156Gd2+ can produce false positives on 75As and 78Se.
- Open Access
- 10 September 2019
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (12) , 2845-2856
Quantitative Determination of Arsenic Species from Fruit Juices Using Acidic Extraction with HPLC-ICPMS
Throughout the US Food and Drug Administration’s routine monitoring of various juice samples for elemental contaminants, a limited number of samples exhibited unexpected behavior related to the arsenic content. Juice samples were subjected to total arsenic determination and those containing arsenic > 10 μg kg−1 were subjected to arsenic speciation analysis using FDA Elemental Analysis Manual (EAM) 4.10 method (AOAC First Action Method 2016.04) to determine the concentration of iAs and other common organic arsenicals. For a subset of samples, the sum of the arsenic species was significantly less than the total arsenic value (i.e., mass balance < 65%), which is uncommon for a liquid-based matrix. Juice types that have exhibited this behavior include pomegranate, prune, and cherry juices. Causes for this issue were explored which ultimately led to an alternate sample preparation technique, extraction with 0.28 M HNO3 along with heat, which resulted in drastically improved mass balances approaching 100%. The method proved robust, with both accurate and precise measurements for multiple juice samples analyzed by a total of four laboratories. Two laboratories performed a level 3 multilaboratory validation. This work discusses various issues that were encountered, attempts to determine the source of the problem, the eventual solution in the form of a modified extraction procedure, and the multilaboratory validation results.
- 10 September 2019
- Published by Springer Nature in Food Analytical Methods
- Vol. 12 (12) , 2845-2856
Open AccessQuantitative Determination of Arsenic Species from Fruit Juices Using Acidic Extraction with HPLC-ICPMS
Throughout the US Food and Drug Administration’s routine monitoring of various juice samples for elemental contaminants, a limited number of samples exhibited unexpected behavior related to the arsenic content. Juice samples were subjected to total arsenic determination and those containing arsenic > 10 μg kg−1 were subjected to arsenic speciation analysis using FDA Elemental Analysis Manual (EAM) 4.10 method (AOAC First Action Method 2016.04) to determine the concentration of iAs and other common organic arsenicals. For a subset of samples, the sum of the arsenic species was significantly less than the total arsenic value (i.e., mass balance < 65%), which is uncommon for a liquid-based matrix. Juice types that have exhibited this behavior include pomegranate, prune, and cherry juices. Causes for this issue were explored which ultimately led to an alternate sample preparation technique, extraction with 0.28 M HNO3 along with heat, which resulted in drastically improved mass balances approaching 100%. The method proved robust, with both accurate and precise measurements for multiple juice samples analyzed by a total of four laboratories. Two laboratories performed a level 3 multilaboratory validation. This work discusses various issues that were encountered, attempts to determine the source of the problem, the eventual solution in the form of a modified extraction procedure, and the multilaboratory validation results.
- 5 May 2017
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 100 (4) , 1077-1085
Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography–Inductively Coupled Plasma–Mass Spectrometry
Before being designated AOAC First Action Official Method SM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography–Inductively Coupled Plasma–Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96–98% of certified values for total arsenic.
- 5 May 2017
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 100 (4) , 1077-1085
Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography–Inductively Coupled Plasma–Mass Spectrometry
Before being designated AOAC First Action Official Method SM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography–Inductively Coupled Plasma–Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96–98% of certified values for total arsenic.