Toshiaki Sasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Toshiaki Sasaki has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
Kazunori Terasaki
6 shared publicationsHisashi Yonezawa
Division of Neurology and Gerontology, Department of Internal Medicine, School of Medicine, Iwate Medical University
3 shared publicationsKuniaki Ogasawara
3 shared publicationsMakoto Sasaki
3 shared publications- Takaaki Beppu
Department of Neurosurgery, Iwate Medical University, Uchimaru 19-1, Morioka, 020-8505, Japan,
3 shared publications Akihiro Takaki
Fujifilm RI Pharma Co.,Ltd., Kyobashi 14-1 2-chome, Chuo-ku, Tokyo 104-0031, Japan
2 shared publications
Latest Publications
- Open Access
- 22 April 2022
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 47 (7) , 569-574
PET With 11C-Methyl-l-Methionine as a Predictor of Consequential Outcomes at the Time of Discontinuing Temozolomide-Adjuvant Chemotherapy in Patients With Residual IDH-Mutant Lower-Grade Glioma
Purpose: The aim of this study was to clarify whether PET with 11C-methyl-l-methionine (11C-met PET) can predict consequential outcomes at the time of discontinuing temozolomide (TMZ)-adjuvant chemotherapy in patients with residual isocitrate dehydrogenase gene (IDH)–mutant lower-grade glioma. Patients and Methods: Among 30 patients showing residual lesions of IDH-mutant lower-grade glioma, we compared the tumor-to-normal brain tissue ratio of standardized uptake values (SUVT/N) from 11C-met PET at the time of discontinuing TMZ-adjuvant chemotherapy with putative predictive factors including age, Karnofsky Performance Scale, number of courses of adjuvant therapy, residual tumor size, and promotor methylation status of O6-methylguanine-DNA methyl-transferase gene (MGMT). For each factor, progression-free survival (PFS) was compared between groups divided by cutoff values, determined to predict tumor relapse using receiver operating characteristic curves for each factor. Univariate and multivariate analyses were conducted using log-rank testing and Cox regression analysis, respectively. In addition, PFS was compared between patients grouped by combined findings from multiple predictors identified from univariate and multivariate analyses. Results: Univariate and multivariate analyses identified SUVT/N from 11C-met PET and MGMT methylation status as independent predictors of outcomes after TMZ discontinuation. When comparing 3 groups assigned by the combination of MGMT and SUVT/N findings, PFS differed significantly among groups. Conclusions: The present study suggested that 11C-met PET at the time of discontinuing TMZ-adjuvant chemotherapy allows prediction of outcomes at least comparable to MGMT methylation status in patients with residual IDH-mutant lower-grade glioma. Further, 11C-met PET allows more precise prediction of outcomes by assessment in combination with MGMT findings.
- 22 April 2022
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 47 (7) , 569-574
Open AccessPET With 11C-Methyl-l-Methionine as a Predictor of Consequential Outcomes at the Time of Discontinuing Temozolomide-Adjuvant Chemotherapy in Patients With Residual IDH-Mutant Lower-Grade Glioma
Purpose: The aim of this study was to clarify whether PET with 11C-methyl-l-methionine (11C-met PET) can predict consequential outcomes at the time of discontinuing temozolomide (TMZ)-adjuvant chemotherapy in patients with residual isocitrate dehydrogenase gene (IDH)–mutant lower-grade glioma. Patients and Methods: Among 30 patients showing residual lesions of IDH-mutant lower-grade glioma, we compared the tumor-to-normal brain tissue ratio of standardized uptake values (SUVT/N) from 11C-met PET at the time of discontinuing TMZ-adjuvant chemotherapy with putative predictive factors including age, Karnofsky Performance Scale, number of courses of adjuvant therapy, residual tumor size, and promotor methylation status of O6-methylguanine-DNA methyl-transferase gene (MGMT). For each factor, progression-free survival (PFS) was compared between groups divided by cutoff values, determined to predict tumor relapse using receiver operating characteristic curves for each factor. Univariate and multivariate analyses were conducted using log-rank testing and Cox regression analysis, respectively. In addition, PFS was compared between patients grouped by combined findings from multiple predictors identified from univariate and multivariate analyses. Results: Univariate and multivariate analyses identified SUVT/N from 11C-met PET and MGMT methylation status as independent predictors of outcomes after TMZ discontinuation. When comparing 3 groups assigned by the combination of MGMT and SUVT/N findings, PFS differed significantly among groups. Conclusions: The present study suggested that 11C-met PET at the time of discontinuing TMZ-adjuvant chemotherapy allows prediction of outcomes at least comparable to MGMT methylation status in patients with residual IDH-mutant lower-grade glioma. Further, 11C-met PET allows more precise prediction of outcomes by assessment in combination with MGMT findings.
