Allart M. Venema
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Allart M. Venema has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Anthony R. Absalom
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
3 shared publications- Anthony Ray Absalom
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications - Ana Catarina Queiroga
EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal
2 shared publications - David Szpilman
Sociedade Brasileira de Salvamento Aquático, Rio de Janeiro, Brazil
2 shared publications J. K. Götz Wietasch
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
2 shared publicationsMarko M. Sahinovic
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
2 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by Springer Nature in Acta Neurochirurgica
Postoperative pain following epidural local anaesthetic bolus administration after lumbar fusion: a retrospective analysis
Background: Postoperative pain remains a serious concern after posterior lumbar interbody fusion (PLIF). Intraoperative epidural boluses of local anaesthetics (LA) have been proposed to reduce postoperative pain, but evidence is inconsistent. This study evaluated the association between an epidural bolus and pain in the post-anaesthesia care unit (PACU) following PLIF. Methods: A retrospective study was conducted including 147 PLIF patients. Patients were divided into the bolus ( n = 80) or control group ( n = 67) based on whether an epidural LA bolus was administered at the end of surgery. Primary outcomes: static (in rest) and dynamic (in movement) pain intensity (Numeric Rating Scale, NRS) in the PACU. Secondary outcomes: ward NRS, opioid consumption (Morphine Milligram Equivalents, MME), PACU and hospital length of stay (LOS), and analgesia- and surgery-related complications within 1 month. The multivariable regression models were adjusted for age, sex, BMI, ASA classification, preoperative opioid use, previous spinal surgery, and screw trajectory. Results: The groups were similar in age and sex, but differed in BMI, ASA classification, prior spinal surgery, and screw trajectory. Primary outcome : No significant differences were observed in static (Mann–Whitney U = 2439.0, p = 0.60) or dynamic (Mann–Whitney U = 1944.5, p = 0.48) NRS in the PACU. After adjustments, both static (MD -0.28, 95% CI -1.42 to 0.87, p = 0.63) and dynamic NRS (MD -0.51, 95% CI -1.69 to 0.67, p = 0.39) remained similar. Secondary outcomes : Ward NRS and opioid consumption in the PACU did not differ, but MME/hour on postoperative day 1 was lower in the bolus group (MD -0.34, 95% CI -0.57 to -0.11, p = 0.004). PACU LOS, hospital LOS, and analgesia-related complications were similar. Surgery-related complications < 1 month were not increased in the bolus group. Conclusions: This retrospective study found no association between epidural LA bolus administration and lower postoperative pain or opioid consumption in the PACU after PLIF. However, secondary analyses suggested lower opioid consumption on postoperative day 1.
- 4 November 2026
- Published by Springer Nature in Acta Neurochirurgica
Open AccessPostoperative pain following epidural local anaesthetic bolus administration after lumbar fusion: a retrospective analysis
Background: Postoperative pain remains a serious concern after posterior lumbar interbody fusion (PLIF). Intraoperative epidural boluses of local anaesthetics (LA) have been proposed to reduce postoperative pain, but evidence is inconsistent. This study evaluated the association between an epidural bolus and pain in the post-anaesthesia care unit (PACU) following PLIF. Methods: A retrospective study was conducted including 147 PLIF patients. Patients were divided into the bolus ( n = 80) or control group ( n = 67) based on whether an epidural LA bolus was administered at the end of surgery. Primary outcomes: static (in rest) and dynamic (in movement) pain intensity (Numeric Rating Scale, NRS) in the PACU. Secondary outcomes: ward NRS, opioid consumption (Morphine Milligram Equivalents, MME), PACU and hospital length of stay (LOS), and analgesia- and surgery-related complications within 1 month. The multivariable regression models were adjusted for age, sex, BMI, ASA classification, preoperative opioid use, previous spinal surgery, and screw trajectory. Results: The groups were similar in age and sex, but differed in BMI, ASA classification, prior spinal surgery, and screw trajectory. Primary outcome : No significant differences were observed in static (Mann–Whitney U = 2439.0, p = 0.60) or dynamic (Mann–Whitney U = 1944.5, p = 0.48) NRS in the PACU. After adjustments, both static (MD -0.28, 95% CI -1.42 to 0.87, p = 0.63) and dynamic NRS (MD -0.51, 95% CI -1.69 to 0.67, p = 0.39) remained similar. Secondary outcomes : Ward NRS and opioid consumption in the PACU did not differ, but MME/hour on postoperative day 1 was lower in the bolus group (MD -0.34, 95% CI -0.57 to -0.11, p = 0.004). PACU LOS, hospital LOS, and analgesia-related complications were similar. Surgery-related complications < 1 month were not increased in the bolus group. Conclusions: This retrospective study found no association between epidural LA bolus administration and lower postoperative pain or opioid consumption in the PACU after PLIF. However, secondary analyses suggested lower opioid consumption on postoperative day 1.
