BXBin Xie

Bin Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bin Xie has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Coordinated Power Mutual Support Control for Multiport Hybrid AC/DC Microgrids

    by Li He, Yong Li, Changfeng Liao, Bin Xie, Chaoyang Chen, Yijia Cao

    Ensuring the frequency and voltage stability of multi sub-grids are urgent for the hybrid microgrid’s stable operation. In this article, a model predictive control (MPC) based cross-grid power coordinated control strategy is proposed. First, according to the topology of multiport hybrid microgrid, the conventional ac–dc coupling characteristics are analyzed, and a different coupling analysis method considering energy conservation and capacity difference is introduced. Then, the regulation demands when multi sub-grids encounter net power changes are analyzed in detail, based on which the designing principles of the proposed strategy are elaborated. Further, the state space models of ac and dc sub-grids are built separately based on their respective physical characteristics, derived from which the hybrid microgrid model is obtained and serves for the control scheme design. Subsequently, a novel mutual support power control strategy based on MPC is proposed, of which the implementation procedure is elaborated, the key parameters are discussed, and the stability is theoretically analyzed. The proposed strategy can achieve good performance of frequency and voltage regulations with less cross-grid power transmission. The performance of the proposed control strategy is validated by the hardware-in-loop (HIL) experiments based on RT-LAB platform.

  • An Energy Storage-Based Railway Power Flow Controller With Partial Compensation Strategy

    by Jinjie Lin, Sixiang Lin, Yong Li, Sijia Hu, Jing Zhang, Jie Zhang, Bonan An, Zhiwen Zhang, Bin Xie, Fangyuan Zhou, et al.

    Focusing on the grid-connection issues and the generated regenerative braking energy (RBE) in the traction power supply system (TPSS), this paper proposes an energy storage-based railway power flow controller (ES-RPFC) with partial compensation strategy (PCS) for grid-connection performance improvement and RBE utilization. The relationship of the primary power factor (PF), the two-phase compensated power, and the converters' rating is investigated. On this basis, a PCS is developed to reduce the converters' rating under the premise of satisfying the concerned grid-connection indices. Then, taking the developed PCS into account, a comprehensive power-flow management scheme for ES-RPFC under different operation scenarios is established, and the control strategy of the converter-level controller is given. Finally, the proposal is verified to be feasible and effective by means of both simulation and hardware-in-loop (HIL) experimental results.


  • A New DC Multipulse Integrated Shipboard Power Supply System and Performance Analysis Referring to Transformer Noninteger Turns Ratio Deviation

    by Bonan An, Yong Li, Bin Xie, Hua Xiao, Wei Zuo, Longfu Luo, Yijia Cao

    The shipboard power supply system contributes to the next-generation vessels development. In this sense, based on the magnetic-integrated multipulse converter transformer (MI-MPCT), a new dc-multipulse-integrated shipboard power supply system (dc-MISPSS) is proposed in this article, with the expectations of reducing volume, improving power quality, whilst mitigating vibration and noise of a rectifier transformer. Benefited from the magnetic-integrated technology, the MI-MPCT with small size and low cost is introduced into the dc-MISPSS, and the volume of the novel system is expected to be decreased significantly. In addition, to explore some certain standards and references for engineering application, the typical power quality indexes of dc-MISPSS are calculated quantitatively. Especially considering the MI-MPCT noninteger turns ratio deviation in practice, the actual system performances are also analyzed. Furthermore, based on the high-capacity engineering prototype, the simulated and experimental results validate that the dc-MISPSS performs well on harmonic elimination, circulation-currents suppression, and dc-voltage ripple restraint. Synthesizing theoretical analysis and experimental results, dc-MISPSS is suitable for industrial application in vessels.


  • Open Access

    A Novel Harmonic Suppression Traction Transformer with Integrated Filtering Inductors for Railway Systems

    by Yuxing Liu, Jiazhu Xu, Zhikang Shuai, Yong Li, Yanjian Peng, Chonggan Liang, Guiping Cui, Sijia Hu, Mingmin Zhang, Bin Xie

    This study analyzes and evaluates the feasibility of a harmonic suppression traction transformer (HSTT) for harmonic reduction in railway systems. This new type of transformer can improve the power quality of railway systems by preventing high-frequency harmonic currents from injecting into the traction grid. As the physical size of available space in high-speed trains is strictly limited, low space-occupying filtering techniques are needed. Therefore, an HSTT with integrated filtering inductors (IFIs) capable of being implemented in regular trains is proposed. Taking advantage of the HSTT, a specially constructed inductive-capacitive-inductive (LCL)-type filter is used for harmonic suppression instead of a regular LCL-type filter. The proposed filter is composed of an integrated inductor, leakage inductor of the traction transformer, and an external filter capacitor. In this paper, we analyze the topology of the proposed system, construct a mathematical model to reveal the magnetic decoupling theory of IFIs, and discuss the design and calculation procedures of the HSTT with IFIs. The field circuit coupling simulation of the HSTT with IFIs is performed to validate the effectiveness of the proposed system. Finally, the practical operation based on a 10 kVA prototype shows that the proposed scheme can not only suppress the high-order frequency harmonics but also decrease the installed space of filter devices.