- 1 November 2016
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 41 (11) , 852-857
MRI and 11C-methyl-L-methionine PET Differentiate Bevacizumab True Responders After Initiating Therapy for Recurrent Glioblastoma
Normalization of tumor vasculature after administering bevacizumab (BEV) makes assessment of therapeutic response using MRI difficult. The aim of this study was to clarify whether PET with 11C-methyl-L-methionine (MET-PET) would supplement MRI assessing of response after initiating BEV in glioblastoma. Twenty patients with recurrent glioblastoma were treated with biweekly BEV plus temozolomide. Both MRI and MET-PET were performed before treatment (baseline) and at 4 and 8 weeks after starting treatment. Results on MRI (response or nonresponse) were compared with those on MET-PET, with response defined as a tumor-to-normal brain ratio of SUV (SUVT/N) of less than 1.6. Progression-free survival (PFS) was compared between responders and nonresponders on MRI alone and MET-PET alone. Progression-free survival was also compared between patients showing response on both MRI and MET-PET and patients showing response on MRI but nonresponse on MET-PET at each time point. PFS was significantly longer in responders than nonresponders on both MRI at 4 and 8 weeks and MET-PET at 8 weeks, whereas MET-PET at 4 weeks provided no information regarding outcomes. Combined assessment with MRI and MET-PET at 4 weeks was not provide predictive of PFS, whereas patients showing response on both modalities (true responders) at 8 weeks exhibited significantly longer PFS than did patients showing response on MRI but nonresponse on MET-PET (pseudoresponders). Combined assessment with MRI and MET-PET at 8 weeks can differentiate true responders who are predicted to show more favorable prognosis from pseudoresponders.
- 1 November 2016
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 41 (11) , 852-857
MRI and 11C-methyl-L-methionine PET Differentiate Bevacizumab True Responders After Initiating Therapy for Recurrent Glioblastoma
Normalization of tumor vasculature after administering bevacizumab (BEV) makes assessment of therapeutic response using MRI difficult. The aim of this study was to clarify whether PET with 11C-methyl-L-methionine (MET-PET) would supplement MRI assessing of response after initiating BEV in glioblastoma. Twenty patients with recurrent glioblastoma were treated with biweekly BEV plus temozolomide. Both MRI and MET-PET were performed before treatment (baseline) and at 4 and 8 weeks after starting treatment. Results on MRI (response or nonresponse) were compared with those on MET-PET, with response defined as a tumor-to-normal brain ratio of SUV (SUVT/N) of less than 1.6. Progression-free survival (PFS) was compared between responders and nonresponders on MRI alone and MET-PET alone. Progression-free survival was also compared between patients showing response on both MRI and MET-PET and patients showing response on MRI but nonresponse on MET-PET at each time point. PFS was significantly longer in responders than nonresponders on both MRI at 4 and 8 weeks and MET-PET at 8 weeks, whereas MET-PET at 4 weeks provided no information regarding outcomes. Combined assessment with MRI and MET-PET at 4 weeks was not provide predictive of PFS, whereas patients showing response on both modalities (true responders) at 8 weeks exhibited significantly longer PFS than did patients showing response on MRI but nonresponse on MET-PET (pseudoresponders). Combined assessment with MRI and MET-PET at 8 weeks can differentiate true responders who are predicted to show more favorable prognosis from pseudoresponders.
