Serkan Inceoglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Serkan Inceoglu has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Robert F. McLain
8 shared publications- Atilla Akbay
Hacettepe University
4 shared publications Lisa Ferrara
4 shared publicationsEdward C. Benzel
Neurological Institute, Cleveland Clinic, Cleveland, Ohio
3 shared publicationsRyan Milks
3 shared publicationsWayne K. Cheng
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Loma Linda University, Loma Linda, CA
3 shared publications
Latest Publications
- 1 December 2018
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 43 (12) , 1081-1084
K-wire Pull-Out Force After Multiple Redirection Attempts
- 1 December 2018
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 43 (12) , 1081-1084
K-wire Pull-Out Force After Multiple Redirection Attempts
- 1 September 2016
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 31, 219-223
A comparison of Staphylococcus aureus biofilm formation on cobalt-chrome and titanium-alloy spinal implants
- 1 September 2016
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 31, 219-223
A comparison of Staphylococcus aureus biofilm formation on cobalt-chrome and titanium-alloy spinal implants
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 223-227
Unconstrained testing of spine with bi-axial universal testing machine
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 223-227
Unconstrained testing of spine with bi-axial universal testing machine
- 30 September 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (12) , 3003-3008
Biomechanical Comparison of Krackow Locking Stitch Versus Nonlocking Loop Stitch With Varying Number of Throws
Background: Common suture configuration techniques used for ligament and tendon grafts and repair are the Krackow locking stitch and a nonlocking loop stitch, such as a whipstitch. Clinically, the preferences of orthopaedic surgeons vary. Hypothesis: The Krackow locking stitch and the nonlocking whipstitch, with varying suture loops, produce different biomechanical and physical effects on the tendon end. Study Design: Controlled laboratory study. Methods: A total of 52 fresh-frozen porcine flexor digitorum tendons were used and assigned into 10 groups. Two stitch configurations (Krackow stitch [K] and whipstitch [W]) with varying number of loops (2 throws, n = 6; 4 throws, n = 5; 6 throws, n = 5; 8 throws, n = 5; 10 throws, n = 5) were tested. No. 2 FiberWire was used. Each sample was preloaded to 5 N and then cyclically loaded for 200 cycles to 200 N at 1 Hz, and then the tendon-suture construct was analyzed for gap formation, tendon elongation, and tendon end width. Next, each tendon was loaded to failure, and ultimate strength and mode of failure were recorded. Data were evaluated with 2-way analysis of variance. Results: For gap formation, the Krackow stitch produced less gap compared with the whipstitch (15.2 ± 4.0 mm [K] vs 18.9 ± 6.8 mm [W]; P = .012). Gap formation was larger when the number of loops increased from 2 to ≥6 ( P = .015). For elongation, the Krackow technique increased the tendon length after cyclic loading. In contrast, the whipstitch was noted to shorten the length of the tendon (1.17 ± 0.97 mm [K] vs −0.14 ± 1.13 mm [W]; P < .001). For tendon end width, the Krackow better preserved the transverse width (–0.64 ± 0.81 mm [K] vs −1.39 ± 0.64 mm [W]; P = .001). Both stitch types had similar ultimate strength (322.1 ± 20.3 N [K] vs 319.7 ± 20.4 N [W]; P = .676) and modes of failure (all by suture breakage; therefore, no statistical calculation was performed). There was no statistical difference in tendon elongation, width, failure load, or mode regardless of the number of throws. Conclusion/Clinical Relevance: Given the finding that the Krackow suture had less gap formation and better preservation of tendon architecture (length and width) compared with the whipstitch, coupled with the finding that ultimate strength is similar with both types of sutures, the Krackow stitch is recommended for tendon reconstruction when these parameters are important.
