MCMarco Cacciani

Marco Cacciani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Cacciani has a total of 102 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance Simulation of a Raman Lidar for the Retrieval of CO2 Atmospheric Profiles

    by M. Di Paolantonio, P. Di Girolamo, D. Dionisi, M. Cacciani, A. Di Bernardino, T. Di Iorio, N. Franco, A. M. Iannarelli, G. L. Liberti, D. Summa


  • A Compact Raman Lidar for Atmospheric CO2 and Thermodynamic Profiling: The System CONCERNING

    by Paolo Di Girolamo, Davide Dionisi, Marco Cacciani, Annalisa Di Bernardino, Noemi Franco, Donato Summa, Marco Di Paolantonio, Anna Maria Iannarelli, Tatiana Di Iorio


  • Open Access

    On the Radiative Impact of Biomass-Burning Aerosols in the Arctic: The August 2017 Case Study

    by Filippo Calì Quaglia, Daniela Meloni, Giovanni Muscari, Tatiana Di Iorio, Virginia Ciardini, Giandomenico Pace, Silvia Becagli, Annalisa Di Bernardino, Marco Cacciani, James W. Hannigan, et al.

    Boreal fires have increased during the last years and are projected to become more intense and frequent as a consequence of climate change. Wildfires produce a wide range of effects on the Arctic climate and ecosystem, and understanding these effects is crucial for predicting the future evolution of the Arctic region. This study focuses on the impact of the long-range transport of biomass-burning aerosol into the atmosphere and the corresponding radiative perturbation in the shortwave frequency range. As a case study, we investigate an intense biomass-burning (BB) event which took place in summer 2017 in Canada and subsequent northeastward transport of gases and particles in the plume leading to exceptionally high values (0.86) of Aerosol Optical Depth (AOD) at 500 nm measured in northwestern Greenland on 21 August 2017. This work characterizes the BB plume measured at the Thule High Arctic Atmospheric Observatory (THAAO; 76.53∘N, 68.74∘W) in August 2017 by assessing the associated shortwave aerosol direct radiative impact over the THAAO and extending this evaluation over the broader region (60∘N–80∘N, 110∘W–0∘E). The radiative transfer simulations with MODTRAN6.0 estimated an aerosol heating rate of up to 0.5 K/day in the upper aerosol layer (8–12 km). The direct aerosol radiative effect (ARE) vertical profile shows a maximum negative value of −45.4 Wm−2 for a 78∘ solar zenith angle above THAAO at 3 km altitude. A cumulative surface ARE of −127.5 TW is estimated to have occurred on 21 August 2017 over a portion (∼3.1×106 km2) of the considered domain (60∘N–80∘N, 110∘W–0∘E). ARE regional mean daily values over the same portion of the domain vary between −65 and −25 Wm−2. Although this is a limited temporal event, this effect can have significant influence on the Arctic radiative budget, especially in the anticipated scenario of increasing wildfires.


  • Air Circulation in Urban Areas

    by Annalisa Di Bernardino, Olga Palusci, Agnese Pini, Giovanni Leuzzi, Marco Cacciani, Armando Pelliccioni, Paolo Monti

  • Open Access

    Integrated Evaluation of Indoor Particulate Exposure: The VIEPI Project

    by Armando Pelliccioni, Paolo Monti, Giorgio Cattani, Fabio Boccuni, Marco Cacciani, Silvia Canepari, Pasquale Capone, Maria Catrambone, Mariacarmela Cusano, Maria Concetta D’ovidio, et al.

    Despite the progress made in recent years, reliable modeling of indoor air quality is still far from being obtained. This requires better chemical characterization of the pollutants and airflow physics included in forecasting tools, for which field observations conducted simultaneously indoors and outdoors are essential. The project “Integrated Evaluation of Indoor Particulate Exposure” (VIEPI) aimed at evaluating indoor air quality and exposure to particulate matter (PM) of humans in workplaces. VIEPI ran from February 2016 to December 2019 and included both numerical simulations and field campaigns carried out in universities and research environments located in urban and non-urban sites in the metropolitan area of Rome (Italy). VIEPI focused on the role played by micrometeorology and indoor airflow characteristics in determining indoor PM concentration. Short- and long-term study periods captured diurnal, weekly, and seasonal variability of airflow and PM concentration. Chemical characterization of PM10, including the determination of elements, ions, elemental carbon, organic carbon, and bioaerosol, was also carried out. Large differences in the composition of PM10 were detected between inside and outside as well as between different periods of the day and year. Indoor PM composition was related to the presence of people, to the season, and to the ventilation regime.


