Thomas W. Murphy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas W. Murphy has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
E. G. Adelberger
Center for Experimental Nuclear Physics and Astrophysics University of Washington Box 354290 98195-4290 Seattle WA USA
6 shared publicationsJ. B. R. Battat
Department of Physics Wellesley College 106 Central St 02481 Wellesley MA USA
6 shared publicationsK. Nordtvedt
6 shared publicationsC. D. Hoyle
Department of Physics and Astronomy Humboldt State University One Harpst St 95521-8299 Arcata CA USA
5 shared publicationsE. L. Michelsen
5 shared publicationsH. E. Swanson
5 shared publications
Latest Publications
- Open Access
- 1 October 2023
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 135 (1052) , 104503
Fifteen Years of Millimeter Accuracy Lunar Laser Ranging with APOLLO: Data Reduction and Calibration
The Apache Point Lunar Laser-ranging Operation (APOLLO) has been collecting lunar range measurements for 15 yr at millimeter accuracy. The median nightly range uncertainty since 2006 is 1.7 mm. A recently added Absolute Calibration System (ACS), providing an independent assessment of APOLLO system accuracy and the capability to correct lunar range data, revealed a ∼0.4% (10 ps) systematic error in the calibration of one piece of hardware that has been present for the entire history of APOLLO. The application of ACS-based timing corrections suggests systematic errors are reduced to <1 mm, such that overall data accuracy and precision are both ∼1 mm. This paper describes the processing of APOLLO/ACS data that converts photon-by-photon range measurements into the aggregated normal points that are used for science analyses. Additionally, we present methodologies to estimate timing corrections for range data lacking contemporaneous ACS photons, including range data collected prior to installation of the ACS. We also provide access to the full 15 yr archive of APOLLO normal points (2006 April 6–2020 December 27).
- 1 October 2023
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 135 (1052) , 104503
Open AccessFifteen Years of Millimeter Accuracy Lunar Laser Ranging with APOLLO: Data Reduction and Calibration
The Apache Point Lunar Laser-ranging Operation (APOLLO) has been collecting lunar range measurements for 15 yr at millimeter accuracy. The median nightly range uncertainty since 2006 is 1.7 mm. A recently added Absolute Calibration System (ACS), providing an independent assessment of APOLLO system accuracy and the capability to correct lunar range data, revealed a ∼0.4% (10 ps) systematic error in the calibration of one piece of hardware that has been present for the entire history of APOLLO. The application of ACS-based timing corrections suggests systematic errors are reduced to <1 mm, such that overall data accuracy and precision are both ∼1 mm. This paper describes the processing of APOLLO/ACS data that converts photon-by-photon range measurements into the aggregated normal points that are used for science analyses. Additionally, we present methodologies to estimate timing corrections for range data lacking contemporaneous ACS photons, including range data collected prior to installation of the ACS. We also provide access to the full 15 yr archive of APOLLO normal points (2006 April 6–2020 December 27).
- Open Access
- 1 September 2023
- Published by American Association of Physics Teachers (AAPT) in The Physics Teacher
- Vol. 61 (6) , 512-515
The Physics of Limits
Physics offers a solid foundation upon which to build simple yet powerful perspectives on challenges we face inhabiting a finite planet. This work offers sugges
- 1 September 2023
- Published by American Association of Physics Teachers (AAPT) in The Physics Teacher
- Vol. 61 (6) , 512-515
Open AccessThe Physics of Limits
Physics offers a solid foundation upon which to build simple yet powerful perspectives on challenges we face inhabiting a finite planet. This work offers sugges
- 21 July 2022
- Published by Springer Nature in Nature Physics
- Vol. 18 (8) , 844-847
Limits to economic growth
- 21 July 2022
- Published by Springer Nature in Nature Physics
- Vol. 18 (8) , 844-847
Limits to economic growth
- 22 November 2017
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 34 (24) , 245008
An absolute calibration system for millimeter-accuracy APOLLO measurements
Lunar laser ranging provides a number of leading experimental tests of gravitation—important in our quest to unify general relativity and the standard model of physics. The apache point observatory lunar laser-ranging operation (APOLLO) has for years achieved median range precision at the ∼2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in situ . The system consists of a high-repetition-rate (80 MHz) laser emitting short ( < 10 ps) pulses that are locked to a cesium clock. In essence, the ACS delivers photons to the APOLLO detector at exquisitely well-defined time intervals as a ‘truth’ input against which APOLLO’s timing performance may be judged and corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond the ∼3 mm level, suggesting that historical APOLLO data are of high quality and motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.
