JXJilei Xu

Jilei Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jilei Xu has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Water attenuation length measurement in JUNO

    by Chuanshi Dong, Jilei Xu, Haoqi Lu, Sibo Wang, Vit Vorobel, Tomas Tmej, Changgen Yang, Yongpeng Zhang, Junyou Chen, Hongzhao Yu, et al.

  • Open Access

    Reconstruction of the effective energy-deposition vertex of muon showers using PMT waveform in a large-scale liquid scintillator detector

    by Junwei Zhang, Yongpeng Zhang, Yongbo Huang, Jilei Xu, Junyou Chen, Yi Wang

    Cosmogenic muon-induced radioactive isotopes pose a significant background source for deep-underground low-background experiments. Although rock overburdens at underground sites substantially attenuate the cosmogenic muon flux, residual muon-induced backgrounds still require active suppression. For future multi-kiloton liquid scintillator (LS) detectors, such as the Jiangmen Underground Neutrino Observatory (JUNO), shower muons contribute to more than 88% of all muon-induced isotopes. Consequently, precise reconstruction of shower vertices is essential for implementing localized spatial vetoes. We propose a novel waveform-based method to reconstruct the shower vertex, defined as the energy-deposition centroid in radius of 2 m. By subtracting the track contributions from non-shower muons in the recorded waveforms, the isolated shower component is extracted. Subsequently, using a photon propagation model and an iterative optimization algorithm, the shower vertex positions are reconstructed. Simulations show that for 68% of events, the single shower vertex resolution is better than 0.16 m, 0.15 m, and 0.26 m along X, Y, and Z respectively. Furthermore, the reconstruction efficiency exceeds 96% when requiring the distance between the reconstructed and true vertices to be less than 3.0 m. This method provides a critical technical foundation for muon-induced background suppression in JUNO and other large-scale LS detectors.


  • Design, waterproofing, and mass production of the 3-inch PMT frontend system of JUNO

    by Jilei Xu, Miao He, Cédric Cerna, Yongbo Huang, Thomas Adam, Shakeel Ahmad, Rizwan Ahmed, Fengpeng An, Costas Andreopoulos, Giuseppe Andronico, et al.


  • Study of a compact device for water attenuation length measurements

    by Junyou Chen, Jilei Xu, Yongbo Huang, Sibo Wang, Chuanshi Dong, Haoqi Lu, Changgen Yang, Yongpeng Zhang, Yi Wang

    This study presents the development and validation of a compact device for measuring the water attenuation length (WAL), utilizing photomultiplier tubes (PMTs), optical fibers, and light-emitting diodes (LEDs). An 8 m water tank and the device was constructed and validated in the laboratory. The device is capable of measuring WAL values up to 50 m. The stray light was blocked mainly by a custom-designed shutter. Toy Monte Carlo simulations were employed to evaluate the measurement uncertainty, which was found to be within reasonable limits. These simulations further indicate that the uncertainty can be reduced and more accurately predicted for a larger-scale device with a length of 30 m. Real-time monitoring was achieved by integrating the device into a water purification circulation system, providing a practical, scalable solution for WAL measurement in future large-scale water Cherenkov detectors.


  • A novel design for 100 meter-scale water attenuation length measurement and monitoring

    by Li Wang, Jilei Xu, Shuxiang Lu, Haoqi Lu, Zhimin Wang, Min Li, Sibo Wang, Changgen Yang, Yongpeng Zhang, Yichen Zheng

    Water Cherenov detector is a vital part in most of neutrino or cosmic ray research. As detectors grow in size, the water attenuation length (WAL) becomes increasingly essential for detector performance. It is essential to measure or monitor the WAL. There are two ways to measure WAL, one is to take a water sample from the detector and measure it in the WAL measurement device, and the other is to put the device directly into the water Cherenkov detector. For the device in the water, the Super-Kamiokande experiment achieved WAL measurement capability near 100 meters with a moving light source up and down. A novel system has been proposed to address the challenge of investigating long WAL. This system focuses on ample water Cherenkov detectors and features a fixed light source and photomultiplier tubes (PMTs) at varying distances, eliminating the need for moving parts. Each component, including LED, diffuse ball, PMTs, and fibers, is introduced to explain uncertainty control. Based on lab tests, the measurement uncertainty of each PMT channel has been controlled within 5%. Additionally, camera technology is also used during the evaluation of the system uncertainty, which has the potential to replace PMTs in the future for this measurement. Monte Carlo simulations have shown that the system can achieve a 5% uncertainty at WAL of 80 meters and 8% at WAL of 100 meters. This system can be used in experiments with large Cherenkov detectors such as JUNO-water veto and Hyper-K.


