Lars König
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lars König has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Alexander Derksen
2 shared publications- Alexander Derksen
Fraunhofer MEVIS Lübeck Germany
2 shared publications Jan Rühaak
2 shared publications- Jan Rühaak
Fraunhofer MEVIS, Lübeck, Germany
2 shared publications A Cifor
Institute of Biomedical Engineering, University of Oxford
1 shared publicationB. Fischer
Fraunhofer MEVIS Project Group Image Registration, Lübeck, Germany
1 shared publication
Latest Publications
- Open Access
A matrix-free approach to parallel and memory-efficient deformable image registration
We present a novel computational approach to fast and memory-efficient deformable image registration. In the variational registration model, the computation of the objective function derivatives is the computationally most expensive operation, both in terms of runtime and memory requirements. In order to target this bottleneck, we analyze the matrix structure of gradient and Hessian computations for the case of the normalized gradient fields distance measure and curvature regularization. Based on this analysis, we derive equivalent matrix-free closed-form expressions for derivative computations, eliminating the need for storing intermediate results and the costs of sparse matrix arithmetic. This has further benefits: (1) matrix computations can be fully parallelized, (2) memory complexity for derivative computation is reduced from linear to constant, and (3) overall computation times are substantially reduced. In comparison with an optimized matrix-based reference implementation, the CPU implementation achieves speedup factors between 3.1 and 9.7, and we are able to handle substantially higher resolutions. Using a GPU implementation, we achieve an additional speedup factor of up to 9.2. Furthermore, we evaluated the approach on real-world medical datasets. On ten publicly available lung CT images from the DIR-Lab 4DCT dataset, we achieve the best mean landmark error of 0.93 mm compared to other submissions on the DIR-Lab website, with an average runtime of only 9.23 s. Complete non-rigid registration of full-size 3D thorax-abdomen CT volumes from oncological follow-up is achieved in 12.6 s. The experimental results show that the proposed matrix-free algorithm enables the use of variational registration models also in applications which were previously impractical due to memory or runtime restrictions.
Open AccessA matrix-free approach to parallel and memory-efficient deformable image registration
We present a novel computational approach to fast and memory-efficient deformable image registration. In the variational registration model, the computation of the objective function derivatives is the computationally most expensive operation, both in terms of runtime and memory requirements. In order to target this bottleneck, we analyze the matrix structure of gradient and Hessian computations for the case of the normalized gradient fields distance measure and curvature regularization. Based on this analysis, we derive equivalent matrix-free closed-form expressions for derivative computations, eliminating the need for storing intermediate results and the costs of sparse matrix arithmetic. This has further benefits: (1) matrix computations can be fully parallelized, (2) memory complexity for derivative computation is reduced from linear to constant, and (3) overall computation times are substantially reduced. In comparison with an optimized matrix-based reference implementation, the CPU implementation achieves speedup factors between 3.1 and 9.7, and we are able to handle substantially higher resolutions. Using a GPU implementation, we achieve an additional speedup factor of up to 9.2. Furthermore, we evaluated the approach on real-world medical datasets. On ten publicly available lung CT images from the DIR-Lab 4DCT dataset, we achieve the best mean landmark error of 0.93 mm compared to other submissions on the DIR-Lab website, with an average runtime of only 9.23 s. Complete non-rigid registration of full-size 3D thorax-abdomen CT volumes from oncological follow-up is achieved in 12.6 s. The experimental results show that the proposed matrix-free algorithm enables the use of variational registration models also in applications which were previously impractical due to memory or runtime restrictions.
- 1 January 2018
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 40 (3) , B858-B888
A Matrix-Free Approach to Parallel and Memory-Efficient Deformable Image Registration
We present a novel computational approach to fast and memory-efficient deformable image registration. In the variational registration model, the computation of the objective function derivatives is the computationally most expensive operation, both in terms of runtime and memory requirements. In order to target this bottleneck, we analyze the matrix structure of gradient and Hessian computations for the case of the normalized gradient fields distance measure and curvature regularization. Based on this analysis, we derive equivalent matrix-free closed-form expressions for derivative computations, eliminating the need for storing intermediate results and the costs of sparse matrix arithmetic. This has further benefits: (1) matrix computations can be fully parallelized, (2) memory complexity for derivative computation is reduced from linear to constant, and (3) overall computation times are substantially reduced. In comparison with an optimized matrix-based reference implementation, the CPU implementation ac...
