Shaghayegh Zihajehzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaghayegh Zihajehzadeh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Edward J. Park
School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC, Canada
3 shared publications Darrell Loh
School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC, Canada
2 shared publicationsReynald Hoskinson
School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC, Canada
2 shared publicationsBong-Soo Kang
Department of Mechanical Engineering, Hannam University, Daejeon, South Korea
1 shared publicationEdward J. Park
School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC, Canada
1 shared publicationHamid Abdollahi
Intel Corporation, Vancouver, BC, Canada
1 shared publication
Latest Publications
- 14 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (4) , 1084-1096
Robust Biomechanical Model-Based 3-D Indoor Localization and Tracking Method Using UWB and IMU
This paper proposes a robust sensor fusion algorithm to accurately track the spatial location and motion of a human under various dynamic activities, such as walking, running, and jumping. The position accuracy of the indoor wireless positioning systems frequently suffers from non-line-of-sight and multipath effects, resulting in heavy-tailed outliers and signal outages. We address this problem by integrating the estimates from an ultra-wideband (UWB) system and inertial measurement units, but also taking advantage of the estimated velocity and height obtained from an aiding lower body biomechanical model. The proposed method is a cascaded Kalman filter-based algorithm where the orientation filter is cascaded with the robust position/velocity filter. The outliers are detected for individual measurements using the normalized innovation squared, where the measurement noise covariance is softly scaled to reduce its weight. The positioning accuracy is further improved with the Rauch-Tung-Striebel smoother. The proposed algorithm was validated against an optical motion tracking system for both slow (walking) and dynamic (running and jumping) activities performed in laboratory experiments. The results show that the proposed algorithm can maintain high accuracy for tracking the location of a subject in the presence of the outliers and UWB signal outages with a combined 3-D positioning error of less than 13 cm.
- 14 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (4) , 1084-1096
Robust Biomechanical Model-Based 3-D Indoor Localization and Tracking Method Using UWB and IMU
This paper proposes a robust sensor fusion algorithm to accurately track the spatial location and motion of a human under various dynamic activities, such as walking, running, and jumping. The position accuracy of the indoor wireless positioning systems frequently suffers from non-line-of-sight and multipath effects, resulting in heavy-tailed outliers and signal outages. We address this problem by integrating the estimates from an ultra-wideband (UWB) system and inertial measurement units, but also taking advantage of the estimated velocity and height obtained from an aiding lower body biomechanical model. The proposed method is a cascaded Kalman filter-based algorithm where the orientation filter is cascaded with the robust position/velocity filter. The outliers are detected for individual measurements using the normalized innovation squared, where the measurement noise covariance is softly scaled to reduce its weight. The positioning accuracy is further improved with the Rauch-Tung-Striebel smoother. The proposed algorithm was validated against an optical motion tracking system for both slow (walking) and dynamic (running and jumping) activities performed in laboratory experiments. The results show that the proposed algorithm can maintain high accuracy for tracking the location of a subject in the presence of the outliers and UWB signal outages with a combined 3-D positioning error of less than 13 cm.
- Open Access
- 20 October 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165211
Regression Model-Based Walking Speed Estimation Using Wrist-Worn Inertial Sensor
Walking speed is widely used to study human health status. Wearable inertial measurement units (IMU) are promising tools for the ambulatory measurement of walking speed. Among wearable inertial sensors, the ones worn on the wrist, such as a watch or band, have relatively higher potential to be easily incorporated into daily lifestyle. Using the arm swing motion in walking, this paper proposes a regression model-based method for longitudinal walking speed estimation using a wrist-worn IMU. A novel kinematic variable is proposed, which finds the wrist acceleration in the principal axis (i.e. the direction of the arm swing). This variable (called pca-acc) is obtained by applying sensor fusion on IMU data to find the orientation followed by the use of principal component analysis. An experimental evaluation was performed on 15 healthy young subjects during free walking trials. The experimental results show that the use of the proposed pca-acc variable can significantly improve the walking speed estimation accuracy when compared to the use of raw acceleration information (p<0.01). When Gaussian process regression is used, the resulting walking speed estimation accuracy and precision is about 5.9% and 4.7%, respectively.
