David Howell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Howell has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- David W. Messinger
Rochester Institute of Technology
2 shared publications - Di Bai
Rochester Institute of Technology
2 shared publications - Andrew Beeby
Department of Chemistry, Durham University, Durham DH1 3LE, UK
1 shared publication - Catherine Emma Nicholson
School of Geography and Natural Sciences, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK
1 shared publication Delbert R. Wigfall
Department of Pathology, Johns Hopkins Medical Institutions, Baltimore, MD
1 shared publication- Fred Sanfilippo
Emory University
1 shared publication
Latest Publications
- 21 February 2021
- Published by Springer Nature
- p. 200-214
Deep Learning Spatial-Spectral Processing of Hyperspectral Images for Pigment Mapping of Cultural Heritage Artifacts
- 21 February 2021
- Published by Springer Nature
- p. 200-214
Deep Learning Spatial-Spectral Processing of Hyperspectral Images for Pigment Mapping of Cultural Heritage Artifacts
- 7 March 2019
- Published by Taylor & Francis in Journal of the American Institute for Conservation
- Vol. 58 (1-2) , 69-89
A hyperspectral imaging spectral unmixing and classification approach to pigment mapping in the Gough & Selden Maps
In this research, a spectral unmixing and classification approach for hyperspectral imagery (HSI) of historical artifacts is introduced. The Gram Matrix and Max-D techniques have been used to estimate the within material diversity in an HSI and extract the spectra of the class exemplars, called endmembers. Due to the absence of ground truth, the exemplar spectra are assumed to represent pure materials in the scene or unique pigment mixtures. After extracting endmembers, the Nonnegative Linear Least Squares algorithm and the K-means algorithm are then used to classify the HSI based on the endmembers. We also proposed a “spectral angle spatial patterns” method to map the class membership and goodness across the map to identify per-class spatial patterns. This approach has been successfully utilized in two historical artifacts, the Gough Map of Britain (c.1400) and the Selden Map of China (c.1619). Both maps were imaged using a hyperspectral imaging system while in the collection at the Bodleian Library, Oxford University. It reveals at least six kinds of dominant water pigments used in each map along with their spatial distribution. This approach can be generalized to a novel pigment mapping tool for historical geographers to analyze the material diversity of historical artifacts.
- 7 March 2019
- Published by Taylor & Francis in Journal of the American Institute for Conservation
- Vol. 58 (1-2) , 69-89
A hyperspectral imaging spectral unmixing and classification approach to pigment mapping in the Gough & Selden Maps
In this research, a spectral unmixing and classification approach for hyperspectral imagery (HSI) of historical artifacts is introduced. The Gram Matrix and Max-D techniques have been used to estimate the within material diversity in an HSI and extract the spectra of the class exemplars, called endmembers. Due to the absence of ground truth, the exemplar spectra are assumed to represent pure materials in the scene or unique pigment mixtures. After extracting endmembers, the Nonnegative Linear Least Squares algorithm and the K-means algorithm are then used to classify the HSI based on the endmembers. We also proposed a “spectral angle spatial patterns” method to map the class membership and goodness across the map to identify per-class spatial patterns. This approach has been successfully utilized in two historical artifacts, the Gough Map of Britain (c.1400) and the Selden Map of China (c.1619). Both maps were imaged using a hyperspectral imaging system while in the collection at the Bodleian Library, Oxford University. It reveals at least six kinds of dominant water pigments used in each map along with their spatial distribution. This approach can be generalized to a novel pigment mapping tool for historical geographers to analyze the material diversity of historical artifacts.
- Open Access
- 6 July 2018
- Published by Springer Nature in Heritage Science
- Vol. 6 (1) , 42
Comparing the effectiveness of hyperspectral imaging and Raman spectroscopy: a case study on Armenian manuscripts
There is great practical and scholarly interest in the identification of pigments in works of art. This paper compares the effectiveness of the widely used Raman Spectroscopy (RS), with hyperspectral imaging (HSI), a reflectance imaging technique, to evaluate the reliability of HSI for the identification of pigments in historic works of art and to ascertain if there are any benefits from using HSI or a combination of both. We undertook a case study based on six Armenian illuminated manuscripts (eleventh–eighteenth centuries CE) in the Bodleian Library, University of Oxford. RS, and HSI (380–1000 nm) were both used to analyse the same 10 folios, with the data then used to test the accuracy and efficiency of HSI against the known results from RS using reflectance spectra reference databases compiled by us for the project. HSI over the wavelength range 380–1000 nm agreed with RS at best 93% of the time, and performance was enhanced using the SFF algorithm and by using a database with many similarities to the articles under analysis. HSI is significantly quicker at scanning large areas, and can be used alongside RS to identify and map large areas of pigment more efficiently than RS alone. HSI therefore has potential for improving the speed of pigment identification across manuscript folios and artwork but must be used in conjunction with a technique such as RS.
