ASAlexander Schütz

Alexander Schütz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Schütz has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stepwise optimization of a Flexible Microtube Plasma (FµTP) as an ionization source for Ion Mobility Spectrometry

    by Carolin Drees, Alexander Schütz, Guanghui Niu, Joachim Franzke, Wolfgang Vautz, Sebastian Brandt


  • Detection of multiclass explosives and related compounds in soil and water by liquid chromatography-dielectric barrier discharge ionization-mass spectrometry

    by Bienvenida Gilbert-López, Felipe J. Lara-Ortega, José Robles-Molina, Sebastian Brandt, Alexander Schütz, David Moreno-González, Juan F. García-Reyes, Antonio Molina-Díaz, Joachim Franzke

    In this work, the multiclass detection of explosives and related compounds has been studied by liquid chromatography-high-resolution mass spectrometry by means of a time-of-flight mass spectrometer (TOFMS) operated in the negative ion mode, using dielectric barrier discharge ionization (DBDI). Reversed-phase high-performance liquid chromatography (HPLC) separation was performed using water–methanol mobile phase without any modifier, although the effect of ammonium acetate was studied. DBD plasma was generated by applying a square wave voltage of 2.5 kV to a 100-mL min−1 He flow. The DBDI probe was adjusted to fit the commercial API source housing so that the HPLC eluent was nebulized and vaporized in the same manner as for atmospheric-pressure chemical ionization (APCI). The ionization process was affected by the temperature of the two nitrogen streams used to vaporize the solvent and the analytes, particularly for RDX and HMX, which are thermolabile compounds. The best approach in terms of sensitivity for all the studied compounds was the use of a gradient of temperatures in the ionization source, starting at 225/200 °C (vaporizer/drying gas temp) for nitramines and ending at 350/325 °C for nitroaromatic compounds. High-resolution full-scan spectra of individual selected compounds were recorded by LC-DBDI-TOFMS, and the results were compared to LC-APCI-TOFMS. A better sensitivity (slope of calibration curve) was obtained by DBDI for more than 70% of the studied compounds in both wastewater and soil extracts.


  • Use of dielectric barrier discharge ionization to minimize matrix effects and expand coverage in pesticide residue analysis by liquid chromatography-mass spectrometry

    by Felipe J. Lara-Ortega, José Robles-Molina, Sebastian Brandt, Alexander Schütz, Bienvenida Gilbert-López, Antonio Molina-Díaz, Juan F. García-Reyes, Joachim Franzke


  • Flexible Microtube Plasma (FμTP) as an Embedded Ionization Source for a Microchip Mass Spectrometer Interface

    by Sebastian Brandt, Felix David Klute, Alexander Schütz, Ulrich Marggraf, Carolin Drees, Pascal Vogel, Wolfgang Vautz, Joachim Franzke

    Dielectric barrier discharges are used as soft ionization sources for mass spectrometers or ion mobility spectrometers, enabling excellent possibilities for analytical applications. A new robust and small-footprint discharge design, flexible microtube plasma (FμTP), developed as a result of ongoing miniaturization and electrode design processes, is presented in this work. This design provides major safety benefits by fitting the electrode into an inert flexible fused silica capillary (tube). Notably, in this context, the small discharge dimensions enable very low gas flows in the range of –1; portability; the use of hydrogen, nitrogen, and air in addition to noble gases such as helium and argon, including its mixtures with propane; and application in microchip environments. By coupling FμTP with gas chromatography/mass spectrometry, we show that the polarity principle of the new discharge design allows it to outperform established ionization sources such as dielectric barrier discharge for soft ionization (DBDI) and low-temperature plasma (LTP) at low concentrations of perfluoroalkanes in terms of sensitivity, ionization efficiency, chemical background, linear dynamic range, and limit of detection by a large margin. In negative ion mode, the limit of detection is improved by more than 3-fold compared with that of DBDI and by 8-fold compared with that of LTP. The protonation capability was evaluated by headspace measurements of diisopropyl methylphosphonate in positive ion mode, showing low fragmentation and high stability in comparison to DBDI and LTP.


