Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Izabela Naydenova has a total of 253 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    UV-induced degradation of photopolymerisable hybrid sol-gel materials for holographic applications

    by Luca Sorridente, Aaron Byrne, Izabela Naydenova, Tatsiana Mikulchyk, Kevin Murphy

    UV-induced degradation of photopolymerisable hybrid sol-gel layers sensitised with Omnirad 784 is investigated for holographic optical element applications. Volume phase transmission gratings were recorded in layers prepared under different curing conditions and with polyurethane diol as a plasticising additive. UV exposure was found to induce layer cracking, with layer thickness and curing temperature strongly affecting the degradation time. Lower curing temperatures and plasticiser incorporation extend the lifetime of layers from minutes to up to 2 years following exposure to a UV dose of 28.1 J / cm 2 , while preserving holographic recording capability. Nanoindentation measurements suggest that UV exposure promotes further network stiffening, consistent with additional post-exposure polymerisation and the associated build-up of internal stress leading to cracking. Results identify layer thickness, curing temperature and plasticiser incorporation as the key processing parameters governing UV-induced degradation, and provide practical strategies for improving the environmental stability of such holographic materials.

  • Open Access

    Modeling the copying accuracy of two-dimensional holographic gratings in photopolymer media

    by Maged Shaban, Dana Mackey, Owen Kearney, Izabela Naydenova

    Volume holographic gratings are periodic refractive index structures widely used in sensing and photonic devices. This paper develops a modeling and computational framework for predicting the copying accuracy of two-dimensional gratings recorded in photopolymer materials using interference lithography. A previous mathematical model is generalized to describe material transport, polymer growth, and modulation of the refractive index during exposure, enabling, for the first time, a quantitative assessment of copying accuracy in holographic gratings. High-fidelity finite-element simulations were performed for different optical lattices produced by three-beam interference. The results show that the diffusion–polymerization ratio has a strong impact on pattern accuracy, modulation depth, and polymer distribution. In particular, diffusion-dominated regimes enable high copying accuracy, while polymerization-dominated conditions lead to significant distortions of the recorded structure. Furthermore, the model predictions are experimentally validated by good agreement in the measured diffraction patterns and efficiencies.

  • Open Access

    Holographic recording on a curved substrate: investigation of a method to increase the numerical aperture in holographic optical lenses

    by Jorge Lasarte, Kevin Murphy, Izabela Naydenova, Jesús Atencia, Ma Victoria Collados, Suzanne Martin

    This study investigates methods to enhance the numerical aperture (NA) of holographic optical lenses (HOLs) through innovative holographic recording techniques. The research explores the limits of conventional holographic recording of high NA lenses and presents a novel curved-recording technique with the potential to go beyond these limits. The objective is to obtain high NA HOLs suitable for use with LED sources and other highly-diverging input beams. The work first outlines how the maximum numerical aperture lens achievable through holographic recording is limited by the recording geometry. Next, the effect of curving the substrate during holographic recording, and later returning it to a planar shape for use, is explored in order to demonstrate that this could provide a means of fabricating a higher numerical aperture lens. HOLs are then recorded experimentally, firstly using the standard approach for high NA; the overlap of two beams at a plane photosensitive film with as large a beam aperture as possible, and the focal point as close to the (planar) photopolymer as the geometry will allow. Then, a similar arrangement is used, but with curved photopolymer substrates. Diffraction angles and efficiencies of the resulting holographic lenses are compared with the theoretically predicted Bragg diffraction. HOLs with a 20 mm aperture and focal lengths as short as 12 mm are demonstrated.