- 30 September 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (12) , 3003-3008
Biomechanical Comparison of Krackow Locking Stitch Versus Nonlocking Loop Stitch With Varying Number of Throws
Background: Common suture configuration techniques used for ligament and tendon grafts and repair are the Krackow locking stitch and a nonlocking loop stitch, such as a whipstitch. Clinically, the preferences of orthopaedic surgeons vary. Hypothesis: The Krackow locking stitch and the nonlocking whipstitch, with varying suture loops, produce different biomechanical and physical effects on the tendon end. Study Design: Controlled laboratory study. Methods: A total of 52 fresh-frozen porcine flexor digitorum tendons were used and assigned into 10 groups. Two stitch configurations (Krackow stitch [K] and whipstitch [W]) with varying number of loops (2 throws, n = 6; 4 throws, n = 5; 6 throws, n = 5; 8 throws, n = 5; 10 throws, n = 5) were tested. No. 2 FiberWire was used. Each sample was preloaded to 5 N and then cyclically loaded for 200 cycles to 200 N at 1 Hz, and then the tendon-suture construct was analyzed for gap formation, tendon elongation, and tendon end width. Next, each tendon was loaded to failure, and ultimate strength and mode of failure were recorded. Data were evaluated with 2-way analysis of variance. Results: For gap formation, the Krackow stitch produced less gap compared with the whipstitch (15.2 ± 4.0 mm [K] vs 18.9 ± 6.8 mm [W]; P = .012). Gap formation was larger when the number of loops increased from 2 to ≥6 ( P = .015). For elongation, the Krackow technique increased the tendon length after cyclic loading. In contrast, the whipstitch was noted to shorten the length of the tendon (1.17 ± 0.97 mm [K] vs −0.14 ± 1.13 mm [W]; P < .001). For tendon end width, the Krackow better preserved the transverse width (–0.64 ± 0.81 mm [K] vs −1.39 ± 0.64 mm [W]; P = .001). Both stitch types had similar ultimate strength (322.1 ± 20.3 N [K] vs 319.7 ± 20.4 N [W]; P = .676) and modes of failure (all by suture breakage; therefore, no statistical calculation was performed). There was no statistical difference in tendon elongation, width, failure load, or mode regardless of the number of throws. Conclusion/Clinical Relevance: Given the finding that the Krackow suture had less gap formation and better preservation of tendon architecture (length and width) compared with the whipstitch, coupled with the finding that ultimate strength is similar with both types of sutures, the Krackow stitch is recommended for tendon reconstruction when these parameters are important.
- 1 September 2014
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 21 (3) , 475-480
Adaptive remodeling at the pedicle due to pars fracture: a finite element analysis study
Spondylolysis is a common condition among the general population and a major cause of back pain in young athletes. This condition can be difficult to detect with plain radiography and has been reported to lead to contralateral pars fracture or pedicle fracture in the terminal stages. Interestingly, some patients with late-stage spondylolysis are observed to have radiographic or CT evidence of a sclerotic pedicle on the side contralateral to the spondylolysis. Although computational studies have shown stress elevation in the contralateral pedicle after a pars fracture, it is not known if these changes would cause sclerotic changes in the contralateral pedicle. The objective of this study was to investigate the adaptive remodeling process at the pedicle due to a contralateral spondylolysis using finite element analysis. A multiscale finite element model of a vertebra was obtained by combining a continuum model of the posterior elements with a voxel-based pedicle section. Extension loading conditions were applied with or without a fracture at the contralateral pars to analyze the stresses in the contralateral pedicle. A remodeling algorithm was used to simulate and assess density changes in the contralateral pedicle. The remodeling algorithm demonstrated an increase in bone formation around the perimeter of the contralateral pedicle with some localized loss of mass in the region of cancellous bone. The authors' results indicated that a pars fracture results in sclerotic changes in the contralateral pedicle. Such a remodeling process could increase overall bone mass. However, focal bone loss in the region of the cancellous bone of the pedicle might predispose the pedicle to microfractures. This phenomenon explains, at least in part, the origin of pedicle stress fractures in the sclerotic contralateral pedicles of patients with unilateral spondylolysis.