  • Characterization of dielectric barrier discharges for analytical chemistry

    by Felix David Klute, Alexander Schütz, Sebastian Brandt, Sebastian Burhenn, Pascal Vogel, Joachim Franzke

    Dielectric barrier discharges (DBDs) are well-established and useful tools for scientific as well as industrial applications. They have been of high interest for analytical applications due to the fact that DBDs can produce small, low temperature/power, and atmospheric plasmas. These kind of plasmas can be applied for the detection and quantification of analytes in several ways: either, DBDs can be used for example as fragmentation and excitation sources to detect elements via optical emission spectrometry (OES), or as ionization sources of molecules for the detection via mass spectrometry (MS). ISAS has developed several of these discharges and studied the impact of the DBD itself on the subsequent application. This work summarizes the development from low pressure DBD implemented in diode laser atomic absorption spectrometry to atmospheric DBDs that can be used for different ambient applications such as the trace detection of arsenic species via OES or the soft ionization of molecular compounds via MS.


  • Screening of semifluorinated n‐alkanes by gas chromatography coupled to dielectric barrier discharge ionization mass spectrometry

    by Sebastian Hagenhoff, Ansgar Korf, Ullrich Markgraf, Sebastian Brandt, Alexander Schütz, Joachim Franzke, Heiko Hayen

    Rationale: The potential of an atmospheric pressure ionization source based on a dielectric barrier discharge in helium for the hyphenation of gas chromatography and mass spectrometry (GC/DBDI‐MS) has been demonstrated only recently and for a limited range of compounds. Due to its ‘soft’ ionization properties and the possibility to choose from a variety of atmospheric pressure ionization MS instruments, GC/DBDI‐MS has the potential to be an interesting alternative to ‘classic’ GC/MS techniques. Methods: The hyphenation of GC with DBDI‐MS at atmospheric pressure is used for the determination of semifluorinated n‐alkanes in ski wax samples. Results: Different to perfluorinated n‐alkanes, which are typically detected as [M − F + O] − and [M − F] − , semifluorinated n‐alkanes can be detected both in positive mode as [M − 3H + nO] + and [M − H + nO] + ( n = 0, 1, 2, and 3) ions, as well as in negative mode as a fragment ion representing the fluorinated part of the respective semifluorinated n‐alkane. The method allowed the sensitive detection of semifluorinated n‐alkanes with achievable limits of detection (LODs) in the single digit pg range injected on column. To examine the applicability of the GC/DBDI‐MS method, semifluorinated n‐alkanes were determined in fluorinated ski waxes. Results were confirmed by complimentary GC/electron ionization MS measurements. Conclusions: The unique SFA ionization patterns serve for complementary unambiguous identification of semifluorinated n‐alkane species in positive mode and screening of contained n‐alkanes fluorinated chain lengths in negative mode.


  • Soft Argon–Propane Dielectric Barrier Discharge Ionization

    by Alexander Schütz, Felipe J. Lara-Ortega, Felix David Klute, Sebastian Brandt, Michael Schilling, Antje Michels, Damir Veza, Vlasta Horvatic, Juan F. García-Reyes, Joachim Franzke

    Dielectric barrier discharges (DBDs) have been used as soft ionization sources (DBDI) for organic mass spectrometry (DBDI-MS) for approximately ten years. Helium-based DBDI is often used because of its good ionization efficiency, low ignition voltage and homogenous plasma conditions. Argon needs much higher ignition voltages than helium when the same discharge geometry is used. A filamentary plasma, which is not suitable for soft ionization, may be produced instead of a homogenous plasma. This difference results in N2, present in helium and argon as an impurity, being Penning-ionized by helium but not by metastable argon atoms. In this study, a mixture of argon and propane (C3H8) was used as an ignition aid to decrease the ignition and working voltages because propane can be Penning-ionized by argon metastables. This approach leads to homogenous argon-based DBDI. Furthermore, operating DBDI in an open environment assumes that many un-charged analyte molecules do not interact with the reactant ions. To overcome this disadvantage, we present a novel ap-proach where the analyte is introduced in an enclosed system through the discharge capillary itself. This non-ambient DBDI-MS arrangement is presented, characterized and could advance the novel connection of DBDI with analytical separation techniques such as gas chromatography (GC) and high-pressure liquid chromatography (HPLC) in the near future.


  • Dielectric barrier discharges applied for soft ionization and their mechanism

    by Sebastian Brandt, Felix David Klute, Alexander Schütz, Joachim Franzke


  • Open Access

    An experimental study on the influence of trace impurities on ionization of atmospheric noble gas dielectric barrier discharges

    by F. D. Klute, A. Schütz, A. Michels, C. Vadla, D. Veza, V. Horvatic, J. Franzke

    Penning Ionisation of N2+ by collisions with of N2 with HeM and [C3H8]+ by collisions of C3H8 with ArM.