- Open Access
- 25 January 2015
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (4) , 336-341
High-uptake areas on positron emission tomography with the hypoxic radiotracer 18F-FRP170 in glioblastomas include regions retaining proliferative activity under hypoxia
Objective: The aim was to evaluate the proliferative activity of high-uptake areas on positron emission tomography (PET) with the hypoxic cell radiotracer, 1-(2-[18F]fluoro-1-[hydroxymethyl]ethoxy)methyl-2-nitroimidazole (FRP170).Methods: Thirteen patients with glioblastoma underwent FRP170 PET before tumor resection. During surgery, tumor specimens were stereotaxically obtained from regions corresponding to high (high-uptake areas, HUAs) and relatively low (low-uptake areas, LUAs) accumulation of FRP170. We compared immunohistochemical staining for Ki-67 and hypoxia-inducible factor (HIF)-1α between HUA and LUA.Results: HIF-1α index was significantly higher in HUAs than in LUAs. In contrast, mean Ki-67 indices did not differ significantly between HUAs and LUAs.Conclusions: Findings for HIF-1α index clearly indicated that HUAs on FRP170 PET represented hypoxic regions in glioblastoma. However, findings of Ki-67 index suggest that HUAs on FRP170 PET include regions retaining proliferative activity regardless of tissue hypoxia.
- 25 January 2015
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (4) , 336-341
Open AccessHigh-uptake areas on positron emission tomography with the hypoxic radiotracer 18F-FRP170 in glioblastomas include regions retaining proliferative activity under hypoxia
Objective: The aim was to evaluate the proliferative activity of high-uptake areas on positron emission tomography (PET) with the hypoxic cell radiotracer, 1-(2-[18F]fluoro-1-[hydroxymethyl]ethoxy)methyl-2-nitroimidazole (FRP170).Methods: Thirteen patients with glioblastoma underwent FRP170 PET before tumor resection. During surgery, tumor specimens were stereotaxically obtained from regions corresponding to high (high-uptake areas, HUAs) and relatively low (low-uptake areas, LUAs) accumulation of FRP170. We compared immunohistochemical staining for Ki-67 and hypoxia-inducible factor (HIF)-1α between HUA and LUA.Results: HIF-1α index was significantly higher in HUAs than in LUAs. In contrast, mean Ki-67 indices did not differ significantly between HUAs and LUAs.Conclusions: Findings for HIF-1α index clearly indicated that HUAs on FRP170 PET represented hypoxic regions in glioblastoma. However, findings of Ki-67 index suggest that HUAs on FRP170 PET include regions retaining proliferative activity regardless of tissue hypoxia.
- 3 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (4) , 513-520
Development of an automatic ROI setting program for input function determination in 99mTc-ECD non-invasive cerebral blood flow quantification
- 3 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (4) , 513-520
Development of an automatic ROI setting program for input function determination in 99mTc-ECD non-invasive cerebral blood flow quantification
- 5 February 2013
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 27 (4) , 346-354
Validation of novel calibration scheme with traceable point-like 22Na sources on six types of PET scanners
- 5 February 2013
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 27 (4) , 346-354
Validation of novel calibration scheme with traceable point-like 22Na sources on six types of PET scanners
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2873-2875
Application of novel calibration scheme based on traceable point-like 22Na sources to various types of PET scanners
Purpose: We have been developing a practical and reliable calibration scheme based on the use of traceable pointlike sources. In using 22 Na sources, special care should be taken to avoid the effects of 1.275-MeV γ rays accompanying β + decays. The purpose of this study is to validate this calibration method with traceable point-like 22 Na sources on various types of PET scanners. Method: The traceable point-like 22 Na sources with a spherical absorber design used in this study were of the same type as those used in a previous study. The tested PET scanners included one clinical whole-body PET scanner, four types of clinical PET/CT scanners from different manufacturers, and one small-animal PET scanner. The ROI (region of interest) diameter dependence of ROI values were represented with a fitting function, which was assumed to consist of a recovery part due to spatial resolution and a quadratic background part originating from the scattered γ rays. Results: The calibration factors determined using the point-like source were consistent with those by the standard cross-calibration method within ±4%, which was comparable to the uncertainty of the standard cross-calibration method. Conclusion: The novel calibration scheme based on the use of traceable 22 Na point-like sources was validated for six types of commercial PET scanners.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2873-2875
Application of novel calibration scheme based on traceable point-like 22Na sources to various types of PET scanners
Purpose: We have been developing a practical and reliable calibration scheme based on the use of traceable pointlike sources. In using 22 Na sources, special care should be taken to avoid the effects of 1.275-MeV γ rays accompanying β + decays. The purpose of this study is to validate this calibration method with traceable point-like 22 Na sources on various types of PET scanners. Method: The traceable point-like 22 Na sources with a spherical absorber design used in this study were of the same type as those used in a previous study. The tested PET scanners included one clinical whole-body PET scanner, four types of clinical PET/CT scanners from different manufacturers, and one small-animal PET scanner. The ROI (region of interest) diameter dependence of ROI values were represented with a fitting function, which was assumed to consist of a recovery part due to spatial resolution and a quadratic background part originating from the scattered γ rays. Results: The calibration factors determined using the point-like source were consistent with those by the standard cross-calibration method within ±4%, which was comparable to the uncertainty of the standard cross-calibration method. Conclusion: The novel calibration scheme based on the use of traceable 22 Na point-like sources was validated for six types of commercial PET scanners.
