Ilker Meric
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ilker Meric has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Geir Anton Johansen
University of Bergen
7 shared publications - Helge Egil Seime Pettersen
Haukeland University Hospital
7 shared publications - Kristian Smeland Ytre-Hauge
Department of Physics and Technology, University of Bergen, Bergen, Norway
6 shared publications John Mattingly
Department of Nuclear Engineering, North Carolina State University, Raleigh, USA
5 shared publications- Kyrre Skjerdal
Department of Computer Science, Electrical Engineering and Mathematical Sciences, Western Norway University of Applied Sciences, Inndalsveien 28, Bergen, Hordaland, 5063, NORWAY
5 shared publications Davorin Sudac
Ruder Bošković Institute, Zagreb, Croatia
4 shared publications
Latest Publications
- Open Access
- 28 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (12) , 125030
Fast proton transport and neutron production in proton therapy using Fourier neural operators
Objective . Real-time adaptive proton range verification systems based on produced neutrons require accurate information on their non-isotropic momentum distributions within seconds, for which general-purpose Monte Carlo (MC) methods are too computationally expensive. We therefore present a first study for a surrogate model based on Fourier neural operators (FNO) for fast prediction of angle- and energy-resolved proton transport and neutron production within proton therapy. Approach . We treat the phantom and the proton beam’s state as depth-evolving series, respectively of different materials, and of spatial, angular, and energy phase space density distributions. FNO models were trained to compute changes in proton distributions along with those of produced neutrons per unit of depth, and they were used auto-regressively to simulate the entire phantom. For training and evaluation, two datasets of 47 MC simulations featuring different primary intensities were produced. Simulated geometries were extracted from a thoracic CT scan as series of laterally homogeneous materials. Main Results . An average relative L 2 -norm error of 0.067 and 0.137 was achieved by the predicted proton and neutron distributions, respectively. This corresponded to an average spatial gamma passing rate (2 %, 2 mm) of 99.95 % and 99.40 % , and an average error in the mean of the longitudinal intensity distribution of 0.238 mm and 0.871 mm. Training with higher primary intensities improved neutron density metrics by up to 30 % . Inference over depths of 40 cm at a resolution of 0.5 mm required on average 23.17 s per beam. Significance . Our proton beam surrogate generates accurate phase space distributions of neutrons at MC-level accuracy within seconds, while demonstrating robust generalization with respect to irradiated geometry and beam characteristics. This first study is relevant for prototyping and operation of range verification systems and for other tasks such as neutron dose estimation, with methods being extendable to other kinds of secondary particles.
- 28 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (12) , 125030
Open AccessFast proton transport and neutron production in proton therapy using Fourier neural operators
Objective . Real-time adaptive proton range verification systems based on produced neutrons require accurate information on their non-isotropic momentum distributions within seconds, for which general-purpose Monte Carlo (MC) methods are too computationally expensive. We therefore present a first study for a surrogate model based on Fourier neural operators (FNO) for fast prediction of angle- and energy-resolved proton transport and neutron production within proton therapy. Approach . We treat the phantom and the proton beam’s state as depth-evolving series, respectively of different materials, and of spatial, angular, and energy phase space density distributions. FNO models were trained to compute changes in proton distributions along with those of produced neutrons per unit of depth, and they were used auto-regressively to simulate the entire phantom. For training and evaluation, two datasets of 47 MC simulations featuring different primary intensities were produced. Simulated geometries were extracted from a thoracic CT scan as series of laterally homogeneous materials. Main Results . An average relative L 2 -norm error of 0.067 and 0.137 was achieved by the predicted proton and neutron distributions, respectively. This corresponded to an average spatial gamma passing rate (2 %, 2 mm) of 99.95 % and 99.40 % , and an average error in the mean of the longitudinal intensity distribution of 0.238 mm and 0.871 mm. Training with higher primary intensities improved neutron density metrics by up to 30 % . Inference over depths of 40 cm at a resolution of 0.5 mm required on average 23.17 s per beam. Significance . Our proton beam surrogate generates accurate phase space distributions of neutrons at MC-level accuracy within seconds, while demonstrating robust generalization with respect to irradiated geometry and beam characteristics. This first study is relevant for prototyping and operation of range verification systems and for other tasks such as neutron dose estimation, with methods being extendable to other kinds of secondary particles.