- 1 January 2018
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Scientific Computing
- Vol. 40 (3) , B858-B888
A Matrix-Free Approach to Parallel and Memory-Efficient Deformable Image Registration
We present a novel computational approach to fast and memory-efficient deformable image registration. In the variational registration model, the computation of the objective function derivatives is the computationally most expensive operation, both in terms of runtime and memory requirements. In order to target this bottleneck, we analyze the matrix structure of gradient and Hessian computations for the case of the normalized gradient fields distance measure and curvature regularization. Based on this analysis, we derive equivalent matrix-free closed-form expressions for derivative computations, eliminating the need for storing intermediate results and the costs of sparse matrix arithmetic. This has further benefits: (1) matrix computations can be fully parallelized, (2) memory complexity for derivative computation is reduced from linear to constant, and (3) overall computation times are substantially reduced. In comparison with an optimized matrix-based reference implementation, the CPU implementation ac...
- Open Access
- 20 September 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-9
Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm. A DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones. The approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS. With accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved.
- 20 September 2016
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-9
Open AccessDeformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm. A DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones. The approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS. With accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved.
- 5 April 2016
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 13 (1) , 205-225
A matrix-free approach to efficient affine-linear image registration on CPU and GPU
- 5 April 2016
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 13 (1) , 205-225
A matrix-free approach to efficient affine-linear image registration on CPU and GPU
- Open Access
- 2 July 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (14) , 5571-5599
The 2014 liver ultrasound tracking benchmark
The Challenge on Liver Ultrasound Tracking (CLUST) was held in conjunction with the MICCAI 2014 conference to enable direct comparison of tracking methods for this application. This paper reports the outcome of this challenge, including setup, methods, results and experiences. The database included 54 2D and 3D sequences of the liver of healthy volunteers and tumor patients under free breathing. Participants had to provide the tracking results of 90% of the data (test set) for pre-defined point-landmarks (healthy volunteers) or for tumor segmentations (patient data). In this paper we compare the best six methods which participated in the challenge. Quantitative evaluation was performed by the organizers with respect to manual annotations. Results of all methods showed a mean tracking error ranging between 1.4 mm and 2.1 mm for 2D points, and between 2.6 mm and 4.6 mm for 3D points. Fusing all automatic results by considering the median tracking results, improved the mean error to 1.2 mm (2D) and 2.5 mm (3D). For all methods, the performance is still not comparable to human inter-rater variability, with a mean tracking error of 0.5–0.6 mm (2D) and 1.2–1.8 mm (3D). The segmentation task was fulfilled only by one participant, resulting in a Dice coefficient ranging from 76.7% to 92.3%. The CLUST database continues to be available and the online leader-board will be updated as an ongoing challenge.
- 2 July 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (14) , 5571-5599
Open AccessThe 2014 liver ultrasound tracking benchmark
The Challenge on Liver Ultrasound Tracking (CLUST) was held in conjunction with the MICCAI 2014 conference to enable direct comparison of tracking methods for this application. This paper reports the outcome of this challenge, including setup, methods, results and experiences. The database included 54 2D and 3D sequences of the liver of healthy volunteers and tumor patients under free breathing. Participants had to provide the tracking results of 90% of the data (test set) for pre-defined point-landmarks (healthy volunteers) or for tumor segmentations (patient data). In this paper we compare the best six methods which participated in the challenge. Quantitative evaluation was performed by the organizers with respect to manual annotations. Results of all methods showed a mean tracking error ranging between 1.4 mm and 2.1 mm for 2D points, and between 2.6 mm and 4.6 mm for 3D points. Fusing all automatic results by considering the median tracking results, improved the mean error to 1.2 mm (2D) and 2.5 mm (3D). For all methods, the performance is still not comparable to human inter-rater variability, with a mean tracking error of 0.5–0.6 mm (2D) and 1.2–1.8 mm (3D). The segmentation task was fulfilled only by one participant, resulting in a Dice coefficient ranging from 76.7% to 92.3%. The CLUST database continues to be available and the online leader-board will be updated as an ongoing challenge.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 734-738
Parallel and memory efficient multimodal image registration for radiotherapy using normalized gradient fields
We introduce a new highly parallel and memory efficient deformable image registration algorithm to handle challenging clinical applications. The algorithm is based on the normalized gradient fields (NGF) distance measure and Gauss-Newton numerical optimization. By carefully analyzing the mathematical structure of the problem, a matrix-free Hessian-vector multiplication for NGF is derived, giving a highly integrated formulation. Embedding the new scheme in a full, non-linear image registration algorithm enables fast calculations on high resolutions with dramatically reduced memory consumption. The new approach provides linear scalability compared with a traditional sparse-matrix-based scheme. The algorithm is evaluated on a challenging problem from radiotherapy, where pelvis cone-beam CT and planning CT images are registered. Speedups up to a factor of 149.3 for a single Hessian-vector multiplication and of 20.3 for a complete non-linear registration are achieved.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 734-738
Parallel and memory efficient multimodal image registration for radiotherapy using normalized gradient fields
We introduce a new highly parallel and memory efficient deformable image registration algorithm to handle challenging clinical applications. The algorithm is based on the normalized gradient fields (NGF) distance measure and Gauss-Newton numerical optimization. By carefully analyzing the mathematical structure of the problem, a matrix-free Hessian-vector multiplication for NGF is derived, giving a highly integrated formulation. Embedding the new scheme in a full, non-linear image registration algorithm enables fast calculations on high resolutions with dramatically reduced memory consumption. The new approach provides linear scalability compared with a traditional sparse-matrix-based scheme. The algorithm is evaluated on a challenging problem from radiotherapy, where pelvis cone-beam CT and planning CT images are registered. Speedups up to a factor of 149.3 for a single Hessian-vector multiplication and of 20.3 for a complete non-linear registration are achieved.
