PDPeter Roger Dunstan

Peter Roger Dunstan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Roger Dunstan has a total of 180 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A new method to triage colorectal cancer referrals in the UK using serum Raman spectroscopy and machine learning

    by Cerys A Jenkins, Susan Chandler, Rhys Jenkins, Kym Thorne, Freya Woods, Andrew Cunningham, Kayleigh Nelson, Rachel Still, Jenna Walters, Non Gywnne, et al.

    Suspected colorectal cancer (CRC) referrals based on non-specific symptoms currently lead to large numbers of patients being referred for invasive investigations and poor yield in cancer detection. Secondary care diagnostics, particularly endoscopy, struggle to meet the ever-increasing demand and patients face lengthy waits from the point of referral. Here we propose a blood test utilising high-throughput Raman spectroscopy and machine learning as an accurate triage tool. We present results from the first mixed methods clinical validation study of its kind, evaluating the ability of the test to perform in its target population of primary care patients, and its acceptability to those administering and receiving the test. The test was able to accurately rule out cancer with a negative predictive value of 98.0%. This performance could reduce the number of invasive diagnostic procedures in the cohort by at least 47%. Collectively, our findings promote a novel, non-invasive solution to triage CRC referrals with potential to reduce patient anxiety, accelerate access to treatment and improve outcomes.

  • A high-throughput serum Raman spectroscopy platform and methodology for colorectal cancer diagnostics

    by Cerys A. Jenkins, Rhys A. Jenkins, Meleri M. Pryse, Kathryn A. Welsby, Maki Jitsumura, Catherine A. Thornton, Peter R. Dunstan, Dean A. Harris

    Vibrational spectroscopic techniques such as Raman spectroscopy and Fourier transform infrared spectroscopy (FTIR) have huge potential for the analysis of biological specimens. The techniques allow the user to gain label-free, non-destructive biochemical information about a given sample. Previous studies using vibrational spectroscopy with the specific application of diagnosing colorectal diseases such as cancer have mainly focused on in vivo or in vitro studies of tissue specimens using microscopy or probe based techniques. There have been few studies of vibrational spectroscopic techniques based on the analysis of blood serum for the advancement of colorectal cancer diagnostics. With growing interest in the field of liquid biopsies, this study presents the development of a high-throughput (HT) serum Raman spectroscopy platform and methodology and compares dry and liquid data acquisition of serum samples. This work considers factors contributing to translatability of the methodologies such as HT design, inter-user variability and sample handling effects on diagnostic capability. The HT Raman methods were tested on a pilot dataset of serum from 30 cancer patients and 30 matched control patients using statistical analysis via cross-validated PLS-DA with a maximum achieved a sensitivity of 83% and specificity of 83% for detecting colorectal cancer.


  • Open Access

    Investigation into the effects of surface stripping ZnO nanosheets

    by Chris J Barnett, Georgina Jackson, Daniel R. Jones, Aled R. Lewis, Kathryn Welsby, Jon E Evans, James D. McGettrick, Trystan Watson, Thierry G G Maffeis, Peter R. Dunstan, et al.

    ZnO nanosheets are polycrystalline nanostructures that are used in devices including solar cells and gas sensors. However, for efficient and reproducible device operation and contact behaviour the conductivity characteristics must be controlled and surface contaminants removed. Here we use low doses of argon bombardment to remove surface contamination and make reproducible lower resistance contacts. Higher doses strip the surface of the nanosheets altering the contact type from near-ohmic to rectifying by removing the donor-type defects, which photoluminescence shows to be concentrated in the near-surface. Controlled doses of argon treatments allow nanosheets to be customised for device formation.


  • Multivariate spectral analysis of pH SERS probes for improved sensing capabilities

    by Adam Williams, Kevin John Flynn, Zhidao Xia, Peter Roger Dunstan

    Adsorption of functional groups to the surface of plasmonic nanoparticles provides a platform for localised optical sensing. Over the past decade, nanoscale sensors for intracellular pH measurement based on surface‐enhanced Raman spectroscopy (SERS) have been developed. However, the approaches by which pH‐SERS measurements are made and analysed can greatly impact the precision and accuracy of pH calibration. To improve pH nanosensors, the sources of experimental variation must be determined and the data must be optimally analysed. Here we report the plasmon‐induced decarboxylation of para‐mercaptobenzoic acid (pMBA) pH reporters attached to gold nanoparticles and conclude a strong association with laser power. The detrimental decarboxylation of pMBA has profound implications on the sensitivity and reliability of the pH sensor. Decarboxylation spectral signatures map directly onto those that are typically used to record pH changes, and, hence, the greatest implication of decarboxylation of pH sensors is inaccurate or false pH reporting. Here a more robust spectral analysis for pH sensing based upon an optimal spectral region for pH calibration is presented together with a unique application of the multivariate statistical technique, principal component analysis (PCA). PCA interprets complex spectral dynamics, and by direct comparisons with the typically employed ratiometric analysis, a significant improvement in generating accurate pH sensing is demonstrated. An application of these methods in determining the pH of internalised nanosensors in macrophage cells further promotes these step changes in pH measurement methodology via the avoidance of disruptive spectral signatures that arise in real applications. Copyright © 2016 John Wiley & Sons, Ltd.


