Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weiwei Yue has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reliable bearing diagnosis from vibration measurements across operating conditions using reliability-guided adaptation

    by Shilei Sun, Rui Li, Xincheng Li, Shunye Qu, Guanglu Lu, Ruoming Lan, Shaohua Qin, Keliang Liao, Weiwei Yue

    Vibration measurements from rotating machinery vary with rotational speed, load torque, radial load, and transmission path. Consequently, a model calibrated under one measurement condition may produce confident but incorrect predictions under another. This study investigates cross-condition bearing diagnosis from the perspective of measurement reliability. Unlabeled target-condition measurements vary in their reliability as adaptation evidence: some retain stable fault-related evidence, whereas others become ambiguous because operating-condition changes alter the measured waveform and time-frequency response. To address this issue, a reliability-guided adaptation (RGA) method is proposed. It estimates measurement reliability from prediction confidence and agreement among complementary signal views, and uses this score to regulate conditional distribution alignment, cross-view consistency transfer, and class-center regularization. Target measurements with unstable or conflicting evidence therefore contribute less to the adaptation objectives, limiting their influence under shifted operating conditions. The method is evaluated on public bearing vibration datasets covering speed, load-torque, radial-load, and coupled condition changes, and is further validated using independently acquired laboratory measurements from an in-house cross-speed bearing test rig. The results show that severe operating-condition changes substantially alter the measurement distribution, while RGA achieves high class separability across the examined transfers. These findings suggest that treating target measurements as reliability-weighted signal evidence, rather than uniformly reliable samples, is an effective route to robust vibration-based bearing diagnosis under variable measurement conditions.

  • Open Access

    A Multichannel Solid-State Potentiometric Sensor Array for Heavy Metal Ions

    by Zongfeng Wei, Guanliang Li, Zhuqing Wang, Shicai Xu, Enguang Lv, Weiwei Yue

    Heavy metal ions are common environmental contaminants that threaten aquatic ecosystems and human health. However, conventional analytical techniques often require expensive instrumentation and complex sample pretreatment. This work presents a peptide-based multichannel solid-state potentiometric microelectrode array for simultaneous detection of Cu2+, Cd2+, and Pb2+. The array consists of one shared Ag/AgCl reference electrode and three groups of gold indicator microelectrodes (10 μm in diameter), with each group containing three parallel electrodes for replicate measurements. Each group is functionalized with a distinct peptide receptor specific to one target metal ion. The proposed array exhibits near-Nernstian responses and good selectivity against common interfering ions. Practical applicability is demonstrated by analyzing spiked lake water samples under a fixed chloride condition, with recoveries ranging from 94% to 105%. This work provides a miniaturized, reproducible, and versatile platform for simultaneous potentiometric detection of multiple heavy metal ions, and the peptide-based recognition strategy can be extended to other targets by simply replacing the peptide sequences.

  • Erratum to “An Ultralow-Energy Voltage Level Shifter With an Output-Cycle-Based Dynamic Biasing Scheme in a 130-nm CMOS Technology”

    by Qun Zhou, Kang Zeng, Weiwei Yue, Qing Hua

    This addresses errors in the Early Access version of [1]. Due to a publisher error, the terms Q1, Q2, and Q3 were used (with subscripts) instead of Q1, Q2, and Q3 (no subscript). They represent nodes on the schematic, not variables.

  • An Ultralow-Energy Voltage Level Shifter With an Output-Cycle-Based Dynamic Biasing Scheme in a 130-nm CMOS Technology

    by Qun Zhou, Kang Zeng, Weiwei Yue, Qing Hua

    This brief presents an ultralow-energy and low-propagation-delay balanced voltage level shifter (VLS) with a wide voltage conversion range. The proposed VLS achieves low propagation delay while operating with subthreshold voltage, utilizing a newly introduced dynamic biasing scheme (DBS). This scheme improves both turn-on and turn-off speeds by reducing the threshold voltage of the input device circularly. The biasing-related power consumption is largely reduced by well-designed structure. The function of the proposed VLS design has been validated by using a standard 130-nm CMOS technology, taking into account process, voltage, and temperature (PVT) variations. With the implementation of the DBS, the delay is reduced to 6.5 ns, dynamic energy is lowered to 21.7 fJ, the minimum supply voltage is 0.18 V, and the average static power consumption is 2.8 nW for a conversion from 0.3 to 1.2 V.


  • Open Access

    Magnetically controlled graphene field-effect transistor biosensor for highly sensitive detection of cardiac troponin I

    by Xiaofeng Zhu, Kangning Cheng, Yue Ding, Huanqing Liu, Shuqi Xie, Yuwei Cao, Weiwei Yue

    Herein, we have constructed a magnetic graphene field-effect transistor biosensor (MGFETs) for highly sensitive detection of cardiac troponin I (CTNI). Graphene films transferred to ITO conductive glass as conductive channels. CTNI aptamer was immobilized onto the graphene film via 1-pyrene-butanoic acid succinimidyl ester (PBASE) to capture CTNI. Magnetic nanobeads (MBs) modified with CTNI antibody were added to the reaction chamber to form an aptamer/CTNI/antibody/magnetic nanobeads sandwich-type complex. We found that the magnetic force exerted on the complex leads to an impedance change of the graphene film. The reason for this result is that the magnetic field exerts an influence on the MBs, causing CTNI aptamer strand to bend, resulting in a change in the distance between the double conductive layers of the graphene film surface and the test solution. With periodic sampling integration, different concentrations of CTNI can be detected with high sensitivity. Due to the stringent recognition capability and high affinity between the CTNI aptamer and CTNI, MGFETs have the potential to detect various types of proteins. Furthermore, MGFETs also have the potential to be utilized for the detection of DNA or specific cells in the future.


