Jui Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jui Fang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Po-Hsiang Tsui
Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan
5 shared publications - Yi-Wen Chen
Advanced Therapeutic and Pharmaceutical Center, China Medical University Hospital
3 shared publications Chon-Haw Tsai
2 shared publicationsChun-Hsu Yao
2 shared publications- Ming-Wei Lai
Liver Research Center, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan
2 shared publications - Tang-Chuan Wang
Affiliations School of Medicine, College of Medicine, China Medical University, Taichung City, Taiwan, Department of Master Program for Biomedical Engineering, College of Biomedical Engineering, China Medical University, Taichung City, Taiwan, Department of Otorhinolaryngology-Head and Neck Surgery, China Medical University Hsinchu Hospital, Zhubei City, Hsinchu County, Taiwan
2 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Redefining transient evoked otoacoustic emissions through multi-frequency sample entropy for assessment of outer hair cells related tinnitus among inner ear disorders
- 9 July 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessRedefining transient evoked otoacoustic emissions through multi-frequency sample entropy for assessment of outer hair cells related tinnitus among inner ear disorders
- Open Access
- 24 August 2023
- Published by Elsevier in Applied Acoustics
- Vol. 212
Quantification of transient evoked otoacoustic emissions by sample entropy to assess cochlear symptoms (Hearing and Tinnitus) in Meniere’s disease
- 24 August 2023
- Published by Elsevier in Applied Acoustics
- Vol. 212
Open AccessQuantification of transient evoked otoacoustic emissions by sample entropy to assess cochlear symptoms (Hearing and Tinnitus) in Meniere’s disease
- Open Access
- 29 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (4) , 741
Imaging the Effects of Whole-Body Vibration on the Progression of Hepatic Steatosis by Quantitative Ultrasound Based on Backscatter Envelope Statistics
Hepatic steatosis causes nonalcoholic fatty liver disease. Whole-body vibration (WBV) has been recommended to allow patients who have difficulty engaging in exercise to improve the grade of hepatic steatosis. This study proposed using ultrasound parametric imaging of the homodyned K (HK) distribution to evaluate the effectiveness of WBV treatments in alleviating hepatic steatosis. Sixty mice were assigned to control (n = 6), sedentary (n = 18), WBV (n = 18), and exercise (swimming) (n = 18) groups. Mice were fed a high-fat diet to induce hepatic steatosis and underwent the intervention for 4, 8, and 16 weeks. Ultrasound scanning was performed in vivo on each mouse after the interventions for ultrasound HK imaging using the parameter μ (the scatterer clustering parameter). Histopathological examinations and the intraperitoneal glucose tolerance test were carried out for comparisons with ultrasound findings. At the 16th week, WBV and exercise groups demonstrated lower body weights, glucose concentrations, histopathological scores (steatosis and steatohepatitis), and μ parameters than the control group (p < 0.05). The steatosis grade was significantly lower in the WBV group (mild) than in the exercise group (moderate) (p < 0.05), corresponding to a reduction in the μ parameter. A further analysis revealed that the correlation between the steatosis grade and the μ parameter was 0.84 (p < 0.05). From this animal study we conclude that WBV may be more effective than exercise in reducing the progression of hepatic steatosis, and ultrasound HK parametric imaging is an appropriate method for evaluating WBV’s effect on hepatic steatosis.
- 29 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (4) , 741
Open AccessImaging the Effects of Whole-Body Vibration on the Progression of Hepatic Steatosis by Quantitative Ultrasound Based on Backscatter Envelope Statistics
Hepatic steatosis causes nonalcoholic fatty liver disease. Whole-body vibration (WBV) has been recommended to allow patients who have difficulty engaging in exercise to improve the grade of hepatic steatosis. This study proposed using ultrasound parametric imaging of the homodyned K (HK) distribution to evaluate the effectiveness of WBV treatments in alleviating hepatic steatosis. Sixty mice were assigned to control (n = 6), sedentary (n = 18), WBV (n = 18), and exercise (swimming) (n = 18) groups. Mice were fed a high-fat diet to induce hepatic steatosis and underwent the intervention for 4, 8, and 16 weeks. Ultrasound scanning was performed in vivo on each mouse after the interventions for ultrasound HK imaging using the parameter μ (the scatterer clustering parameter). Histopathological examinations and the intraperitoneal glucose tolerance test were carried out for comparisons with ultrasound findings. At the 16th week, WBV and exercise groups demonstrated lower body weights, glucose concentrations, histopathological scores (steatosis and steatohepatitis), and μ parameters than the control group (p < 0.05). The steatosis grade was significantly lower in the WBV group (mild) than in the exercise group (moderate) (p < 0.05), corresponding to a reduction in the μ parameter. A further analysis revealed that the correlation between the steatosis grade and the μ parameter was 0.84 (p < 0.05). From this animal study we conclude that WBV may be more effective than exercise in reducing the progression of hepatic steatosis, and ultrasound HK parametric imaging is an appropriate method for evaluating WBV’s effect on hepatic steatosis.
