Wolfgang Osten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wolfgang Osten has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
- Tobias Haist
Institute of Applied Optics University of Stuttgart Stuttgart Germany
8 shared publications - Giancarlo Pedrini
Univ. Stuttgart (Germany)
7 shared publications - Giancarlo Pedrini
Univ Stuttgart, Inst Tech Opt, Pfaffenwaldring 9, D-70569 Stuttgart, Germany
6 shared publications - Liwei Fu
Univ. Stuttgart (Germany)
5 shared publications Karsten Frenner
4 shared publications- Karsten Frenner
Univ. Stuttgart (Germany)
4 shared publications
Latest Publications
- Open Access
- 21 December 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 162
Simulation of realistic speckle fields by using surface integral equation and multi-level fast multipole method
- 21 December 2022
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 162
Open AccessSimulation of realistic speckle fields by using surface integral equation and multi-level fast multipole method
- 3 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12223, 91-99
Holography: a 60 years journey with outstanding achievements
In this paper we look back to 60 years of holograpy. Special attention is given to its application for non-destructive testing and experimental stress analysis. Across these years both techniques have shown to be versatile tools for the solution of many inspection problems. Their main advantages are the non-contact nature, the non-destructive and areal working principle, the fast response, high sensitivity, resolution and accuracy. In contrast to conventional techniques such as classical interferometry, the holographic principle of wave front storage and reconstruction made it possible to investigate objects with rough surfaces that experience any change by temporal wave front division. The paper reviews the history of holographic metrology, honors the inventors of the main principles, and shows exemplary applications. However, the main focus is on modern developments that are inspired by the rapid technological process in sensing technology and digitization, current applications and future challenges.
- 3 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12223, 91-99
Holography: a 60 years journey with outstanding achievements
In this paper we look back to 60 years of holograpy. Special attention is given to its application for non-destructive testing and experimental stress analysis. Across these years both techniques have shown to be versatile tools for the solution of many inspection problems. Their main advantages are the non-contact nature, the non-destructive and areal working principle, the fast response, high sensitivity, resolution and accuracy. In contrast to conventional techniques such as classical interferometry, the holographic principle of wave front storage and reconstruction made it possible to investigate objects with rough surfaces that experience any change by temporal wave front division. The paper reviews the history of holographic metrology, honors the inventors of the main principles, and shows exemplary applications. However, the main focus is on modern developments that are inspired by the rapid technological process in sensing technology and digitization, current applications and future challenges.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 17, OF2B.6
Adapting the Design of the Modal Holographic Wavefront Sensor to Present Atmospheric Turbulence Conditions
The modal holographic wavefront sensor enables fast measurements of individual aberration modes without the need for time-consuming calculations. To minimize the effect of inter-modal crosstalk on the measurement accuracy, we present sensor optimization and show its performance in closed-loop adaptive optics in simulation.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 17, OF2B.6
Adapting the Design of the Modal Holographic Wavefront Sensor to Present Atmospheric Turbulence Conditions
The modal holographic wavefront sensor enables fast measurements of individual aberration modes without the need for time-consuming calculations. To minimize the effect of inter-modal crosstalk on the measurement accuracy, we present sensor optimization and show its performance in closed-loop adaptive optics in simulation.
- Open Access
- 1 January 2022
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Light: Advanced Manufacturing
- Vol. 3 (3) , 384-399
Simulation-based design optimization of the holographic wavefront sensor in closed-loop adaptive optics
- 1 January 2022
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Light: Advanced Manufacturing
- Vol. 3 (3) , 384-399
Open AccessSimulation-based design optimization of the holographic wavefront sensor in closed-loop adaptive optics
- Open Access
- 10 January 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 504-513
Hochgenaue Kalibrierung eines holografischen Multi-Punkt-Positionsmesssystems
Zusammenfassung: Mit einem Multi-Punkt-Positionsmesssystem ist es möglich, Positionen und Orientierungen mit sehr hoher Genauigkeit bildbasiert zu messen. Das Messsystem besteht aus einem einfachen Kamerasystem, das um ein diffraktives optisches Element (DOE) erweitert wird. Durch die Multi-Punkt-Methode (MPM) werden Messunsicherheiten von deutlich unter 1/100 Pixel erzielt. Um dies in der Praxis anwenden zu können, ist eine entsprechend hochgenaue Kalibrierung nötig. In diesem Beitrag werden verschiedene Kalibrierverfahren und -funktionen vorgestellt und untersucht. Die Auswertung zeigt, dass sich zur Kalibrierung ein allgemeiner Polynomansatz zusammen mit der Nanomess- und Positioniermaschine NPMM-200 am besten eignet. Es werden Standardabweichungen des Restfehlers von 0,31 µm im Objektraum (etwa 6/1000 Pixel im Bildraum) auf einer Fläche von etwa 87 mm × 49 mm 87\hspace{0.1667em}\text{mm}\times 49\hspace{0.1667em}\text{mm} erreicht (Polynomgrad = 9).
- 10 January 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 504-513
Open AccessHochgenaue Kalibrierung eines holografischen Multi-Punkt-Positionsmesssystems
Zusammenfassung: Mit einem Multi-Punkt-Positionsmesssystem ist es möglich, Positionen und Orientierungen mit sehr hoher Genauigkeit bildbasiert zu messen. Das Messsystem besteht aus einem einfachen Kamerasystem, das um ein diffraktives optisches Element (DOE) erweitert wird. Durch die Multi-Punkt-Methode (MPM) werden Messunsicherheiten von deutlich unter 1/100 Pixel erzielt. Um dies in der Praxis anwenden zu können, ist eine entsprechend hochgenaue Kalibrierung nötig. In diesem Beitrag werden verschiedene Kalibrierverfahren und -funktionen vorgestellt und untersucht. Die Auswertung zeigt, dass sich zur Kalibrierung ein allgemeiner Polynomansatz zusammen mit der Nanomess- und Positioniermaschine NPMM-200 am besten eignet. Es werden Standardabweichungen des Restfehlers von 0,31 µm im Objektraum (etwa 6/1000 Pixel im Bildraum) auf einer Fläche von etwa 87 mm × 49 mm 87\hspace{0.1667em}\text{mm}\times 49\hspace{0.1667em}\text{mm} erreicht (Polynomgrad = 9).
- Open Access
- 4 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (2) , 1102-1110
Residual Stress Evaluation in Ceramic Coating Under Industrial Conditions by Digital Holography
We describe a system suitable for the evaluation of residual stress in ceramic coating under industrial conditions. Laser ablation is used for material removal and digital holography measures the displacements produced by the residual stress release around the processed area. The residual stresses at different depths below the surface of the coating are calculated by Finite Element Method (FEM) from: the displacements, the shapes of the machined surface and the material parameters. Experimental results are presented.
- 4 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (2) , 1102-1110
Open AccessResidual Stress Evaluation in Ceramic Coating Under Industrial Conditions by Digital Holography
We describe a system suitable for the evaluation of residual stress in ceramic coating under industrial conditions. Laser ablation is used for material removal and digital holography measures the displacements produced by the residual stress release around the processed area. The residual stresses at different depths below the surface of the coating are calculated by Finite Element Method (FEM) from: the displacements, the shapes of the machined surface and the material parameters. Experimental results are presented.
- 12 July 2019
- Published by SPIE-Intl Soc Optical Eng
- p. 15
Deformation measurement of large buildings by holographical point replication
- 12 July 2019
- Published by SPIE-Intl Soc Optical Eng
- p. 15
Deformation measurement of large buildings by holographical point replication
- 9 March 2019
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 86 (6) , 309-318
Topografiemessung an verkapselten mikroelektromechanischen Systemen mittels Kurzkohärenz-Interferometrie
Zusammenfassung: Mikroelektromechanische Systeme (MEMS) werden heute in einer Vielzahl von Anwendungen eingesetzt. Zur Herstellung von MEMS werden üblicherweise fotolithografische Verfahren eingesetzt. Insbesondere bei sicherheitsrelevanten MEMS, wie z. B. Airbag- oder ESP-Sensoren, ist eine 100 % Inspektion erforderlich. Nach einer optischen Inspektion der MEMS-Strukturen werden diese durch das Bonden eines Silizium-Kappenwafers geschützt. Dieses Bonding oder das anschließende Packaging kann zu einer zusätzlichen Spannung im Waferstapel führen, die die MEMS-Funktion negativ beeinflussen kann. Im Falle eines fehlgeschlagenen elektronischen Tests kann das Problem nicht lokalisiert werden, da der Kappenwafer für die gängigen optischen Oberflächensensoren undurchsichtig ist. In dieser Publikation wird die Herausforderung der optischen Topografiemessung von verkapselten MEMS-Strukturen diskutiert. Dabei werden Defekte wie Verbiegung oder Festklemmen einzelner MEMS-Finger betrachtet. Für diese Messaufgabe wird ein kurzkohärentes Interferenzmikroskop implementiert. Die Wellenlänge liegt im Short-Wave Infrarot (SWIR), da Silizium im Infraroten transparent wird. Die interferometrische Oberflächenmessung der MEMS-Strukturen wird durch den Kappenwafer stark beeinflusst. Hierfür wurden Simulationen durchgeführt, die die systematischen Messabweichungen aufgrund der Kappe zeigen. Eine Möglichkeit zur Korrektur und Reduzierung der systematischen Abweichungen wird ebenfalls beschrieben.