- 17 October 2023
- Published by University of Groningen Press
Towards uniform reporting of drowning
- Open Access
- 9 June 2023
- Published by Frontiers Media SA in Frontiers in Disaster and Emergency Medicine
- Vol. 1, 1200857
Surviving the storm: manual vs. mechanical chest compressions onboard a lifeboat during bad weather conditions
Objective: It is challenging for rescuers to perform cardiopulmonary resuscitation (CPR) onboard lifeboats, particularly during rough weather. A mechanical chest compression device (MCD) may provide better quality chest compressions. The aim of this study was to compare the quality of chest compressions performed by lifeboat-crewmembers with those of a MCD during rough-sea conditions.Methods: Lifeboat-crewmembers were scheduled to provide compression-only CPR on a resuscitation-mannequin during two sets of five 6-min epochs on a lifeboat at sea in two different weather-conditions. Simultaneously a MCD was used for compression-only CPR on another mannequin onboard the lifeboat. On a third occasion compressions by MCD only were measured due to COVID-19 restrictions. The primary outcome variable was the quality of chest compression, evaluated using published variables and standards (mean compression depth and compression frequency, percentage correct compression depth, percentage of not leaning on the thorax, percentage of correct hand placement on the thorax, hands-off-time).Results: Six male lifeboat-crewmembers (mean age 35 years) performed CPR during two different weather conditions. In weather-conditions one (wind ~6–7 Beaufort/wave-height: 100–150 cm) quality of manual compressions was significantly worse than mechanical compressions for mean compression depth (p < 0.05) and compression frequency (p < 0.05), percentage correct compression depth (p < 0.05), percentage of not leaning on the thorax (p < 0.05), and hands off time (p < 0.05). Crewmembers could only perform CPR for a limited time-period (sea-conditions/seasickness) and after one set of five epochs measurements were halted. In weather-condition two (wind ~9 Beaufort/wave-height ~200 cm) similar results were found during two epochs, after which measurements were halted (sea-conditions/seasickness). In weather-condition three (wind ~7 Beaufort/wave-height ~300–400 cm) MCD compressions were according to resuscitation-guidelines except for three epochs during which the MCD was displaced.Conclusion: Crewmembers were only able to perform chest-compressions for a limited time because of the weather-conditions. The MCD was able to provide good quality chest compressions during all but three epochs during the study period. More research is needed to determine whether MCD-use in real-life circumstances improves outcome. Inclusion of data on use of a MCD on lifeboats should be considered in future revisions of the USFD and resuscitation guidelines.
- 9 June 2023
- Published by Frontiers Media SA in Frontiers in Disaster and Emergency Medicine
- Vol. 1, 1200857
Open AccessSurviving the storm: manual vs. mechanical chest compressions onboard a lifeboat during bad weather conditions
Objective: It is challenging for rescuers to perform cardiopulmonary resuscitation (CPR) onboard lifeboats, particularly during rough weather. A mechanical chest compression device (MCD) may provide better quality chest compressions. The aim of this study was to compare the quality of chest compressions performed by lifeboat-crewmembers with those of a MCD during rough-sea conditions.Methods: Lifeboat-crewmembers were scheduled to provide compression-only CPR on a resuscitation-mannequin during two sets of five 6-min epochs on a lifeboat at sea in two different weather-conditions. Simultaneously a MCD was used for compression-only CPR on another mannequin onboard the lifeboat. On a third occasion compressions by MCD only were measured due to COVID-19 restrictions. The primary outcome variable was the quality of chest compression, evaluated using published variables and standards (mean compression depth and compression frequency, percentage correct compression depth, percentage of not leaning on the thorax, percentage of correct hand placement on the thorax, hands-off-time).Results: Six male lifeboat-crewmembers (mean age 35 years) performed CPR during two different weather conditions. In weather-conditions one (wind ~6–7 Beaufort/wave-height: 100–150 cm) quality of manual compressions was significantly worse than mechanical compressions for mean compression depth (p < 0.05) and compression frequency (p < 0.05), percentage correct compression depth (p < 0.05), percentage of not leaning on the thorax (p < 0.05), and hands off time (p < 0.05). Crewmembers could only perform CPR for a limited time-period (sea-conditions/seasickness) and after one set of five epochs measurements were halted. In weather-condition two (wind ~9 Beaufort/wave-height ~200 cm) similar results were found during two epochs, after which measurements were halted (sea-conditions/seasickness). In weather-condition three (wind ~7 Beaufort/wave-height ~300–400 cm) MCD compressions were according to resuscitation-guidelines except for three epochs during which the MCD was displaced.Conclusion: Crewmembers were only able to perform chest-compressions for a limited time because of the weather-conditions. The MCD was able to provide good quality chest compressions during all but three epochs during the study period. More research is needed to determine whether MCD-use in real-life circumstances improves outcome. Inclusion of data on use of a MCD on lifeboats should be considered in future revisions of the USFD and resuscitation guidelines.