- Open Access
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 9, 1-12
Ultrasound Sample Entropy Imaging: A New Approach for Evaluating Hepatic Steatosis and Fibrosis
Objective: Hepatic steatosis causes nonalcoholic fatty liver disease and may progress to fibrosis. Ultrasound is the first-line approach to examining hepatic steatosis. Fatty droplets in the liver parenchyma alter ultrasound radiofrequency (RF) signal statistical properties. This study proposes using sample entropy, a measure of irregularity in time-series data determined by the dimension$m$ and tolerance$r$ , for ultrasound parametric imaging of hepatic steatosis and fibrosis. Methods: Liver donors and patients were enrolled, and their hepatic fat fraction (HFF) ($n =72$ ), steatosis grade ($n =286$ ), and fibrosis score ($n =65$ ) were measured to verify the results of sample entropy imaging using sliding-window processing of ultrasound RF data. Results: The sample entropy calculated using$m =$ 4 and$r =0.1$ was highly correlated with the HFF when a small window with a side length of one pulse was used. The areas under the receiver operating characteristic curve for detecting hepatic steatosis that was$\ge $ mild,$\ge $ moderate, and$\ge $ severe were 0.86, 0.90, and 0.88, respectively, and the area was 0.87 for detecting liver fibrosis in individuals with significant steatosis. Discussion/Conclusions: Ultrasound sample entropy imaging enables the identification of time-series patterns in RF signals received from the liver. The algorithmic scheme proposed in this study is compatible with general ultrasound pulse-echo systems, allowing clinical fibrosis risk evaluations of individuals with developing hepatic steatosis.- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 9, 1-12
Open AccessUltrasound Sample Entropy Imaging: A New Approach for Evaluating Hepatic Steatosis and Fibrosis
Objective: Hepatic steatosis causes nonalcoholic fatty liver disease and may progress to fibrosis. Ultrasound is the first-line approach to examining hepatic steatosis. Fatty droplets in the liver parenchyma alter ultrasound radiofrequency (RF) signal statistical properties. This study proposes using sample entropy, a measure of irregularity in time-series data determined by the dimension$m$ and tolerance$r$ , for ultrasound parametric imaging of hepatic steatosis and fibrosis. Methods: Liver donors and patients were enrolled, and their hepatic fat fraction (HFF) ($n =72$ ), steatosis grade ($n =286$ ), and fibrosis score ($n =65$ ) were measured to verify the results of sample entropy imaging using sliding-window processing of ultrasound RF data. Results: The sample entropy calculated using$m =$ 4 and$r =0.1$ was highly correlated with the HFF when a small window with a side length of one pulse was used. The areas under the receiver operating characteristic curve for detecting hepatic steatosis that was$\ge $ mild,$\ge $ moderate, and$\ge $ severe were 0.86, 0.90, and 0.88, respectively, and the area was 0.87 for detecting liver fibrosis in individuals with significant steatosis. Discussion/Conclusions: Ultrasound sample entropy imaging enables the identification of time-series patterns in RF signals received from the liver. The algorithmic scheme proposed in this study is compatible with general ultrasound pulse-echo systems, allowing clinical fibrosis risk evaluations of individuals with developing hepatic steatosis. - 26 October 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (7) , 1699-1711
Quantitative Assessment of Lung Ultrasound Grayscale Images Based on Shannon Entropy for the Detection of Pulmonary Aeration
Objective: Lung ultrasound (LUS) is a radiation‐free, affordable, and bedside monitoring method that can detect changes in pulmonary aeration before hypoxic damage. However, visual scoring methods of LUS only enable subjective diagnosis. Therefore, quantitative analysis of LUS is necessary for obtaining objective information on pulmonary aeration. Because raw data are not always available in conventional ultrasound systems, Shannon entropy (ShanEn) of information theory without the requirement of raw data is valuable. In this study, we explored the feasibility of ShanEn estimated through grayscale histogram (GSH) analysis of LUS images for the quantification of pulmonary aeration.Methods: Different degrees of pulmonary aeration caused by edema was induced in 32 male New Zealand rabbits intravenously injected with 0.1 mL/kg saline (the control group) and 0.025, 0.05, and 0.1 mL/kg oleic acid (mild, moderate, and severe groups, respectively). In vivo grayscale LUS images were acquired using a commercial point‐of‐care ultrasound system for estimation