  • Open Access

    Temperature dependence of the imaging properties of holographic lenses

    by Tomás Lloret, Jorge Lasarte, Suzanne Martin, Izabela Naydenova, Inmaculada Pascual

    The demand for advanced photonic technologies to enhance augmented reality (AR) devices has led to a significant interest in new optical materials suitable for operation in sometimes challenging environmental conditions, such as elevated temperatures levels. Holographic optical lenses (HOLs), fabricated using holographic recording, offer several advantages over traditional refractive lenses, including greater versatility, lower cost, lower weight, and increased adaptability. In this study, we investigated the optical and thermal performance of HOLs recorded on four different photosensitive materials: Bayfol HX200, Bayfol HX120, a PVA/acrylamide-based photopolymer (AA/PVA), and a photopolymerisable hybrid sol–gel (PHSG). The lenses were exposed to thermal cycles 20 ∘ C–100 ∘ C–20 ∘ C to simulate real-world conditions in AR systems, where heat generation from processors, sensors, displays, and the proximity to poweful LED light sources can affect their optical performance. The results highlight that Bayfol HX200 showed the highest thermal stability, while the PHSG demonstrated good recovery properties after thermal stress. Optical and image quality were evaluated using parameters such as root mean square wavefront error, Strehl ratio and spatial resolution, which revealed significant variations in lens performance as a function of temperature. These results provide valuable information on the material selection for durable, high-performance holographic lenses in AR applications.


  • Open Access

    Improvements in the thermal stability and mechanical robustness of holograms recorded in acrylamide/polyvinyl alcohol-based photopolymers through the use of D-Sorbitol as a plasticizer

    by Michael Murray, Aaron Byrne, Izabela Naydenova, Suzanne Martin

    In this work, a photopolymer formulation is presented that demonstrates significant improvements in layer hardness and temperature stability, while retaining the excellent holographic recording characteristics and ease of preparation associated with acrylamide (AA)/polyvinyl alcohol (PVA)-based photopolymers. This is achieved through the use of N-phenyl glycine as an electron donor and, for the first time, D-Sorbitol, a naturally occurring sugar-alcohol, as a plasticizer. The plasticizing effect of D-Sorbitol is demonstrated through the minimal loss of diffraction efficiency ( η ) observed upon UV bleaching (fixing) of 500 lines/mm gratings, which is evidence for effective mass transport during holographic recording. This solves a key challenge for holographic optical elements: balancing the need for the permeability that ensures diffusion during holographic recording, with the need for a permanent refractive index modulation in a hard, robust layer/coating. Gratings made in previous photopolymer formulations using NPG demonstrated improved hardness but were partially erased during the UV bleaching step. Plasticizers such as TEA and glycerol helped, but also caused a severe reduction in hardness. Here, we report holographic gratings made with 21 wt. % D-Sorbitol that demonstrates stability after prolonged exposure to a temperature of 95 °C and has a permanent RIM of 0.002. An increased indentation hardness was also observed in samples with D-Sorbitol compared to the TEA or glycerol, at the optimum concentration of 21 wt. % D-Sorbitol layers were measured to have more than three times higher hardness than the samples with glycerol or TEA. A similar trend was observed for the elastic modulus ( E ), which was found to be approximately 4 GPa for layers with 21 wt. % D-Sorbitol; one order of magnitude higher than the elastic modulus of samples prepared with glycerol or TEA.

  • Holographic Optical Elements for Application in Wound Healing Monitoring

    by Pamela Stoeva, Tatsiana Mikulchyk, Dervil Cody, Maria Antonietta Ferrara, Giuseppe Coppola, Suzanne Martin, Izabela Naydenova

  • Open Access

    Nanoimprinted Holographic MOF Diffraction Gratings─Advancing Selective Volatile Organic Compound Detection at Low Concentrations

    by Aleksandra Hernik, Masaya Sugihara, Ajay Padunnappattu, Norbert Stock, Rob Ameloot, Izabela Naydenova

    Metal–organic frameworks (MOFs) hold remarkable potential for detecting volatile organic compounds (VOCs) in applications ranging from indoor air quality monitoring to breath-based diagnostics. However, the integration of MOFs into optical sensors remains a significant challenge. In this study, we present an optimized soft lithographic approach for fabricating high-quality surface relief diffraction gratings composed entirely of MOF nanoparticles, as replicas of holographic structures. By increasing the height amplitude of the gratings, we significantly enhanced the sensitivity, as predicted by the Raman–Nath theory. For instance, a ZIF-71 grating with a depth of 530 nm demonstrated exceptional sensitivity to six VOCs, achieving a detection limit of 60 ppb for toluene. The general applicability of the approach was demonstrated by integrating other porous materials, resulting in an improved sensitivity to acetone. This work represents a step toward developing an optical VOC sensor array.


