Manju Henry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Manju Henry has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Peter G. Huggard
STFC Rutherford Appleton Laboratory, RAL Space, Didcot, U.K.
3 shared publications - Hui Wang
STFC Rutherford Appleton Laboratory, RAL Space, Didcot, U.K.
2 shared publications - Michael J. Lancaster
Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Birmingham B15 2TT, U.K.
2 shared publications Raymond Dickie
2 shared publications- Xiaobang Shang
National Physical Laboratory, Teddington, U.K.
2 shared publications - Bo Liu
James Watt School of Engineering, University of Glasgow, Glasgow, U.K.
1 shared publication
Latest Publications
- Open Access
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (4) , 446-454
A 290–310 GHz Single Sideband Mixer With Integrated Waveguide Filters
A 290-310 GHz Schottky diode based sub-harmonic mixer with integrated, low loss, impedance matching waveguide cavity filters is presented in this paper. This mixer was designed for use in a 300 GHz communication system with a 20 GHz intermediate frequency (IF) band centred at 15 GHz. Image rejection of the 260-280 GHz lower sideband (LSB), as well as impedance matching, was achieved using an integrated 3rd order filter in the RF waveguide. The conventional coupling matrix was used to design the filter even though the impedance presented to the RF port was complex and frequency dependent. The mixer was measured to have: (1) Single sideband (SSB) conversion loss of 9-10 dB across the upper sideband (USB), with a mixer noise temperature of 2000-2600 K. (2) A return loss at the RF port better than 12 dB, with three filter reflection zeroes (poles) distinguishable. (3) A sideband rejection ratio (SBR) from 13 to 25 dB, demonstrating the RF filter's excellent performance in terms of impedance matching and filtering.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (4) , 446-454
Open AccessA 290–310 GHz Single Sideband Mixer With Integrated Waveguide Filters
A 290-310 GHz Schottky diode based sub-harmonic mixer with integrated, low loss, impedance matching waveguide cavity filters is presented in this paper. This mixer was designed for use in a 300 GHz communication system with a 20 GHz intermediate frequency (IF) band centred at 15 GHz. Image rejection of the 260-280 GHz lower sideband (LSB), as well as impedance matching, was achieved using an integrated 3rd order filter in the RF waveguide. The conventional coupling matrix was used to design the filter even though the impedance presented to the RF port was complex and frequency dependent. The mixer was measured to have: (1) Single sideband (SSB) conversion loss of 9-10 dB across the upper sideband (USB), with a mixer noise temperature of 2000-2600 K. (2) A return loss at the RF port better than 12 dB, with three filter reflection zeroes (poles) distinguishable. (3) A sideband rejection ratio (SBR) from 13 to 25 dB, demonstrating the RF filter's excellent performance in terms of impedance matching and filtering.
- Open Access
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 100-107
WR-3 Waveguide Bandpass Filters Fabricated Using High Precision CNC Machining and SU-8 Photoresist Technology
This paper presents two WR-3 band (220–325 GHz) filters, one fabricated in metal using high precision computer numerically controlled milling and the other made with metallized SU-8 photoresist technology. Both are based on three coupled resonators, and are designed for a 287.3–295.9-GHz passband, and a 30-dB rejection between 317.7 and 325.9 GHz. The first filter is an extracted pole filter coupled by irises, and is precision milled using the split-block approach. The second filter is composed of three silver-coated SU-8 layers, each 432 μm thick. The filter structures are specially chosen to take advantage of the fabrication processes. When fabrication tolerances are accounted for, very good agreement between measurements and simulations are obtained, with median passband insertion losses of 0.41 and 0.45 dB for the metal and SU-8 devices, respectively. These two filters are potential replacements of frequency selective surface filters used in heterodyne radiometers for unwanted sideband rejection.
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 100-107
Open AccessWR-3 Waveguide Bandpass Filters Fabricated Using High Precision CNC Machining and SU-8 Photoresist Technology
This paper presents two WR-3 band (220–325 GHz) filters, one fabricated in metal using high precision computer numerically controlled milling and the other made with metallized SU-8 photoresist technology. Both are based on three coupled resonators, and are designed for a 287.3–295.9-GHz passband, and a 30-dB rejection between 317.7 and 325.9 GHz. The first filter is an extracted pole filter coupled by irises, and is precision milled using the split-block approach. The second filter is composed of three silver-coated SU-8 layers, each 432 μm thick. The filter structures are specially chosen to take advantage of the fabrication processes. When fabrication tolerances are accounted for, very good agreement between measurements and simulations are obtained, with median passband insertion losses of 0.41 and 0.45 dB for the metal and SU-8 devices, respectively. These two filters are potential replacements of frequency selective surface filters used in heterodyne radiometers for unwanted sideband rejection.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Inter-laboratory comparison of reflection and transmission measurements in WR-06 waveguide (110 GHz to 170 GHz)
This paper describes an exercise that was undertaken recently to compare reflection and transmission measurements in rectangular metallic waveguide from 110 GHz to 170 GHz (i.e. in the WR-06 waveguide size). The comparison involved making measurements on four devices fitted with `precision' MIL-DTL-3922-67D style flanges. These devices were circulated amongst the nine organizations that chose to participate in the exercise. The comparison took place between August 2008 and September 2009. Results from the exercise are presented in graphical form along with a statistical summary showing average variability for the measurements. The authors believe this is the first time that such a comparison of measurements has been made at these frequencies. These results therefore provide a benchmark for the current state-of-the-art for measurements made in waveguide at these frequencies.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Inter-laboratory comparison of reflection and transmission measurements in WR-06 waveguide (110 GHz to 170 GHz)
This paper describes an exercise that was undertaken recently to compare reflection and transmission measurements in rectangular metallic waveguide from 110 GHz to 170 GHz (i.e. in the WR-06 waveguide size). The comparison involved making measurements on four devices fitted with `precision' MIL-DTL-3922-67D style flanges. These devices were circulated amongst the nine organizations that chose to participate in the exercise. The comparison took place between August 2008 and September 2009. Results from the exercise are presented in graphical form along with a statistical summary showing average variability for the measurements. The authors believe this is the first time that such a comparison of measurements has been made at these frequencies. These results therefore provide a benchmark for the current state-of-the-art for measurements made in waveguide at these frequencies.