AGAbhijit Achyut Gurjarpadhye

Abhijit Achyut Gurjarpadhye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abhijit Achyut Gurjarpadhye has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dynamic Assessment of the Endothelialization of Tissue-Engineered Blood Vessels Using an Optical Coherence Tomography Catheter-Based Fluorescence Imaging System

    by Abhijit Achyut Gurjarpadhye, Matthew R. DeWitt, Yong Xu, Ge Wang, Marissa Nichole Rylander, Christopher G. Rylander

    Lumen endothelialization of bioengineered vascular scaffolds is essential to maintain small-diameter graft patency and prevent thrombosis postimplantation. Unfortunately, nondestructive imaging methods to visualize this dynamic process are lacking, thus slowing development and clinical translation of these potential tissue-engineering approaches. To meet this need, a fluorescence imaging system utilizing a commercial optical coherence tomography (OCT) catheter was designed to visualize graft endothelialization. C7 DragonFly™ intravascular OCT catheter was used as a channel for delivery and collection of excitation and emission spectra. Poly-dl-lactide (PDLLA) electrospun scaffolds were seeded with endothelial cells (ECs). Seeded cells were exposed to Calcein AM before imaging, causing the living cells to emit green fluorescence in response to blue laser. By positioning the catheter tip precisely over a specimen using high-fidelity electromechanical components, small regions of the specimen were excited selectively. The resulting fluorescence intensities were mapped on a two-dimensional digital grid to generate spatial distribution of fluorophores at single-cell-level resolution. Fluorescence imaging of endothelialization on glass and PDLLA scaffolds was performed using the OCT catheter-based imaging system as well as with a commercial fluorescence microscope. Cell coverage area was calculated for both image sets for quantitative comparison of imaging techniques. Tubular PDLLA scaffolds were maintained in a bioreactor on seeding with ECs, and endothelialization was monitored over 5 days using the OCT catheter-based imaging system. No significant difference was observed in images obtained using our imaging system to those acquired with the fluorescence microscope. Cell area coverage calculated using the images yielded similar values. Nondestructive imaging of endothelialization on tubular scaffolds showed cell proliferation with cell coverage area increasing from 15 ± 4% to 89 ± 6% over 5 days. In this study, we showed the capability of an OCT catheter-based imaging system to obtain single-cell resolution and to quantify endothelialization in tubular electrospun scaffolds. We also compared the resulting images with traditional microscopy, showing high fidelity in image capability. This imaging system, used in conjunction with OCT, could potentially be a powerful tool for in vitro optimization of scaffold cellularization, ensuring long-term graft patency postimplantation.


  • Imaging and characterization of bioengineered blood vessels within a bioreactor using free-space and catheter-based OCT

    by Abhijit A. Gurjarpadhye, Bryce M. Whited, Alana Sampson, Guoguang Niu, Kriti Sen Sharma, William C. Vogt, Ge Wang, Yong Xu, Shay Soker, Marissa Nichole Rylander, et al.

    Regenerative medicine involves the bioengineering of a functional tissue or organ by seeding living cells on a biodegradable scaffold cultured in a bioreactor. A major barrier to creating functional tissues, however, has been the inability to monitor the dynamic and complex process of scaffold maturation in real time, making control and optimization extremely difficult. Current methods to assess maturation of bioengineered constructs, such as histology or organ bath physiology, are sample-destructive. Optical coherence tomography (OCT) has recently emerged as a key modality for structural assessment of native blood vessels as well as engineered vessel mimics. The objective of this study was to monitor and assess in real time the development of a bioengineered blood vessel using a novel approach of combining both free-space and catheter-based OCT imaging in a new quartz-walled bioreactor. Development of the blood vessel was characterized by changes in thickness and scattering coefficient over a 30-day period. We constructed a novel blood vessel bioreactor utilizing a rotating cylindrical quartz cuvette permitting free-space OCT imaging of an installed vessel's outer surface. A vascular endoscopic OCT catheter was used to image the lumen of the vessels. The quartz cuvette permits 360 degree, free-space OCT imaging of the blood vessel. Bioengineered blood vessels were fabricated using biodegradable polymers (15% PCL/collagen, ∼300 µm thick) and seeded with CH3 10t1/2 mesenchymal stem cells. A swept-source OCT imaging system comprised of a 20 kHz tunable laser (Santec HSL2000) with 1,300 nm central wavelength and 110 nm FWHM bandwidth was used to assess the vessels. OCT images were obtained at days 1, 4, 7, 14, 21, and 30. Free-space (exterior surface) OCT images were co-registered with endoscopic OCT images to determine the vessel wall thickness. DAPI-stained histological sections, acquired at same time point, were evaluated to quantify wall thickness and cellular infiltration. Non-linear curve fitting of free-space OCT data to the extended Huygen-Fresnel model was performed to determine optical scattering properties. Vessel wall thickness increased from 435 ± 15 µm to 610 ± 27 µm and Vessel scattering coefficient increased from 3.73 ± 0.32 cm⁻¹ to 5.74 ± 0.06 cm⁻¹ over 30 days. Histological studies showed cell migration from the scaffold surface toward the lumen and cell proliferation over the same time course. The imaging procedure did not have any significant impact on scaffold dimensions, cell migration, or cell proliferation. This study suggests that combination of free-space and catheter-based OCT for blood vessel imaging provides accurate structural information of the developing blood vessel. We determined that free-space OCT images could be co-registered with catheter-based OCT images to monitor structural features such as wall thickness or delamination of the developing tissue-engineered blood vessel within a bioreactor. Structural parameters and optical properties obtained from OCT imaging correlate with histological sections of the blood vessel and could potentially be used as markers to non-invasively and non-destructively assess regeneration of engineered tissues in real time.


