Bertinho Andrade Costa
Bertinho Andrade Costa has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Joao Miranda Lemos
INESC-ID, Instituto Superior Tcnico, Universidade de Lisboa, Lisbon, Portugal
18 shared publications - Teresa Mendonça
Universidade do Porto
6 shared publications - Leonel Sousa
INESC-ID
3 shared publications Daniela V. Caiado
2 shared publications- Filipe Arroyo Cardoso
Delft University of Technology 1 Department of Microelectronics Delft
2 shared publications - Hugo Alexandre Ferreira
University of Lisbon
2 shared publications
Latest Publications
- 6 February 2024
- Published by Elsevier in Neurocomputing
- Vol. 577
A reinforcement learning approach for adaptive tracking control of a reusable rocket model in a landing scenario
- 6 February 2024
- Published by Elsevier in Neurocomputing
- Vol. 577
A reinforcement learning approach for adaptive tracking control of a reusable rocket model in a landing scenario
- 2 July 2022
- Published by Springer Nature
- p. 320-329
Control of a S-I-R Epidemiological Model
- 14 June 2022
- Published by Springer Nature
- p. 979-994
A Control Approach to Energy Supply–Demand Markets
- 14 June 2022
- Published by Springer Nature
- p. 979-994
A Control Approach to Energy Supply–Demand Markets
- 19 July 2021
- Published by Wiley in Advanced Control for Applications
- Vol. 3 (4) , e87
GALENO: Computer aided system for modeling, monitoring, and control in anesthesia
This article presents a real‐time software platform (the GALENO platform) that was designed to support the development of algorithms to automate anesthesia procedures. Automation of anesthesia can contribute to improve the anesthesia practice, by personalizing health care, and by allowing the anesthesiologist to concentrate on supervisory tasks, avoiding repetitive manual work that can be executed and optimized by using automatic control systems. The GALENO platform is used for rapid prototyping of new control algorithms applied to anesthesia and was developed to be used by medical staff as a supporting tool for general anesthesia in a clinical setting. It has been tested in simulation and in real clinical settings. The platform can control the administration of several anesthetic drug combinations for total intravenous anesthesia using the DoA/BIS index and the NMB level, during induction and maintenance phases. To highlight some of the main features of the platform, and its practical results, two control algorithms are used as examples, the closed‐loop predictive min–max target controlled infusion is described and is used to control DoA/BIS, and a self‐tuning proportional‐integral‐derivative is used to implement the control of the NMB.
- 19 July 2021
- Published by Wiley in Advanced Control for Applications
- Vol. 3 (4) , e87
GALENO: Computer aided system for modeling, monitoring, and control in anesthesia
This article presents a real‐time software platform (the GALENO platform) that was designed to support the development of algorithms to automate anesthesia procedures. Automation of anesthesia can contribute to improve the anesthesia practice, by personalizing health care, and by allowing the anesthesiologist to concentrate on supervisory tasks, avoiding repetitive manual work that can be executed and optimized by using automatic control systems. The GALENO platform is used for rapid prototyping of new control algorithms applied to anesthesia and was developed to be used by medical staff as a supporting tool for general anesthesia in a clinical setting. It has been tested in simulation and in real clinical settings. The platform can control the administration of several anesthetic drug combinations for total intravenous anesthesia using the DoA/BIS index and the NMB level, during induction and maintenance phases. To highlight some of the main features of the platform, and its practical results, two control algorithms are used as examples, the closed‐loop predictive min–max target controlled infusion is described and is used to control DoA/BIS, and a self‐tuning proportional‐integral‐derivative is used to implement the control of the NMB.
