Ram Niwash Mahia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ram Niwash Mahia has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Deepak Fulwani
Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
8 shared publications Mahaveer Singh
Defence Research and Development Organization (DRDO) Jodhpur
6 shared publications- Manish Kumar Pandey
Department of Electrical Engineering, National Institute of Technology Hamirpur, Hamirpur, India
3 shared publications - Om Prakash Mahela
Rajasthan Rajya Vidyut Prasaran Nigam Ltd
2 shared publications - Ark Dev
SR University
1 shared publication - Rajat Kumar
NIT Hamirpur
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 23 (2) , 203-226
Dynamic load frequency regulation in two area power systems via pelican-optimized PID control
This article presents Pelican Optimization Algorithm (POA) for Load Frequency Control (LFC) in two area interconnected power systems. Extensive simulations in MATLindicate that the POA surpasses numerous established metaheuristic optimization algorithms, involving the Grey Wolf Optimizer (GWO), Hippopotamus Optimization Algorithm (HOA), Salp Swarm Algorithm (SSA), Particle Swarm Optimization (PSO), Teaching-Learning Optimization Algorithm (TLOA) and Whale Optimization Algorithm (WOA) regarding the mitigation of frequency deviations and improvement of dynamic response. The robustness of the POA based LFC is validated under scenarios of random load disturbances, varying system parameters, typical power system nonlinearities like generation rate constraints (GRC) and governor deadband (GDB), and with renewable energy sources. The studies highlighted in the article demonstrate superior adaptability and effectiveness of POA to optimally tune the gains of PID controller. The statistical analysis demonstrate that the proposed POA achieves convergence to the global optimum with reduced execution time ( : 12% less than the second best HOA) and exhibits lower mean (~15.2% less than the second best SSA) and standard deviation (~3.09% less than the second best HOA) over multiple independent runs. Stability analysis using Bode plots confirms that the proposed control strategy maintains adequate stability margins.
- 1 January 2026
- Published by National Library of Serbia in Serbian Journal of Electrical Engineering
- Vol. 23 (2) , 203-226
Open AccessDynamic load frequency regulation in two area power systems via pelican-optimized PID control
This article presents Pelican Optimization Algorithm (POA) for Load Frequency Control (LFC) in two area interconnected power systems. Extensive simulations in MATLindicate that the POA surpasses numerous established metaheuristic optimization algorithms, involving the Grey Wolf Optimizer (GWO), Hippopotamus Optimization Algorithm (HOA), Salp Swarm Algorithm (SSA), Particle Swarm Optimization (PSO), Teaching-Learning Optimization Algorithm (TLOA) and Whale Optimization Algorithm (WOA) regarding the mitigation of frequency deviations and improvement of dynamic response. The robustness of the POA based LFC is validated under scenarios of random load disturbances, varying system parameters, typical power system nonlinearities like generation rate constraints (GRC) and governor deadband (GDB), and with renewable energy sources. The studies highlighted in the article demonstrate superior adaptability and effectiveness of POA to optimally tune the gains of PID controller. The statistical analysis demonstrate that the proposed POA achieves convergence to the global optimum with reduced execution time ( : 12% less than the second best HOA) and exhibits lower mean (~15.2% less than the second best SSA) and standard deviation (~3.09% less than the second best HOA) over multiple independent runs. Stability analysis using Bode plots confirms that the proposed control strategy maintains adequate stability margins.
- 24 September 2025
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 46 (1)
Golden Jackal Optimization tuned PID control for multi source two area interconnected energy system frequency stability
- 24 September 2025
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 46 (1)
Golden Jackal Optimization tuned PID control for multi source two area interconnected energy system frequency stability
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 351-355
Mitigation of Renewable Power Evacuation Constraints in Practical Utility Grid by Restricting Power Flow on the EHV AC Transmission Lines
The power flow constraints in a transmission system can be obviated by effective use of the flexible alternating current transmission systems (FACTS). This paper investigates the use of power flow control devices (PFCD) to mitigate solar power evacuation constraints associated with a 400 kV Substation. This is achieved by change in the reactance of the 220 kV transmission lines. A load flow study is performed considering all elements of the investigated transmission system and different values of reactance is computed which can be inserted in the line using a PFCD. Proposed PFCD considering the computed values of reactance are effective to restrict power flow on the transmission lines within permissible limits. Study is performed using MiPower software.
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 351-355
Mitigation of Renewable Power Evacuation Constraints in Practical Utility Grid by Restricting Power Flow on the EHV AC Transmission Lines
The power flow constraints in a transmission system can be obviated by effective use of the flexible alternating current transmission systems (FACTS). This paper investigates the use of power flow control devices (PFCD) to mitigate solar power evacuation constraints associated with a 400 kV Substation. This is achieved by change in the reactance of the 220 kV transmission lines. A load flow study is performed considering all elements of the investigated transmission system and different values of reactance is computed which can be inserted in the line using a PFCD. Proposed PFCD considering the computed values of reactance are effective to restrict power flow on the transmission lines within permissible limits. Study is performed using MiPower software.
