LMLawrence W. Miller

Lawrence W. Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lawrence W. Miller has a total of 122 co-authors. Here are the top co-authors by number of shared publications:

  • D. Rajasekhar Reddy

    Department of Chemistry, University of Illinois at Chicago, 845 West Taylor Street, Chicago, IL 60607 (USA)

    6 shared publications
  • Shabnam Mohandessi

    Department of Chemistry, University of Illinois at Chicago, Chicago, IL 60607, USA

    6 shared publications
  • Megha Rajendran

    Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois

    5 shared publications
  • Ha Pham

    Department of Chemistry, University of Illinois at Chicago, Chicago, USA

    4 shared publications
  • Harsha E. Rajapakse

    Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, USA

    4 shared publications
  • Marc A. Anderson

    4 shared publications

Latest Publications

  • Open Access

    Förster resonance energy transfer biosensors for fluorescence and time-gated luminescence analysis of rac1 activity

    by Ha Pham, Mona Hoseini Soflaee, Andrei V. Karginov, Lawrence W. Miller

    Genetically encoded, Förster resonance energy transfer (FRET) biosensors enable live-cell optical imaging of signaling molecules. Small conformational changes often limit the dynamic range of biosensors that combine fluorescent proteins (FPs) and sensing domains into a single polypeptide. To address this, we developed FRET and lanthanide-based FRET (LRET) biosensors of Rac1 activation with two key features that enhance sensitivity and dynamic range. For one, alpha helical linker domains separate FRET partners and ensure a large conformational change and FRET increase when activated Rac1 at the biosensor C-terminus interacts with an amino-terminal Rac binding domain. Incorporation of a luminescent Tb(III) complex with long (~ ms) excited state lifetime as a LRET donor enabled time-gated luminescence measurements of Rac1 activity in cell lysates. The LRET dynamic range increased with ER/K linker length up to 1100% and enabled robust detection of Rac1 inhibition in 96-well plates. The ER/K linkers had a less pronounced, but still significant, effect on conventional FRET biosensors (with FP donors and acceptors), and we were able to dynamically image Rac1 activation at cell edges using fluorescence microscopy. The results herein highlight the potential of FRET and LRET biosensors with ER/K linkers for cell-based imaging and screening of protein activities.


  • Open Access

    FRET and LRET Biosensors for Cell-based Imaging and Screening of Rac1 Activation

    by Ha Pham, Mona Hoseini Soflaee, Andrei V Karginov, Lawrence W. Miller

    Rac1 is a key regulator of several cell signaling pathways and dysregulated Rac1 activation has been implicated in cancer. Genetically encoded Förster resonance energy transfer (FRET) biosensors with enhanced dynamic range enabled live cell fluorescence imaging of Rac1 activity and a cell lysate-based assay of Rac1 inhibition in 96-well plates. We prepared HEK293 cell lines that stably expressed polypeptides with a general domain sequence ( N - to C -terminus) of 1) FRET acceptor; 2) Rac/Cdc42 binding domain of human p21 protein kinase A (residues 68-150); 3) a linker domain; 4) FRET donor; and 5) full-length Rac1. Activated Rac1 binds to the protein kinase A domain, bringing donors and acceptors close together to increase FRET. We evaluated the effects on FRET signal dynamic range of alpha helical linkers comprised of alternating repeats of roughly four glutamate and four arginine or lysine residues. So-called ER/K linkers had limited effects on conventional FRET biosensors that incorporated the fluorescent protein (FP) pairs mCerulean/YPet, or mTFP1(cp227)/mVenus(cp229). Fluorometric measurements of cells that co-expresssed biosensors with positive (TIAM1) or negative (RhoGDI) Rac1 regulators revealed significant dynamic range enhancement in only one FP construct (mCerulean/YPet with 20 nm ER/K linker) relative to an analogous structure that incorporated an unstructured linker. We transfected this construct into a cell line that stably expressed a rapamycin-inducible c-Src analog (RapR-Src) and observed activation of Rac1 at protruding edges following rapamycin stimulation. In cells that expressed lanthanide-based FRET (LRET biosensors) that incorporated a luminescent terbium complex donor and GFP fluorescent acceptor, time-gated luminescence (TGL) measurements showed substantial gains in dynamic range that increased with linker length (up to 1200%). We robustly detected small molecule Rac1 inhibition following lysis of LRET biosensor-expressing cells grown directly in 96-well plates. The results herein highlight the potential of FRET and LRET biosensors with ER/K linkers for cell-based imaging and screening of protein activities.