- Open Access
- 4 July 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 238
Range verification in proton therapy with computational prompt gamma-ray spectroscopy: A Monte Carlo study
- 4 July 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 238
Open AccessRange verification in proton therapy with computational prompt gamma-ray spectroscopy: A Monte Carlo study
- 17 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (12) , 125011
Enhancing image quality in fast neutron-based range verification of proton therapy using a deep learning-based prior in LM-MAP-EM reconstruction
Objective. This study investigates the use of list-mode (LM) maximum a posteriori (MAP) expectation maximization (EM) incorporating prior information predicted by a convolutional neural network for image reconstruction in fast neutron (FN)-based proton therapy range verification. Approach. A conditional generative adversarial network (pix2pix) was trained on progressively noisier data, where detector resolution effects were introduced gradually to simulate realistic conditions. FN data were generated using Monte Carlo simulations of an 85 MeV proton pencil beam in a computed tomography-based lung cancer patient model, with range shifts emulating weight gain and loss. The network was trained to estimate the expected two-dimensional ground truth FN production distribution from simple back-projection images. Performance was evaluated using mean squared error, structural similarity index (SSIM), and the correlation between shifts in predicted distributions and true range shifts. Main results. Our results show that pix2pix performs well on noise-free data but suffers from significant degradation when detector resolution effects are introduced. Among the LM-MAP-EM approaches tested, incorporating a mean prior estimate into the reconstruction process improved performance, with LM-MAP-EM using a mean prior estimate outperforming naïve LM maximum likelihood EM (LM-MLEM) and conventional LM-MAP-EM with a smoothing quadratic energy function in terms of SSIM. Significance. Findings suggest that deep learning techniques can enhance iterative reconstruction for range verification in proton therapy. However, the effectiveness of the model is highly dependent on data quality, limiting its robustness in high-noise scenarios.
- 17 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (12) , 125011
Enhancing image quality in fast neutron-based range verification of proton therapy using a deep learning-based prior in LM-MAP-EM reconstruction
Objective. This study investigates the use of list-mode (LM) maximum a posteriori (MAP) expectation maximization (EM) incorporating prior information predicted by a convolutional neural network for image reconstruction in fast neutron (FN)-based proton therapy range verification. Approach. A conditional generative adversarial network (pix2pix) was trained on progressively noisier data, where detector resolution effects were introduced gradually to simulate realistic conditions. FN data were generated using Monte Carlo simulations of an 85 MeV proton pencil beam in a computed tomography-based lung cancer patient model, with range shifts emulating weight gain and loss. The network was trained to estimate the expected two-dimensional ground truth FN production distribution from simple back-projection images. Performance was evaluated using mean squared error, structural similarity index (SSIM), and the correlation between shifts in predicted distributions and true range shifts. Main results. Our results show that pix2pix performs well on noise-free data but suffers from significant degradation when detector resolution effects are introduced. Among the LM-MAP-EM approaches tested, incorporating a mean prior estimate into the reconstruction process improved performance, with LM-MAP-EM using a mean prior estimate outperforming naïve LM maximum likelihood EM (LM-MLEM) and conventional LM-MAP-EM with a smoothing quadratic energy function in terms of SSIM. Significance. Findings suggest that deep learning techniques can enhance iterative reconstruction for range verification in proton therapy. However, the effectiveness of the model is highly dependent on data quality, limiting its robustness in high-noise scenarios.
