Nikhilkumar Shah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nikhilkumar Shah has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ming Jun Huang
School of the Built Environment, Ulster University, Belfast BT15 1AP, UK
4 shared publications N.J. Hewitt
3 shared publicationsNeil Hewitt
3 shared publicationsChristopher Wilson
2 shared publications- Neil James Hewitt
Ulster University Belfast UK
2 shared publications - Sreehari Sreekumar
Centre for Sustainable Technologies (CST), Belfast School of Architecture and the Built Environment, Ulster University, Belfast BT15 1ED, Northern Ireland, UK
2 shared publications
Latest Publications
- Open Access
- 28 April 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (9) , 774
Performance Prediction and Optimization of Nanofluid-Based PV/T Using Numerical Simulation and Response Surface Methodology
A numerical investigation was carried out in ANSYS Fluent® on a photovoltaic/thermal (PV/T) system with MXene/water nanofluid as heat transfer fluid (HTF). The interaction of different operating parameters (nanofluid mass fraction, mass flow rate, inlet temperature and incident radiation) on the output response of the system (thermal efficiency, electrical efficiency, thermal exergy efficiency, and electrical exergy efficiency) was studied using a predictive model generated using response surface methodology (RSM). The analysis of variance (ANOVA) method was used to evaluate the significance of input parameters affecting the energy and exergy efficiencies of the nanofluid-based PV/T system. The nanofluid mass flow rate was discovered to be having an impact on the thermal efficiency of the system. Electrical efficiency, thermal exergy efficiency, and electrical exergy efficiency were found to be greatly influenced by incident solar radiation. The percentage contribution of each factor on the output response was calculated. Input variables were optimized using the desirability function to maximize energy and exergy efficiency. The developed statistical model generated an optimum value for the mass flow rate (71.84 kgh−1), the mass fraction (0.2 wt%), incident radiation (581 Wm−2), and inlet temperature (20 °C). The highest overall energy and exergy efficiency predicted by the model were 81.67% and 18.6%, respectively.
- 28 April 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (9) , 774
Open AccessPerformance Prediction and Optimization of Nanofluid-Based PV/T Using Numerical Simulation and Response Surface Methodology
A numerical investigation was carried out in ANSYS Fluent® on a photovoltaic/thermal (PV/T) system with MXene/water nanofluid as heat transfer fluid (HTF). The interaction of different operating parameters (nanofluid mass fraction, mass flow rate, inlet temperature and incident radiation) on the output response of the system (thermal efficiency, electrical efficiency, thermal exergy efficiency, and electrical exergy efficiency) was studied using a predictive model generated using response surface methodology (RSM). The analysis of variance (ANOVA) method was used to evaluate the significance of input parameters affecting the energy and exergy efficiencies of the nanofluid-based PV/T system. The nanofluid mass flow rate was discovered to be having an impact on the thermal efficiency of the system. Electrical efficiency, thermal exergy efficiency, and electrical exergy efficiency were found to be greatly influenced by incident solar radiation. The percentage contribution of each factor on the output response was calculated. Input variables were optimized using the desirability function to maximize energy and exergy efficiency. The developed statistical model generated an optimum value for the mass flow rate (71.84 kgh−1), the mass fraction (0.2 wt%), incident radiation (581 Wm−2), and inlet temperature (20 °C). The highest overall energy and exergy efficiency predicted by the model were 81.67% and 18.6%, respectively.
- Open Access
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 3878-3885
High Temperature Air Source Heat Pump Coupled with Thermal Energy Storage: Comparative Performances and Retrofit Analysis
- 1 February 2019
- Published by Elsevier in Energy Procedia
- Vol. 158, 3878-3885
Open AccessHigh Temperature Air Source Heat Pump Coupled with Thermal Energy Storage: Comparative Performances and Retrofit Analysis
- 1 October 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 143, 650-659
Analysis on field trial of high temperature heat pump integrated with thermal energy storage in domestic retrofit installation
- 1 October 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 143, 650-659
Analysis on field trial of high temperature heat pump integrated with thermal energy storage in domestic retrofit installation
- Open Access
- 1 January 2017
- Published by Elsevier in Applied Energy
- Vol. 186, 530-538
Performance analysis of biofuel fired trigeneration systems with energy storage for remote households
- 1 January 2017
- Published by Elsevier in Applied Energy
- Vol. 186, 530-538
Open AccessPerformance analysis of biofuel fired trigeneration systems with energy storage for remote households
- 1 September 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 108, 181-191
Performance analysis of diesel engine heat pump incorporated with heat recovery
- 1 September 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 108, 181-191
Performance analysis of diesel engine heat pump incorporated with heat recovery
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 522-531
Experimental study of a diesel engine heat pump in heating mode for domestic retrofit application
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 522-531
Experimental study of a diesel engine heat pump in heating mode for domestic retrofit application
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
High temperature heat pump operational experience as a retrofit technology in domestic sector
This paper presents operational experience of high temperature heat pump in domestic building as a retrofit technology where it displaced existing gas boiler without any modification/replacement to existing controller or radiators in the house. Heat pump was integrated with 600l thermal storage where their performance was measured for five months from November 2014 to April 2015. During five months, performance under different settings such as direct mode, storage mode and combined mode operation were analysed. Operational experience shows limitation and issues of heat pump, house heat loss/insulation and sizing of thermal storage. More details about heating demand, COP, power consumption fluctuation and storage mode performance etc., have been presented in details. This operational analysis on heat pump would give information to installer, designer and government organization regarding field trial of heat pump, design consideration and proper sizing and selection of heat pump and thermal storage as a means of demand side management technology for domestic retrofit application.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
High temperature heat pump operational experience as a retrofit technology in domestic sector
This paper presents operational experience of high temperature heat pump in domestic building as a retrofit technology where it displaced existing gas boiler without any modification/replacement to existing controller or radiators in the house. Heat pump was integrated with 600l thermal storage where their performance was measured for five months from November 2014 to April 2015. During five months, performance under different settings such as direct mode, storage mode and combined mode operation were analysed. Operational experience shows limitation and issues of heat pump, house heat loss/insulation and sizing of thermal storage. More details about heating demand, COP, power consumption fluctuation and storage mode performance etc., have been presented in details. This operational analysis on heat pump would give information to installer, designer and government organization regarding field trial of heat pump, design consideration and proper sizing and selection of heat pump and thermal storage as a means of demand side management technology for domestic retrofit application.