- 6 July 2018
- Published by Springer Nature in Heritage Science
- Vol. 6 (1) , 42
Open AccessComparing the effectiveness of hyperspectral imaging and Raman spectroscopy: a case study on Armenian manuscripts
There is great practical and scholarly interest in the identification of pigments in works of art. This paper compares the effectiveness of the widely used Raman Spectroscopy (RS), with hyperspectral imaging (HSI), a reflectance imaging technique, to evaluate the reliability of HSI for the identification of pigments in historic works of art and to ascertain if there are any benefits from using HSI or a combination of both. We undertook a case study based on six Armenian illuminated manuscripts (eleventh–eighteenth centuries CE) in the Bodleian Library, University of Oxford. RS, and HSI (380–1000 nm) were both used to analyse the same 10 folios, with the data then used to test the accuracy and efficiency of HSI against the known results from RS using reflectance spectra reference databases compiled by us for the project. HSI over the wavelength range 380–1000 nm agreed with RS at best 93% of the time, and performance was enhanced using the SFF algorithm and by using a database with many similarities to the articles under analysis. HSI is significantly quicker at scanning large areas, and can be used alongside RS to identify and map large areas of pigment more efficiently than RS alone. HSI therefore has potential for improving the speed of pigment identification across manuscript folios and artwork but must be used in conjunction with a technique such as RS.
- 2 January 2018
- Published by Taylor & Francis in Journal of the Institute of Conservation
- Vol. 41 (1) , 85-89
Jonathan Ashley-Smith: mentor, role model, inspiration
(2018). Jonathan Ashley-Smith: mentor, role model, inspiration. Journal of the Institute of Conservation: Vol. 41, A Festschrift for Jonathan Ashley-Smith, pp. 85-89.
- 2 January 2018
- Published by Taylor & Francis in Journal of the Institute of Conservation
- Vol. 41 (1) , 85-89
Jonathan Ashley-Smith: mentor, role model, inspiration
(2018). Jonathan Ashley-Smith: mentor, role model, inspiration. Journal of the Institute of Conservation: Vol. 41, A Festschrift for Jonathan Ashley-Smith, pp. 85-89.
- Open Access
- 19 September 2017
- Published by Taylor & Francis in Journal of the Institute of Conservation
- Vol. 41 (2) , 142-153
There’s more to reflectance spectroscopy than lux
Fibre-optic reflectance spectroscopy is widely used as a tool for the analysis of coloured materials such as pigments and paints. We describe a new design for a FORS probe which is held some 5cm away from the sample surface and interrogates a spot of 2mm diameter, offering a significant advantage over existing methods. The spectrometer employs an illuminance of 1250lux, equivalent to 0.5mWcm−2 averaged across the visible spectrum. The spectral measurements take less than a second ensuring that the risk of sample photodegradation is minimal. Under these conditions there is no detectable temperature rise of the illuminated area. Increasing the illuminance above 25mWcm−2, a light level significantly higher than that required for our measurements, gave rise to significant localised temperature rises in model manuscripts. This demonstrates the need for caution when using this technique for the analysis of precious heritage items. RésuméLa spectroscopie de réflectance à fibre optique est largement utilisée comme outil d’analyse des matériaux colorés tels que les pigments et les peintures. Nous décrivons une nouvelle conception d’une sonde FORS qui est tenue à environ 5cm de la surface de l’échantillon et interroge une tache de 2mm de diamètre, offrant un avantage significatif par rapport aux méthodes existantes. Le spectromètre utilise un éclairement de 1250lux, équivalent à 0,5mWcm−2 en moyenne dans le spectre visible. Les mesures spectrales nécessitent moins d’une seconde, ce qui garantit