- 1 September 2014
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 21 (3) , 475-480
Adaptive remodeling at the pedicle due to pars fracture: a finite element analysis study
Spondylolysis is a common condition among the general population and a major cause of back pain in young athletes. This condition can be difficult to detect with plain radiography and has been reported to lead to contralateral pars fracture or pedicle fracture in the terminal stages. Interestingly, some patients with late-stage spondylolysis are observed to have radiographic or CT evidence of a sclerotic pedicle on the side contralateral to the spondylolysis. Although computational studies have shown stress elevation in the contralateral pedicle after a pars fracture, it is not known if these changes would cause sclerotic changes in the contralateral pedicle. The objective of this study was to investigate the adaptive remodeling process at the pedicle due to a contralateral spondylolysis using finite element analysis. A multiscale finite element model of a vertebra was obtained by combining a continuum model of the posterior elements with a voxel-based pedicle section. Extension loading conditions were applied with or without a fracture at the contralateral pars to analyze the stresses in the contralateral pedicle. A remodeling algorithm was used to simulate and assess density changes in the contralateral pedicle. The remodeling algorithm demonstrated an increase in bone formation around the perimeter of the contralateral pedicle with some localized loss of mass in the region of cancellous bone. The authors' results indicated that a pars fracture results in sclerotic changes in the contralateral pedicle. Such a remodeling process could increase overall bone mass. However, focal bone loss in the region of the cancellous bone of the pedicle might predispose the pedicle to microfractures. This phenomenon explains, at least in part, the origin of pedicle stress fractures in the sclerotic contralateral pedicles of patients with unilateral spondylolysis.
- 1 May 2014
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 20 (5) , 542-549
Load sharing in lumbar spinal segment as a function of location of center of rotation
Object: The center (axis) of rotation (COR) in the lumbar spine has been studied well. However, there is limited information on the kinetic and kinematic consequences of imposed shift in the location of the COR, although this type of shift can be seen after surgeries using motion preservation or dynamic stabilization devices. The objective of this study was to assess the kinetic and kinematic changes in the lumbar spinal segment due to various imposed CORs. Methods: A 3D finite element model of the L4–5 segment was constructed and validated. The segment was loaded under a 7.5-Nm bending moment while constrained to rotate about various imposed CORs in the sagittal and axial motion planes. Range of motion, ligament forces, facet loads, and disc stresses were measured. Results: The present model showed an agreement with previous in vitro and finite element studies under the same load and boundary conditions. Range of motion, facet forces, disc stresses, and ligament loads showed a strong association with the location of the COR. Conclusions: Acute alterations in the location of the COR can significantly change the load sharing characteristics within the spine segment. The normal location of the COR is a result of the tendency of the vertebra to move in the path of least cumulative resistance.
- 1 May 2014
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 20 (5) , 542-549
Load sharing in lumbar spinal segment as a function of location of center of rotation
Object: The center (axis) of rotation (COR) in the lumbar spine has been studied well. However, there is limited information on the kinetic and kinematic consequences of imposed shift in the location of the COR, although this type of shift can be seen after surgeries using motion preservation or dynamic stabilization devices. The objective of this study was to assess the kinetic and kinematic changes in the lumbar spinal segment due to various imposed CORs. Methods: A 3D finite element model of the L4–5 segment was constructed and validated. The segment was loaded under a 7.5-Nm bending moment while constrained to rotate about various imposed CORs in the sagittal and axial motion planes. Range of motion, ligament forces, facet loads, and disc stresses were measured. Results: The present model showed an agreement with previous in vitro and finite element studies under the same load and boundary conditions. Range of motion, facet forces, disc stresses, and ligament loads showed a strong association with the location of the COR. Conclusions: Acute alterations in the location of the COR can significantly change the load sharing characteristics within the spine segment. The normal location of the COR is a result of the tendency of the vertebra to move in the path of least cumulative resistance.
