MEMichele L. Esposito

Michele L. Esposito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michele L. Esposito has a total of 151 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Imaging‐derived coronary fractional flow reserve: advances in physics‐based, machine learning, and physics‐informed methods

    by Tanxin Zhu, Emran Hossen, Chen Zhao, Jingfeng Jiang, Michele Esposito, Jiguang Sun, Weihua Zhou

    Objective . To provide a translation-oriented review of imaging-derived coronary fractional flow reserve (FFR) methods for functional assessment of coronary artery stenosis, with emphasis on computed tomography coronary angiography- and invasive coronary angiography-based workflows. Approach . We synthesize recent developments in physics-based computational fluid dynamics (CFD), reduced-order modeling, machine learning/deep learning (ML/DL), and physics-informed learning, including physics-informed neural networks (PINNs) and neural operators. The review is organized around clinical workflow requirements, computational feasibility, image-quality constraints, boundary-condition uncertainty, model validation, and deployment-oriented evaluation. Main results . Physics-based FFR methods provide mechanistic interpretability and spatially resolved hemodynamics, but remain sensitive to coronary geometry, physiological assumptions, and computational burden. ML/DL approaches markedly accelerate FFR estimation, but their reliability depends on representative data, calibration, and robustness to domain shift. Among emerging approaches, physics-informed learning currently offers a favorable methodological balance of computational speed, physical consistency, data efficiency, and spatially resolved output. Complementary coronary studies support this assessment: graph-based physics-informed learning has shown strong agreement with measured FFR across x-ray and CT data; a physics-informed operator preserved near-CFD/PINN diagnostic performance while reducing inference from hundreds of seconds to less than one second; and physics-informed pretraining improved a downstream clinical prediction task while producing pressure and FFR curves. The latter finding supports transferable physiological representation learning rather than direct validation of FFR accuracy against invasive pressure-wire measurements. Overall, these results support physics-informed methods as a promising next-generation research direction, although prospective multicenter validation remains necessary. Significance . Imaging-derived FFR is moving toward faster, more automated, and more physiologically constrained decision support. Among emerging computational paradigms, physics-informed models are particularly promising because they can retain the speed of learned inference while constraining predictions with governing equations and boundary conditions. Current comparative evidence supports prioritizing these methods for prospective clinical validation, with their apparent advantages tested against established CFD, data-driven ML, and invasive physiological references.

  • Open Access

    Plantar Thermography for Longitudinal Remote Monitoring of Chronic Heart Failure

    by Michele L. Esposito, Lefan Xuan, Elizabeth Zemp, Michael R. Zile, Ryan J. Tedford, David R. Linders, Kurt W. Prins

    Rural patients with heart failure (HF) have poor access to care, worse outcomes, and may benefit from at-home monitoring. We evaluated whether foot temperature measured using a thermographic floor mat was associated with invasively measured cardiac output and whether longitudinal temperature changes preceded HF events. We conducted a two-part prospective, observational single-center study using the SmartMat (Podimetrics, Somerville, MA), which acquires plantar thermograms and ambient temperature. In the acute study, patients undergoing clinically indicated right heart catheterization completed 4 scans on the same day. In the chronic study, patients with a HF hospitalization in the past year and New York Heart Association Class II-III symptoms were instructed to use the device and a scale daily for 6 months. A HF event was defined as receiving at least one dose of intravenous or subcutaneous diuretic. Thirty patients were enrolled in the acute study. Mean right hallux temperature positively correlated with thermodilution cardiac output (r=0.63, p<0.001). 42 patients were enrolled in the chronic study. Among patients experiencing an HF event, ambient-adjusted hallux temperature declined in the 15 days immediately preceding the event compared with days 15– 30 before the event. Plantar thermograms are associated with invasively measured cardiac output and may detect subclinical worsening before HF events. Foot temperature may provide complementary information regarding HF decompensation, supporting further evaluation of plantar thermography for remote HF monitoring.

  • Open Access

    Building Interventional Heart Failure: The Path to a Recognized Discipline

    by Ahmed A. Zayed, Elie Bou Sanayeh, P. Elliott Miller, Saraschandra Vallabhajosyula, Mir Babar Basir, Carlos D. Davila, Marwan Jumean, Miguel Alvarez Villela, Amirali Masoumi, Mohit Pahuja, et al.

