Samu Varjonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samu Varjonen has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Sasu Tarkoma
University of Helsinki
14 shared publications - Naser Hossein Motlagh
University of Helsinki
7 shared publications - Martha Arbayani Zaidan
University of Helsinki
6 shared publications - Pak Lun Fung
University of Helsinki, Helsinki, Sodra Finlands Lan, Finland
6 shared publications - Eemil Lagerspetz
University of Helsinki, Finland
5 shared publications - Andrew Rebeiro-Hargrave
Department of Computer Science, University of Helsinki, Helsinki, Sodra Finlands Lan, Finland
4 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 59850-59864
Measuring the Atmosphere: Environmental Sensing for Occupant Flows in Commercial Spaces
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 59850-59864
Measuring the Atmosphere: Environmental Sensing for Occupant Flows in Commercial Spaces
- Open Access
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 7692-7705
Indoor–Outdoor Detection Using Low-Cost Air Quality Sensors
Distinguishing between indoor and outdoor environments is crucial for various location-based applications, including navigation tools and context-aware services. We present an innovative and highly efficient approach that combines air quality sensors with machine learning techniques to achieve this distinction. Extensive experiments across diverse settings—buildings and vehicles—and data from two cities, Helsinki, Finland, and Milan, Italy, with distinct environmental characteristics, demonstrate significant performance improvements. Specifically, our method achieves over 90% accuracy, a 30% increase compared to approaches relying solely on location information. This work highlights a novel application of air quality data and provides an enhanced methodology for accurately distinguishing indoor and outdoor spaces.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 7692-7705
Open AccessIndoor–Outdoor Detection Using Low-Cost Air Quality Sensors
Distinguishing between indoor and outdoor environments is crucial for various location-based applications, including navigation tools and context-aware services. We present an innovative and highly efficient approach that combines air quality sensors with machine learning techniques to achieve this distinction. Extensive experiments across diverse settings—buildings and vehicles—and data from two cities, Helsinki, Finland, and Milan, Italy, with distinct environmental characteristics, demonstrate significant performance improvements. Specifically, our method achieves over 90% accuracy, a 30% increase compared to approaches relying solely on location information. This work highlights a novel application of air quality data and provides an enhanced methodology for accurately distinguishing indoor and outdoor spaces.
- Open Access
- 23 June 2025
- Published by Association for Computing Machinery (ACM)
- p. 603-604
Poster: IoT-Based Indoor Air Quality Monitoring for Health Risk Assessment and Well-Being
- 23 June 2025
- Published by Association for Computing Machinery (ACM)
- p. 603-604
Open AccessPoster: IoT-Based Indoor Air Quality Monitoring for Health Risk Assessment and Well-Being
- Open Access
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 39 (2) , 36-43
Federated Learning Meets Urban Opportunistic Crowdsensing in 6G Networks: Opportunities, Challenges, and Optimization Potentials
6G networks are envisioned to enable the Internet of Things (IoTs) and foster ubiquitous sensing. Urban opportunistic crowdsensing, which leverages participants carrying mobile sensing units (MSUs) in their daily activities to collect data, enables low-cost and large-scale urban sensing for applications such as air quality monitoring, pothole detection, and noise classification. However, urban opportunistic crowdsensing poses challenges to conventional cloud-based centralized learning due to the unpredictable nature of crowdsensed data collection and privacy concerns from uploading personal information to the centralized cloud. Federated learning (FL), where MSUs act as data sources and computing nodes, offers a promising alternative to mitigating these issues. Despite FL’s potential, urban crowdsensing contexts’ spatial-temporal diversity, mobility, constrained resources, and emerging privacy concerns present new challenges. In this paper, we explore the opportunities and challenges of FL in urban opportunistic sensing in 6G networks and suggest potential optimization strategies. Furthermore, we conduct field experiments in Helsinki, Finland, and design an FL-based air quality calibration method for opportunistic crowdsensing to demonstrate the feasibility of our vision.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 39 (2) , 36-43
Open AccessFederated Learning Meets Urban Opportunistic Crowdsensing in 6G Networks: Opportunities, Challenges, and Optimization Potentials
6G networks are envisioned to enable the Internet of Things (IoTs) and foster ubiquitous sensing. Urban opportunistic crowdsensing, which leverages participants carrying mobile sensing units (MSUs) in their daily activities to collect data, enables low-cost and large-scale urban sensing for applications such as air quality monitoring, pothole detection, and noise classification. However, urban opportunistic crowdsensing poses challenges to conventional cloud-based centralized learning due to the unpredictable nature of crowdsensed data collection and privacy concerns from uploading personal information to the centralized cloud. Federated learning (FL), where MSUs act as data sources and computing nodes, offers a promising alternative to mitigating these issues. Despite FL’s potential, urban crowdsensing contexts’ spatial-temporal diversity, mobility, constrained resources, and emerging privacy concerns present new challenges. In this paper, we explore the opportunities and challenges of FL in urban opportunistic sensing in 6G networks and suggest potential optimization strategies. Furthermore, we conduct field experiments in Helsinki, Finland, and design an FL-based air quality calibration method for opportunistic crowdsensing to demonstrate the feasibility of our vision.