- Open Access
- 27 May 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (6) , 1050
Determining the Minimum Detection Limit of Methane Hydrate Using Associated Alpha Particle Technique
Methane hydrate is a crystalline compound in which methane is trapped within a water lattice under high-pressure, low-temperature conditions. Its presence in oceanic and permafrost sediments makes it a promising alternative energy source, but also a potential contributor to climate change. Accurate in situ detection remains a major challenge due to hydrate’s dispersed occurrence and the limitations of conventional geophysical methods. This study investigates the feasibility of using the associated alpha particle (AAP) technique for the direct detection of methane hydrate. A series of laboratory measurements was conducted on sand-based samples with varying levels of methane hydrate simulant. Using a 14 MeV neutron generator and a LaBr3 gamma detector, the 4.44 MeV carbon peak was monitored and calibrated against volumetric hydrate saturation. The minimum detection limit (MDL) was experimentally determined to be . Although the result is subject to high uncertainty, it provides a preliminary benchmark for evaluating the method’s sensitivity and highlights the potential of AAP-based gamma spectroscopy for in situ detection, especially when supported by higher neutron flux in future applications.- 27 May 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (6) , 1050
Open AccessDetermining the Minimum Detection Limit of Methane Hydrate Using Associated Alpha Particle Technique
Methane hydrate is a crystalline compound in which methane is trapped within a water lattice under high-pressure, low-temperature conditions. Its presence in oceanic and permafrost sediments makes it a promising alternative energy source, but also a potential contributor to climate change. Accurate in situ detection remains a major challenge due to hydrate’s dispersed occurrence and the limitations of conventional geophysical methods. This study investigates the feasibility of using the associated alpha particle (AAP) technique for the direct detection of methane hydrate. A series of laboratory measurements was conducted on sand-based samples with varying levels of methane hydrate simulant. Using a 14 MeV neutron generator and a LaBr3 gamma detector, the 4.44 MeV carbon peak was monitored and calibrated against volumetric hydrate saturation. The minimum detection limit (MDL) was experimentally determined to be . Although the result is subject to high uncertainty, it provides a preliminary benchmark for evaluating the method’s sensitivity and highlights the potential of AAP-based gamma spectroscopy for in situ detection, especially when supported by higher neutron flux in future applications. - 2 September 2024
- Published by Elsevier in Computer Physics Communications
- Vol. 306
Modeling and geometrization in PGNAA
- 2 September 2024
- Published by Elsevier in Computer Physics Communications
- Vol. 306
Modeling and geometrization in PGNAA
- 24 July 2024
- Published by Springer Nature
- p. 232-244
Image Reconstruction for Proton Therapy Range Verification via U-NETs
- 24 July 2024
- Published by Springer Nature
- p. 232-244
Image Reconstruction for Proton Therapy Range Verification via U-NETs
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07002
The Backscatter Gating method for time, energy, and position resolution characterization of long form factor organic scintillators
This work details a Compton-scattering-based methodology, referred to as Backscatter Gating (BSG), for characterizing the time, energy, and position resolutions of long form factor organic scintillators using a single, fairly minimal measurement setup. Such a method can ease the experimental burden in scenarios where many such scintillator elements may need to be individually characterized before assembly into a larger detector system. A thorough theoretical exploration of the systematic parameters is provided, and the BSG method is then demonstrated by a series of experimental measurements. This “complete” characterization via the BSG method is novel, having previously been used primarily for energy resolution characterization. The method also allows for determination of the assembled scintillator's technical attenuation length and provides a means of verifying the presence or absence of flaws within the scintillator or its optical coupling.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07002
The Backscatter Gating method for time, energy, and position resolution characterization of long form factor organic scintillators
This work details a Compton-scattering-based methodology, referred to as Backscatter Gating (BSG), for characterizing the time, energy, and position resolutions of long form factor organic scintillators using a single, fairly minimal measurement setup. Such a method can ease the experimental burden in scenarios where many such scintillator elements may need to be individually characterized before assembly into a larger detector system. A thorough theoretical exploration of the systematic parameters is provided, and the BSG method is then demonstrated by a series of experimental measurements. This “complete” characterization via the BSG method is novel, having previously been used primarily for energy resolution characterization. The method also allows for determination of the assembled scintillator's technical attenuation length and provides a means of verifying the presence or absence of flaws within the scintillator or its optical coupling.
