Marco Cesare Prata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marco Cesare Prata has a total of 457 co-authors. Here are the top co-authors by number of shared publications:
- Massimo Rossella
INFN Sezione di Pavia
7 shared publications - Alessandro Menegolli
INFN Sezione di Pavia
6 shared publications - Carlo de Vecchi
INFN Sezione di Pavia
4 shared publications - Riccardo Rossini
INFN Sezione di Pavia
4 shared publications - Gianluca L. Raselli
Istituto Nazionale di Fisica Nucleare Sezione di Pavia
3 shared publications - Massimiliano Clemenza
Milano-Bicocca Division, National Institute of Nuclear Physics (INFN), Piazza della Scienza 3, 20126 Milano, Italy
3 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1117
Probing dark matter interactions with a RES–NOVA prototype cryogenic detector
We report on the operation of a 13 g PbWO $$_4$$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO $$_4$$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES–NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES–NOVA detection concept, validating the use of archaeological Pb-based PbWO $$_4$$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES–NOVA detectors employing larger target masses and advanced thermal readout technologies.- 28 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1117
Open AccessProbing dark matter interactions with a RES–NOVA prototype cryogenic detector
We report on the operation of a 13 g PbWO $$_4$$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO $$_4$$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES–NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES–NOVA detection concept, validating the use of archaeological Pb-based PbWO $$_4$$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES–NOVA detectors employing larger target masses and advanced thermal readout technologies. - Open Access
- 27 July 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (7) , 243
Neutrino NSI in archaeological Pb
A bstract: Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO 4 crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton·yr, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar ν interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to 0 . 5 keV and 0 . 2 keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, ε ee , ε ττ , and ε eτ . A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton·yr.
- 27 July 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (7) , 243
Open AccessNeutrino NSI in archaeological Pb
A bstract: Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO 4 crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton·yr, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar ν interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to 0 . 5 keV and 0 . 2 keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, ε ee , ε ττ , and ε eτ . A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton·yr.
- Open Access
- 31 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
A muon beam monitor for the CHNet-MAXI experiment at the RIKEN-RAL laboratory
- 31 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessA muon beam monitor for the CHNet-MAXI experiment at the RIKEN-RAL laboratory
- 26 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
A cryogenic system for measuring in the VUV range the absolute quantum efficiency of light detectors with large sensitive area
- 26 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
A cryogenic system for measuring in the VUV range the absolute quantum efficiency of light detectors with large sensitive area
- Open Access
- 17 November 2023
- Published by MDPI AG in Condensed Matter
- Vol. 8 (4) , 99
Improving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout
LaBr:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 round LaBr:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good energy resolution and a fast time response to detect low-energy X-rays around 100 keV. A natural application was found inside the FAMU experiment, at RIKEN RAL. Its aim is a precise measurement of the proton Zemach radius with impinging muons, to contribute to the solution to the so-called “proton radius puzzle”. Signals to be detected are characteristic X-rays around 130 KeV. A limit for this type of detector, as compared to the ones with a photomultiplier readout, is its poorer timing characteristics due to the large capacity of the SiPM arrays used. In particular, long signal falltimes are a problem in experiments such as FAMU, where a “prompt” background component must be separated from a “delayed” one (after 600 ns) in the signal X-rays to be detected. Dedicated studies were pursued to improve the timing characteristics of the used detectors, starting from hybrid ganging of SiPM cells; then developing a suitable zero pole circuit with a parallel ganging, where an increased overvoltage for the SiPM array was used to compensate for the signal decrease; and finally designing ad hoc electronics to split the 1 detector’s SiPM array into four quadrants, thus reducing the involved capacitances. The aim was to improve the detectors’ timing characteristics, especially falltime, while keeping a good FWHM energy resolution for low-energy X-ray detection.- 17 November 2023
- Published by MDPI AG in Condensed Matter
- Vol. 8 (4) , 99
Open AccessImproving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout
LaBr:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 round LaBr:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good energy resolution and a fast time response to detect low-energy X-rays around 100 keV. A natural application was found inside the FAMU experiment, at RIKEN RAL. Its aim is a precise measurement of the proton Zemach radius with impinging muons, to contribute to the solution to the so-called “proton radius puzzle”. Signals to be detected are characteristic X-rays around 130 KeV. A limit for this type of detector, as compared to the ones with a photomultiplier readout, is its poorer timing characteristics due to the large capacity of the SiPM arrays used. In particular, long signal falltimes are a problem in experiments such as FAMU, where a “prompt” background component must be separated from a “delayed” one (after 600 ns) in the signal X-rays to be detected. Dedicated studies were pursued to improve the timing characteristics of the used detectors, starting from hybrid ganging of SiPM cells; then developing a suitable zero pole circuit with a parallel ganging, where an increased overvoltage for the SiPM array was used to compensate for the signal decrease; and finally designing ad hoc electronics to split the 1 detector’s SiPM array into four quadrants, thus reducing the involved capacitances. The aim was to improve the detectors’ timing characteristics, especially falltime, while keeping a good FWHM energy resolution for low-energy X-ray detection. - Open Access
- 1 April 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (04) , C04024
A comparison between scintillation light Analog and Digital Trigger for large volume Liquid Argon Time Projection Chambers
Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetectors, like photomultiplier tubes or silicon photomultipliers. Each method presents advantages and drawbacks, so the implementation of a hybrid solution can benefit from both approaches. To this purpose, an innovative electronic board prototype has been designed and proposed for the use in large volume LAr-TPC detectors.
- 1 April 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (04) , C04024
Open AccessA comparison between scintillation light Analog and Digital Trigger for large volume Liquid Argon Time Projection Chambers
Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetectors, like photomultiplier tubes or silicon photomultipliers. Each method presents advantages and drawbacks, so the implementation of a hybrid solution can benefit from both approaches. To this purpose, an innovative electronic board prototype has been designed and proposed for the use in large volume LAr-TPC detectors.
- 3 May 2019
- Published by Springer Nature
- p. 109-117
Predicting Diabetic Foot Maturing Through Evolutionary Computation
- 3 May 2019
- Published by Springer Nature
- p. 109-117
Predicting Diabetic Foot Maturing Through Evolutionary Computation
- Open Access
- 1 October 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (10) , P10030
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
- 1 October 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (10) , P10030
Open AccessTest and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
- Open Access
- 1 June 2009
- Published by Elsevier in Biological Psychiatry
- Vol. 65 (12) , 1123-1135
Author Index to Volume 65
- 1 June 2009
- Published by Elsevier in Biological Psychiatry
- Vol. 65 (12) , 1123-1135
Open AccessAuthor Index to Volume 65