- 18 February 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (4) , 351-358
Improvement of the 99mTc-ECD brain uptake ratio (BUR) method for measurement of cerebral blood flow
The brain uptake ratio (BUR) method for the 99mTc-ECD SPECT, a non-invasive measurement method of rCBF, has been used in clinical practice in Japan, because it is simple to use. However, the accuracy of this method is limited, as it has problems in the determination of input function and the regression equation. The purpose of this study is to improve the BUR method by reconstructing the determination process of the input function and regression equation based on measurement of the rCBF by H 2 15 O PET. The input function was obtained by setting the region of interest on the ascending aorta instead of the aortic arch. The 3DSRT algorithm was used to obtain the anatomically standardized rCBF, and developed a semi-automatic analyzing software using C++ in order to stabilize the repeatability of the improved BUR (IBUR) method. The regression equation for the IBUR method was obtained by the H 2 15 O PET rCBFs in 15 patients with the arterial blood sampling method. All the measurements in this study were performed with the patient in the resting state. A good correlation was observed between the rCBF values measured by H 2 15 O PET and the regional BURs measured by the IBUR method (r = 0.86, p < 0.0001). The rCBF values were calculated for only 5 min using a semi-automatic analyzing software. The BUR method was improved by changing the location of the input function from the aortic arch to the ascending aorta based on arterial blood flow dynamics, and reconstructing regression equation based on the rCBF values obtained using H 2 15 O PET. This finding indicates the potential clinical usefulness of this method.
- 18 February 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (4) , 351-358
Improvement of the 99mTc-ECD brain uptake ratio (BUR) method for measurement of cerebral blood flow
The brain uptake ratio (BUR) method for the 99mTc-ECD SPECT, a non-invasive measurement method of rCBF, has been used in clinical practice in Japan, because it is simple to use. However, the accuracy of this method is limited, as it has problems in the determination of input function and the regression equation. The purpose of this study is to improve the BUR method by reconstructing the determination process of the input function and regression equation based on measurement of the rCBF by H 2 15 O PET. The input function was obtained by setting the region of interest on the ascending aorta instead of the aortic arch. The 3DSRT algorithm was used to obtain the anatomically standardized rCBF, and developed a semi-automatic analyzing software using C++ in order to stabilize the repeatability of the improved BUR (IBUR) method. The regression equation for the IBUR method was obtained by the H 2 15 O PET rCBFs in 15 patients with the arterial blood sampling method. All the measurements in this study were performed with the patient in the resting state. A good correlation was observed between the rCBF values measured by H 2 15 O PET and the regional BURs measured by the IBUR method (r = 0.86, p < 0.0001). The rCBF values were calculated for only 5 min using a semi-automatic analyzing software. The BUR method was improved by changing the location of the input function from the aortic arch to the ascending aorta based on arterial blood flow dynamics, and reconstructing regression equation based on the rCBF values obtained using H 2 15 O PET. This finding indicates the potential clinical usefulness of this method.