  • Open Access

    Magnetically controlled graphene field-effect transistor biosensor for highly sensitive detection of cardiac troponin I

    by Xiaofeng Zhu, Kangning Cheng, Yue Ding, Huanqing Liu, Shuqi Xie, Yuwei Cao, Weiwei Yue

    Herein, we have constructed a magnetic graphene field-effect transistor biosensor for highly sensitive detection of cardiac troponin I (CTNI). Graphene film was used as a conductive channel and transferred onto a glass substrate with two indium tin oxide (ITO) electrodes. CTNI aptamer was immobilized onto the graphene film via 1-pyrene-butanoic acid succinimidyl ester (PBASE) to capture CTNI. Magnetic nanobeads modified with CTNI antibody were added to the reaction chamber to form an aptamer/CTNI/antibody/magnetic nanobeads sandwich-type complex. By applying a periodic magnetic field, we found that the magnetic force exerted on the complex leads to an impedance change of the graphene film. The results were rationalized using a model wherein the magnetic force causes the CTNI aptamer strand to bend, thereby resulting in magnetic nanobeads/CTNI aptamer modulation of the double conductive layer of graphene transistors. With periodic sampling integration, different concentrations of CTNI can be detected with high sensitivity. Due to the specific binding property of the aptamer to the antigen, the magnetic graphene field-effect transistor biosensor can be used for the specific detection of different kinds of proteins and can potentially be a detection tool for DNA, specific cells, etc.

  • Automated and rapid chemiluminescence immunoassay for cardiac troponin I based on digital microfluidics

    by Kangning Cheng, Yue Ding, Cong Liu, Yanjing Ding, Shuqi Xie, Xiaofeng Zhu, Huanqing Liu, Weiwei Yue


  • Overcoming Debye length limitations: Three-dimensional wrinkled graphene field-effect transistor for ultra-sensitive adenosine triphosphate detection

    by Yue Ding, Chonghui Li, Meng Tian, Jihua Wang, Zhenxing Wang, Xiaohui Lin, Guofeng Liu, Wanling Cui, Xuefan Qi, Siyu Li, et al.

    Adenosine triphosphate (ATP) is closely related to the pathogenesis of certain diseases, so the detection of trace ATP is of great significance to disease diagnosis and drug development. Graphene field-effect transistors (GFETs) have been proven to be a promising platform for the rapid and accurate detection of small molecules, while the Debye shielding limits the sensitive detection in real samples. Here, a three-dimensional wrinkled graphene field-effect transistor (3D WG-FET) biosensor for ultra-sensitive detection of ATP is demonstrated. The lowest detection limit of 3D WG-FET for analyzing ATP is down to 3.01 aM, which is much lower than the reported results. In addition, the 3D WG-FET biosensor shows a good linear electrical response to ATP concentrations in a broad range of detection from 10 aM to 10 pM. Meanwhile, we achieved ultra-sensitive (LOD: 10 aM) and quantitative (range from 10 aM to 100 fM) measurements of ATP in human serum. The 3D WG-FET also exhibits high specificity. This work may provide a novel approach to improve the sensitivity for the detection of ATP in complex biological matrix, showing a broad application value for early clinical diagnosis and food health monitoring.


  • Open Access

    LSP-SPP Coupling Structure Based on Three-Dimensional Patterned Sapphire Substrate for Surface Enhanced Raman Scattering Sensing

    by Shuqi Xie, Haipeng Si, Cong Liu, Weihao Liu, Muhammad Shafi, Shouzhen Jiang, Weiwei Yue

    Although the fabrication of controllable three-dimensional (3D) microstructures on substrates has been proposed as an effective solution for SERS, there remains a gap in the detection and manufacturability of 3D substrates with high performance. In this study, photolithography is adopted to obtain a pyramid-like array on a patterned sapphire substrate (PSS), with Al2O3 as the dielectric layer. In addition, silver nanoparticles (AgNPs) are used to decorate Au films to obtain mass-producible 3D SRES substrates. In the case of low fluorescence, the substrate realizes the coupling of localized surface plasmon polaritons (LSPs) and surface plasmon polaritons (SPPs), which is consistent with the simulation results obtained using the finite element method. The performance of the SERS substrate is evaluated using rhodamine 6G (R6G) and toluidine blue (TB) as probe molecules with detection limits of 10−11 M and 10−9 M, respectively. The substrate exhibits high hydrophobicity and excellent light-capturing capability. Moreover, it shows self-cleaning ability and long-term stability in practical applications. Allowing for the consistency of the composite substrate in the preparation process and the high reproducibility of the test results, it is considered to be promising for mass production.


  • An array structures of nanoparticle-coupled hyperbolic metamaterials for efficient SERS sensing

    by Cong Liu, Lingyun Li, Xuejian Du, Jinjuan Gao, Jingwen Feng, Muhammad Shafi, Shouzhen Jiang, Weiwei Yue