  • Magnetic-Integrated Multipulse Rectifier Transformer With a Tight Impedance Equalizing Strategy for Power Quality Improvement of DC Traction Power Supply System

    by Bonan An, Yong Li, Hua Xiao, Bin Xie, Pengcheng Wang, Mengxia Wang, Longfu Luo

    To improve the power quality of dc traction power supply system (DC-TPSS), a magnetic-integrated multi-pulse rectifier trans-former (MI-MPRT) with a tight impedance equalizing strategy is proposed in this paper. The configuration and winding-arrangement of MI-MPRT are introduced, and by integrating multiple windings on a same iron core, the volume and cost of proposed transformer can be decreased significantly. Cooperated with staggered winding-arrangement, a tight impedance equalizing strategy is proposed to optimize the winding thickness and insulation distance comprehensively, and MI-MPRT would be designed in a minimum axial dimension, with equalizing short-circuit impedance of each winding. A high-power prototype is manufactured, and the efficiency and effectively of prototype are verified by the transformer standard test. In addition, the DC-TPSS based MI-MPRT is implemented, and the experiment results validate that the power quality of new system can be im-proved significantly by harmonic elimination, circulation-currents suppression and dc-voltage ripple restraint. Both the theoretical and experimental results indicate that the proposed MI-MPRT is suitable for power quality improvement and industrial application in DC-TPSS.


  • Supercapacitor Integrated Railway Static Power Conditioner for Regenerative Braking Energy Recycling and Power Quality Improvement of High-Speed Railway System

    by Guiping Cui, Longfu Luo, Chonggan Liang, Sijia Hu, Yong Li, Yijia Cao, Bin Xie, Jiazhu Xu, Zhiwen Zhang, Yuxing Liu, et al.

    In order to increase the utilization rate of regenerative braking energy (RBE), reduce the operation cost and improve the power quality of traction power supply system (TPSS) in high-speed railway, a supercapacitor (SC) based energy storage system (SCESS) integrated railway static power conditioner (RPC) is presented in this paper. In this scheme, the SC is connected onto the dc-link of the RPC via a bidirectional dc-dc converter. A hierarchical control strategy, with an energy management layer and a converter control layer, is presented. Four operation modes and transition conditions of the SCESS-RPC are elaborated in detail in the energy management layer. To obtain rapid and stable control performance, in the converter control layer, a passivity-based control (PBC) based nonlinear controller is designed for the RPC, and an optimal control strategy based on linear quadratic regulator with integral action (LQRI) is adopted for the bidirectional dc-dc converter. By means of simulations and experiments the feasibility of the proposed topology and control strategy are verified.


  • An Asymmetrical Connection Balance Transformer-Based Hybrid Railway Power Conditioning System With Cost-Function Optimization

    by Bonan An, Yong Li, Fang Liu, Bin Xie, Sijia Hu, Pengcheng Wang, Zhixue Zhang, Longfu Luo, Yijia Cao

    For solving the emerging power quality problems in electrified railway, an asymmetrical connection balance transformer based hybrid railway power conditioning system with cost-function optimization (ACBT-HRPC) is proposed in this paper. Compared with other balanced traction transformers, the asymmetrical connection balance transformer (ACBT) is characterized with a much higher material utilization, which really matters in practical applications. Besides, the inductively filtered rectifier transformer (IFRT), with filter tuned (FT) branches used for filtering harmonics and compensating reactive power, is used as a coupling stage of hybrid railway power conditioning system. The mathematical relationship between power factor (PF) and design capacity is analyzed, and the cost-function optimization has been proposed to minimize the investment of ACBT-HRPC, which enables a satisfactory compensation performance with relatively attractive costs. Both the simulation and experimental results verify the effectiveness of ACBT-HRPC.


  • A Balance Transformer-Integrated RPFC for Railway Power System PQ Improvement With Low-Design Capacity

    by Sijia Hu, Sheng Li, Yong Li, Olav Krause, Bin Xie, Bonan An, Pengcheng Wang, Zhiwen Zhang, Longfu Luo

    This paper gives the fundamental aspects of a power distribution scheme on railway power flow controller (RPFC) for the grid connection compatibility improvement in planning stage railway power system (RPS) via neatly adjusting the value and rotation direction of the primary three-phase current phasors for every given power factor and random load point. This method not only leads RPS to satisfy the relevant grid connection standards, but also can make RPFC have minimum designing capacity and high operating efficiency to decrease its costs in system planning stage. The analytic design method and the experimental results validate the correctness of the conception. The method of using this idea in more challenging serviced RPS will be discussed in another companion volume.


  • A Compensation System for Cophase High-Speed Electric Railways by Reactive Power Generation of SHC&SAC

    by Bin Xie, Yong Li, Zhiwen Zhang, Sijia Hu, Zhixue Zhang, Longfu Luo, Yijia Cao, Fangyuan Zhou, Renjun Luo, Lilan Long

    In this paper, a system with series hybrid converter and shunt active converter (SHC&SAC) for compensation in co-phase high-speed electric railways is proposed. Unlike the general power flow conditioners, the dc-links of the two converters are separated, and therefore, the two converters can operate independently. Just by taking the advantage of the reactive power generation ability and novel connection of SHC&SAC, the grid-side power factor can be improved and negative-sequence current can be suppressed, especially on the cases of high-speed trains. Besides, because of the capacitor in SHC, the active capacity of SHC is significantly lower than that of SAC. To obtain a good current tracking performance, the passive control method, which is based on the dissipation characteristic of resistor, is adopted for controlling converters. And finally, the effectiveness of the system is verified by simulation and experimental results.