  • Open Access

    Single-chain lanthanide luminescence biosensors for cell-based imaging and screening of protein-protein interactions

    by Ting Chen, Ha T. Pham, Ali Mohamadi, Lawrence W. Miller

    Research tools that enable imaging or analysis of protein-protein interactions (PPIs) directly within living cells provide unique and valuable biological insights and can also aid drug discovery efforts. Here, we present lanthanide-based, Förster resonance energy transfer (lanthanide-based FRET, or LRET) biosensors for time-gated luminescence (TGL) imaging or multiwell plate analysis of PPIs. Polypeptide chains comprised of an alpha helical linker flanked by a Tb(III) complex, GFP and two binding domains exhibit large differences in long-lifetime, Tb(III)-to-GFP LRET-sensitized emission between open (unbound) and closed (bound) states. We used TGL microscopy to image ca. 500% increases in Tb(III)-to-GFP LRET following rapamycin addition to NIH 3T3 cells that expressed biosensors bearing FKBP12 and the rapamycin binding domain of m-Tor (FRB) at each terminus. Much larger signal changes, up to ca. 2500%, were observed when cells were grown in 96-well or 384-well plates and analyzed using a TGL plate reader. We also measured the interaction of p53 and HDM2 and its inhibition within intact HeLa cells grown in 96-well plates and estimated a z’-factor of 0.5 for the assay. The modular design and high dynamic range of Tb(III)-based LRET biosensors will facilitate versatile imaging and cell-based screening of PPIs.


  • Intracellular MLCK1 diversion reverses barrier loss to restore mucosal homeostasis

    by W. Vallen Graham, Weiqi He, Amanda M. Marchiando, Juanmin Zha, Gurminder Singh, Hua-Shan Li, Amlan Biswas, Ma. Lora Drizella M. Ong, Zhi-Hui Jiang, Wangsun Choi, et al.

    Epithelial barrier loss is a driver of intestinal and systemic diseases. Myosin light chain kinase (MLCK) is a key effector of barrier dysfunction and a potential therapeutic target, but enzymatic inhibition has unacceptable toxicity. Here, we show that a unique domain within the MLCK splice variant MLCK1 directs perijunctional actomyosin ring (PAMR) recruitment. Using the domain structure and multiple screens, we identify a domain-binding small molecule (divertin) that blocks MLCK1 recruitment without inhibiting enzymatic function. Divertin blocks acute, tumor necrosis factor (TNF)-induced MLCK1 recruitment as well as downstream myosin light chain (MLC) phosphorylation, barrier loss, and diarrhea in vitro and in vivo. Divertin corrects barrier dysfunction and prevents disease development and progression in experimental inflammatory bowel disease. Beyond applications of divertin in gastrointestinal disease, this general approach to enzymatic inhibition by preventing access to specific subcellular sites provides a new paradigm for safely and precisely targeting individual properties of enzymes with multiple functions.


  • Time-Gated Luminescence Detection of Enzymatically Produced Hydrogen Sulfide: Design, Synthesis, and Application of a Lanthanide-Based Probe

    by Yao Yao, Loruhama Delgado-Rivera, Hamid Samareh Afsari, Liang Yin, Gregory R. J. Thatcher, Terry W. Moore, Lawrence W. Miller

    Hydrogen sulfide (H2S) is now recognized as an important gaseous transmitter that is involved in a variety of biological processes. Here, we report the design and synthesis of a luminescent lanthanide biosensor for H2S, LP2-Cu(II)-Ln(III), a heterobinuclear metal complex that uses Cu(II) decomplexation to control millisecond-scale-lifetime-Tb(III)- or Eu(III)-emission intensity. LP2-Cu(II)-Ln(III) responded rapidly, selectively, and with high sensitivity to aqueous H2S. The probe’s potential for biological applications was verified by measuring the H2S generated by the slow-releasing chemical-sulfide-donor GYY4147, by cystathionine γ-lyase (CSE), and by Na2S-stimulated HeLa cells.


  • Time Gated Luminescence Imaging of Immunolabeled Human Tissues

    by Ting Chen, Rui Hong, Darren Magda, Christopher Bieniarz, Larry Morrison, Lawrence W. Miller

    Multiplexed immunofluorescence imaging of formalin-fixed, paraffin-embedded tissues is a powerful tool for investigating proteomic profiles and diagnosing disease. However, conventional immunofluorescence with organic dyes is limited in the number of colors that can be simultaneously visualized, is made less sensitive by tissue autofluorescence background, and is usually incompatible with commonly used hematoxylin and eosin staining. Herein, we demonstrate the comparative advantages of using time-gated luminescence microscopy in combination with an emissive Tb(III) complex, Lumi4-Tb, for tissue imaging in terms of sensitivity, multiplexing potential, and compatibility with common immunohistochemistry protocols. We show that time-gated detection of millisecond-scale Tb(III) emission increases signal-to-noise ratio relative to conventional steady-state detection of organic dye fluorescence and permits visualization of low-abundance tissue markers such as Bcl-6 or MSH-6. In addition, temporal separation of long- and short-lifetime (∼nanosecond) signals adds a second dimension for multiplexing and also permits detection of intermolecular Tb(III)-to-dye Förster resonance energy transfer. Furthermore, we demonstrate that the Lumi4-Tb complex is compatible with tyramide signal amplification and, unlike conventional organic dyes, can be reliably used on tissue stained with hematoxylin and eosin. Our results indicate that time-gated luminescence microscopy using Tb(III) labels can provide a sensitive and robust method to perform multiplexed immunofluorescence on archived or clinical tissue specimens.


  • Frontispiece: Time‐Gated Detection of Cystathionine γ‐Lyase Activity and Inhibition with a Selective, Luminogenic Hydrogen Sulfide Sensor

    by Yao Yao, Chen Kong, Liang Yin, Atul D. Jain, Kiira Ratia, Gregory R. J. Thatcher, Terry W. Moore, Tom G. Driver, Lawrence W. Miller