- Open Access
- 6 July 2021
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 9
Performance of Basic Life Support by Lifeboat Crewmembers While Wearing a Survival Suit and Life Vest: A Randomized Controlled Trial
Introduction: Crewmembers of the “Royal Netherlands Sea Rescue Institution” (KNRM) lifeboats must wear heavy survival suits with integrated lifejackets. This and the challenging environment onboard (boat movements, limited space) might influence Basic Life Support (BLS) performance. The primary objective of this study was to assess the impact of the protective gear on single-rescuer BLS-quality.Material and Methods: Sixty-five active KNRM crewmembers who had recently undergone a BLS-refresher course were randomized to wear either their protective gear (n = 32) or their civilian clothes (n = 33; control group) and performed five 2-min sessions of single rescuer BLS on a mannequin on dry land. BLS-quality was assessed according to Dutch and European Resuscitation guidelines. A between group analysis (Mann-Whitney U) and a repeated within group analysis of both groups (Friedman test) were performed.Results: There were no major demographic differences between the groups. The protective gear did not significant impair BLS-quality. It was also not associated with a significant increase in the perceived exertion of BLS (Borg's Rating scale). Compression depth, compression frequency, the percentage of correct compression depth and of not leaning on the thorax, and ventilation volumes in both groups were suboptimal when evaluated according to the BLS-guidelines.Conclusions: The protective gear worn by KNRM lifeboat-crewmembers does not have a significant influence on BLS-quality under controlled study conditions. The impact and significance on outcome in real life situations needs to be studied further. This study provides valuable input for optimizing the BLS-skills of lifeboat crewmembers.
- 6 July 2021
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 9
Open AccessPerformance of Basic Life Support by Lifeboat Crewmembers While Wearing a Survival Suit and Life Vest: A Randomized Controlled Trial
Introduction: Crewmembers of the “Royal Netherlands Sea Rescue Institution” (KNRM) lifeboats must wear heavy survival suits with integrated lifejackets. This and the challenging environment onboard (boat movements, limited space) might influence Basic Life Support (BLS) performance. The primary objective of this study was to assess the impact of the protective gear on single-rescuer BLS-quality.Material and Methods: Sixty-five active KNRM crewmembers who had recently undergone a BLS-refresher course were randomized to wear either their protective gear (n = 32) or their civilian clothes (n = 33; control group) and performed five 2-min sessions of single rescuer BLS on a mannequin on dry land. BLS-quality was assessed according to Dutch and European Resuscitation guidelines. A between group analysis (Mann-Whitney U) and a repeated within group analysis of both groups (Friedman test) were performed.Results: There were no major demographic differences between the groups. The protective gear did not significant impair BLS-quality. It was also not associated with a significant increase in the perceived exertion of BLS (Borg's Rating scale). Compression depth, compression frequency, the percentage of correct compression depth and of not leaning on the thorax, and ventilation volumes in both groups were suboptimal when evaluated according to the BLS-guidelines.Conclusions: The protective gear worn by KNRM lifeboat-crewmembers does not have a significant influence on BLS-quality under controlled study conditions. The impact and significance on outcome in real life situations needs to be studied further. This study provides valuable input for optimizing the BLS-skills of lifeboat crewmembers.
- 9 June 2021
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 127 (2) , 181-184
Perioperative glucocorticoid supplementation for patients undergoing endoscopic transsphenoidal pituitary tumour surgery: using a sledgehammer to crack a nut?