  • Open Access

    Role of Raman spectroscopy and surface enhanced Raman spectroscopy in colorectal cancer

    by Cerys A Jenkins, Paul D Lewis, Peter R Dunstan, Dean A Harris

    Colorectal cancer (CRC) is the fourth most common cancer in the United Kingdom and is the second largest cause of cancer related death in the United Kingdom after lung cancer. Currently in the United Kingdom there is not a diagnostic test that has sufficient differentiation between patients with cancer and those without cancer so the current referral system relies on symptomatic presentation in a primary care setting. Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are forms of vibrational spectroscopy that offer a non-destructive method to gain molecular information about biological samples. The techniques offer a wide range of applications from in vivo or in vitro diagnostics using endoscopic probes, to the use of micro-spectrometers for analysis of biofluids. The techniques have the potential to detect molecular changes prior to any morphological changes occurring in the tissue and therefore could offer many possibilities to aid the detection of CRC. The purpose of this review is to look at the current state of diagnostic technology in the United Kingdom. The development of Raman spectroscopy and SERS in clinical applications relation for CRC will then be discussed. Finally, future areas of research of Raman/SERS as a clinical tool for the diagnosis of CRC are also discussed.


  • Generic epitaxial graphene biosensors for ultrasensitive detection of cancer risk biomarker

    by Z Tehrani, G Burwell, M A Mohd Azmi, A Castaing, R Rickman, J Almarashi, P Dunstan, A Miran Beigi, S H Doak, O J Guy


  • Properties of Electrodeposited CuSCN 2D Layers and Nanowires Influenced by Their Mixed Domain Structure

    by Dmitry Aldakov, Cyril Chappaz-Gillot, Raul Salazar, Vincent Delaye, Kathryn A. Welsby, Valentina Ivanova, Peter R. Dunstan


  • Enhancement of lattice defect signatures in graphene and ultrathin graphite using tip‐enhanced Raman spectroscopy

    by R. H. Rickman, P. R. Dunstan

    Understanding the role of defects in graphene is the key to tailoring the properties of graphene and promoting the development of graphene‐based devices. Defects can affect the electronic properties of a device while also offering a means by which to functionalize the local properties. Using tip‐enhanced Raman spectroscopy (TERS), heightened defect sensitivity was demonstrated on graphene edges, folds, and overlapping regions. Measurements confirm that TERS can provide simultaneous structural and spectral information on a localized scale, hence offering defect characterization on a scale that is not obtainable using conventional Raman spectroscopy. This study observed preferential enhancement of the D band signal on multilayered graphene and ultrathin graphite; in addition, other key defect signatures were also enhanced and detected. We present our findings in relation to theoretical predictions of graphene defect signatures and an analysis of the sensitivity of TERS in measuring two‐dimensional structures. Copyright © 2013 John Wiley & Sons, Ltd.


  • Open Access

    Quantum Dots for Multiplexed Detection and Characterisation of Prostate Cancer Cells Using a Scanning Near-Field Optical Microscope

    by Kelly-Ann D. Walker, Claire Morgan, Shareen H. Doak, Peter R. Dunstan

    In this study scanning near-field optical microscopy (SNOM) has been utilised in conjunction with quantum dot labelling to interrogate the biomolecular composition of cell membranes. The technique overcomes the limits of optical diffraction found in standard fluorescence microscopy and also yields vital topographic information. The technique has been applied to investigate cell-cell adhesion in human epithelial cells. This has been realised through immunofluorescence labelling of the cell-cell adhesion protein E-cadherin. Moreover, a dual labelling protocol has been optimised to facilitate a comparative study of the adhesion mechanisms and the effect of aberrant adhesion protein expression in both healthy and cancerous epithelial cells. This study reports clear differences in the morphology and phenotype of healthy and cancerous cells. In healthy prostate epithelial cells (PNT2), E-cadherin was predominantly located around the cell periphery and within filopodial extensions. The presence of E-cadherin appeared to be enhanced when cell-cell contact was established. In contrast, examination of metastatic prostate adenocarcinoma cells (PC-3) revealed no E-cadherin labelling around the periphery of the cells. This lack of functional E-cadherin in PC-3 cells coincided with a markedly different morphology and PC-3 cells were not found to form close cell-cell associations with their neighbours. We have demonstrated that with a fully optimised sample preparation methodology, multiplexed quantum dot labelling in conjunction with SNOM imaging can be successfully applied to interrogate biomolecular localisation within delicate cellular membranes.


  • Single-walled carbon nanotubes: differential genotoxic potential associated with physico-chemical properties

    by Bella B. Manshian, Gareth Js. Jenkins, Paul M. Williams, Chris Wright, Andrew R. Barron, Andrew P. Brown, Nicole Hondow, Peter R. Dunstan, Rob Rickman, Ken Brady, et al.

    Single-walled carbon nanotubes (SWCNTs) have recently attracted great attention because of their fibrous structure and high aspect ratio. Here the genotoxic potential of 400–800 nm, 1–3 μm and 5–30 μm SWCNT with respect to their geometry and surface characteristics was studied. Following thorough physico-chemical characterisation, human bronchial epithelial (BEAS−2B) and lymphoblastoid (MCL-5) cells were treated with SWCNT for 24 or 48 h. This showed significant increases in micronucleus frequency in a time- and dose-dependent manner in both cell types in the absence of cytotoxicity. Over the same dose range, only 1–3 μm SWCNT gave rise to significant increases in hprt point mutations at doses ≥25 μg/ml. Cellular 2,7-dichlorodihydrofluoresceindiacetate (DCFH-DA) fluorescence assay and RT-PCR for oxidative pathway gene profiling revealed a possible oxidative mechanism for the genotoxicity observed in the 1–3 μm SWCNT. Consequently, this study has demonstrated that SWCNT genotoxicity is dependent on its secondary structure under experimental conditions and oxidative stress alone cannot account for the observed damage.