Jiangyi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiangyi Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mingoo Seok
Columbia University
6 shared publications - Peter R. Kinget
Department of Electrical Engineering, Columbia University, New York, NY, USA
3 shared publications - Teng Yang
Department of Electrical Engineering, Columbia University, New York, NY, USA
3 shared publications Ioannis Kymissis
Department of Electrical Engineering, Columbia University, New York, NY, USA
2 shared publicationsJae-Sun Seo
Department of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
2 shared publications- Doyun Kim
Samsung Advanced Institute of Technology, Suwon, Gyeongi-do, Republic of Korea
1 shared publication
Latest Publications
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (11) , 2241-2253
$In~Situ$ and In-Field Technique for Monitoring and Decelerating NBTI in 6T-SRAM Register FilesThis paper presents a technique to monitor and decelerate transistor threshold voltage ( $V_{\text {TH}}$ ) degradation caused by negative bias temperature instability (NBTI) in SRAM-based register files (RFs). The monitoring technique is in situ as it can directly sense the $V_{\text {TH}}$ of pMOSs in a bitcell. It is also in-field (i.e., postchip deployment) since the sensor output is robust to temperature and supply-voltage variations. The monitoring technique is complemented with a software framework that can create recovery vectors ( $\text {RV}_{\text {SRV}}$ ) based on the measured $V_{\text {TH}}$ degradation, which we can decelerate NBTI degradation by storing them opportunistically in an RF when the system is at stand-by mode. Test chips for a 1-kb RF with the proposed technique are prototyped in a 65-nm process. The average errors to monitor a considerable amount of NBTI degradation (>30-mV $V_{\text {TH}}$ degrading) against temperature (20 °C–80 °C) and supply-voltage (0.5–1 V) variations are 19% and 22%, respectively. These errors are $4.4\times $ and $3.4\times $ smaller than the previous in situ techniques. In addition, the experiments across multiple chips show that the generated $\text {RV}_{\text {SRV}}$ can recover a good portion of NBTI degradation and thus decelerate the degradation of data retention voltage. The area overhead of the proposed technique is 27% for the 1-kb RF and estimated to be 21% for a 4-kb RF.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (11) , 2241-2253
$In~Situ$ and In-Field Technique for Monitoring and Decelerating NBTI in 6T-SRAM Register FilesThis paper presents a technique to monitor and decelerate transistor threshold voltage ( $V_{\text {TH}}$ ) degradation caused by negative bias temperature instability (NBTI) in SRAM-based register files (RFs). The monitoring technique is in situ as it can directly sense the $V_{\text {TH}}$ of pMOSs in a bitcell. It is also in-field (i.e., postchip deployment) since the sensor output is robust to temperature and supply-voltage variations. The monitoring technique is complemented with a software framework that can create recovery vectors ( $\text {RV}_{\text {SRV}}$ ) based on the measured $V_{\text {TH}}$ degradation, which we can decelerate NBTI degradation by storing them opportunistically in an RF when the system is at stand-by mode. Test chips for a 1-kb RF with the proposed technique are prototyped in a 65-nm process. The average errors to monitor a considerable amount of NBTI degradation (>30-mV $V_{\text {TH}}$ degrading) against temperature (20 °C–80 °C) and supply-voltage (0.5–1 V) variations are 19% and 22%, respectively. These errors are $4.4\times $ and $3.4\times $ smaller than the previous in situ techniques. In addition, the experiments across multiple chips show that the generated $\text {RV}_{\text {SRV}}$ can recover a good portion of NBTI degradation and thus decelerate the degradation of data retention voltage. The area overhead of the proposed technique is 27% for the 1-kb RF and estimated to be 21% for a 4-kb RF.
- Open Access
- 31 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (3) , 728-737
An Area-Efficient Microprocessor-Based SoC With an Instruction-Cache Transformable to an Ambient Temperature Sensor and a Physically Unclonable Function
This paper presents a novel microprocessor-based system-on-chip (SoC) with the capability to transform SRAM in the instruction cache to an ambient temperature sensor and a physically unclonable function (PUF). For the transformation, we extend the original microprocessor without interlocked pipeline stages instruction set architecture and update SRAM peripheral circuits and pipeline control. All the changes are made minimally to reduce hardware overhead and the impact on the original microarchitecture. Compared to the conventional approach implementing dedicated hardware for low duty-cycle sensing and PUF, the proposed transformation approach saves ~9.8x silicon area while achieving the performance and robustness comparable to the state of the art in implementing those functions. The efficiency of the approach is verified with an SoC prototyped in a 65-nm CMOS.