- Open Access
- 25 April 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
A hybrid multi-particle approach to range assessment-based treatment verification in particle therapy
Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of $${1}\,\hbox {mm}$$ can be detected at relatively low proton intensities ( $$22.30(13)\times 10^{7}$$ protons/spot) when spatial information obtained through imaging of both particle species are usedsimultaneously. This study lays the foundation formulti-particledetection and imaging systems in the context of range verification in PT.- 25 April 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
Open AccessA hybrid multi-particle approach to range assessment-based treatment verification in particle therapy
Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of $${1}\,\hbox {mm}$$ can be detected at relatively low proton intensities ( $$22.30(13)\times 10^{7}$$ protons/spot) when spatial information obtained through imaging of both particle species are usedsimultaneously. This study lays the foundation formulti-particledetection and imaging systems in the context of range verification in PT. - Open Access
- 21 December 2022
- Published by Springer Nature in Research Square
A hybrid multi-particle approach to range assessment-based treatment verification in particle therapy
Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models. The results indicate that range shifts of 1 mm can be detected at relatively low proton intensities (6 million/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context range verification in PT.
- 21 December 2022
- Published by Springer Nature in Research Square
Open AccessA hybrid multi-particle approach to range assessment-based treatment verification in particle therapy
Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models. The results indicate that range shifts of 1 mm can be detected at relatively low proton intensities (6 million/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context range verification in PT.
- 11 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 738-744
C/O Logging by Using the Associated Alpha Particle Method: Proof of Principle
The possibility of using a fast neutron beam with the associated alpha particle (AAP) technique in conjunction with a specially designed probe for carbon-to-oxygen (C/O) nuclear well logging was investigated. Measurements were performed to show the influence of borehole fluid, iron casing, and the cement around the casing in the C/O analysis. Tests were conducted by using fast neutron activation analysis (FNAA), as the conventional approach for C/O measurements in well logging and by using AAP. Analyzed samples were made from quartz sand and graphite powder mixed in different C/O ratios characteristic for the oil-containing formations. Diesel fuel was used as a simulant of the borehole fluid. Monte Carlo (MC) simulations were conducted and the results were compared with the experimental data. In both tests, the linear relation between the measured and real C/O ratios was obtained, but when the FNAA was used, the linear relation was significantly influenced mainly by the presence of the borehole fluid. Contrary to FNAA, the AAP technique resulted in a significant reduction of the background signal coming from the borehole fluid.
- 11 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (4) , 738-744
C/O Logging by Using the Associated Alpha Particle Method: Proof of Principle
The possibility of using a fast neutron beam with the associated alpha particle (AAP) technique in conjunction with a specially designed probe for carbon-to-oxygen (C/O) nuclear well logging was investigated. Measurements were performed to show the influence of borehole fluid, iron casing, and the cement around the casing in the C/O analysis. Tests were conducted by using fast neutron activation analysis (FNAA), as the conventional approach for C/O measurements in well logging and by using AAP. Analyzed samples were made from quartz sand and graphite powder mixed in different C/O ratios characteristic for the oil-containing formations. Diesel fuel was used as a simulant of the borehole fluid. Monte Carlo (MC) simulations were conducted and the results were compared with the experimental data. In both tests, the linear relation between the measured and real C/O ratios was obtained, but when the FNAA was used, the linear relation was significantly influenced mainly by the presence of the borehole fluid. Contrary to FNAA, the AAP technique resulted in a significant reduction of the background signal coming from the borehole fluid.