Jayanta Kumar Biswas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jayanta Kumar Biswas has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Masud Rana
Department of Aerospace Engineering and Applied Mechanics IIEST, Shibpur Howrah India
18 shared publications Sandipan Roy
Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
8 shared publications- Santanu Kumar Karmakar
Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah 711103, West Bengal, India s:
6 shared publications - Amit Roy Chowdhury
Centre for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, India
5 shared publications Amit Roychowdhury
Department of Aerospace Engineering & Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, West Bengal, 711103, India
5 shared publicationsAnindya Malas
Department of Mechanical Engineering, NIT Patna, Department of Mechanical Engineering, NIT Patna, Bihar, India-800005, Patna, 800005, India
5 shared publications
Latest Publications
- 29 September 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
Design and biomechanical investigation of a patient-specific total talar prosthesis for total talar replacement: A finite element analysis
Background: Total talar replacement (TTR) is an emerging treatment for end-stage talar diseases, although concerns persist regarding ankle stability due to essential ligament transection. Further investigation is necessary regarding the biomechanical impact of patient-specific total talar prosthesis (TTP) on ankle stability and bone-implant mechanics. Objective: The purpose of this study is designing a patient-specific TTP and assess its biomechanical performance on ankle stability and stress distribution under various loading conditions using finite element analysis. Methods: A CT scan is used to create a 3D finite element model of the foot and ankle complex. The TTP made of A dual-material (UHMWPE talar body and titanium alloy cage) was created and fixed with five screws. Four loading conditions were simulated: inversion, eversion, dorsiflexion, and plantarflexion, with forces of 10 N, 50 N, 100 N, and 150 N. Talar tilt angles and von Mises stresses were examined for intact and implanted models. Results: In comparison to the intact ankle, TTR significantly decreased the talar tilt angles in inversion (12.5%–16%), eversion (6.6%–14%), and dorsiflexion (33%–47%). On the other hand, plantarflexion produced a larger tilt (34%–44%). While bone stresses stayed below 5 MPa, maximum implant stresses ranged from 20 to 80 MPa. The validation of the model against cadaveric studies was reliable. Conclusion: The patient-specific TTP with screw fixation improves ankle stability in most loading directions, potentially compensating for ligament insufficiency. However, greater plantarflexion instability necessitates post-operative measures. These findings provide biomechanical evidence that fixation-enhanced TTP designs can improve therapeutic outcomes.
- 29 September 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
Design and biomechanical investigation of a patient-specific total talar prosthesis for total talar replacement: A finite element analysis
Background: Total talar replacement (TTR) is an emerging treatment for end-stage talar diseases, although concerns persist regarding ankle stability due to essential ligament transection. Further investigation is necessary regarding the biomechanical impact of patient-specific total talar prosthesis (TTP) on ankle stability and bone-implant mechanics. Objective: The purpose of this study is designing a patient-specific TTP and assess its biomechanical performance on ankle stability and stress distribution under various loading conditions using finite element analysis. Methods: A CT scan is used to create a 3D finite element model of the foot and ankle complex. The TTP made of A dual-material (UHMWPE talar body and titanium alloy cage) was created and fixed with five screws. Four loading conditions were simulated: inversion, eversion, dorsiflexion, and plantarflexion, with forces of 10 N, 50 N, 100 N, and 150 N. Talar tilt angles and von Mises stresses were examined for intact and implanted models. Results: In comparison to the intact ankle, TTR significantly decreased the talar tilt angles in inversion (12.5%–16%), eversion (6.6%–14%), and dorsiflexion (33%–47%). On the other hand, plantarflexion produced a larger tilt (34%–44%). While bone stresses stayed below 5 MPa, maximum implant stresses ranged from 20 to 80 MPa. The validation of the model against cadaveric studies was reliable. Conclusion: The patient-specific TTP with screw fixation improves ankle stability in most loading directions, potentially compensating for ligament insufficiency. However, greater plantarflexion instability necessitates post-operative measures. These findings provide biomechanical evidence that fixation-enhanced TTP designs can improve therapeutic outcomes.