- 1 June 2013
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 18 (6) , 617-626
Instantaneous center of rotation behavior of the lumbar spine with ligament failure
Object: The goal of this study was to investigate the effect of ligament failure on the instantaneous center of rotation (ICR) in the lower lumbar spine. Methods: A 3D finite element model of the L4–5 segment was obtained and validated. Ligament failure was simulated by reducing ligaments in a stepwise manner from posterior to anterior. A pure bending moment of 7.5 Nm was applied to the model in 3 anatomical planes for the purpose of validation, and a 6-Nm moment was applied to analyze the effect of ligament failure. For each loading case, ligament reduction step, and load increment, the range of motion of the segment and the ICR of the mobile (L-4) vertebra were calculated and characterized. Results: The present model showed a consistent increase in the range of motion as the ligaments were removed, which was in agreement with the literature reporting the kinematics of the L4–5 segment. The shift in the location of the ICR was below 5 mm in the sagittal plane and 3 mm in both the axial and coronal planes. Conclusions: The location of the ICR changed in all planes of motion with the simulation of multiple ligament injury. The removal of the ligaments also changed the load sharing within the motion segment. The change in the center of rotation of the spine together with the change in the range of motion could have a diagnostic value, revealing more detailed information on the type of injury, the state of the ligaments, and load transfer and sharing characteristics of the segment.
- 1 June 2013
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 18 (6) , 617-626
Instantaneous center of rotation behavior of the lumbar spine with ligament failure
Object: The goal of this study was to investigate the effect of ligament failure on the instantaneous center of rotation (ICR) in the lower lumbar spine. Methods: A 3D finite element model of the L4–5 segment was obtained and validated. Ligament failure was simulated by reducing ligaments in a stepwise manner from posterior to anterior. A pure bending moment of 7.5 Nm was applied to the model in 3 anatomical planes for the purpose of validation, and a 6-Nm moment was applied to analyze the effect of ligament failure. For each loading case, ligament reduction step, and load increment, the range of motion of the segment and the ICR of the mobile (L-4) vertebra were calculated and characterized. Results: The present model showed a consistent increase in the range of motion as the ligaments were removed, which was in agreement with the literature reporting the kinematics of the L4–5 segment. The shift in the location of the ICR was below 5 mm in the sagittal plane and 3 mm in both the axial and coronal planes. Conclusions: The location of the ICR changed in all planes of motion with the simulation of multiple ligament injury. The removal of the ligaments also changed the load sharing within the motion segment. The change in the center of rotation of the spine together with the change in the range of motion could have a diagnostic value, revealing more detailed information on the type of injury, the state of the ligaments, and load transfer and sharing characteristics of the segment.
- Open Access
- 1 December 2012
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 6 (1) , 8-12
Pullout of a lumbar plate with varying screw lengths
Anterior lumbar interbody fusion (ALIF) is commonly applied in the surgical treatment of degenerative spinal conditions, such as discogenic pain, instability, and spondylolisthesis.1, 2 Important to the successful application of this technique is the maintenance of construct stability until fusion.
- 1 December 2012
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 6 (1) , 8-12
Open AccessPullout of a lumbar plate with varying screw lengths
Anterior lumbar interbody fusion (ALIF) is commonly applied in the surgical treatment of degenerative spinal conditions, such as discogenic pain, instability, and spondylolisthesis.1, 2 Important to the successful application of this technique is the maintenance of construct stability until fusion.
- 24 August 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (7) , 787-791
Multi-scale finite element modelling at the posterior lumbar vertebra: analysis of pedicle stresses due to pars fracture
Multi-scale finite element (FE) model is a cost-effective way to analyse stress response of micro-level structures to the changes in loading at macro-level. This study deals with the development of a multi-scale model of a human vertebra and stress changes in the pedicle at high resolution after a gross fracture at the posterior neural arch. Spondylolysis (pars fracture) is a painful condition occurring in the vertebral neural arch and common especially among the athletic young population. The fracture of the pars significantly alters load distribution and load transfer characteristics at the neural arch. Structural changes in the posterior vertebra due to the new loading patterns can trigger secondary complications. Clinical reports have shown the association of pedicle hypertrophy or pedicle fracture with unilateral pars fractures. However, the biomechanical consequences of pars fracture and its effect on the pedicle have never been studied in detail. Therefore, we prepared a multi-scale model of posterior vertebra with continuum laminar complex model combined with micro-FE model of a pedicle section. The results showed that stress at the contralateral pars and pedicle increased after unilateral pars fracture simulation. High-stress regions were found around the outer boundaries of the pedicle. This model and information are helpful in understanding the stress changes in the pedicle and can be used for adaptive remodelling studies.