  • Open Access

    Water vapor mixing ratio and temperature inter-comparison results in the framework of the Hydrological Cycle in the Mediterranean Experiment—Special Observation Period 1

    by Paolo Di Girolamo, Benedetto De Rosa, Cyrille Flamant, Donato Summa, Olivier Bousquet, Patrick Chazette, Julien Totems, Marco Cacciani

    This paper reports results from an inter-comparison effort involving water vapor and temperature sensors, which took place in the North-Western Mediterranean in the period September–November 2012 in the framework of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment. The involved sensors are the ground-based Raman lidars BASIL and WALI, the airborne water vapor differential absorption lidar LEANDRE 2, flying onboard the ATR42 aircraft, as well as additional water vapor and temperature sensors (radiosondes, aircraft in situ sensors, and a microwave radiometer). The main objective of the inter-comparison is the determination of the measurement uncertainty affecting these sensors. The effort benefitted from dedicated ATR42 flights in the framework of the EUropean Facility for Airborne Research (EUFAR) Project “WaLiTemp.” Comparisons between BASIL and LEANDRE 2 in terms of water vapor mixing ratio indicate a vertically averaged mean bias, $$ \overline{\mathrm{bias}} $$ bias ¯ , and mean absolute bias, $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ , between the two sensors of − 0.08 g kg−1 (or − 2.50%) and 0.67 g kg−1 (or 2.77%), respectively. For all sensors’ pairs including LEANDRE 2, the inter-comparison range is 0.5–3 km, while for all other sensors’ pairs, the inter-comparison range is 0.5–6 km. Comparisons between BASIL and the microwave radiometer indicate $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values between the two sensors of − 0.02 g kg−1 (or − 1.11%) and 0.22 g kg−1 (or 7.31%), respectively, for water vapor mixing ratio measurements, and a value for both $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ of 0.62 K for temperature measurements. Comparisons of BASIL with the radiosondes indicate $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of 0.28 g kg−1 (or 1.56%) and 0.51 g kg−1 (or 6.66%), respectively, for water vapor mixing ratio measurements, and − 0.43 K and 0.77 K, respectively, for temperature measurements, while comparisons of BASIL with aircraft in situ sensors indicate $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of 0.22 g kg−1 (or 1.17%) and 0.43 g kg−1 (or 4.62%), respectively, for water vapor mixing ratio measurements, and 0.15 K and 0.47 K, respectively, for temperature measurements. Comparisons of LEANDRE 2 with the radiosondes result in $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of 0.21 g kg−1 (or 0.76%) and 1.10 g kg−1 (or 11.05%), respectively, while comparisons of LEANDRE 2 with the aircraft in situ sensors indicate a value of both $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ of 0.76 g kg−1 (or 8.9%). Comparisons of in situ sensors with the radiosondes reveal $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of 0.36 g kg−1 (or 2.26%) and 0.36 g kg−1 (or 4.72%), respectively, for water vapor mixing ratio measurements, and 0.61 K and 0.62 K, respectively, for temperature measurements, while comparisons of in situ sensors with the microwave radiometer indicate $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of − 0.37 g kg−1 (or − 2.01%) and 0.58 g kg−1 (or 12.59%), respectively, for water vapor mixing ratio measurements, and a value of both $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ of 0.75 K for temperature measurements. Comparisons of the microwave radiometer with the radiosondes indicate $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values of 0.13 g kg−1 (or 0.83%) and 0.20 g kg−1 (or 17.75%), respectively, for water vapor mixing ratio, and a value of both $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ of 0.74 K for temperature measurements. Our attention was also focused on the water vapor inter-comparison between BASIL and the transportable ground-based Raman lidar WALI, which took place in Candillargues on 30 October 2012, with results indicating $$ \overline{\mathrm{bias}} $$ bias ¯ and $$ \left|\overline{\mathrm{bias}}\right| $$ bias ¯ values between the two sensors of − 0.005 g kg−1 (or − 1.31%) and 0.24 g kg−1 (or 4.32%), respectively. Based on the available dataset and benefiting from the circumstance that BASIL could be compared with all other sensors, the overall bias of all sensors was also estimated. For water vapor mixing ratio measurements, the overall bias is 0.0079 g kg−1, 0.159 g kg−1, 0.084 g kg−1, − 0.201 g kg−1, 0.099 g kg−1, and − 0.141 g kg−1 for BASIL, LEANDRE 2, WALI, the radiosondes, the microwave radiometer, and the aircraft in situ sensor, respectively, being within ± 0.02 g kg−1 for all water vapor sensors. For temperature measurements, the overall bias is 0.11 K, 0.54 K, − 0.04 K, and − 0.51 K for BASIL, the radiosondes, the microwave radiometer, and the aircraft in situ sensor, respectively.


  • Open Access

    Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment – special observation period (hymex-sop1)

    by Donato Summa, Paolo Di Girolamo, Cyrille Flamant, Benedetto De Rosa, Marco Cacciani, Dario Stelitano

    Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL), an airborne DIAL (LEANDRE2), a microwave radiometer, radiosondes and aircraft in-situ sensors.