  • Open Access

    A novel design for 100 meter-scale water attenuation length measurement and monitoring

    by Li Wang, Jilei Xu, Shuxiang Lu, Haoqi Lu, Zhimin Wang, Min Li, Sibo Wang, Changgen Yang, Yichen Zheng

    Water Cherenov detector is a vital part in most of neutrino or cosmic ray research. As detectors grow in size, the water attenuation length (WAL) becomes increasingly essential for detector performance. It is essential to measure or monitor the WAL. While many experiments have measured WAL in the lab or detector, only the Super-Kamiokande experiment has achieved values exceeding 50 meters in the detector with a moving light source. However, it is impractical for many experiments to place a moving light source inside the detector, necessitating an alternative method for investigating long WAL. A novel system has been proposed to address the challenge of investigating long WAL. This system focuses on ample water Cherenkov detectors and features a fixed light source and photomultiplier tubes (PMTs) at varying distances, eliminating the need for moving parts. The static setup demands high precision for accurate measurement of long WAL. Each component, including LED, diffuse ball, PMTs, and fibers, is introduced to explain uncertainty control. Based on lab tests, the system's uncertainty has been controlled within 5\%. Additionally, camera technology is also used during the evaluation of the system uncertainty, which has the potential to replace PMTs in the future for this measurement. Monte Carlo simulations have shown that the system can achieve a 5\% measurement uncertainty at WAL of 80 meters and 8\% at WAL of 100 meters. This system can be used in experiments with large Cherenkov detectors such as JUNO water veto and Hyper-K.

  • A Pumping Well Wireless Communication Technology Based on Load Pulse of Sucker Rod

    by Qinghai Yang, Chenglong Liao, Zhongxian Hao, Qiaochu Shen, Jilei Xu, Hongyu Zhao, Yuan Li, Shuming Du

    Pumping wells are characterized by fluid discontinuity, complex media, and periodic pump inspection. The data transmission technology, such as preset cable and pressure wave, which are widely used in injection wells, suffers from many problems when applied in pumping wells, such as high cost, complicated technique, and not suitable for pump inspection operation. As a result, there is an urgent need to develop low-cost wireless transmission technologies suitable for pumping well. This paper proposes an innovative wireless communication technology for pumping well based on the load pulse of sucker rod. Its main components include a downhole load pulse generator (DLPG) and a ground communication controller (GCC). The DLPG is installed between the tubing pump barrel and the stationary valve and is equipped with an 8.5 mm diameter stepless adjusting valve that provides access between the pump chamber and annulus. During the operation of the pumping unit, adjusting the opening or closing state of the adjusting valve can change the working state of the tubing pump and thus change the normal lifting load of the pumping unit. Therefore, wireless uploading of downhole data can be realized by modulating downhole data into lifting load pulse and demodulating of load pulse by the GCC. The principle and transmission characteristics of the technology have been tested in Jilin Oilfield. The results show that the opening or closing of the adjusting valve of the DLPG generate controllable and identifiable lifting load pulses at the wellhead. Moreover, with the increasing opening of the adjusting valve, the lifting load increases significantly. The average load when the adjusting valve is fully opened is 33.65kN, an increase of 64.7% compared with the normal lifting load. When the adjusting valve is completely closed, the lifting load quickly drops to normal. In addition, at 980 m pump setting depth, the response delay of lifting load dynamic change is very small. The pressure sensor of the DLPG can recognize the pressure changes of the pump chamber and accurately judge the up and down stroke. Using stroke recognition and load pulse automatic control, the downhole data uploading is successfully realized, and the technical principle and feasibility are verified. This technology realizes wireless uploading of downhole data without changing the structure and working mode of the existing pumping well. It has the advantages of simple structure, easy installation, low cost, and no influence of pump inspection operation. It can be adapted to the current situation of the large number and wide distribution of pumping wells in China, and is expected to provide a new means of communication for improving the downhole understanding of pumping wells.


  • Reconstruction of a muon bundle in the JUNO central detector

    by Cheng-Feng Yang, Yong-Bo Huang, Ji-Lei Xu, Di-Ru Wu, Yong-Peng Zhang, Wu-Ming Luo, Miao He, Guo-Ming Chen, Si-Yuan Zhang


  • Mass production and characterization of 3-inch PMTs for the JUNO experiment

    by Chuanya Cao, Jilei Xu, Miao He, Angel Abusleme, Mathieu Bongrand, Clément Bordereau, Dominique Breton, Anatael Cabrera, Agustin Campeny, Cédric Cerna, et al.