- 13 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 022002
Cervical implant fixation: a topical review of techniques and their importance
Cervical implant fixation is a critical surgical intervention for stabilizing the cervical spine, often necessitated by trauma, degenerative diseases, or spinal deformities. While spinal disc disease has historically been treated with fusion-based procedures, there has been a recent surge of interest in motion-preserving disc arthroplasties. The present study provides a topical narrative review of selected and recent literature on cervical implant fixation techniques, including anterior and posterior approaches, implant materials, biomechanical considerations, and reported clinical outcomes. Traditional fusion-based procedures have long been used to treat cervical disc disease, while recent years have seen increasing interest in motion-preserving techniques such as cervical disc arthroplasty. Developments in implant design and fixation strategies have contributed to improved radiographic and functional results compared with earlier systems, although each technique presents specific benefits and limitations. Cervical implant fixation has evolved into a highly sophisticated discipline that includes anterior, posterior, and motion-preserving techniques for treating a wide range of spinal conditions. This review summarises recent advances, common complications, and emerging trends in cervical fixation, and highlights existing research gaps to support future investigation and clinical decision-making.
- 13 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 022002
Cervical implant fixation: a topical review of techniques and their importance
Cervical implant fixation is a critical surgical intervention for stabilizing the cervical spine, often necessitated by trauma, degenerative diseases, or spinal deformities. While spinal disc disease has historically been treated with fusion-based procedures, there has been a recent surge of interest in motion-preserving disc arthroplasties. The present study provides a topical narrative review of selected and recent literature on cervical implant fixation techniques, including anterior and posterior approaches, implant materials, biomechanical considerations, and reported clinical outcomes. Traditional fusion-based procedures have long been used to treat cervical disc disease, while recent years have seen increasing interest in motion-preserving techniques such as cervical disc arthroplasty. Developments in implant design and fixation strategies have contributed to improved radiographic and functional results compared with earlier systems, although each technique presents specific benefits and limitations. Cervical implant fixation has evolved into a highly sophisticated discipline that includes anterior, posterior, and motion-preserving techniques for treating a wide range of spinal conditions. This review summarises recent advances, common complications, and emerging trends in cervical fixation, and highlights existing research gaps to support future investigation and clinical decision-making.
- 24 February 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 49 (2) , 141-149
Effect of pedicle-screw fixation on cervical spine: A comparative finite element analysis
Background: Pedicle-screw-fixation (PSF) is a widely used surgical technique for stabilizing the cervical spine in cases of trauma, degenerative diseases and deformities. However, the biomechanical effects of PSF on cervical spine stability remain a topic of research. Objective: This study employs finite-element-analysis (FEA) to investigate the influence of PSF on the cervical spine under various loading conditions. Methods: A three-dimensional (3D) finite element model of the cervical spine (C2–C7) is developed, validated and subjected to simulated flexion, extension, lateral bending and axial rotation. Four scenarios are compared: (1) Intact spine (C2–C7), (2) spine with PSF at fourth segment (C4–C5), (3) spine with PSF at fifth segment (C5–C6) and (4) spine with two level PSF at fourth and fifth segments (C4–C6). Results: The results demonstrate that due to single segment PSF, the total ROM (second to sixth segments) is reduced by 8.8%, 8.5%, 12.4% and 11.4% whereas two segment PSF shows that the total ROM is reduced by 24.2%, 23.3%, 23.5% and 25.3% under 1 N-m flexion, extension, lateral bending and rotations, respectively, in comparison to intact cervical spine. The maximum stresses on Titanium alloy (Ti-6Al-4V) Pedicle-screw are varied from 70 to 75 MPa and on PEEK rod are around 32–40 MPa, respectively. The maximum stresses on pedicle-screw and rod material are also below its yield stress. Conclusion: This present FE study provides the biomechanical efficacy of cervical PSF and its impact on spinal stability for restoring cervical spine biomechanics.
- 24 February 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 49 (2) , 141-149
Effect of pedicle-screw fixation on cervical spine: A comparative finite element analysis
Background: Pedicle-screw-fixation (PSF) is a widely used surgical technique for stabilizing the cervical spine in cases of trauma, degenerative diseases and deformities. However, the biomechanical effects of PSF on cervical spine stability remain a topic of research. Objective: This study employs finite-element-analysis (FEA) to investigate the influence of PSF on the cervical spine under various loading conditions. Methods: A three-dimensional (3D) finite element model of the cervical spine (C2–C7) is developed, validated and subjected to simulated flexion, extension, lateral bending and axial rotation. Four scenarios are compared: (1) Intact spine (C2–C7), (2) spine with PSF at fourth segment (C4–C5), (3) spine with PSF at fifth segment (C5–C6) and (4) spine with two level PSF at fourth and fifth segments (C4–C6). Results: The results demonstrate that due to single segment PSF, the total ROM (second to sixth segments) is reduced by 8.8%, 8.5%, 12.4% and 11.4% whereas two segment PSF shows that the total ROM is reduced by 24.2%, 23.3%, 23.5% and 25.3% under 1 N-m flexion, extension, lateral bending and rotations, respectively, in comparison to intact cervical spine. The maximum stresses on Titanium alloy (Ti-6Al-4V) Pedicle-screw are varied from 70 to 75 MPa and on PEEK rod are around 32–40 MPa, respectively. The maximum stresses on pedicle-screw and rod material are also below its yield stress. Conclusion: This present FE study provides the biomechanical efficacy of cervical PSF and its impact on spinal stability for restoring cervical spine biomechanics.