- 9 June 2021
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 127 (2) , 181-184
Perioperative glucocorticoid supplementation for patients undergoing endoscopic transsphenoidal pituitary tumour surgery: using a sledgehammer to crack a nut?
- Open Access
- 1 March 2021
- Published by Elsevier in Resuscitation Plus
- Vol. 5, 100072
Drowning and aquatic injuries dictionary
- 1 March 2021
- Published by Elsevier in Resuscitation Plus
- Vol. 5, 100072
Open AccessDrowning and aquatic injuries dictionary
- 1 March 2019
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 122 (3) , 300-304
Land of confusion: anaesthetic management during thrombectomy for acute ischaemic stroke
- 1 March 2019
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 122 (3) , 300-304
Land of confusion: anaesthetic management during thrombectomy for acute ischaemic stroke
- Open Access
- 22 March 2018
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 26 (1) , 1-11
Review of 14 drowning publications based on the Utstein style for drowning
The Utstein style for drowning (USFD) was published in 2003 with the aim of improving drowning research. To support a revision of the USFD, the current study aimed to generate an inventory of the use of the USFD parameters and compare the findings of the publications that have used the USFD. A search in Pubmed, Embase, the Cochrane Library, Web of Science and Scopus was performed to identify studies that used the USFD and were published between 01-10-2003 and 22-03-2015. We also searched in Pubmed, Embase, the Cochrane Library, Web of Science, and Scopus for all publications that cited the two publications containing the original ILCOR advisory statement introducing and recommending the USFD. In total we identified 14 publications by groups that explicitly used elements of the USFD for collecting and reporting their data. Of the 22 core and 19 supplemental USFD parameters, 6–19 core (27–86%) and 1–12 (5–63%) supplemental parameters were used; two parameters (5%) have not been used in any publication. Associations with outcome were reported for nine core (41%) and five supplemental (26%) USFD parameters. The USFD publications also identified non-USFD parameters related to outcome: initial cardiac rhythm, time points and intervals during resuscitation, intubation at the drowning scene, first hospital core temperature, serum glucose and potassium, the use of inotropic/vasoactive agents and the Paediatric Index of Mortality 2-score. Fourteen USFD based drowning publications have been identified. These publications provide valuable information about the process and quality of drowning resuscitation and confirm that the USFD is helpful for a structured comparison of the outcome of drowning resuscitation.
- 22 March 2018
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 26 (1) , 1-11
Open AccessReview of 14 drowning publications based on the Utstein style for drowning
The Utstein style for drowning (USFD) was published in 2003 with the aim of improving drowning research. To support a revision of the USFD, the current study aimed to generate an inventory of the use of the USFD parameters and compare the findings of the publications that have used the USFD. A search in Pubmed, Embase, the Cochrane Library, Web of Science and Scopus was performed to identify studies that used the USFD and were published between 01-10-2003 and 22-03-2015. We also searched in Pubmed, Embase, the Cochrane Library, Web of Science, and Scopus for all publications that cited the two publications containing the original ILCOR advisory statement introducing and recommending the USFD. In total we identified 14 publications by groups that explicitly used elements of the USFD for collecting and reporting their data. Of the 22 core and 19 supplemental USFD parameters, 6–19 core (27–86%) and 1–12 (5–63%) supplemental parameters were used; two parameters (5%) have not been used in any publication. Associations with outcome were reported for nine core (41%) and five supplemental (26%) USFD parameters. The USFD publications also identified non-USFD parameters related to outcome: initial cardiac rhythm, time points and intervals during resuscitation, intubation at the drowning scene, first hospital core temperature, serum glucose and potassium, the use of inotropic/vasoactive agents and the Paediatric Index of Mortality 2-score. Fourteen USFD based drowning publications have been identified. These publications provide valuable information about the process and quality of drowning resuscitation and confirm that the USFD is helpful for a structured comparison of the outcome of drowning resuscitation.
- Open Access
- 25 July 2017
- Published by Elsevier in Resuscitation
- Vol. 122, e7-e8
Reply to letter: Neurocognitive and behavioral outcomes in a nearly drowned child with cardiac arrest and hypothermia resuscitated after 43 min of no flow-time: A case study
- 25 July 2017
- Published by Elsevier in Resuscitation
- Vol. 122, e7-e8
Open AccessReply to letter: Neurocognitive and behavioral outcomes in a nearly drowned child with cardiac arrest and hypothermia resuscitated after 43 min of no flow-time: A case study