- Open Access
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 11 (10) , 17577-17588
Estimating Black Carbon Levels With Proxy Variables and Low-Cost Sensors
We develop a portable and affordable solution for estimating personal exposure to black carbon (BC) using low-cost sensors and machine learning. Our approach uses other pollutants and environmental variables as proxies for estimating the concentrations of BC and combines this with machine learning based sensor calibration to improve the quality of the inputs that are used as proxies in the modeling. We extensively validate the feasibility of our approach and demonstrate its benefits with benchmarks conducted on real world data from two different urban locations with different population densities and characteristics. Our results demonstrate that our approach can accurately estimate BC (R2 higher than 0.9) without relying on a dedicated sensor. The results also highlight how calibration is essential for ensuring accurate modeling on low-cost sensor measurements. Our results offer a novel affordable and portable solution that can be used to estimate personal exposure to BC and, more generally, demonstrate how low-cost sensors and proxy modeling can increase the spatiotemporal scale at which information about BC level is available.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 11 (10) , 17577-17588
Open AccessEstimating Black Carbon Levels With Proxy Variables and Low-Cost Sensors
We develop a portable and affordable solution for estimating personal exposure to black carbon (BC) using low-cost sensors and machine learning. Our approach uses other pollutants and environmental variables as proxies for estimating the concentrations of BC and combines this with machine learning based sensor calibration to improve the quality of the inputs that are used as proxies in the modeling. We extensively validate the feasibility of our approach and demonstrate its benefits with benchmarks conducted on real world data from two different urban locations with different population densities and characteristics. Our results demonstrate that our approach can accurately estimate BC (R2 higher than 0.9) without relying on a dedicated sensor. The results also highlight how calibration is essential for ensuring accurate modeling on low-cost sensor measurements. Our results offer a novel affordable and portable solution that can be used to estimate personal exposure to BC and, more generally, demonstrate how low-cost sensors and proxy modeling can increase the spatiotemporal scale at which information about BC level is available.
- Open Access
- 21 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 79624-79635
The Application of Mobile Sensing to Detect CO and NO2 Emission Spikes in Polluted Cities
Carbon monoxide (CO) and Nitrogen dioxide (NO 2 ) are major air pollutants that have the potential to affect human health adversely. There is a lack of useful information regarding the spatial distribution and temporal variability of CO and NO 2 emissions in major metropolitan areas. The primary goal of this research is to provide a geospatial data methodology for detecting emission spikes of CO and NO 2 in polluted urban environments employing portable low-cost sensors. We propose that ephemeral identification of harmful gas concentrations can be achieved using different IoT device types mounted on a mobile platform. We propose that persistent identification of the CO and NO 2 emission spikes can be attained by driving through the city on different days. We applied this approach to Hyderabad, India, by fixing a mobile platform on a street car. We corrected the IoT device measurement errors by calibrating the sensing component data against a reference instrument co-located on the mobile platform. We identified that random forest regression was the most suitable technique to reduce the variability between the IoT devices due to heterogeneity in the mobile sensing datasets. The spatial variability of CO and NO 2 harmful emission spikes at a resolution of 50m were identified, but their intensity changes on a daily basis according to meteorological conditions. The temporal variability shows a weak correlation between CO and NO 2 concentrations. The data from the CO and NO 2 emission spikes at Points of Interests that disturb traffic flows clearly show the need for public education about when it is hazardous for persons with respiratory conditions to be outside, as well as when it is unsafe for young children and the elderly to be outside for extended periods of time. This detection strategy is adaptable to any mobile platform used by individuals traveling by foot, bicycle, drone, or robot in any metropolis.