- 4 November 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 237 (11) , 1297-1305
In-silico study of type ‘B’ condylar head fractures and evaluating the influence of two positional screw distance in two-screw osteosynthesis construct
Clinical fixation screws are common in clinical practices to fix mandibular condyle fractures. Evidence suggests significance of ‘working length’ that is, distance between proximal and distal fixation screws in proximity to the fracture in orthopaedic implant design. In pursuit of stable implant-bone construct, this study aims to investigate the biomechanical performance of each configuration considered in the study and provide an optimal working length between the screws for clinical reference. Finite element models of virtually designed broken condyle as type ‘B’ were simulated and analysed in ANSYS Workbench. Screws are implanted according to previous literature at five varied distances ‘d’ maintaining five different ratios with the fracture length ‘D’. Based on a literature review, boundary conditions, muscle traction forces and non-linear contacts were assigned to obtain precise results. Each case is considered an individual configuration and von Mises distribution, microstrain in bone, screw-bone interface micromotion and fracture dislocation were evaluated for all these configurations. Stress-shielding phenomenon is observed for maximum von Mises stresses in bone. Microstrain concentration was significant in cancellous bone in the vicinity of the screw around the fracture line. Configurations were compared based on the stress-strain along with micromotion to support the required amount of osseointegration between implant and bone. Presented data from all five conditions supported the assumption that under physiological loading conditions, the D3 configuration provided stability for fracture healing. Further research on screw shapes, diameters and material properties, or investigating the direction of forces within the screws could provide further insight into this topic.
- 4 November 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 237 (11) , 1297-1305
In-silico study of type ‘B’ condylar head fractures and evaluating the influence of two positional screw distance in two-screw osteosynthesis construct
Clinical fixation screws are common in clinical practices to fix mandibular condyle fractures. Evidence suggests significance of ‘working length’ that is, distance between proximal and distal fixation screws in proximity to the fracture in orthopaedic implant design. In pursuit of stable implant-bone construct, this study aims to investigate the biomechanical performance of each configuration considered in the study and provide an optimal working length between the screws for clinical reference. Finite element models of virtually designed broken condyle as type ‘B’ were simulated and analysed in ANSYS Workbench. Screws are implanted according to previous literature at five varied distances ‘d’ maintaining five different ratios with the fracture length ‘D’. Based on a literature review, boundary conditions, muscle traction forces and non-linear contacts were assigned to obtain precise results. Each case is considered an individual configuration and von Mises distribution, microstrain in bone, screw-bone interface micromotion and fracture dislocation were evaluated for all these configurations. Stress-shielding phenomenon is observed for maximum von Mises stresses in bone. Microstrain concentration was significant in cancellous bone in the vicinity of the screw around the fracture line. Configurations were compared based on the stress-strain along with micromotion to support the required amount of osseointegration between implant and bone. Presented data from all five conditions supported the assumption that under physiological loading conditions, the D3 configuration provided stability for fracture healing. Further research on screw shapes, diameters and material properties, or investigating the direction of forces within the screws could provide further insight into this topic.
- 5 April 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (3) , 1-47
Finite Element Analysis of Maxillary Anterior Dentition During Retraction With Varying Level of Bone Support
This study is being carried out to evaluate and compare the stress along the root surfaces of anterior maxillary dentition during retraction in labial and lingual mechanics with varying level of bone support. Eight three-dimensional finite element models (FEM) were created with normal periodontium and different levels of alveolar bone loss; four with labial brackets and four with lingual brackets. Sliding mechanics were simulated as en-masse retraction of the anterior dentition. The equivalent stresses along the roots of six anterior maxillary teeth were measured in all the models. Equivalent stresses generated at the root surfaces of central incisors are always higher in labial technique and of canines are always higher in lingual technique, suggesting the increased vulnerability toward root resorption in both cases. Stresses at the root apices of all the teeth are increasing progressively when the bone loss is progressively more than 2 mm in labial technique. In labial technique, the stresses at the root apices of all the teeth are increasing progressively when the bone loss is progressively more than 2 mm. In Lingual technique, equivalent stresses generated at the root surfaces of canines are more than central and lateral incisors irrespective of the alveolar bone loss, suggesting increased susceptibility to root resorption.
