Antonio Hijano Reyes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonio Hijano Reyes has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
F. J. Higuera
ETSIAE, Universidad Politécnica de Madrid 3 , Madrid, Spain
2 shared publications- Francisco José Higuera
ETSIAE, Universidad Politecnica de Madrid, Plaza Cardenal Cisneros 3, 28040 Madrid, Spain
2 shared publications I. G. Loscertales
Department of Ingeniería Mecánica, Térmica, y de Fluidos, Universidad de Málaga 2 , Málaga, Spain
2 shared publications- Juan Manuel Gallardo Salazar
Ingho (España)
2 shared publications - Rogelio Zubizarreta Jimenez
Universidad de Málaga (España)
2 shared publications - Santiago Enrique Ibáñez
IMDEA Energy Institute
2 shared publications
Latest Publications
- 1 November 2021
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 1052-1059
COMPETENCY-BASED ASSESSMENT IN A BASIC COURSE OF FLUID MECHANICS
Information about the paper titled "COMPETENCY-BASED ASSESSMENT IN A BASIC COURSE OF FLUID MECHANICS" at IATED Digital Library
- 1 November 2021
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 1052-1059
COMPETENCY-BASED ASSESSMENT IN A BASIC COURSE OF FLUID MECHANICS
Information about the paper titled "COMPETENCY-BASED ASSESSMENT IN A BASIC COURSE OF FLUID MECHANICS" at IATED Digital Library
- 15 June 2021
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 920
Modelling the electric microdripping from a needle
Droplet emission from an electrified meniscus in the microdripping regime has been investigated experimentally and numerically. In this regime, the meniscus of a low viscosity, high electrical conductivity liquid hanging from the tip of a metallic tube, oscillates when subjected to a high electric field. When the liquid is fed at a constant flow rate, and for a certain range of voltages, the oscillations are periodic and, in each oscillation, the meniscus develops a ligament that eventually detaches forming a single drop. Thus, this technique is a simple way to produce monodisperse droplets at relatively high frequencies, whose diameters may be one-tenth of that of the tube. The process, governed by a dimensionless flow rate , the computed meniscus mean volume and oscillation frequency agree with the experimental results, although the volume and number of emitted droplets do not. An ultrafine electrospray emitted from the ligament's conical tip during part of the oscillation cycle is probably the cause of the disagreements. To tackle this, we combine the one-dimensional approximation of an electrified meniscus with experimental meniscus profiles to compute the electric field on the meniscus. Around the tip, this electric field turns out to be substantially smaller than the field computed by the model in the absence of the space charge, and agrees with the field induced by an electrospray emitted from a Taylor cone in air.
- 15 June 2021
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 920
Modelling the electric microdripping from a needle
Droplet emission from an electrified meniscus in the microdripping regime has been investigated experimentally and numerically. In this regime, the meniscus of a low viscosity, high electrical conductivity liquid hanging from the tip of a metallic tube, oscillates when subjected to a high electric field. When the liquid is fed at a constant flow rate, and for a certain range of voltages, the oscillations are periodic and, in each oscillation, the meniscus develops a ligament that eventually detaches forming a single drop. Thus, this technique is a simple way to produce monodisperse droplets at relatively high frequencies, whose diameters may be one-tenth of that of the tube. The process, governed by a dimensionless flow rate , the computed meniscus mean volume and oscillation frequency agree with the experimental results, although the volume and number of emitted droplets do not. An ultrafine electrospray emitted from the ligament's conical tip during part of the oscillation cycle is probably the cause of the disagreements. To tackle this, we combine the one-dimensional approximation of an electrified meniscus with experimental meniscus profiles to compute the electric field on the meniscus. Around the tip, this electric field turns out to be substantially smaller than the field computed by the model in the absence of the space charge, and agrees with the field induced by an electrospray emitted from a Taylor cone in air.
- 1 August 2019
- Published by AIP Publishing in Physics of Fluids
- Vol. 31 (8) , 082009
Emission modes in electro co-flow
We apply an electric field to a moderately conducting liquid surrounded by another co-flowing liquid, all inside a glass-based microfluidic device, and study and classify the resulting emission modes. The viscosity and flow rate of the co-flowing liquid affect the number of modes observed in classical electrospray as well as their geometrical characteristics. In particular, we observe a two-dimensional whipping mode not described before. We also provide a qualitative description of some of the modes, including dripping, electrodripping, microdripping, the cone-jet mode, and both the two- and three-dimensional whipping modes.
- 1 August 2019
- Published by AIP Publishing in Physics of Fluids
- Vol. 31 (8) , 082009
Emission modes in electro co-flow
We apply an electric field to a moderately conducting liquid surrounded by another co-flowing liquid, all inside a glass-based microfluidic device, and study and classify the resulting emission modes. The viscosity and flow rate of the co-flowing liquid affect the number of modes observed in classical electrospray as well as their geometrical characteristics. In particular, we observe a two-dimensional whipping mode not described before. We also provide a qualitative description of some of the modes, including dripping, electrodripping, microdripping, the cone-jet mode, and both the two- and three-dimensional whipping modes.