- 21 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 79624-79635
Open AccessThe Application of Mobile Sensing to Detect CO and NO2 Emission Spikes in Polluted Cities
Carbon monoxide (CO) and Nitrogen dioxide (NO 2 ) are major air pollutants that have the potential to affect human health adversely. There is a lack of useful information regarding the spatial distribution and temporal variability of CO and NO 2 emissions in major metropolitan areas. The primary goal of this research is to provide a geospatial data methodology for detecting emission spikes of CO and NO 2 in polluted urban environments employing portable low-cost sensors. We propose that ephemeral identification of harmful gas concentrations can be achieved using different IoT device types mounted on a mobile platform. We propose that persistent identification of the CO and NO 2 emission spikes can be attained by driving through the city on different days. We applied this approach to Hyderabad, India, by fixing a mobile platform on a street car. We corrected the IoT device measurement errors by calibrating the sensing component data against a reference instrument co-located on the mobile platform. We identified that random forest regression was the most suitable technique to reduce the variability between the IoT devices due to heterogeneity in the mobile sensing datasets. The spatial variability of CO and NO 2 harmful emission spikes at a resolution of 50m were identified, but their intensity changes on a daily basis according to meteorological conditions. The temporal variability shows a weak correlation between CO and NO 2 concentrations. The data from the CO and NO 2 emission spikes at Points of Interests that disturb traffic flows clearly show the need for public education about when it is hazardous for persons with respiratory conditions to be outside, as well as when it is unsafe for young children and the elderly to be outside for extended periods of time. This detection strategy is adaptable to any mobile platform used by individuals traveling by foot, bicycle, drone, or robot in any metropolis.
- Open Access
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 37-42
Protocol for hunting PM 2.5 emission hot spots in cities
Particulate Matter (PM) is a major air pollutant that has the potential for adversely affecting human health. Actionable data on the spatial distribution of temporal variability of PM2.5 emission hot spots in large cities are sparse. The main objective of this research is to provide a protocol for using search agents to hunt for PM2.5 emission hot spots in urban environments. We propose short range identification of variability of harmful PM2.5 concentrations can be achieved using IoT devices mounted on a mobile platform. We propose that long range identification the PM2.5 emission hot spots can attained by searching through the city on different days. We applied this approach to Hyderabad, India by fixing a mobile platform on a street car. We corrected the IoT device measurement errors by calibrating the sensing component data against a reference instrument co-located on the mobile platform. We identified that random forest regression was the most suitable technique to reduce the variability between the IoT devices. The spatial variability of PM2.5 harmful emission hot spots at industrial settings and congested roads were identified. The temporal variability based on image processing shows a weak correlation between PM2.5 concentrations and number of vehicles, and PM2.5 and visibility. The Hyderabad PM2.5 emission hot spots findings demonstrate a clear need to inform people with heart and lung conditions when it is unhealthy to be outside; and when it is unhealthy for children and elderly people to be outside for prolonged periods. Our emission hunting approach can be applied to any mobile platform carried by people walking, cycling or by drones and robots in any city.