  • Uncertainty-Guided Conservative Propagation for Coronary Artery Segmentation

    by Huan Huang, Zhihui Xu, Michele Esposito, Chen Zhao

  • Open Access

    Computed Fluid Dynamics-Based Blood Pressure Prediction for Coronary Artery Disease Diagnosis Using Coronary Computed Tomography Angiography

    by Rene Lisasi, Huan Huang, William Pei, Michele Esposito, Chen Zhao

    Computational fluid dynamics (CFD)-based simulation of coronary blood flow provides valuable hemodynamic markers, such as pressure gradients, for diagnosing coronary artery disease (CAD). However, CFD is computationally expensive, time-consuming, and difficult to integrate into large-scale clinical workflows. These limitations restrict the availability of labeled hemodynamic data for training AI models and hinder the broad adoption of non-invasive, physiology-based CAD assessment. To address these challenges, we develop an end-to-end pipeline that automates coronary geometry extraction from coronary computed tomography angiography (CCTA), streamlines simulation data generation, and enables efficient learning of coronary blood pressure distributions. The pipeline reduces the manual burden associated with traditional CFD workflows while producing consistent training data. Furthermore, we introduce a diffusion-based regression model. Specifically, the inverted conditional diffusion (ICD) model is designed to predict coronary blood pressure directly from CCTA-derived features, thereby bypassing the need for computationally intensive CFD during inference. The proposed model is trained and validated on two CCTA datasets using the Adam optimizer with a weight decay of 1×10−3, a learning rate of 1×10−5, a batch size of 100, and Huber loss. It is then evaluated on a test set of ten simulated coronary hemodynamic cases. Experimental results demonstrate state-of-the-art performance. Compared with Long Short-Term Memory (LSTM), the proposed model improves the R2 score by 19.78%, reduces the root mean squared error (RMSE) by 19.44%, and lowers the normalized root mean squared error (NRMSE) by 18%. Compared with a multilayer perceptron (MLP), it improves the R2 score by 8.38%, reduces RMSE by 4.3%, and reduces NRMSE by 5.4%. This work represents a first step toward a scalable and accessible framework for rapid, non-invasive, CFD-based blood pressure prediction, with the potential to support CAD diagnosis.

  • Device-Related Adverse Events and Outcomes in Patients With Temporary Mechanical Circulatory Support Placed at Referral Centers Versus Cardiogenic Shock Hub Centers: An Observational Analysis

    by Zachary A. Patel, Meg K. Ospina, Roxanne Mittelstaedt, Jacob Peller, Stephanie Samani, Charlotte Marchell, Kelly Ohlrich, Brady Gunn, Michael Varrone, Kaylen Dodson, et al.

    BACKGROUND: Temporary mechanical support (tMCS) devices are often placed for cardiogenic shock (CS) at regional referral centers (RRCs) before transfer to CS hub centers (HCs). We sought to assess for differences in device-related adverse events (DRAEs) and outcomes between patients with tMCS placement for CS at an RRC before transfer to an HC compared with initial tMCS device placement at an HC. METHODS: All patients with tMCS for CS from August 2021 to August 2024 at a single center were stratified by location of initial tMCS device placement. Baseline characteristics, adjudicated DRAEs, mortality, and unfavorable outcomes (death before discharge, heart transplant, or durable left ventricular assist device) were compared. DRAE rates were calculated as events/patient-week on tMCS. Multivariable logistic regression was performed to account for baseline differences. Kaplan-Meier and Cox regression were performed to compare mortality. RESULTS: A total of 398 patients (77% HC-implanted, 23% RRC-implanted) were identified. RRC-implanted patients more commonly experienced cardiac arrest and had more advanced CS. DRAE prevalence was higher in RRC-implanted patients (any DRAE in 64% versus 33%), including bleeding (29% versus 12%), hemolysis (30% versus 18%), and vascular injury (22% versus 5%); P P P P =0.07; unfavorable outcome odds ratio, 1.60 [95% CI, 0.87–2.92]; P =0.13). CONCLUSIONS: Initial tMCS placement for CS at an RRC with transfer to an HC is associated with a higher DRAE prevalence and worse outcomes than initial tMCS placement at a CS HC. The higher mortality in RRC-implanted patients may be due to greater CS severity.


  • Author’s response to Moeller et al.

    by Anthony P. Carnicelli, Shashank S. Sinha, Song Li, Borui Li, Michele Esposito, Rachna Kataria, Arthur R. Garan, Van-Khue Ton, Kevin John, Elric Zweck, et al.