que le risque de photodégradation de l‘échantillon est minime. Dans ces conditions, il n’y a pas d’élévation de température détectable de la zone éclairée. L’augmentation de l’éclairement au-dessus de 25mWcm−2, un niveau de lumière significativement supérieur à celui requis pour nos mesures, a donné lieu à des augmentations de température localisées significatives dans les manuscrits modèles. Ceci démontre la nécessaire prudence lors de l’utilis... ZusammenfassungFaseroptische Reflektionsspektroskopie (FORS) ist weit verbreitet als ein Werkzeug in der Analyse von farbigem Material wie Pigmenten und Farben. Wir beschreiben eine neue Methode, in der ein FORS Sensor etwa 5cm von der Probenoberfläche entfernt gehalten wird und dabei einen Punkt von 2mm Durchmesser untersucht. Dies bietet große Vorteile im Vergleich zu herkömmlichen Methoden. Das Spektrometer nutzt einen Beleuchtungsstärke von 1250lux, äquivalent zu 0.5mWcm−2 gemittelt über das sichtbare Spektrum. Die Messungen brauchen weniger als eine Sekunde und das Risiko der Photodegradation der Probe ist minimal. Unter diesen Konditionen kann in dem beleuchteten Bereich keine Temperaturerhöhung festgestellt werden. Wenn die Beleuchtungsstärke auf über 25mWcm−2 erhöht wird, ein Lichtwert, der weit über dem liegt, der für unsere Messungen benötigt wird, liegt, dann konnten auf Modellhandschriften signifikante, lokale Temperaturerhöhungen festgestellt werden. Dies unterstreicht die Notwendigkeit Vorsi... ResumenLa espectroscopia refractaria de fibra óptica se utilizada mucho como instrumento de análisis de materiales de color como pigmentos y pinturas. Describimos un nuevo diseño de sonda FORS que se mantiene a unos 5cm de distancia de la superficie de la muestra y analiza una zona de 2mm de diámetro, ofreciendo una ventaja significativa sobre los métodos existentes. El espectrómetro emplea una iluminancia de 1250lux, promediada de todo el espectro visible, equivalente a 0,5mWcm−2. El riesgo de foto-degradación de la muestra es mínimo ya que las mediciones espectrales llevan menos de un segundo. Bajo estas condiciones no se detecta aumento de temperatura en el área iluminada. El aumento de la iluminancia por encima de 25mWcm−2, un nivel de luz significativamente más alto que el requerido para nuestras mediciones, causó considerables aumentos de temperatura localizados en los manuscritos modelo. Esta investigación demuestra la necesidad de usar esta técnica con precaución en el análisis de piezas valiosas ... 摘要反射光谱学之于照度的优势光纤反射光谱技术广泛应用于有色材料(颜料和油漆等)分析。我们将介绍 FORS 探头的一个新设计——它与样品表面保持约 5cm 的距离,探测点直径为 2mm,这与现有其他方法相比具有显著优势。 光谱仪采用 1250 勒克斯的照度,相当于整个可见光谱平均值为 0.5mWcm−2 。 光谱测量时间不到一秒钟,这使样品光降解的风险降到最小。 在这些条件下,照明区域没有明显的温度升高。若我们将照度提高到 25mWcm−2 以上(明显高于测量所需的光照水平),便会导致样本手稿局部升温显著。这说明在对珍贵遗产文物使用这种分析技术时需要我们格外谨慎。
- 19 September 2017
- Published by Taylor & Francis in Journal of the Institute of Conservation
- Vol. 41 (2) , 142-153
Open AccessThere’s more to reflectance spectroscopy than lux
Fibre-optic reflectance spectroscopy is widely used as a tool for the analysis of coloured materials such as pigments and paints. We describe a new design for a FORS probe which is held some 5cm away from the sample surface and interrogates a spot of 2mm diameter, offering a significant advantage over existing methods. The spectrometer employs an illuminance of 1250lux, equivalent to 0.5mWcm−2 averaged across the visible spectrum. The spectral measurements take less than a second ensuring that the risk of sample photodegradation is minimal. Under these conditions there is no detectable temperature rise of the illuminated area. Increasing the illuminance above 25mWcm−2, a light level significantly higher than that required for our measurements, gave rise to significant localised temperature rises in model manuscripts. This demonstrates the need for caution when using this technique for the analysis of precious heritage items. RésuméLa spectroscopie de réflectance à