- 1 May 2018
- Published by Publicaciones DYNA in DYNA Ingenieria e Industria
- Vol. 93 (1) , 286-292
MOISTURE REMOVAL ASSESSMENT USING DESICCANT LIQUIDS WITH A BUBBLE-AIR GENERATOR
- 1 May 2018
- Published by Publicaciones DYNA in DYNA Ingenieria e Industria
- Vol. 93 (1) , 286-292
MOISTURE REMOVAL ASSESSMENT USING DESICCANT LIQUIDS WITH A BUBBLE-AIR GENERATOR
- 1 March 2018
- Published by Elsevier in Energy and Buildings
- Vol. 162, 187-197
Electrospray technique to produce fine sprays of desiccant liquids. Application to moisture removal from air
- 1 March 2018
- Published by Elsevier in Energy and Buildings
- Vol. 162, 187-197
Electrospray technique to produce fine sprays of desiccant liquids. Application to moisture removal from air
- Open Access
- 20 January 2015
- Published by American Physical Society (APS) in Physical Review E
- Vol. 91 (1) , 013011
Periodic emission of droplets from an oscillating electrified meniscus of a low-viscosity, highly conductive liquid
The generation of identical droplets of controllable size in the micrometer range is a problem of much interest owing to the numerous technological applications of such droplets. This work reports an investigation of the regime of periodic emission of droplets from an electrified oscillating meniscus of a liquid of low viscosity and high electrical conductivity attached to the end of a capillary tube, which may be used to produce droplets more than ten times smaller than the diameter of the tube. To attain this periodic microdripping regime, termed axial spray mode II by Juraschek and Röllgen [R. Juraschek and F. W. Röllgen, Int. J. Mass Spectrom. 177, 1 (1998)], liquid is continuously supplied through the tube at a given constant flow rate, while a dc voltage is applied between the tube and a nearby counter electrode. The resulting electric field induces a stress at the surface of the liquid that stretches the meniscus until, in certain ranges of voltage and flow rate, it develops a ligament that eventually detaches, forming a single droplet, in a process that repeats itself periodically. While it is being stretched, the ligament develops a conical tip that emits ultrafine droplets, but the total mass emitted is practically contained in the main droplet. In the parametrical domain studied, we find that the process depends on two main dimensionless parameters, the flow rate nondimensionalized with the diameter of the tube and the capillary time, , and the electric Bond number , which is a nondimensional measure of the square of the applied voltage. The meniscus oscillation frequency made nondimensional with the capillary time, , is of order unity for very small flow rates and tends to decrease as the inverse of the square root of for larger values of this parameter. The product of the meniscus mean volume times the oscillation frequency is nearly constant. The characteristic length and width of the liquid ligament immediately before its detachment approximately scale as powers of the flow rate and depend only weakly on the applied voltage. The diameter of the main droplets nondimensionalized with the diameter of the tube satisfies , from mass conservation, while the electric charge of these droplets is about of the Rayleigh charge. At the minimum flow rate compatible with the periodic regimen, the dimensionless diameter of the droplets is smaller than one-tenth, which presents a way to use electrohydrodynamic atomization to generate droplets of highly conducting liquids in the micron-size range, in marked contrast with the cone-jet electrospray whose typical droplet size is in the nanometric regime for these liquids. In contrast with other microdripping regimes where the mass is emitted upon the periodic formation of a narrow capillary jet, the present regime gives one single droplet per oscillation, except for the almost massless fine aerosol emitted in the form of an electrospray.- 20 January 2015
- Published by American Physical Society (APS) in Physical Review E
- Vol. 91 (1) , 013011
Open AccessPeriodic emission of droplets from an oscillating electrified meniscus of a low-viscosity, highly conductive liquid
The generation of identical droplets of controllable size in the micrometer range is a problem of much interest owing to the numerous technological applications of such droplets. This work reports an investigation of the regime of periodic emission of droplets from an electrified oscillating meniscus of a liquid of low viscosity and high electrical conductivity attached to the end of a capillary tube, which may be used to produce droplets more than ten times smaller than the diameter of the tube. To attain this periodic microdripping regime, termed axial spray mode II by Juraschek and Röllgen [R. Juraschek and F. W. Röllgen, Int. J. Mass Spectrom. 177, 1 (1998)], liquid is continuously supplied through the tube at a given constant flow rate, while a dc voltage is applied between the tube and a nearby counter electrode. The resulting electric field induces a stress at the surface of the liquid that stretches the meniscus until, in certain ranges of voltage and flow rate, it develops a ligament that eventually detaches, forming a single droplet, in a process that repeats itself periodically. While it is being stretched, the ligament develops a conical tip that emits ultrafine droplets, but the total mass emitted is practically contained in the main droplet. In the parametrical domain studied, we find that the process depends on two main dimensionless parameters, the flow rate nondimensionalized with the diameter of the tube and the capillary time, , and the electric Bond number , which is a nondimensional measure of the square of the applied voltage. The meniscus oscillation frequency made nondimensional with the capillary time, , is of order unity for very small flow rates and tends to decrease as the inverse of the square root of for larger values of this parameter. The product of the meniscus mean volume times the oscillation frequency is nearly constant. The characteristic length and width of the liquid ligament immediately before its detachment approximately scale as powers of the flow rate and depend only weakly on the applied voltage. The diameter of the main droplets nondimensionalized with the diameter of the tube satisfies , from mass conservation, while the electric charge of these droplets is about of the Rayleigh charge. At the minimum flow rate compatible with the periodic regimen, the dimensionless diameter of the droplets is smaller than one-tenth, which presents a way to use electrohydrodynamic atomization to generate droplets of highly conducting liquids in the micron-size range, in marked contrast with the cone-jet electrospray whose typical droplet size is in the nanometric regime for these liquids. In contrast with other microdripping regimes where the mass is emitted upon the periodic formation of a narrow capillary jet, the present regime gives one single droplet per oscillation, except for the almost massless fine aerosol emitted in the form of an electrospray. - Open Access
- 1 December 2013
- Published by Elsevier in Journal of Aerosol Science
- Vol. 66, 193-208
Pulsating emission of droplets from an electrified meniscus
- 1 December 2013
- Published by Elsevier in Journal of Aerosol Science
- Vol. 66, 193-208
Open AccessPulsating emission of droplets from an electrified meniscus