- 22 November 2017
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 34 (24) , 245008
An absolute calibration system for millimeter-accuracy APOLLO measurements
Lunar laser ranging provides a number of leading experimental tests of gravitation—important in our quest to unify general relativity and the standard model of physics. The apache point observatory lunar laser-ranging operation (APOLLO) has for years achieved median range precision at the ∼2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in situ . The system consists of a high-repetition-rate (80 MHz) laser emitting short ( < 10 ps) pulses that are locked to a cesium clock. In essence, the ACS delivers photons to the APOLLO detector at exquisitely well-defined time intervals as a ‘truth’ input against which APOLLO’s timing performance may be judged and corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond the ∼3 mm level, suggesting that historical APOLLO data are of high quality and motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.
- 22 November 2017
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 34 (24) , 245009
APOLLO clock performance and normal point corrections
The Apache point observatory lunar laser-ranging operation (APOLLO) has produced a large volume of high-quality lunar laser ranging (LLR) data since it began operating in 2006. For most of this period, APOLLO has relied on a GPS-disciplined, high-stability quartz oscillator as its frequency and time standard. The recent addition of a cesium clock as part of a timing calibration system initiated a comparison campaign between the two clocks. This has allowed correction of APOLLO range measurements—called normal points—during the overlap period, but also revealed a mechanism to correct for systematic range offsets due to clock errors in historical APOLLO data. Drift of the GPS clock on ∼1000 s timescales contributed typically 2.5 mm of range error to APOLLO measurements, and we find that this may be reduced to ∼1.6 mm on average. We present here a characterization of APOLLO clock errors, the method by which we correct historical data, and the resulting statistics.
- 22 November 2017
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 34 (24) , 245009
APOLLO clock performance and normal point corrections
The Apache point observatory lunar laser-ranging operation (APOLLO) has produced a large volume of high-quality lunar laser ranging (LLR) data since it began operating in 2006. For most of this period, APOLLO has relied on a GPS-disciplined, high-stability quartz oscillator as its frequency and time standard. The recent addition of a cesium clock as part of a timing calibration system initiated a comparison campaign between the two clocks. This has allowed correction of APOLLO range measurements—called normal points—during the overlap period, but also revealed a mechanism to correct for systematic range offsets due to clock errors in historical APOLLO data. Drift of the GPS clock on ∼1000 s timescales contributed typically 2.5 mm of range error to APOLLO measurements, and we find that this may be reduced to ∼1.6 mm on average. We present here a characterization of APOLLO clock errors, the method by which we correct historical data, and the resulting statistics.
- Open Access
An absolute calibration system for millimeter-accuracy APOLLO measurements
Lunar laser ranging provides a number of leading experimental tests of gravitation -- important in our quest to unify General Relativity and the Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has for years achieved median range precision at the ~2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in-situ. The system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10 ps) pulses that are locked to a cesium clock. In essence, the ACS delivers photons to the APOLLO detector at exquisitely well-defined time intervals as a "truth" input against which APOLLO's timing performance may be judged and corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond the ~3 mm level, suggesting that historical APOLLO data are of high quality and motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.
Open AccessAn absolute calibration system for millimeter-accuracy APOLLO measurements
Lunar laser ranging provides a number of leading experimental tests of gravitation -- important in our quest to unify General Relativity and the Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has for years achieved median range precision at the ~2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in-situ. The system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10 ps) pulses that are locked to a cesium clock. In essence, the ACS delivers photons to the APOLLO detector at exquisitely well-defined time intervals as a "truth" input against which APOLLO's timing performance may be judged and corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond the ~3 mm level, suggesting that historical APOLLO data are of high quality and motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.