- 2 November 2014
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 14 (2) , 341-361
Highly efficient image registration for embedded systems using a distributed multicore DSP architecture
- 2 November 2014
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 14 (2) , 341-361
Highly efficient image registration for embedded systems using a distributed multicore DSP architecture
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 580-583
A fast and accurate parallel algorithm for non-linear image registration using Normalized Gradient fields
We present a novel parallelized formulation for fast non-linear image registration. By carefully analyzing the mathematical structure of the intensity independent Normalized Gradient Fields distance measure, we obtain a scalable, parallel algorithm that combines fast registration and high accuracy to an attractive package. Based on an initial formulation as an optimization problem, we derive a per pixel parallel formulation that drastically reduces computational overhead. The method was evaluated on ten publicly available 4DCT lung datasets, achieving an average registration error of only 0.94 mm at a runtime of about 20 s. By omitting the finest level, we obtain a speedup to 6.56 s with a moderate increase of registration error to 1.00 mm. In addition our algorithm shows excellent scalability on a multi-core system.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 580-583
A fast and accurate parallel algorithm for non-linear image registration using Normalized Gradient fields
We present a novel parallelized formulation for fast non-linear image registration. By carefully analyzing the mathematical structure of the intensity independent Normalized Gradient Fields distance measure, we obtain a scalable, parallel algorithm that combines fast registration and high accuracy to an attractive package. Based on an initial formulation as an optimization problem, we derive a per pixel parallel formulation that drastically reduces computational overhead. The method was evaluated on ten publicly available 4DCT lung datasets, achieving an average registration error of only 0.94 mm at a runtime of about 20 s. By omitting the finest level, we obtain a speedup to 6.56 s with a moderate increase of registration error to 1.00 mm. In addition our algorithm shows excellent scalability on a multi-core system.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 572-575
A fully parallel algorithm for multimodal image registration using normalized gradient fields
We present a super fast variational algorithm for the challenging problem of multimodal image registration. It is capable of registering full-body CT and PET images in about a second on a standard CPU with virtually no memory requirements. The algorithm is founded on a Gauss-Newton optimization scheme with specifically tailored, mathematically optimized computations for objective function and derivatives. It is fully parallelized and perfectly scalable, thus directly suitable for usage in many-core environments. The accuracy of our method was tested on 21 PET-CT scan pairs from clinical routine. The method was able to correct random distortions in the range from -10 cm to 10 cm translation and from -15° to 15° degree rotation to subvoxel accuracy. In addition, it exhibits excellent robustness to noise.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 572-575
A fully parallel algorithm for multimodal image registration using normalized gradient fields
We present a super fast variational algorithm for the challenging problem of multimodal image registration. It is capable of registering full-body CT and PET images in about a second on a standard CPU with virtually no memory requirements. The algorithm is founded on a Gauss-Newton optimization scheme with specifically tailored, mathematically optimized computations for objective function and derivatives. It is fully parallelized and perfectly scalable, thus directly suitable for usage in many-core environments. The accuracy of our method was tested on 21 PET-CT scan pairs from clinical routine. The method was able to correct random distortions in the range from -10 cm to 10 cm translation and from -15° to 15° degree rotation to subvoxel accuracy. In addition, it exhibits excellent robustness to noise.