  • Optical properties of breast tumor phantoms containing carbon nanotubes and nanohorns

    by Saugata Sarkar, Abhijit A. Gurjarpadhye, Christopher G. Rylander, Marissa Nichole Rylander

    The degree by which optical properties of tumors are altered following introduction of carbon nanotubes (CNTs) of varying concentration and type is poorly understood, making it difficult to predict the impact of CNT inclusion on the photothermal response to laser therapies. Optical properties were measured of phantoms representative of breast tumor tissue incorporated with multiwalled carbon nanotubes (MWNTs), single-walled carbon nanotubes (SWNTs), and single-walled carbon nanohorns (SWNHs) of varying concentration (0.01–0.1 mg/ml). Tissue phantoms were made from sodium alginate (3 g/ml) incorporated with polystyrene microbeads (3 μm diam and 1 mg/ml) and talc-France powder (40 mg/ml). Absorption (μa) and reduced scattering (


  • Open Access

    Effect of Localized Mechanical Indentation on Skin Water Content Evaluated Using OCT

    by Abhijit A. Gurjarpadhye, William C. Vogt, Yajing Liu, Christopher G. Rylander

    The highly disordered refractive index distribution in skin causes multiple scattering of incident light and limits optical imaging and therapeutic depth. We hypothesize that localized mechanical compression reduces scattering by expulsing unbound water from the dermal collagen matrix, increasing protein concentration and decreasing the number of index mismatch interfaces between tissue constituents. A swept-source optical coherence tomography (OCT) system was used to assess changes in thickness and group refractive index inex vivoporcine skin, as well as changes in signal intensity profile when imagingin vivohuman skin. Compression ofex vivoporcine skin resulted in an effective strain of −58.5%, an increase in refractive index from 1.39 to 1.50, and a decrease in water volume fraction from 0.66 to 0.20.In vivoOCT signal intensity increased by 1.5 dB at a depth of 1 mm, possibly due to transport of water away from the compressed regions. These finding suggest that local compression could be used to enhance light-based diagnostic and therapeutic techniques.


  • Connexin43 Carboxyl-Terminal Peptides Reduce Scar Progenitor and Promote Regenerative Healing Following Skin Wounding

    by Gautam S Ghatnekar, Michael P O‘qUinn, L Jane Jourdan, Abhijit A Gurjarpadhye, Robert L Draughn, Robert G Gourdie

    Aim: Gap-junctional connexin43 (Cx43) has roles in multiple aspects of skin wound healing – including scarring. The aim here was to study the effects of a cell-permeant peptide from the Cx43 carboxyl-terminus (CT) on scarring and regeneration following cutaneous injury. Materials & methods: The effects of Cx43 CT peptide were studied in mouse and pig models of cutaneous injury. The parameters assessed included neutrophil density, wound closure, granulation, regeneration and skin tensile properties. Results: Cx43 CT-peptide prompted decreases in area of scar progenitor tissue and promoted restoration of dermal histoarchitecture and mechanical strength following wounding of skin. These changes in healing were preceded by peptide-induced reduction in inflammatory neutrophil infiltration and alterations in the organization of epidermal Cx43, including increased connexon aggregation. Conclusion: Cx43 CT peptide promotes regenerative healing of cutaneous wounds and may have applications in tissues other than sk...


  • Cardiac neural crest ablation inhibits compaction and electrical function of conduction system bundles

    by Abhijit Gurjarpadhye, Kenneth W. Hewett, Charles Justus, Xuejun Wen, Harriett Stadt, Margaret L. Kirby, David Sedmera, Robert G. Gourdie

    Retroviral and transgenic lineage-tracing studies have shown that neural crest cells associate with the developing bundles of the ventricular conduction system. Whereas this migration of cells does not provide progenitors for the myocardial cells of the conduction system, the question of whether neural crest affects the differentiation and/or function of cardiac specialized tissues continues to be of interest. Using optical mapping of voltage-sensitive dye, we determined that ventricles from chick embryos in which the cardiac neural crest had been laser ablated did not progress to apex-to-base activation by the expected stage [i.e., Hamburger and Hamilton (HH) 35] but instead maintained basal breakthroughs of epicardial activation consistent with immature function of the conduction system. In direct studies of activation, waves of depolarization originating from the His bundle were found to be uncommon in control hearts from HH34 and HH35 embryos. However, activations propagating from septal base, at or near the His bundle, occurred frequently in hearts from HH34 and HH35 neural crest-ablated embryos. Consistent with His bundle cells maintaining electrical connections with adjacent working myocytes, histological analyses of hearts from neural crest-ablated embryos revealed His bundles that had not differentiated a lamellar organization or undergone a process of compaction and separation from surrounding myocardium observed in controls. Furthermore, measurements on histological sections from optically mapped hearts indicated that, whereas His bundle diameter in control embryos thinned by almost one-half between HH30 and HH34, the His bundle in ablated embryos underwent no such compaction in diameter, maintaining a thickness at HH30, HH32, and HH34 similar to that observed in HH30 controls. We conclude that the cardiac neural crest is required in a novel function involving lamellar compaction and electrical isolation of the basally located His bundle from surrounding myocardium.


  • Does Neural Crest Ablation Delay or Inhibit Maturation of the Conduction System of the Chick Embryonic Heart?

    by Kenneth. W Hewett, Charles Justus, Abhijit Gurjarpadhye, David Sedmera, Harriett A. Stadt, Margaret L. Kirby, Robert G. Gourdie

    Extended abstract of a paper presented at Microscopy and Microanalysis 2004 in Savannah, Georgia, USA, August 1–5, 2004.