- 31 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (3) , 728-737
Open AccessAn Area-Efficient Microprocessor-Based SoC With an Instruction-Cache Transformable to an Ambient Temperature Sensor and a Physically Unclonable Function
This paper presents a novel microprocessor-based system-on-chip (SoC) with the capability to transform SRAM in the instruction cache to an ambient temperature sensor and a physically unclonable function (PUF). For the transformation, we extend the original microprocessor without interlocked pipeline stages instruction set architecture and update SRAM peripheral circuits and pipeline control. All the changes are made minimally to reduce hardware overhead and the impact on the original microarchitecture. Compared to the conventional approach implementing dedicated hardware for low duty-cycle sensing and PUF, the proposed transformation approach saves ~9.8x silicon area while achieving the performance and robustness comparable to the state of the art in implementing those functions. The efficiency of the approach is verified with an SoC prototyped in a 65-nm CMOS.
- Open Access
- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 52 (10) , 2550-2562
Triple-Mode, Hybrid-Storage, Energy Harvesting Power Management Unit: Achieving High Efficiency Against Harvesting and Load Power Variabilities
This paper presents a triple-mode, hybrid storage, energy-harvesting power management unit (EH PMU) that interfaces a photovoltaic cell, a regulated load, and a rechargeable battery. The objective is to maximize the end-to-end conversion efficiency of the EH PMU against temporal mismatch and variabilities of harvesting and load power. To minimize the involvement (charging or discharging) of a battery in the voltage conversion process, the proposed hybrid energy storage employs both battery and capacitor, which increases transient energy buffering capability and reduces the overall power conversion loss. Measurement results with 65-nm test chips show that the proposed EH PMU can achieve up to 2.2$\times $ higher end-to-end conversion efficiency than the conventional dual-mode architectures under testing cases emulating realistic load and harvesting power variabilities. We also devised a framework for the system design to guide capacitor sizing, buffering voltage range selection, and end-to-end efficiency tradeoffs.- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 52 (10) , 2550-2562
Open AccessTriple-Mode, Hybrid-Storage, Energy Harvesting Power Management Unit: Achieving High Efficiency Against Harvesting and Load Power Variabilities
This paper presents a triple-mode, hybrid storage, energy-harvesting power management unit (EH PMU) that interfaces a photovoltaic cell, a regulated load, and a rechargeable battery. The objective is to maximize the end-to-end conversion efficiency of the EH PMU against temporal mismatch and variabilities of harvesting and load power. To minimize the involvement (charging or discharging) of a battery in the voltage conversion process, the proposed hybrid energy storage employs both battery and capacitor, which increases transient energy buffering capability and reduces the overall power conversion loss. Measurement results with 65-nm test chips show that the proposed EH PMU can achieve up to 2.2$\times $ higher end-to-end conversion efficiency than the conventional dual-mode architectures under testing cases emulating realistic load and harvesting power variabilities. We also devised a framework for the system design to guide capacitor sizing, buffering voltage range selection, and end-to-end efficiency tradeoffs. - 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An area-efficient microcontroller with an instruction-cache transformable to an ambient temperature sensor and a physically unclonable function
This paper presents a novel microcontroller-system-onchip (μC-SoC) for pervasive sensing systems, with a 6T SRAM instruction cache dynamically transformable to an ambient temperature sensor and physically unclonable function (PUF). As those sensing and PUF operations are performed in a duty-cycled manner in targeted systems, the proposed transformation can save silicon area, e.g., by ~9.8X as compared to dedicated sensor and PUF circuits that achieve comparable robustness with our temperature sensor and PUF. Specifically, the temperature sensor achieves -0.5/+1.5°C error with one-point calibration and 0.46°C/100mV power supply sensitivity; the PUF passes applicable NIST tests, achieves 0.97% unstable bits and 0.62% BER with TMV and comparator-input-swapping.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An area-efficient microcontroller with an instruction-cache transformable to an ambient temperature sensor and a physically unclonable function