  • Holographic multi-waveguide system: towards implementation in wearable sensor technologies

    by Pamela Stoeva, Tatsiana Mikulchyk, Suzanne Martin, Maria Antonietta Ferrara, Giuseppe Coppola, Izabela Naydenova

    Holographic optical elements (HOEs) are integral to advancements in optical sensing, augmented reality, solar energy harvesting, biomedical diagnostics, and many other fields, offering precise and versatile light manipulation capabilities. This study, to the best of the authors’ knowledge, is the first to design and fabricate an HOE mutli-waveguide system using a thermally and environmentally stable photopolymerizable hybrid sol-gel (PHSG) for sensing applications. Using a 476.5 nm recording wavelength, 60% diffraction efficiency PHSG holographic waveguides of spatial frequency of 1720 lines/mm were successfully fabricated to function as in- and out-couplers at 632.8 nm and 700 nm wavelength, respectively. The waveguides were integrated into a polydimethylsiloxane (PDMS) microfluidic system, guiding excitation light of 632.8 nm wavelength into and extracting fluorescence light signal peaking at 700 nm from a location filled with methylene blue water solution. Further, to demonstrate the potential of the proposed optical system, four holographic waveguides were recorded by peristrophic and angular multiplexing in the same location of the material and the input beam was delivered into four spatially separated channels by total internal reflection in the sol-gel layer, thus, successfully highlighting the capabilities and advantages of HOE waveguides for parallel interrogation of multiple locations in a wearable sensor. This study demonstrates the efficiency and versatility of PHSG-based HOE waveguides, underscoring their potential to enhance photonic device design and performance across various optical applications.


  • Open Access

    Fabrication and characterization of holographic lenses recorded in photopolymers with high refractive index modulation for application in solar concentration

    by Brian Rogers, Paola Galli, Suzanne Martin, Andrea Bianco, Izabela Naydenova

    Holographic optical elements have a history of use in solar concentrating devices. One of the most significant challenges of using these elements in real-life devices is their typically high angular and spectral selectivity. A possible solution to expanding their operational range is using thinner devices, but to achieve high diffraction efficiency, a recording material with a high refractive index is required. In this work, a photopolymer with high refractive index modulation is used to create volume holographic lenses in layers as thin as 10 µm, while maintaining high diffraction efficiency. These lenses are designed for minimal angular selectivity, while still operating in the volume regime through modelling using the Kogelnik coupled wave theory. A theoretical analysis of the operation of the device as a volume holographic element was carried out. Once recorded, the full benefits of the low angular selectivity concentrating hologram are measured using a PV cell in a solar simulator and are compared with more angularly selective counterparts. An improvement of the PV cell performance of 44% is observed when coupling light with the thinner, less angularly selective lens.


  • Uniform surface patterning: a three-beam holographic approach

    by Owen Kearney, Izabela Naydenova

    With the increased risk of antibiotic-resistant pathogens, the development of point-of-care devices for their detection is essential. Surface patterns alongside surface functionalization are often employed to create an environment conducive to bacteria adhesion. We proposed surface relief patterns that are designed to have a dual role. Optically, they provide a diffracted light signal, and they also are expected to control the adhesion of the bacteria to the surface. The strength of the diffracted signal is expected to provide a quantitative measure of the number of bacterial cells attached to the patterned surface. In this article, we described the first step in the development and characterization of such surfaces. A three-beam holographic setup for patterning of a photopolymer surface was built. The optical system allows for the creation of surface relief cross-gratings (SRCGs) with unit cell sizes ranging from 8×8 μm2 (125 lines/mm) to 1×1 μm2 (1000 lines/mm). The surfaces are analyzed via atomic force microscopy, fast Fourier transform, and diffraction efficiency measurements. The SRCG relief amplitude dependence on recording parameters and photopolymer composition is investigated, and the results demonstrate a strong dependence of the SRCG height, area roughness, and diffraction efficiency on the SRCG feature period of the recorded structures. The largest surface relief amplitude achieved is 1.4 μm at an 8-μm period. Control over surface roughness by optical patterning was experimentally confirmed.