- 5 April 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (3) , 1-47
Finite Element Analysis of Maxillary Anterior Dentition During Retraction With Varying Level of Bone Support
This study is being carried out to evaluate and compare the stress along the root surfaces of anterior maxillary dentition during retraction in labial and lingual mechanics with varying level of bone support. Eight three-dimensional finite element models (FEM) were created with normal periodontium and different levels of alveolar bone loss; four with labial brackets and four with lingual brackets. Sliding mechanics were simulated as en-masse retraction of the anterior dentition. The equivalent stresses along the roots of six anterior maxillary teeth were measured in all the models. Equivalent stresses generated at the root surfaces of central incisors are always higher in labial technique and of canines are always higher in lingual technique, suggesting the increased vulnerability toward root resorption in both cases. Stresses at the root apices of all the teeth are increasing progressively when the bone loss is progressively more than 2 mm in labial technique. In labial technique, the stresses at the root apices of all the teeth are increasing progressively when the bone loss is progressively more than 2 mm. In Lingual technique, equivalent stresses generated at the root surfaces of canines are more than central and lateral incisors irrespective of the alveolar bone loss, suggesting increased susceptibility to root resorption.
- 13 March 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (3) , 1-26
A Finite Element Based Comparative Study of Lumbosacral Pedicle Screw Fixation and Artificial Disc Replacement
The aim of this is to evaluate the biomechanical performance of double-level semirigid pedicle screw fixation and artificial intervertebral disc replacement in lumbar spine. Ti6Al4V and CFR-PEEK material are used for pedicle screw fixation and artificial disc replacement. In the present study, pedicle screw fixation and artificial intervertebral disc replacement are carried out between L3-L4-L5 regions under the application of moment 6,8,10 Nm and range of motion is compared during flexion, extension, and right-left lateral bending. Two-level pedicle screw fusion and total disc replacement are developed in the L3-L4-L5 of the lumber spine vertebrae. Carbon fiber reinforced (CFR-PEEK) and ultra-high molecular weight polyethylene (UHMWPE) are considered for the spinal fusion and the core part of the artificial disc respectively. Afterwards, applying the finite element analysis, it is detected that CFR-PEEK rod is able to increase range of motion at the implanted level in comparison to Ti6Al4V rod for both flexion–extension and lateral bending. In case of artificial intervertebral disc replacement hypermobility was observed. Hence, it is significant that rod material with CFR-PEEK is a better alternative for the treatment of degenerative diseases.
- 13 March 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (3) , 1-26
A Finite Element Based Comparative Study of Lumbosacral Pedicle Screw Fixation and Artificial Disc Replacement
The aim of this is to evaluate the biomechanical performance of double-level semirigid pedicle screw fixation and artificial intervertebral disc replacement in lumbar spine. Ti6Al4V and CFR-PEEK material are used for pedicle screw fixation and artificial disc replacement. In the present study, pedicle screw fixation and artificial intervertebral disc replacement are carried out between L3-L4-L5 regions under the application of moment 6,8,10 Nm and range of motion is compared during flexion, extension, and right-left lateral bending. Two-level pedicle screw fusion and total disc replacement are developed in the L3-L4-L5 of the lumber spine vertebrae. Carbon fiber reinforced (CFR-PEEK) and ultra-high molecular weight polyethylene (UHMWPE) are considered for the spinal fusion and the core part of the artificial disc respectively. Afterwards, applying the finite element analysis, it is detected that CFR-PEEK rod is able to increase range of motion at the implanted level in comparison to Ti6Al4V rod for both flexion–extension and lateral bending. In case of artificial intervertebral disc replacement hypermobility was observed. Hence, it is significant that rod material with CFR-PEEK is a better alternative for the treatment of degenerative diseases.
- 6 March 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (21) , 4933-4945
A biomechanical finite element study to assess the suitability of implantation on lumbar vertebrae L4-L5
Instability in the spinal section along with the cases of degeneration is commonly cured by the pedicle screw fixation system. The present work aims at the identification of suitable instrumentation at the spinal segment L4-L5 through finite element method and compared with an intact spine. Vertebral section (L3- Coccyx) upper surface L3 were subjected to various axial compressive forces for the body weights of 17, 67, 100 and 167 kg under the different physiological motion conditions such as rotation, flexion, extension and bending. Considering Intact as 100% the calculated results of equivalent stress on IVD-L34, L45 and L5S are as 90%, 43% and 76% during flexion, for extension 118%, 26% and 108%, during bending 58%, 58% and 80% and during rotation 57%, 46%, 74% respectively are the lowest for 6 mm instrumentation as compared to other instrumentation model. It was also observed that the load on the cortical and annulus region were highest as compared to the cancellous and nucleus region. The results of the present study can contribute to explaining fracture and intervertebral disc replacement cases subjected to pedicle screw implantation.
