Nancy A. Obuchowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nancy A. Obuchowski has a total of 689 co-authors. Here are the top co-authors by number of shared publications:
- Carl S. Winalski
Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic Cleveland Ohio USA
6 shared publications - Xiaojuan Li
Cleveland Clinic, USA
5 shared publications - Andrew J. Buckler
Elucid Bioimaging Inc., Wenham, MA, USA
4 shared publications - Kurt P. Spindler
Cleveland Clinic Foundation, Cleveland, Ohio, USA
4 shared publications - Morgan H. Jones
Brigham and Women's Hospital and Harvard Medical School Boston Massachusetts
4 shared publications - Paul Eugene Kinahan
Department of Radiology University of Washington Seattle Washington USA
4 shared publications
Latest Publications
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 321 (1)
Artificial Intelligence for Prostate Cancer Detection and Screening on MRI in Global Populations: The SCARLET-1 Study
In this study of 22,445 prostate MRI examinations from 22 countries, an AI system’s performance was comparable to radiology readings for prostate cancer detection in external diagnostic and screening datasets.
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 321 (1)
Artificial Intelligence for Prostate Cancer Detection and Screening on MRI in Global Populations: The SCARLET-1 Study
In this study of 22,445 prostate MRI examinations from 22 countries, an AI system’s performance was comparable to radiology readings for prostate cancer detection in external diagnostic and screening datasets.
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 321 (1)
Standardizing Liver MR Elastography: Guidelines for Reliable Stiffness Measurement in Chronic Liver Disease
Standardized MR elastography enables reliable liver stiffness measurement, with a change of at least 19% reflecting a true biological difference with 95% confidence, supporting longitudinal assessment of chronic liver disease.
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 321 (1)
Standardizing Liver MR Elastography: Guidelines for Reliable Stiffness Measurement in Chronic Liver Disease
Standardized MR elastography enables reliable liver stiffness measurement, with a change of at least 19% reflecting a true biological difference with 95% confidence, supporting longitudinal assessment of chronic liver disease.
- Open Access
- 21 November 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 199, 111321
Scalable Clinical Annotation with Location Evidence (SCALE)
- 21 November 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 199, 111321
Open AccessScalable Clinical Annotation with Location Evidence (SCALE)
- 1 August 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 316 (2) , e250279
Understanding Repeatability and Reproducibility Coefficients for Quantitative Imaging Biomarkers
- 1 August 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 316 (2) , e250279
Understanding Repeatability and Reproducibility Coefficients for Quantitative Imaging Biomarkers
- Open Access
- 1 July 2025
- Published by SAGE Publications in Multiple Sclerosis Journal – Experimental, Translational and Clinical
- Vol. 11 (3)
Diffusion tensor imaging in the SPRINT-MS clinical trial: Advancing trial methodology
Background: SPRINT-MS was a placebo-controlled phase 2 trial of ibudilast in secondary and primary progressive multiple sclerosis. The trial included multimodal imaging to assess brain tissue integrity. This contribution focuses on improved analysis methods of diffusion tensor imaging to refine its application in clinical trials. Objective: Reassess diffusion tensor imaging from the SPRINT-MS trial. Methods: Postprocessing incorporated corrections for bulk motion, eddy current distortion, outlier replacement, and intra-volume movement. The ICBM-DTI-81 white matter parcellation map was coregistered into native space. Six unilateral and 21 bilateral regions of interest were identified. Median radial diffusivity was the primary outcome measure for this analysis. A linear mixed-effects model was used to assess the interaction between time and treatment for the outcome measure with Holm correction for multiple comparisons. Results: Radial diffusivity in the cingulum and cerebellar peduncles showed a significant difference in rate of change between treatment and placebo groups (2.7–7.4 × 10 −3 mm 2 /s per 24-week time period, p < 0.04). Radial diffusivity was unchanged (declined) in the treatment (placebo) groups, consistent with preservation (deterioration) of tissue integrity. Conclusion: Our results suggest that the diffusion tensor imaging of the cingulum and cerebellar peduncles may be useful target outcome metrics in neuroprotective trials in progressive multiple sclerosis.
- 1 July 2025
- Published by SAGE Publications in Multiple Sclerosis Journal – Experimental, Translational and Clinical
- Vol. 11 (3)
Open AccessDiffusion tensor imaging in the SPRINT-MS clinical trial: Advancing trial methodology
Background: SPRINT-MS was a placebo-controlled phase 2 trial of ibudilast in secondary and primary progressive multiple sclerosis. The trial included multimodal imaging to assess brain tissue integrity. This contribution focuses on improved analysis methods of diffusion tensor imaging to refine its application in clinical trials. Objective: Reassess diffusion tensor imaging from the SPRINT-MS trial. Methods: Postprocessing incorporated corrections for bulk motion, eddy current distortion, outlier replacement, and intra-volume movement. The ICBM-DTI-81 white matter parcellation map was coregistered into native space. Six unilateral and 21 bilateral regions of interest were identified. Median radial diffusivity was the primary outcome measure for this analysis. A linear mixed-effects model was used to assess the interaction between time and treatment for the outcome measure with Holm correction for multiple comparisons. Results: Radial diffusivity in the cingulum and cerebellar peduncles showed a significant difference in rate of change between treatment and placebo groups (2.7–7.4 × 10 −3 mm 2 /s per 24-week time period, p < 0.04). Radial diffusivity was unchanged (declined) in the treatment (placebo) groups, consistent with preservation (deterioration) of tissue integrity. Conclusion: Our results suggest that the diffusion tensor imaging of the cingulum and cerebellar peduncles may be useful target outcome metrics in neuroprotective trials in progressive multiple sclerosis.