- 9 September 2020
- Published by Springer Nature
- p. 648-657
Trajectory Planning for Landing with a Direct Optimal Control Algorithm
- 9 September 2020
- Published by Springer Nature
- p. 648-657
Trajectory Planning for Landing with a Direct Optimal Control Algorithm
- 1 January 2018
- Published by Elsevier in Solar Energy
- Vol. 159, 66-77
Solar furnace temperature control with active cooling
- 1 January 2018
- Published by Elsevier in Solar Energy
- Vol. 159, 66-77
Solar furnace temperature control with active cooling
- 4 September 2016
- Published by Springer Nature
- p. 131-141
Drug Administration Design for Cancer Gompertz Model Based on the Lyapunov Method
- 4 September 2016
- Published by Springer Nature
- p. 131-141
Drug Administration Design for Cancer Gompertz Model Based on the Lyapunov Method
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 583-588
Temperature control of a solar tower receiver based on the Lyapunov method
This article describes an approach to design a temperature controller for a solar tower receiver that receives concentrated solar energy from a field of heliostats and is employed to transfers energy to a heat transfer fluid (HTF), such as molten salt. During the operation of solar receiver, its temperature and the temperature of the HTF fluid must be controlled to obtain the maximum economical yield constrained by operational safety margins and by the designed life span of the receiver. To attain this purpose, fluid flow and the positions of the heliostats are used as manipulated variables to control the error between the temperature reference and the temperature of the fluid at the receiver outlet. The presence of disturbances is an important factor to consider during the receiver operation. They include solar energy fluctuations caused by weather conditions, presence of moving clouds, the apparent movement of the sun, and wind that can change energy losses. The controller is designed in two steps. In the first step, the thermal stationary operating point of the solar receiver is defined and is used to build a nonlinear dynamical equation of the temperature error. In the second step, the stability of the nonlinear error dynamics, that depends on the speed of the fluid and on the concentrating power of the heliostats, is analyzed using the Lyapunov method. From this analysis the control system is defined, resulting in a nonlinear feed-forward term used to compensate the solar energy fluctuations, and a statefeedback controller that adjusts the the fluid flow to compensate temperature deviations from the temperature reference.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 583-588
Temperature control of a solar tower receiver based on the Lyapunov method
This article describes an approach to design a temperature controller for a solar tower receiver that receives concentrated solar energy from a field of heliostats and is employed to transfers energy to a heat transfer fluid (HTF), such as molten salt. During the operation of solar receiver, its temperature and the temperature of the HTF fluid must be controlled to obtain the maximum economical yield constrained by operational safety margins and by the designed life span of the receiver. To attain this purpose, fluid flow and the positions of the heliostats are used as manipulated variables to control the error between the temperature reference and the temperature of the fluid at the receiver outlet. The presence of disturbances is an important factor to consider during the receiver operation. They include solar energy fluctuations caused by weather conditions, presence of moving clouds, the apparent movement of the sun, and wind that can change energy losses. The controller is designed in two steps. In the first step, the thermal stationary operating point of the solar receiver is defined and is used to build a nonlinear dynamical equation of the temperature error. In the second step, the stability of the nonlinear error dynamics, that depends on the speed of the fluid and on the concentrating power of the heliostats, is analyzed using the Lyapunov method. From this analysis the control system is defined, resulting in a nonlinear feed-forward term used to compensate the solar energy fluctuations, and a statefeedback controller that adjusts the the fluid flow to compensate temperature deviations from the temperature reference.
- 1 January 2015
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 321-330
Temperature Control of a Solar Furnace with Exact Linearization and Off-Line Identification
- 1 January 2015
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 321-330
Temperature Control of a Solar Furnace with Exact Linearization and Off-Line Identification
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems
- Vol. 34 (6) , 24-38
Robust Control of Maintenance-Phase Anesthesia [Applications of Control]
In biomedical systems, feedback control can be applied whenever adequate sensors, actuators, and sufficiently accurate mathematical models are available. The key issue is the capacity of the control algorithm to tackle the large levels of uncertainty, both structured and unstructured, associated with patient dynamics. In the particular case of intravenous anesthesia considered here, manipulated variables are drug infusion rates, administered by syringe pumps, and the measured signal outputs are the levels of hypnosis or depth of anesthesia (DoA) and of neuromuscular blockade (NMB).
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems
- Vol. 34 (6) , 24-38
Robust Control of Maintenance-Phase Anesthesia [Applications of Control]
In biomedical systems, feedback control can be applied whenever adequate sensors, actuators, and sufficiently accurate mathematical models are available. The key issue is the capacity of the control algorithm to tackle the large levels of uncertainty, both structured and unstructured, associated with patient dynamics. In the particular case of intravenous anesthesia considered here, manipulated variables are drug infusion rates, administered by syringe pumps, and the measured signal outputs are the levels of hypnosis or depth of anesthesia (DoA) and of neuromuscular blockade (NMB).