fibre optique est largement utilisée comme outil d’analyse des matériaux colorés tels que les pigments et les peintures. Nous décrivons une nouvelle conception d’une sonde FORS qui est tenue à environ 5cm de la surface de l’échantillon et interroge une tache de 2mm de diamètre, offrant un avantage significatif par rapport aux méthodes existantes. Le spectromètre utilise un éclairement de 1250lux, équivalent à 0,5mWcm−2 en moyenne dans le spectre visible. Les mesures spectrales nécessitent moins d’une seconde, ce qui garantit que le risque de photodégradation de l‘échantillon est minime. Dans ces conditions, il n’y a pas d’élévation de température détectable de la zone éclairée. L’augmentation de l’éclairement au-dessus de 25mWcm−2, un niveau de lumière significativement supérieur à celui requis pour nos mesures, a donné lieu à des augmentations de température localisées significatives dans les manuscrits modèles. Ceci démontre la nécessaire prudence lors de l’utilis... ZusammenfassungFaseroptische Reflektionsspektroskopie (FORS) ist weit verbreitet als ein Werkzeug in der Analyse von farbigem Material wie Pigmenten und Farben. Wir beschreiben eine neue Methode, in der ein FORS Sensor etwa 5cm von der Probenoberfläche entfernt gehalten wird und dabei einen Punkt von 2mm Durchmesser untersucht. Dies bietet große Vorteile im Vergleich zu herkömmlichen Methoden. Das Spektrometer nutzt einen Beleuchtungsstärke von 1250lux, äquivalent zu 0.5mWcm−2 gemittelt über das sichtbare Spektrum. Die Messungen brauchen weniger als eine Sekunde und das Risiko der Photodegradation der Probe ist minimal. Unter diesen Konditionen kann in dem beleuchteten Bereich keine Temperaturerhöhung festgestellt werden. Wenn die Beleuchtungsstärke auf über 25mWcm−2 erhöht wird, ein Lichtwert, der weit über dem liegt, der für unsere Messungen benötigt wird, liegt, dann konnten auf Modellhandschriften signifikante, lokale Temperaturerhöhungen festgestellt werden. Dies unterstreicht die Notwendigkeit Vorsi... ResumenLa espectroscopia refractaria de fibra óptica se utilizada mucho como instrumento de análisis de materiales de color como pigmentos y pinturas. Describimos un nuevo diseño de sonda FORS que se mantiene a unos 5cm de distancia de la superficie de la muestra y analiza una zona de 2mm de diámetro, ofreciendo una ventaja significativa sobre los métodos existentes. El espectrómetro emplea una iluminancia de 1250lux, promediada de todo el espectro visible, equivalente a 0,5mWcm−2. El riesgo de foto-degradación de la muestra es mínimo ya que las mediciones espectrales llevan menos de un segundo. Bajo estas condiciones no se detecta aumento de temperatura en el área iluminada. El aumento de la iluminancia por encima de 25mWcm−2, un nivel de luz significativamente más alto que el requerido para nuestras mediciones, causó considerables aumentos de temperatura localizados en los manuscritos modelo. Esta investigación demuestra la necesidad de usar esta técnica con precaución en el análisis de piezas valiosas ... 摘要反射光谱学之于照度的优势光纤反射光谱技术广泛应用于有色材料(颜料和油漆等)分析。我们将介绍 FORS 探头的一个新设计——它与样品表面保持约 5cm 的距离,探测点直径为 2mm,这与现有其他方法相比具有显著优势。 光谱仪采用 1250 勒克斯的照度,相当于整个可见光谱平均值为 0.5mWcm−2 。 光谱测量时间不到一秒钟,这使样品光降解的风险降到最小。 在这些条件下,照明区域没有明显的温度升高。若我们将照度提高到 25mWcm−2 以上(明显高于测量所需的光照水平),便会导致样本手稿局部升温显著。这说明在对珍贵遗产文物使用这种分析技术时需要我们格外谨慎。
- 8 September 2017
- Published by Springer Nature
- p. 331-346
Revealing the Past: How Science Is Unlocking Cartographic Secrets
- 8 September 2017
- Published by Springer Nature
- p. 331-346
Revealing the Past: How Science Is Unlocking Cartographic Secrets
- Open Access
- 1 September 1995
- Published by Elsevier in American Journal of Kidney Diseases
- Vol. 26 (3) , 520-526
Identification of selective immunoglobulin a deficiency by renal biopsy
- 1 September 1995
- Published by Elsevier in American Journal of Kidney Diseases
- Vol. 26 (3) , 520-526
Open AccessIdentification of selective immunoglobulin a deficiency by renal biopsy