- Open Access
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (3) , 1308-1320
CTLESS: A Scatter-Window Projection and Deep Learning-Based Transmission-Less Attenuation Compensation Method for Myocardial Perfusion SPECT
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis in case of misalignment between SPECT and CT images. To address these issues, we developed a method for cardiac SPECT AC using deep learning and emission scatter-window photons without a separate transmission scan (CTLESS). In this method, an estimated attenuation map reconstructed from scatter-energy window projections is segmented into different regions using a multi-channel input multi-decoder network trained on CT scans. Pre-defined attenuation coefficients are assigned to these regions, yielding the attenuation map used for AC. We objectively evaluated this method in a retrospective study with anonymized clinical SPECT/CT stress MPI images on the clinical task of detecting perfusion defects with an anthropomorphic model observer. CTLESS yielded statistically non-inferior performance compared to a CT-based AC (CTAC) method and significantly outperformed a non-AC (NAC) method on this clinical task. Similar results were observed in stratified analyses with different sexes, defect extents, and defect severities. The method was observed to generalize across two SPECT scanners, each with a different camera. In addition, CTLESS yielded similar performance as CTAC and outperformed NAC method on the fidelity-based figures of merit, namely, root mean squared error (RMSE) and structural similarity index measure (SSIM). Moreover, as we reduced the training dataset size, CTLESS yielded relatively stable AUC values and generally outperformed another DL-based AC method that directly estimated the attenuation coefficient within each voxel. These results demonstrate the capability of the CTLESS method for transmission-less AC in SPECT and motivate further clinical evaluation.
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (3) , 1308-1320
Open AccessCTLESS: A Scatter-Window Projection and Deep Learning-Based Transmission-Less Attenuation Compensation Method for Myocardial Perfusion SPECT
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis in case of misalignment between SPECT and CT images. To address these issues, we developed a method for cardiac SPECT AC using deep learning and emission scatter-window photons without a separate transmission scan (CTLESS). In this method, an estimated attenuation map reconstructed from scatter-energy window projections is segmented into different regions using a multi-channel input multi-decoder network trained on CT scans. Pre-defined attenuation coefficients are assigned to these regions, yielding the attenuation map used for AC. We objectively evaluated this method in a retrospective study with anonymized clinical SPECT/CT stress MPI images on the clinical task of detecting perfusion defects with an anthropomorphic model observer. CTLESS yielded statistically non-inferior performance compared to a CT-based AC (CTAC) method and significantly outperformed a non-AC (NAC) method on this clinical task. Similar results were observed in stratified analyses with different sexes, defect extents, and defect severities. The method was observed to generalize across two SPECT scanners, each with a different camera. In addition, CTLESS yielded similar performance as CTAC and outperformed NAC method on the fidelity-based figures of merit, namely, root mean squared error (RMSE) and structural similarity index measure (SSIM). Moreover, as we reduced the training dataset size, CTLESS yielded relatively stable AUC values and generally outperformed another DL-based AC method that directly estimated the attenuation coefficient within each voxel. These results demonstrate the capability of the CTLESS method for transmission-less AC in SPECT and motivate further clinical evaluation.
- 9 October 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (1) , 31-39.e2
Liver Vein Deprivation versus Portal Vein Embolization: Retrospective Review of Safety and Effectiveness
- 9 October 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (1) , 31-39.e2
Liver Vein Deprivation versus Portal Vein Embolization: Retrospective Review of Safety and Effectiveness
- 1 October 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (1) , e233055
The QIBA Profile for Diffusion-Weighted MRI: Apparent Diffusion Coefficient as a Quantitative Imaging Biomarker
The claims and procedures of the Quantitative Imaging Biomarker Alliance Diffusion-Weighted Imaging Biomarker Committee are summarized for apparent diffusion coefficient as a quantitative biomarker to monitor lesions in the brain, liver, prostate, and breast.
- 1 October 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (1) , e233055
The QIBA Profile for Diffusion-Weighted MRI: Apparent Diffusion Coefficient as a Quantitative Imaging Biomarker
The claims and procedures of the Quantitative Imaging Biomarker Alliance Diffusion-Weighted Imaging Biomarker Committee are summarized for apparent diffusion coefficient as a quantitative biomarker to monitor lesions in the brain, liver, prostate, and breast.
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (3) , e233094
Reproducibility and Repeatability of US Shear-Wave and Transient Elastography in Nonalcoholic Fatty Liver Disease
This prospective study defines expected US elastography measurement variability to guide clinical interpretation, enable diagnostic enrichment in clinical trials, and support U.S. Food and Drug Administration biomarker validation for nonalcoholic fatty liver disease.
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (3) , e233094
Reproducibility and Repeatability of US Shear-Wave and Transient Elastography in Nonalcoholic Fatty Liver Disease
This prospective study defines expected US elastography measurement variability to guide clinical interpretation, enable diagnostic enrichment in clinical trials, and support U.S. Food and Drug Administration biomarker validation for nonalcoholic fatty liver disease.
- Top Cited PapersOpen Access
- 17 January 2024
- Published by Springer Nature in Insights into Imaging
- Vol. 15 (1) , 1-18
METhodological RadiomICs Score (METRICS): a quality scoring tool for radiomics research endorsed by EuSoMII
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical
- 17 January 2024
- Published by Springer Nature in Insights into Imaging
- Vol. 15 (1) , 1-18
Top Cited PapersOpen AccessMEThodological RadiomICs Score (METRICS): a quality scoring tool for radiomics research endorsed by EuSoMII
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical