David B. Miklos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David B. Miklos has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Karl G. Linden
University of Colorado Boulder
5 shared publications - Uwe Hübner
Chair of Urban Water Systems Engineering, Technical University of Munich, Am Coulombwall 3, Garching D-85748, Germany
5 shared publications - Joerg E. Drewes
Technical University of Munich
3 shared publications - Christian Remy
Kompetenzzentrum Wasser Berlin gGmbH, Cicerostr 24, D-10709 Berlin, Germany
1 shared publication J.E. Drewes
1 shared publication- Jean-Philippe Croué
Curtin Water Quality Research Centre, Department of Chemistry, Curtin University, GPO Box U1987, Perth, WA 6845, Australia
1 shared publication
Latest Publications
- 1 April 2019
- Published by Elsevier in Chemical Engineering Journal
- Vol. 362, 537-547
Comparison of UV-AOPs (UV/H2O2, UV/PDS and UV/Chlorine) for TOrC removal from municipal wastewater effluent and optical surrogate model evaluation
- 1 April 2019
- Published by Elsevier in Chemical Engineering Journal
- Vol. 362, 537-547
Comparison of UV-AOPs (UV/H2O2, UV/PDS and UV/Chlorine) for TOrC removal from municipal wastewater effluent and optical surrogate model evaluation
- 1 November 2018
- Published by Elsevier in Water Research
- Vol. 145, 487-497
Removal of trace organic chemicals in wastewater effluent by UV/H2O2 and UV/PDS
- 1 November 2018
- Published by Elsevier in Water Research
- Vol. 145, 487-497
Removal of trace organic chemicals in wastewater effluent by UV/H2O2 and UV/PDS
- Top Cited Papers
- 1 August 2018
- Published by Elsevier in Water Research
- Vol. 139, 118-131
Evaluation of advanced oxidation processes for water and wastewater treatment – A critical review
- 1 August 2018
- Published by Elsevier in Water Research
- Vol. 139, 118-131
Top Cited PapersEvaluation of advanced oxidation processes for water and wastewater treatment – A critical review
- 22 June 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 4 (9) , 1321-1330
Improving UV/H2O2 performance following tertiary treatment of municipal wastewater
The ability of UV/AOP to treat trace organic contaminants (TOrCs) in wastewater is inhibited by (1) UV light-absorbing species and (2) hydroxyl radical (˙OH) scavenging species. We address these challenges by investigating four diverse technologies, single-stage biofiltration, sequential biofiltration, coagulation–flocculation–sedimentation–filtration (CFSF), and nanofiltration, as options for improving water quality conditions just prior to UV treatment, with and without added hydrogen peroxide (H2O2). By evaluating UV254 transmittance (UVT), ˙OH scavengers, and ˙OH steady-state concentrations, we found nanofiltration treatment to produce the most favorable pre-UV and UV/H2O2 water quality conditions. In comparing CFSF, single-stage biofiltration and sequential biofiltration treatment, CFSF treatment resulted in the highest increase in UVT and all three technologies reduced the scavenging capacity by ∼24% despite differences in removal of typical ˙OH scavengers. UV and UV/H2O2 performance were evaluated by tracking the degradation rates of 11 targeted TOrCs for each pre-UV/H2O2 treatment scenario. Applying the additional treatment, average pseudo first-order degradation rates of TOrCs under UV/H2O2 increased by 20 to 92%, informing potential strategies to increase the oxidation potential of UV/AOP systems applied to wastewater.
- 22 June 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 4 (9) , 1321-1330
Improving UV/H2O2 performance following tertiary treatment of municipal wastewater
The ability of UV/AOP to treat trace organic contaminants (TOrCs) in wastewater is inhibited by (1) UV light-absorbing species and (2) hydroxyl radical (˙OH) scavenging species. We address these challenges by investigating four diverse technologies, single-stage biofiltration, sequential biofiltration, coagulation–flocculation–sedimentation–filtration (CFSF), and nanofiltration, as options for improving water quality conditions just prior to UV treatment, with and without added hydrogen peroxide (H2O2). By evaluating UV254 transmittance (UVT), ˙OH scavengers, and ˙OH steady-state concentrations, we found nanofiltration treatment to produce the most favorable pre-UV and UV/H2O2 water quality conditions. In comparing CFSF, single-stage biofiltration and sequential biofiltration treatment, CFSF treatment resulted in the highest increase in UVT and all three technologies reduced the scavenging capacity by ∼24% despite differences in removal of typical ˙OH scavengers. UV and UV/H2O2 performance were evaluated by tracking the degradation rates of 11 targeted TOrCs for each pre-UV/H2O2 treatment scenario. Applying the additional treatment, average pseudo first-order degradation rates of TOrCs under UV/H2O2 increased by 20 to 92%, informing potential strategies to increase the oxidation potential of UV/AOP systems applied to wastewater.
- 1 June 2018
- Published by Elsevier in Water Research
- Vol. 136, 169-179
UV/H2O2 process stability and pilot-scale validation for trace organic chemical removal from wastewater treatment plant effluents
- 1 June 2018
- Published by Elsevier in Water Research
- Vol. 136, 169-179
UV/H2O2 process stability and pilot-scale validation for trace organic chemical removal from wastewater treatment plant effluents