  • Open Access

    Temperature inter-comparison effort in the framework of Hydrological Cycle in the Mediterranean Experiment – Special Observation Period (HyMeX-SOP1)

    by Benedetto De Rosa, Paolo Di Girolamo, Donato Summa, Cyrille Flamant, Olivier Bousquet, Marco Cacciani, Dario Stelitano

    Accurate measurements of the vertical profiles of atmospheric temperature are necessary to advance the knowledge of dynamics-thermodynamicsradiative interaction mechanisms triggering convection, and ultimately improve weather forecasting capabilities. Comprehensive intercomparisons between different remote sensing and in-situ sensors have to be carried for the purpose of obtaining accurate error estimates for these sensors. This paper reports results obtained in the frame of the Hydrological Cycle in the Mediterranean Experiment – Special Observation Period (HyMeX-SOP1).


  • Open Access

    Clear-air lidar dark band

    by Paolo Di Girolamo, Andrea Scoccione, Marco Cacciani, Donato Summa, Jan H. Schween

    This paper illustrates measurements carried out by the Raman lidar BASIL in the frame of HOPE, revealing the presence of a clear-air dark band phenomenon (i.e. the appearance of a minimum in lidar backscatter echoes) in the upper portion of the convective boundary layer. The phenomenon is clearly distinguishable in the lidar backscatter echoes at 1064 nm. This phenomenon is attributed to the presence of lignite aerosol particles advected from the surrounding open pit mines in the vicinity of the measuring site.

  • Open Access

    Characterization of Boundary Layer Turbulent Processes by the Raman Lidar BASIL in the frame of HD(CP)2) Observational Prototype Experiment

    by Paolo Di Girolamo, Marco Cacciani, Donato Summa, Andrea Scoccione, Benedetto De Rosa, Andreas Behrendt, Volker Wulfmeyer

    Measurements carried out by the University of BASILicata Raman lidar system (BASIL) are reported to demonstrate the capability of this instrument to characterize turbulent processes within the convective boundary layer (CBL). In order to resolve the vertical profiles of turbulent variables, high resolution water vapour and temperature measurements, with a temporal resolution of 10 s and a vertical resolution of 90 m and 30 m, respectively, are considered. Measurements of higher-order moments of the turbulent fluctuations of water vapour mixing ratio and temperature are obtained based on the application of auto-covariance analyses to the water vapour mixing ratio and temperature time series. The algorithms are applied to a case study (11:30–13:30 UTC, 20 April 2013) from the High Definition Clouds and Precipitation for Climate Prediction (HD(CP)2) Observational Prototype Experiment (HOPE), held in Western Germany in the spring 2013. A new correction scheme for the elastic-signal leakage in the low-quantum number rotational Raman signal is applied. The noise errors are small enough to derive up to fourth-order moments for both water vapour mixing ratio and temperature fluctuations. To the best of our knowledge, BASIL is the first Raman lidar with a demonstrated capability to simultaneously retrieve daytime profiles of water vapour turbulent fluctuations up to the fourth order throughout the atmospheric CBL, this capability being combined with the one to also measure daytime profiles of temperature fluctuations up to the fourth order. For the considered case study, which represents a well-mixed and quasi-stationary CBL, the mean boundary layer height is found to be 1290 ± 77 m a.g.l. Values of the integral scale for water vapour and temperature fluctuations at the top of the CBL are in the range of 70–125 s and 75–225 s, respectively; these values are much larger than the temporal resolution of the measurements (10 s), which testifies that the temporal resolution considered for the measurements is sufficiently high to resolve turbulence processes down to the inertial sub-range and consequently resolve the major part of the turbulent fluctuations. Peak values of all moments are found in the interfacial layer in the proximity of the top of the CBL. Specifically, water vapour and temperature second-order moment (variance) has a maximum value of 0.29 g2 kg−2 and 0.26 K2, respectively, water vapour and temperature third-order moment has a peak value of 0.156 g3 kg−3 and −0.067 K3, respectively, while water vapour and temperature fourth-order moment has a maximum value of 0.28 g4 kg−4 and 0.24 K4, respectively. Water vapour and temperature kurtosis have values of ~ 3 in the entrainment zone, which indicate normally distributed humidity and temperature fluctuations. Reported values of the higher-order moments result to be in good agreement with previous measurements at different locations, thus providing confidence on the possibility to use them for turbulence parameterization in weather and climate models. In the determination of the temperature profiles, particular care was dedicated to minimize potential effects associated with elastic signal leakage in the rotational Raman signals. For this purpose, a specific algorithm was defined and tested to identify and remove signal leakages and to assess the residual systematic uncertainty affecting temperature measurements after correction. The application of this approach confirms that for the present Raman lidar system the leakage factor keeps constant with time, and consequently an appropriate assessment of its constant value allows for a complete removal of the leaking elastic signal from the rotational Raman lidar signals at any time (with a residual error on temperature measurements after correction not exceeding 0.16 K).