- 3 November 2023
- Published by Springer Nature
- p. 233-246
Application of SEPIC Converter to Developed Electric Vehicle Charging Station Based on PV Source
- 3 November 2023
- Published by Springer Nature
- p. 233-246
Application of SEPIC Converter to Developed Electric Vehicle Charging Station Based on PV Source
- 17 January 2018
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 16 (1) , 97-107
Identification of Optimal Set of Driver Nodes in Complex Networked Systems Using Region of Attraction
- 17 January 2018
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 16 (1) , 97-107
Identification of Optimal Set of Driver Nodes in Complex Networked Systems Using Region of Attraction
- 23 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (2) , 216-220
On Some Input–Output Dynamic Properties of Complex Networks
In this work we obtain relationship between dynamic properties of system and network structure of complex network. We show that the sum of product of weights of all shortest paths between control and output nodes is equal to the Gain Factor of the pole-zero-gain transfer function of the complex network. We also show that DC-Gain for the peripheral nodes of the complex network depends on the distance between the control and output nodes in the network. Existence of nonminimum phase zeros for collocated control and output nodes is discussed. The theoretical developments are verified using IEEE- 4 bus power networked system application.
- 23 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (2) , 216-220
On Some Input–Output Dynamic Properties of Complex Networks
In this work we obtain relationship between dynamic properties of system and network structure of complex network. We show that the sum of product of weights of all shortest paths between control and output nodes is equal to the Gain Factor of the pole-zero-gain transfer function of the complex network. We also show that DC-Gain for the peripheral nodes of the complex network depends on the distance between the control and output nodes in the network. Existence of nonminimum phase zeros for collocated control and output nodes is discussed. The theoretical developments are verified using IEEE- 4 bus power networked system application.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 332-337
Selection of optimal set of driver nodes based on networked sensitivity in complex networked systems
In this paper, we investigate the correlation between optimal set of driver nodes and networked sensitivity of Complex Networked Systems (CNS). Here, we study the networked sensitivity between a pair of control and output nodes for interconnected directed and undirected networks. We investigate the importance of the optimal driver nodes based on new index of the networked control system, which is networked sensitivity in the networked system. In this paper, we discuss to select the optimal set of driver nodes corresponding to minimum networked sensitivity w.r.t. (i) maximum DC-Gain and (ii) a range of frequency. In particular, we develop an algorithm to select the optimal set of driver nodes which has minimum networked sensitivity. Finally, we validate theoretical results with the help of network examples.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 332-337
Selection of optimal set of driver nodes based on networked sensitivity in complex networked systems
In this paper, we investigate the correlation between optimal set of driver nodes and networked sensitivity of Complex Networked Systems (CNS). Here, we study the networked sensitivity between a pair of control and output nodes for interconnected directed and undirected networks. We investigate the importance of the optimal driver nodes based on new index of the networked control system, which is networked sensitivity in the networked system. In this paper, we discuss to select the optimal set of driver nodes corresponding to minimum networked sensitivity w.r.t. (i) maximum DC-Gain and (ii) a range of frequency. In particular, we develop an algorithm to select the optimal set of driver nodes which has minimum networked sensitivity. Finally, we validate theoretical results with the help of network examples.
- 1 August 2016
- Published by Elsevier in Neurocomputing
- Vol. 201, 104-111
Towards characterization of driver nodes in complex network with actuator saturation
- 1 August 2016
- Published by Elsevier in Neurocomputing
- Vol. 201, 104-111
Towards characterization of driver nodes in complex network with actuator saturation
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 188-193
Selection of driver nodes based on region of attraction for single-input complex networks
This paper presents a theory and algorithms to select an appropriate driver node based on region of attraction (ROA) of single-input complex networks considering limited capacity of driver node. A single-input complex network is called controllable network if it can be driven from any initial state to desired state within finite time in n dimensional state space using a driver node. A driver node through which a network can be controlled is not unique. Non-uniqueness of driver node poses a challenge to select a right driver node when multiple possibilities exist. It is important to characterize these driver nodes and select the right driver node. In this paper, we consider a single-input unstable network with saturated actuator.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 188-193
Selection of driver nodes based on region of attraction for single-input complex networks
This paper presents a theory and algorithms to select an appropriate driver node based on region of attraction (ROA) of single-input complex networks considering limited capacity of driver node. A single-input complex network is called controllable network if it can be driven from any initial state to desired state within finite time in n dimensional state space using a driver node. A driver node through which a network can be controlled is not unique. Non-uniqueness of driver node poses a challenge to select a right driver node when multiple possibilities exist. It is important to characterize these driver nodes and select the right driver node. In this paper, we consider a single-input unstable network with saturated actuator.