- Open Access
APOLLO clock performance and normal point corrections
The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has produced a large volume of high-quality lunar laser ranging (LLR) data since it began operating in 2006. For most of this period, APOLLO has relied on a GPS-disciplined, high-stability quartz oscillator as its frequency and time standard. The recent addition of a cesium clock as part of a timing calibration system initiated a comparison campaign between the two clocks. This has allowed correction of APOLLO range measurements--called normal points--during the overlap period, but also revealed a mechanism to correct for systematic range offsets due to clock errors in historical APOLLO data. Drift of the GPS clock on ~1000 s timescales contributed typically 2.5 mm of range error to APOLLO measurements, and we find that this may be reduced to ~1.6 mm on average. We present here a characterization of APOLLO clock errors, the method by which we correct historical data, and the resulting statistics.
Open AccessAPOLLO clock performance and normal point corrections
The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has produced a large volume of high-quality lunar laser ranging (LLR) data since it began operating in 2006. For most of this period, APOLLO has relied on a GPS-disciplined, high-stability quartz oscillator as its frequency and time standard. The recent addition of a cesium clock as part of a timing calibration system initiated a comparison campaign between the two clocks. This has allowed correction of APOLLO range measurements--called normal points--during the overlap period, but also revealed a mechanism to correct for systematic range offsets due to clock errors in historical APOLLO data. Drift of the GPS clock on ~1000 s timescales contributed typically 2.5 mm of range error to APOLLO measurements, and we find that this may be reduced to ~1.6 mm on average. We present here a characterization of APOLLO clock errors, the method by which we correct historical data, and the resulting statistics.
- 1 May 2016
- Published by American Association of Physics Teachers (AAPT) in The Physics Teacher
- Vol. 54 (5) , 272-276
Confronting Twin Paradox Acceleration
The resolution to the classic twin paradox in special relativity rests on the asymmetry of acceleration. Yet most students are not exposed to a satisfactory analysis of what exactly happens during the acceleration phase that results in the nonaccelerated observer's more rapid aging. The simple treatment presented here offers both graphical and quantitative solutions to the problem, leading to the correct result that the acceleration-induced age gap is 2Lβ years when the one-way distance L is expressed in light-years and velocity β≡vc.
- 1 May 2016
- Published by American Association of Physics Teachers (AAPT) in The Physics Teacher
- Vol. 54 (5) , 272-276
Confronting Twin Paradox Acceleration
The resolution to the classic twin paradox in special relativity rests on the asymmetry of acceleration. Yet most students are not exposed to a satisfactory analysis of what exactly happens during the acceleration phase that results in the nonaccelerated observer's more rapid aging. The simple treatment presented here offers both graphical and quantitative solutions to the problem, leading to the correct result that the acceleration-induced age gap is 2Lβ years when the one-way distance L is expressed in light-years and velocity β≡vc.
- Open Access
Lunar Eclipse Observations Reveal Anomalous Thermal Performance of Apollo Reflectors
Laser ranging measurements during the total lunar eclipse on 2010 December 21 verify previously suspected thermal lensing in the retroreflectors left on the lunar surface by the Apollo astronauts. Signal levels during the eclipse far exceeded those historically seen at full moon, and varied over an order of magnitude as the eclipse progressed. These variations can be understood via a straightforward thermal scenario involving solar absorption by a ~50% covering of dust that has accumulated on the front surfaces of the reflectors. The same mechanism can explain the long-term degradation of signal from the reflectors as well as the acute signal deficit observed near full moon.
Open AccessLunar Eclipse Observations Reveal Anomalous Thermal Performance of Apollo Reflectors
Laser ranging measurements during the total lunar eclipse on 2010 December 21 verify previously suspected thermal lensing in the retroreflectors left on the lunar surface by the Apollo astronauts. Signal levels during the eclipse far exceeded those historically seen at full moon, and varied over an order of magnitude as the eclipse progressed. These variations can be understood via a straightforward thermal scenario involving solar absorption by a ~50% covering of dust that has accumulated on the front surfaces of the reflectors. The same mechanism can explain the long-term degradation of signal from the reflectors as well as the acute signal deficit observed near full moon.