- 20 October 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165211
Open AccessRegression Model-Based Walking Speed Estimation Using Wrist-Worn Inertial Sensor
Walking speed is widely used to study human health status. Wearable inertial measurement units (IMU) are promising tools for the ambulatory measurement of walking speed. Among wearable inertial sensors, the ones worn on the wrist, such as a watch or band, have relatively higher potential to be easily incorporated into daily lifestyle. Using the arm swing motion in walking, this paper proposes a regression model-based method for longitudinal walking speed estimation using a wrist-worn IMU. A novel kinematic variable is proposed, which finds the wrist acceleration in the principal axis (i.e. the direction of the arm swing). This variable (called pca-acc) is obtained by applying sensor fusion on IMU data to find the orientation followed by the use of principal component analysis. An experimental evaluation was performed on 15 healthy young subjects during free walking trials. The experimental results show that the use of the proposed pca-acc variable can significantly improve the walking speed estimation accuracy when compared to the use of raw acceleration information (p<0.01). When Gaussian process regression is used, the resulting walking speed estimation accuracy and precision is about 5.9% and 4.7%, respectively.
- 7 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (22) , 8132-8141
Pedestrian Dead Reckoning With Smartglasses and Smartwatch
Wearable miniature inertial sensors have been widely used for pedestrian dead reckoning (PDR). Typical low-cost PDR systems use sensors attached to either the human trunk or feet. The recent emergence of smartglasses and smart watches provides an opportunity to use both types of wearable devices in position tracking. This paper proposes a novel method of utilizing both a smartwatch and smartglasses for PDR. The general idea is to use the relative angle between arm swing direction and head direction to detect any head-turn motion that would otherwise skew the position dead reckoning propagation. A complete PDR solution that includes step detection, step length estimation, head-rotation detection, and dead reckoning using a smartwatch and smartglasses that are currently available in the market is presented. Using the smartglasses, step detection with an error rate less than 0.4% and a cumulative distance error of less than 2.4% on 800 m walks and runs is achieved. In the dead reckoning field experiments, the proposed algorithm produces result that closely track the actual path when plotted on Google Maps, outperforming solutions that only use the smartwatch or smartglasses alone.
- 7 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (22) , 8132-8141
Pedestrian Dead Reckoning With Smartglasses and Smartwatch
Wearable miniature inertial sensors have been widely used for pedestrian dead reckoning (PDR). Typical low-cost PDR systems use sensors attached to either the human trunk or feet. The recent emergence of smartglasses and smart watches provides an opportunity to use both types of wearable devices in position tracking. This paper proposes a novel method of utilizing both a smartwatch and smartglasses for PDR. The general idea is to use the relative angle between arm swing direction and head direction to detect any head-turn motion that would otherwise skew the position dead reckoning propagation. A complete PDR solution that includes step detection, step length estimation, head-rotation detection, and dead reckoning using a smartwatch and smartglasses that are currently available in the market is presented. Using the smartglasses, step detection with an error rate less than 0.4% and a cumulative distance error of less than 2.4% on 800 m walks and runs is achieved. In the dead reckoning field experiments, the proposed algorithm produces result that closely track the actual path when plotted on Google Maps, outperforming solutions that only use the smartwatch or smartglasses alone.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 502-505
Fitness activity classification by using multiclass support vector machines on head-worn sensors
Fitness activity classification on wearable devices can provide activity-specific information and generate more accurate performance metrics. Recently, optical head-mounted displays (OHMD) like Google Glass, Sony SmartEyeglass and Recon Jet have emerged. This paper presents a novel method to classify fitness activities using head-worn accelerometer, barometric pressure sensor and GPS, with comparisons to other common mounting locations on the body. Using multiclass SVM on head-worn sensors, we obtained an average F-score of 96.66% for classifying standing, walking, running, ascending/descending stairs and cycling. The best sensor location combinations were found to be on the ankle plus another upper body location. Using three or more sensors did not show a notable improvement over the best two-sensor combinations.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 502-505
Fitness activity classification by using multiclass support vector machines on head-worn sensors
Fitness activity classification on wearable devices can provide activity-specific information and generate more accurate performance metrics. Recently, optical head-mounted displays (OHMD) like Google Glass, Sony SmartEyeglass and Recon Jet have emerged. This paper presents a novel method to classify fitness activities using head-worn accelerometer, barometric pressure sensor and GPS, with comparisons to other common mounting locations on the body. Using multiclass SVM on head-worn sensors, we obtained an average F-score of 96.66% for classifying standing, walking, running, ascending/descending stairs and cycling. The best sensor location combinations were found to be on the ankle plus another upper body location. Using three or more sensors did not show a notable improvement over the best two-sensor combinations.