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 37-42
Open AccessProtocol for hunting PM 2.5 emission hot spots in cities
Particulate Matter (PM) is a major air pollutant that has the potential for adversely affecting human health. Actionable data on the spatial distribution of temporal variability of PM2.5 emission hot spots in large cities are sparse. The main objective of this research is to provide a protocol for using search agents to hunt for PM2.5 emission hot spots in urban environments. We propose short range identification of variability of harmful PM2.5 concentrations can be achieved using IoT devices mounted on a mobile platform. We propose that long range identification the PM2.5 emission hot spots can attained by searching through the city on different days. We applied this approach to Hyderabad, India by fixing a mobile platform on a street car. We corrected the IoT device measurement errors by calibrating the sensing component data against a reference instrument co-located on the mobile platform. We identified that random forest regression was the most suitable technique to reduce the variability between the IoT devices. The spatial variability of PM2.5 harmful emission hot spots at industrial settings and congested roads were identified. The temporal variability based on image processing shows a weak correlation between PM2.5 concentrations and number of vehicles, and PM2.5 and visibility. The Hyderabad PM2.5 emission hot spots findings demonstrate a clear need to inform people with heart and lung conditions when it is unhealthy to be outside; and when it is unhealthy for children and elderly people to be outside for prolonged periods. Our emission hunting approach can be applied to any mobile platform carried by people walking, cycling or by drones and robots in any city.
- Open Access
- 4 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (12) , 11791-11802
Low-Cost Formaldehyde Sensor Evaluation and Calibration in a Controlled Environment
Formaldehyde is a carcinogenic indoor air pollutant emitted from common wood-based materials. Low-cost sensing of formaldehyde is difficult due to inaccuracies in measuring low concentrations and susceptibility of sensors to changing indoor environmental conditions. Currently gas sensors are calibrated by manufacturers using simplistic models which fail to capture their complex behaviour. We evaluated different low-cost gas sensors to ascertain a suitable component to create a mobile sensing node and built a calibration algorithm to correct it. We compared the performance of 2 electrochemical sensors and 3 metal oxide sensors in a controlled chamber against a photo-acoustic reference device. In the chamber the formaldehyde concentrations, temperature and humidity were varied to assess the sensors in diverse environments. Pre-calibration, the electrochemical sensors (mean absolute error (MAE) = 70.8 ppb) outperformed the best performing metal oxide sensor (MAE = 335 ppb). A two-stage calibration model was built, using linear regression followed by random forest, where the residual of the first stage acted as a input for the second. Post-calibration, the metal oxide sensors (MAE = 154 ppb) improved compared to their electrochemical counterparts (MAE = 78.8 ppb). Nevertheless, the uncalibrated electrochemical sensor showed overall superior performance hence was selected for the mobile sensing node.
- 4 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (12) , 11791-11802
Open AccessLow-Cost Formaldehyde Sensor Evaluation and Calibration in a Controlled Environment
Formaldehyde is a carcinogenic indoor air pollutant emitted from common wood-based materials. Low-cost sensing of formaldehyde is difficult due to inaccuracies in measuring low concentrations and susceptibility of sensors to changing indoor environmental conditions. Currently gas sensors are calibrated by manufacturers using simplistic models which fail to capture their complex behaviour. We evaluated different low-cost gas sensors to ascertain a suitable component to create a mobile sensing node and built a calibration algorithm to correct it. We compared the performance of 2 electrochemical sensors and 3 metal oxide sensors in a controlled chamber against a photo-acoustic reference device. In the chamber the formaldehyde concentrations, temperature and humidity were varied to assess the sensors in diverse environments. Pre-calibration, the electrochemical sensors (mean absolute error (MAE) = 70.8 ppb) outperformed the best performing metal oxide sensor (MAE = 335 ppb). A two-stage calibration model was built, using linear regression followed by random forest, where the residual of the first stage acted as a input for the second. Post-calibration, the metal oxide sensors (MAE = 154 ppb) improved compared to their electrochemical counterparts (MAE = 78.8 ppb). Nevertheless, the uncalibrated electrochemical sensor showed overall superior performance hence was selected for the mobile sensing node.