of GSH and corresponding ShanEn. Both lungs of each rabbit were dissected, weighed, and dried to determine the wet weight‐to‐dry weight ratio (W/D) through gravimetry.Results: The determination coefficients of linear correlations between ShanEn and W/D increased from 0.0487 to 0.7477 with gain and dynamic range (DR). In contrast to visual scoring methods of pulmonary aeration that use median gain and low DR, ShanEn for quantifying pulmonary aeration requires high gain and DR.Conclusion: The current findings indicate that ShanEn estimated through GSH analysis of LUS images acquired using conventional ultrasonic imaging systems has great potential to provide objective information on pulmonary aeration.
- 26 October 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (7) , 1699-1711
Quantitative Assessment of Lung Ultrasound Grayscale Images Based on Shannon Entropy for the Detection of Pulmonary Aeration
Objective: Lung ultrasound (LUS) is a radiation‐free, affordable, and bedside monitoring method that can detect changes in pulmonary aeration before hypoxic damage. However, visual scoring methods of LUS only enable subjective diagnosis. Therefore, quantitative analysis of LUS is necessary for obtaining objective information on pulmonary aeration. Because raw data are not always available in conventional ultrasound systems, Shannon entropy (ShanEn) of information theory without the requirement of raw data is valuable. In this study, we explored the feasibility of ShanEn estimated through grayscale histogram (GSH) analysis of LUS images for the quantification of pulmonary aeration.Methods: Different degrees of pulmonary aeration caused by edema was induced in 32 male New Zealand rabbits intravenously injected with 0.1 mL/kg saline (the control group) and 0.025, 0.05, and 0.1 mL/kg oleic acid (mild, moderate, and severe groups, respectively). In vivo grayscale LUS images were acquired using a commercial point‐of‐care ultrasound system for estimation of GSH and corresponding ShanEn. Both lungs of each rabbit were dissected, weighed, and dried to determine the wet weight‐to‐dry weight ratio (W/D) through gravimetry.Results: The determination coefficients of linear correlations between ShanEn and W/D increased from 0.0487 to 0.7477 with gain and dynamic range (DR). In contrast to visual scoring methods of pulmonary aeration that use median gain and low DR, ShanEn for quantifying pulmonary aeration requires high gain and DR.Conclusion: The current findings indicate that ShanEn estimated through GSH analysis of LUS images acquired using conventional ultrasonic imaging systems has great potential to provide objective information on pulmonary aeration.
- Open Access
- 4 August 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (8) , 557
Ultrasound Assessment of Hepatic Steatosis by Using the Double Nakagami Distribution: A Feasibility Study
Ultrasound imaging is a first-line assessment tool for hepatic steatosis. Properties of tissue microstructures correlate with the statistical distribution of ultrasound backscattered signals, which can be described by the Nakagami distribution (a widely adopted approximation of backscattered statistics). The double Nakagami distribution (DND) model, which combines two Nakagami distributions, was recently proposed for using high-frequency ultrasound to analyze backscattered statistics corresponding to lipid droplets in the fat-infiltrated liver. This study evaluated the clinical feasibility of the DND model in ultrasound parametric imaging of hepatic steatosis by conducting clinical experiments using low-frequency ultrasound dedicated to general abdominal examinations. A total of 204 patients were recruited, and ultrasound image raw data were acquired using a 3.5 MHz array transducer for DND parametric imaging using the sliding window technique. The DND parameters were compared with hepatic steatosis grades identified histologically. A receiver operating characteristic (ROC) curve analysis was used to evaluate the diagnostic performance. The results indicated that DND parametric imaging constructed using a sliding window with the side length of five times the pulse length of the transducer provided stable and reliable DND parameter estimations and visualized changes in the backscattered statistics caused by hepatic steatosis. The DND parameter increased with the hepatic steatosis grade. The areas under the ROC curve for identifying hepatic steatosis were 0.76 (≥mild), 0.81 (≥moderate), and 0.82 (≥severe). When using low-frequency ultrasound, DND imaging allows the clinical detection of hepatic steatosis and reflects information associated with lipid droplets in the fat-infiltrated liver.