- 9 March 2019
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 86 (6) , 309-318
Topografiemessung an verkapselten mikroelektromechanischen Systemen mittels Kurzkohärenz-Interferometrie
Zusammenfassung: Mikroelektromechanische Systeme (MEMS) werden heute in einer Vielzahl von Anwendungen eingesetzt. Zur Herstellung von MEMS werden üblicherweise fotolithografische Verfahren eingesetzt. Insbesondere bei sicherheitsrelevanten MEMS, wie z. B. Airbag- oder ESP-Sensoren, ist eine 100 % Inspektion erforderlich. Nach einer optischen Inspektion der MEMS-Strukturen werden diese durch das Bonden eines Silizium-Kappenwafers geschützt. Dieses Bonding oder das anschließende Packaging kann zu einer zusätzlichen Spannung im Waferstapel führen, die die MEMS-Funktion negativ beeinflussen kann. Im Falle eines fehlgeschlagenen elektronischen Tests kann das Problem nicht lokalisiert werden, da der Kappenwafer für die gängigen optischen Oberflächensensoren undurchsichtig ist. In dieser Publikation wird die Herausforderung der optischen Topografiemessung von verkapselten MEMS-Strukturen diskutiert. Dabei werden Defekte wie Verbiegung oder Festklemmen einzelner MEMS-Finger betrachtet. Für diese Messaufgabe wird ein kurzkohärentes Interferenzmikroskop implementiert. Die Wellenlänge liegt im Short-Wave Infrarot (SWIR), da Silizium im Infraroten transparent wird. Die interferometrische Oberflächenmessung der MEMS-Strukturen wird durch den Kappenwafer stark beeinflusst. Hierfür wurden Simulationen durchgeführt, die die systematischen Messabweichungen aufgrund der Kappe zeigen. Eine Möglichkeit zur Korrektur und Reduzierung der systematischen Abweichungen wird ebenfalls beschrieben.
- Open Access
- 3 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2147
Variable Wavefront Curvature Phase Retrieval Compared to Off-Axis Holography and Its Useful Application to Support Intraoperative Tissue Discrimination
Quantitative phase imaging can reveal morphological features without having to stain the biological sample. This property has important implications for intraoperative applications since the time spent during histopathology can be reduced from a few minutes to a few seconds. However, most common quantitative phase imaging techniques are based on the interferometric principle, which makes them more prone to disturbing environmental influences, such as temperature drift and air turbulence. In the last decade, with the advance of computing power, many different iterative quantitative phase imaging techniques, which only require the recording of the diffracted wavefield, and therefore offer increased robustness towards environmental disturbances, have been proposed. These are particularly well-suited for the application outside the well-controlled lab environment such as an operating theatre. The optical performance of our developed iterative phase retrieval method based on variable wavefront curvature will be evaluated by reference to off-axis digital holography and applied for intraoperative discrimination of tissue.
- 3 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2147
Open AccessVariable Wavefront Curvature Phase Retrieval Compared to Off-Axis Holography and Its Useful Application to Support Intraoperative Tissue Discrimination
Quantitative phase imaging can reveal morphological features without having to stain the biological sample. This property has important implications for intraoperative applications since the time spent during histopathology can be reduced from a few minutes to a few seconds. However, most common quantitative phase imaging techniques are based on the interferometric principle, which makes them more prone to disturbing environmental influences, such as temperature drift and air turbulence. In the last decade, with the advance of computing power, many different iterative quantitative phase imaging techniques, which only require the recording of the diffracted wavefield, and therefore offer increased robustness towards environmental disturbances, have been proposed. These are particularly well-suited for the application outside the well-controlled lab environment such as an operating theatre. The optical performance of our developed iterative phase retrieval method based on variable wavefront curvature will be evaluated by reference to off-axis digital holography and applied for intraoperative discrimination of tissue.