This paper presents a novel microcontroller-system-onchip (μC-SoC) for pervasive sensing systems, with a 6T SRAM instruction cache dynamically transformable to an ambient temperature sensor and physically unclonable function (PUF). As those sensing and PUF operations are performed in a duty-cycled manner in targeted systems, the proposed transformation can save silicon area, e.g., by ~9.8X as compared to dedicated sensor and PUF circuits that achieve comparable robustness with our temperature sensor and PUF. Specifically, the temperature sensor achieves -0.5/+1.5°C error with one-point calibration and 0.46°C/100mV power supply sensitivity; the PUF passes applicable NIST tests, achieves 0.97% unstable bits and 0.62% BER with TMV and comparator-input-swapping.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-292
Triple-mode photovoltaic power management: Achieving high efficiency against harvesting and load variability
We present a triple-mode energy-harvesting power management unit (PMU) that interfaces a photovoltaic (PV) cell and delivers a regulated supply (VLoad) of 0.45V while storing remaining energy in a 3V rechargeable battery. The objective is to maximize the end-to-end conversion efficiency of the PMU against the variabilities of harvested energy and load power dissipation. Specifically, it uses an intermediate energy-storage capacitor to minimize the involvement (charging or discharging) of a battery in the conversion process over time. The experiments show that the proposed PMU can achieve 2.2× higher end-to-end conversion efficiency than the conventional dual-mode architectures when faced with typical variabilities in harvested energy and load power dissipation.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 289-292
Triple-mode photovoltaic power management: Achieving high efficiency against harvesting and load variability
We present a triple-mode energy-harvesting power management unit (PMU) that interfaces a photovoltaic (PV) cell and delivers a regulated supply (VLoad) of 0.45V while storing remaining energy in a 3V rechargeable battery. The objective is to maximize the end-to-end conversion efficiency of the PMU against the variabilities of harvested energy and load power dissipation. Specifically, it uses an intermediate energy-storage capacitor to minimize the involvement (charging or discharging) of a battery in the conversion process over time. The experiments show that the proposed PMU can achieve 2.2× higher end-to-end conversion efficiency than the conventional dual-mode architectures when faced with typical variabilities in harvested energy and load power dissipation.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Robust and in-situ self-testing technique for monitoring device aging effects in pipeline circuits
Runtime monitoring of aging effects in pipeline circuits is the key to dynamic reliability management techniques which can maximize the performance and energy-efficiency under a reliability envelope without imposing worst-case margin. The existing monitoring techniques are, however, severely limited: for sensor-based techniques, monitoring accuracy is significantly compromised due to the mismatches in aging conditions between sensors and the target circuits, as well as random variation of aging effects; for in-situ techniques, measurement results are sensitive to environmental variations during test phases, also severely reducing monitoring accuracy. We propose a new technique that enables accurate in-situ aging monitoring even under large environmental variations by (i) scaling the supply voltage for temperature-insensitive delay and (ii) reconfiguring target paths into ring oscillators, whose oscillation periods are measured and compared to pre-aging measurement to estimate aging-induced delay degradations. With additional accuracy-improving strategies, the technique achieves highly-accurate monitoring with an error of 15.5% across the temperature variations in self-test phases from 0°C to 80°C, exhibiting >30× improvement in accuracy as compared to the conventional technique operating at nominal supply voltage.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Robust and in-situ self-testing technique for monitoring device aging effects in pipeline circuits
Runtime monitoring of aging effects in pipeline circuits is the key to dynamic reliability management techniques which can maximize the performance and energy-efficiency under a reliability envelope without imposing worst-case margin. The existing monitoring techniques are, however, severely limited: for sensor-based techniques, monitoring accuracy is significantly compromised due to the mismatches in aging conditions between sensors and the target circuits, as well as random variation of aging effects; for in-situ techniques, measurement results are sensitive to environmental variations during test phases, also severely reducing monitoring accuracy. We propose a new technique that enables accurate in-situ aging monitoring even under large environmental variations by (i) scaling the supply voltage for temperature-insensitive delay and (ii) reconfiguring target paths into ring oscillators, whose oscillation periods are measured and compared to pre-aging measurement to estimate aging-induced delay degradations. With additional accuracy-improving strategies, the technique achieves highly-accurate monitoring with an error of 15.5% across the temperature variations in self-test phases from 0°C to 80°C, exhibiting >30× improvement in accuracy as compared to the conventional technique operating at nominal supply voltage.