- 6 March 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (21) , 4933-4945
A biomechanical finite element study to assess the suitability of implantation on lumbar vertebrae L4-L5
Instability in the spinal section along with the cases of degeneration is commonly cured by the pedicle screw fixation system. The present work aims at the identification of suitable instrumentation at the spinal segment L4-L5 through finite element method and compared with an intact spine. Vertebral section (L3- Coccyx) upper surface L3 were subjected to various axial compressive forces for the body weights of 17, 67, 100 and 167 kg under the different physiological motion conditions such as rotation, flexion, extension and bending. Considering Intact as 100% the calculated results of equivalent stress on IVD-L34, L45 and L5S are as 90%, 43% and 76% during flexion, for extension 118%, 26% and 108%, during bending 58%, 58% and 80% and during rotation 57%, 46%, 74% respectively are the lowest for 6 mm instrumentation as compared to other instrumentation model. It was also observed that the load on the cortical and annulus region were highest as compared to the cancellous and nucleus region. The results of the present study can contribute to explaining fracture and intervertebral disc replacement cases subjected to pedicle screw implantation.
- 30 November 2022
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (01)
A FINITE ELEMENT ANALYSIS OF SEMI-RIGID SINGLE AND TWO LEVEL PEDICLE SCREW-ROD FIXATION IN LUMBAR SPINE
For the treatment of degenerative disc disease (DDD) and associated back pain and instability in the spinal segments, the success of pedicle screw-based spinal implant system has been found in the literature. Over the last couple of years, various nonfusion implants are made for the treatment of minor DDD. In this study, the biomechanical response of pedicle screw-based implant with semi-rigid rod material on the lumbar spine is evaluated. Computed tomography (CT) scan-based finite element (FE) model is used to evaluate the performance of pedicle screw fixation with flexible rods made of carbon fiber-reinforced polyetheretherketone (CFR PEEK). Typical physiological loadings are applied to the intact and implanted lumbar spine model. It is observed that the pediclescrew with the CFR-PEEK rod can restore the range of motion (ROM) on the surgical segment. The CFR-PEEK RODs carried out more loads and reduced the stress on the vertebral body. Using traditional rigid rods, ROM is generally almost restricted on the fusion zone, which can be improved by CFR-PEEK rod system to a certain degree. After successful experimental validation and clinical trial, the CFR-PEEK rod may be recommended for improved clinical outcomes.
- 30 November 2022
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (01)
A FINITE ELEMENT ANALYSIS OF SEMI-RIGID SINGLE AND TWO LEVEL PEDICLE SCREW-ROD FIXATION IN LUMBAR SPINE
For the treatment of degenerative disc disease (DDD) and associated back pain and instability in the spinal segments, the success of pedicle screw-based spinal implant system has been found in the literature. Over the last couple of years, various nonfusion implants are made for the treatment of minor DDD. In this study, the biomechanical response of pedicle screw-based implant with semi-rigid rod material on the lumbar spine is evaluated. Computed tomography (CT) scan-based finite element (FE) model is used to evaluate the performance of pedicle screw fixation with flexible rods made of carbon fiber-reinforced polyetheretherketone (CFR PEEK). Typical physiological loadings are applied to the intact and implanted lumbar spine model. It is observed that the pediclescrew with the CFR-PEEK rod can restore the range of motion (ROM) on the surgical segment. The CFR-PEEK RODs carried out more loads and reduced the stress on the vertebral body. Using traditional rigid rods, ROM is generally almost restricted on the fusion zone, which can be improved by CFR-PEEK rod system to a certain degree. After successful experimental validation and clinical trial, the CFR-PEEK rod may be recommended for improved clinical outcomes.
- 13 October 2022
- Published by Elsevier in The American Journal of Surgery
- Vol. 225 (4) , 709-714
Predictors of 90-day morbidity and mortality after Frey procedure for chronic pancreatitis
- 13 October 2022
- Published by Elsevier in The American Journal of Surgery
- Vol. 225 (4) , 709-714
Predictors of 90-day morbidity and mortality after Frey procedure for chronic pancreatitis
- 26 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (5) , 992-1003
A finite element study and mathematical modeling of lumbar pedicle screw along with various design parameters
- 26 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (5) , 992-1003
A finite element study and mathematical modeling of lumbar pedicle screw along with various design parameters