- 4 August 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (8) , 557
Open AccessUltrasound Assessment of Hepatic Steatosis by Using the Double Nakagami Distribution: A Feasibility Study
Ultrasound imaging is a first-line assessment tool for hepatic steatosis. Properties of tissue microstructures correlate with the statistical distribution of ultrasound backscattered signals, which can be described by the Nakagami distribution (a widely adopted approximation of backscattered statistics). The double Nakagami distribution (DND) model, which combines two Nakagami distributions, was recently proposed for using high-frequency ultrasound to analyze backscattered statistics corresponding to lipid droplets in the fat-infiltrated liver. This study evaluated the clinical feasibility of the DND model in ultrasound parametric imaging of hepatic steatosis by conducting clinical experiments using low-frequency ultrasound dedicated to general abdominal examinations. A total of 204 patients were recruited, and ultrasound image raw data were acquired using a 3.5 MHz array transducer for DND parametric imaging using the sliding window technique. The DND parameters were compared with hepatic steatosis grades identified histologically. A receiver operating characteristic (ROC) curve analysis was used to evaluate the diagnostic performance. The results indicated that DND parametric imaging constructed using a sliding window with the side length of five times the pulse length of the transducer provided stable and reliable DND parameter estimations and visualized changes in the backscattered statistics caused by hepatic steatosis. The DND parameter increased with the hepatic steatosis grade. The areas under the ROC curve for identifying hepatic steatosis were 0.76 (≥mild), 0.81 (≥moderate), and 0.82 (≥severe). When using low-frequency ultrasound, DND imaging allows the clinical detection of hepatic steatosis and reflects information associated with lipid droplets in the fat-infiltrated liver.
- Open Access
Performance Evaluations on Using Entropy of Ultrasound Log-Compressed Envelope Images for Hepatic Steatosis Assessment: An In Vivo Animal Study
Ultrasound B-mode imaging based on log-compressed envelope data has been widely applied to examine hepatic steatosis. Modeling raw backscattered signals returned from the liver parenchyma by using statistical distributions can provide additional information to assist in hepatic steatosis diagnosis. Since raw data are not always available in modern ultrasound systems, information entropy, which is a widely known nonmodel-based approach, may allow ultrasound backscattering analysis using B-scan for assessing hepatic steatosis. In this study, we explored the feasibility of using ultrasound entropy imaging constructed using log-compressed backscattered envelopes for assessing hepatic steatosis. Different stages of hepatic steatosis were induced in male Wistar rats fed with a methionine- and choline-deficient diet for 0 (i.e., normal control) and 1, 1.5, and 2 weeks (n = 48; 12 rats in each group). In vivo scanning of rat livers was performed using a commercial ultrasound machine (Model 3000, Terason, Burlington, MA, USA) equipped with a 7-MHz linear array transducer (Model 10L5, Terason) for ultrasound B-mode and entropy imaging based on uncompressed (HE image) and log-compressed envelopes (HB image), which were subsequently compared with histopathological examinations. Receiver operating characteristic (ROC) curve analysis and areas under the ROC curves (AUC) were used to assess diagnostic performance levels. The results showed that ultrasound entropy imaging can be used to assess hepatic steatosis. The AUCs obtained from HE imaging for diagnosing different steatosis stages were 0.93 (≥mild), 0.89 (≥moderate), and 0.89 (≥severe), respectively. HB imaging produced AUCs ranging from 0.74 (≥mild) to 0.84 (≥severe) as long as a higher number of bins was used to reconstruct the signal histogram for estimating entropy. The results indicated that entropy use enables ultrasound parametric imaging based on log-compressed envelope signals with great potential for diagnosing hepatic steatosis.