- Open Access
- 15 May 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (5) , 2413-2423
Laboratory evaluation of particle-size selectivity of optical low-cost particulate matter sensors
Low-cost particulate matter (PM) sensors have been under investigation as it has been hypothesized that the use of low-cost and easy-to-use sensors could allow cost-efficient extension of the currently sparse measurement coverage. While the majority of the existing literature highlights that low-cost sensors can indeed be a valuable addition to the list of commonly used measurement tools, it often reiterates that the risk of sensor misuse is still high and that the data obtained from the sensors are only representative of the specific site and its ambient conditions. This implies that there are underlying reasons for inaccuracies in sensor measurements that have yet to be characterized. The objective of this study is to investigate the particle-size selectivity of low-cost sensors. Evaluated sensors were Plantower PMS5003, Nova SDS011, Sensirion SPS30, Sharp GP2Y1010AU0F, Shinyei PPD42NS, and Omron B5W-LD0101. The investigation of size selectivity was carried out in the laboratory using a novel reference aerosol generation system capable of steadily producing monodisperse particles of different sizes (from ∼0.55 to 8.4 µm) on-line. The results of the study show that none of the low-cost sensors adhered to the detection ranges declared by the manufacturers; moreover, cursory comparison to a mid-cost aerosol size spectrometer (Grimm 1.108, 2020) indicates that the sensors can only achieve independent responses for one or two size bins, whereas the spectrometer can sufficiently characterize particles with 15 different size bins. These observations provide insight into and evidence of the notion that particle-size selectivity has an essential role in the analysis of the sources of errors in sensors.
- 15 May 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (5) , 2413-2423
Open AccessLaboratory evaluation of particle-size selectivity of optical low-cost particulate matter sensors
Low-cost particulate matter (PM) sensors have been under investigation as it has been hypothesized that the use of low-cost and easy-to-use sensors could allow cost-efficient extension of the currently sparse measurement coverage. While the majority of the existing literature highlights that low-cost sensors can indeed be a valuable addition to the list of commonly used measurement tools, it often reiterates that the risk of sensor misuse is still high and that the data obtained from the sensors are only representative of the specific site and its ambient conditions. This implies that there are underlying reasons for inaccuracies in sensor measurements that have yet to be characterized. The objective of this study is to investigate the particle-size selectivity of low-cost sensors. Evaluated sensors were Plantower PMS5003, Nova SDS011, Sensirion SPS30, Sharp GP2Y1010AU0F, Shinyei PPD42NS, and Omron B5W-LD0101. The investigation of size selectivity was carried out in the laboratory using a novel reference aerosol generation system capable of steadily producing monodisperse particles of different sizes (from ∼0.55 to 8.4 µm) on-line. The results of the study show that none of the low-cost sensors adhered to the detection ranges declared by the manufacturers; moreover, cursory comparison to a mid-cost aerosol size spectrometer (Grimm 1.108, 2020) indicates that the sensors can only achieve independent responses for one or two size bins, whereas the spectrometer can sufficiently characterize particles with 15 different size bins. These observations provide insight into and evidence of the notion that particle-size selectivity has an essential role in the analysis of the sources of errors in sensors.
- 14 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Magazine
- Vol. 58 (2) , 54-59
Toward Massive Scale Air Quality Monitoring
Dangers associated with poor air quality are driving deployments of air quality monitoring technology. These deployments rely on either professional-grade measurement stations or a small number of low-cost sensors integrated into urban infrastructure. In this article, we present a research vision of real-time massive scale air quality sensing that integrates tens of thousands or even millions of air quality sensors to monitor air quality at fine spatial and temporal resolution. We highlight opportunities and challenges of our vision by discussing use cases, key requirements, and reference technologies in order to establish a roadmap on how to realize this vision. We address the feasibility of our vision, introducing a testbed deployment in Helsinki, Finland, and carrying out controlled experiments that address collaborative and opportunistic sensor calibration, a key research challenge for our vision.
- 14 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Magazine
- Vol. 58 (2) , 54-59
Toward Massive Scale Air Quality Monitoring
Dangers associated with poor air quality are driving deployments of air quality monitoring technology. These deployments rely on either professional-grade measurement stations or a small number of low-cost sensors integrated into urban infrastructure. In this article, we present a research vision of real-time massive scale air quality sensing that integrates tens of thousands or even millions of air quality sensors to monitor air quality at fine spatial and temporal resolution. We highlight opportunities and challenges of our vision by discussing use cases, key requirements, and reference technologies in order to establish a roadmap on how to realize this vision. We address the feasibility of our vision, introducing a testbed deployment in Helsinki, Finland, and carrying out controlled experiments that address collaborative and opportunistic sensor calibration, a key research challenge for our vision.