- 24 August 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (7) , 787-791
Multi-scale finite element modelling at the posterior lumbar vertebra: analysis of pedicle stresses due to pars fracture
Multi-scale finite element (FE) model is a cost-effective way to analyse stress response of micro-level structures to the changes in loading at macro-level. This study deals with the development of a multi-scale model of a human vertebra and stress changes in the pedicle at high resolution after a gross fracture at the posterior neural arch. Spondylolysis (pars fracture) is a painful condition occurring in the vertebral neural arch and common especially among the athletic young population. The fracture of the pars significantly alters load distribution and load transfer characteristics at the neural arch. Structural changes in the posterior vertebra due to the new loading patterns can trigger secondary complications. Clinical reports have shown the association of pedicle hypertrophy or pedicle fracture with unilateral pars fractures. However, the biomechanical consequences of pars fracture and its effect on the pedicle have never been studied in detail. Therefore, we prepared a multi-scale model of posterior vertebra with continuum laminar complex model combined with micro-FE model of a pedicle section. The results showed that stress at the contralateral pars and pedicle increased after unilateral pars fracture simulation. High-stress regions were found around the outer boundaries of the pedicle. This model and information are helpful in understanding the stress changes in the pedicle and can be used for adaptive remodelling studies.
- 1 July 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (16) , E942-E948
Pullout Analysis of a Lumbar Plate With Varying Screw Orientations
Experimental and finite element analysis of anterior lumbar interbody fixation (ALIF) plate pullout. The objective of this study was to determine the effect of screw angle and orientation on ALIF plate pullout strength. It has been thought that angling the screws in an ALIF plate leads to better fixation strength; however, a few studies are published on this question, which produced conflicting results. Using custom guides, screws were configured in 9 different orientations to affix ALIF plates to polyurethane foam blocks. Pullout tests were performed at a rate of 1 mm/min. In addition, finite element analyses were performed on a 2-dimensional screw-block model to gain insight into the internal stress during pullout. The pullout load was the greatest, with screws positioned 12° outward sagittaly and 6° inward coronally (936 ± 72 N). This orientation was statistically greater than the orientation with the lowest pullout load (812 ± 45 N, P < 0.05); however, no group was statistically different than placing the screws straight in (868 ± 86 N, P > 0.05). Finite elements analysis showed some gain in pullout strength at 12° followed by some loss at greater angles. As the screw insertion angle increased, stress levels elevated within the block even in the regions away from the screw. Significant difference was found between certain screw-angle configurations; however, when compared with simply placing the screws straight in, the difference was never more than 8%. This implies that there is greater freedom in the angle and placement of screws than previously thought. Our results show that there is little change in fixation strength when placing the screw in a different direction.
- 1 July 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (16) , E942-E948
Pullout Analysis of a Lumbar Plate With Varying Screw Orientations
Experimental and finite element analysis of anterior lumbar interbody fixation (ALIF) plate pullout. The objective of this study was to determine the effect of screw angle and orientation on ALIF plate pullout strength. It has been thought that angling the screws in an ALIF plate leads to better fixation strength; however, a few studies are published on this question, which produced conflicting results. Using custom guides, screws were configured in 9 different orientations to affix ALIF plates to polyurethane foam blocks. Pullout tests were performed at a rate of 1 mm/min. In addition, finite element analyses were performed on a 2-dimensional screw-block model to gain insight into the internal stress during pullout. The pullout load was the greatest, with screws positioned 12° outward sagittaly and 6° inward coronally (936 ± 72 N). This orientation was statistically greater than the orientation with the lowest pullout load (812 ± 45 N, P < 0.05); however, no group was statistically different than placing the screws straight in (868 ± 86 N, P > 0.05). Finite elements analysis showed some gain in pullout strength at 12° followed by some loss at greater angles. As the screw insertion angle increased, stress levels elevated within the block even in the regions away from the screw. Significant difference was found between certain screw-angle configurations; however, when compared with simply placing the screws straight in, the difference was never more than 8%. This implies that there is greater freedom in the angle and placement of screws than previously thought. Our results show that there is little change in fixation strength when placing the screw in a different direction.