Open AccessPerformance Evaluations on Using Entropy of Ultrasound Log-Compressed Envelope Images for Hepatic Steatosis Assessment: An In Vivo Animal Study
Ultrasound B-mode imaging based on log-compressed envelope data has been widely applied to examine hepatic steatosis. Modeling raw backscattered signals returned from the liver parenchyma by using statistical distributions can provide additional information to assist in hepatic steatosis diagnosis. Since raw data are not always available in modern ultrasound systems, information entropy, which is a widely known nonmodel-based approach, may allow ultrasound backscattering analysis using B-scan for assessing hepatic steatosis. In this study, we explored the feasibility of using ultrasound entropy imaging constructed using log-compressed backscattered envelopes for assessing hepatic steatosis. Different stages of hepatic steatosis were induced in male Wistar rats fed with a methionine- and choline-deficient diet for 0 (i.e., normal control) and 1, 1.5, and 2 weeks (n = 48; 12 rats in each group). In vivo scanning of rat livers was performed using a commercial ultrasound machine (Model 3000, Terason, Burlington, MA, USA) equipped with a 7-MHz linear array transducer (Model 10L5, Terason) for ultrasound B-mode and entropy imaging based on uncompressed (HE image) and log-compressed envelopes (HB image), which were subsequently compared with histopathological examinations. Receiver operating characteristic (ROC) curve analysis and areas under the ROC curves (AUC) were used to assess diagnostic performance levels. The results showed that ultrasound entropy imaging can be used to assess hepatic steatosis. The AUCs obtained from HE imaging for diagnosing different steatosis stages were 0.93 (≥mild), 0.89 (≥moderate), and 0.89 (≥severe), respectively. HB imaging produced AUCs ranging from 0.74 (≥mild) to 0.84 (≥severe) as long as a higher number of bins was used to reconstruct the signal histogram for estimating entropy. The results indicated that entropy use enables ultrasound parametric imaging based on log-compressed envelope signals with great potential for diagnosing hepatic steatosis.
- Open Access
- 1 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-9
Discrimination between Newly Formed and Aged Thrombi Using Empirical Mode Decomposition of Ultrasound B-Scan Image
Ultrasound imaging is a first-line diagnostic method for screening the thrombus. During thrombus aging, the proportion of red blood cells (RBCs) in the thrombus decreases and therefore the signal intensity of B-scan can be used to detect the thrombus age. To avoid the effect of system gain on the measurements, this study proposed using the empirical mode decomposition (EMD) of ultrasound image as a strategy to classify newly formed and aged thrombi. Porcine blood samples were used for thein vitroinduction of fresh and aged thrombi (at hematocrits of 40%). Each thrombus was imaged using an ultrasound scanner at different gains (15, 20, and 30 dB). Then, EMD of ultrasound signals was performed to obtain the first and second intrinsic mode functions (IMFs), which were further used to calculate the IMF-based echogenicity ratio (IER). The results showed that the performance of using signal amplitude of B-scan to reflect the thrombus age depends on gain. However, the IER is less affected by the gain in discriminating between fresh and aged thrombi. In the future, ultrasound B-scan combined with the EMD may be used to identify the thrombus age for the establishment of thrombolytic treatment planning.
- 1 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-9
Open AccessDiscrimination between Newly Formed and Aged Thrombi Using Empirical Mode Decomposition of Ultrasound B-Scan Image
Ultrasound imaging is a first-line diagnostic method for screening the thrombus. During thrombus aging, the proportion of red blood cells (RBCs) in the thrombus decreases and therefore the signal intensity of B-scan can be used to detect the thrombus age. To avoid the effect of system gain on the measurements, this study proposed using the empirical mode decomposition (EMD) of ultrasound image as a strategy to classify newly formed and aged thrombi. Porcine blood samples were used for thein vitroinduction of fresh and aged thrombi (at hematocrits of 40%). Each thrombus was imaged using an ultrasound scanner at different gains (15, 20, and 30 dB). Then, EMD of ultrasound signals was performed to obtain the first and second intrinsic mode functions (IMFs), which were further used to calculate the IMF-based echogenicity ratio (IER). The results showed that the performance of using signal amplitude of B-scan to reflect the thrombus age depends on gain. However, the IER is less affected by the gain in discriminating between fresh and aged thrombi. In the future, ultrasound B-scan combined with the EMD may be used to identify the thrombus age for the establishment of thrombolytic treatment planning.