XCXiaowei Chen

Xiaowei Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaowei Chen has a total of 121 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep Learning Polarity Measurements and SH Constraints for Focal Mechanism Estimation: A Utah FORGE Case Study

    by Ahmad Mohammadi, Xiaowei Chen, Nori Nakata, Pranshu Ratre

    Accurate determination of focal mechanisms for induced earthquakes and microseismic events is essential for characterizing rupture behavior, in situ stress states, and fracture network activation. Small-magnitude events are often recorded with low signal-to-noise ratios, making first-motion polarity measurement challenging. A combined Convolutional Neural Network–Transformer model is trained on 290,730 Southern California waveforms using noise augmentation and random arrival-time perturbation, achieving 96% polarity accuracy. Applied to the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) stage 3 stimulation (April 2022), the model predicts P-wave polarities and is tested on rotated transverse components to estimate SH polarity as a site-specific extension for the FORGE downhole array. Using 166 manually picked P polarities and 158 manually picked SH polarities from high-signal-quality FORGE events, the P and SH pick accuracies after quality-control thresholding are 98.0% (148/151) and 96.2% (125/130), respectively. A double-couple-constrained Bayesian inversion combines the retained polarities with amplitude ratios to obtain focal mechanism solutions. The workflow yields 717 high-quality focal mechanisms, dominated by strike-slip and normal faulting, showing complex faulting behavior across the stimulated volume.

  • Open Access

    Sequential Fracture Activation and Stress Evolution During EGS Stimulation at Utah FORGE Revealed by Waveform Cross‐Correlation

    by Richard Asirifi, Xiaowei Chen, Ahmad Mohammadi, Nori Nakata, Pranshu Ratre

    Mapping fracture networks in Enhanced Geothermal Systems (EGS) is essential for optimizing reservoir performance, yet complex fracture evolution during stimulation remains difficult to resolve. This study examines the evolution of microseismicity and fracture networks during stage 3 of the 2022 EGS stimulation at the Utah Frontier Observatory for Research in Geothermal Energy site. We map the fracture network represented by 20 clusters of seismic events identified by waveform similarities with cross‐correlation. We characterize their geometric properties such as strike, dip, length, and width, and analyze the time evolution of activated fractures. The results reveal a systematic fracture evolution: early activation of pre‐existing natural fractures, complex network development during peak injection, and continued activation of less favorably oriented fractures post‐injection. Magnitude calibration using the Principal Component Analysis of cross‐correlated waveforms improves relative amplitude measurements, refining estimations of the Gutenberg‐Richter b‐values with spatial variations in b‐values suggesting stress re‐distribution across the stimulated area. Analysis of the stress state of selected fractures further shows that fractures requiring higher excess pore pressure primarily activate at the end of injection and post‐injection, highlighting stress transfer due to pore pressure as a dominant triggering mechanism. These findings provide insights into fracture propagation, stress evolution, and seismic hazard assessment in EGS reservoirs.


  • Open Access

    From Seismic Signals to Urban Sensing: Leveraging Ambient Seismic Noise to Sense Human Activity Disruptions in Extreme Weather Events

    by Hao Tian, Heng Cai, Xiaowei Chen, Ahmad Mohammadi Ghanatghestani, Lawrence Arthur

    Understanding human behavioral responses to increasingly frequent natural disasters is critical for effective emergency response and urban resilience planning. Conventional social sensing data, such as mobile phone mobility or social media activity, have been widely used to monitor human behavior during extreme events but are often constrained by sampling bias, privacy concerns, and strong dependence on communication infrastructure that may fail during disasters. Human activities in urban environments generate ground vibrations that are continuously recorded by seismic sensors as ambient seismic noise. High-frequency ambient seismic noise provides a continuous, passive record of collective human activity that is independent of traditional communication infrastructure, with near-real-time availability and long-term historical coverage, making it a resilient and complementary data source for monitoring urban dynamics during disruptive events. Building on these advantages, this study evaluates the effectiveness of high-frequency seismic noise as an urban sensing modality using Winter Storm Uri in the Dallas–Fort Worth metropolitan area (Texas, USA) as a case study. By analyzing seismic signals from 13 stations across the DFW region, we quantified human-induced noise using spectral and displacement measures and validated the results with multi-source mobility and environmental datasets. The results reveal that seismic signals effectively capture the spatiotemporal patterns of human mobility during the storm event, including diurnal activity cycles, abrupt activity disruption during disaster, and gradual post-event recovery. The method's validity is supported by strong correlations with independent data sources, including mobile phone mobility data (r > 0.8), air traffic records, and meteorological observations. We also identify optimal frequency bands and spatial parameters for isolating human-related seismic signatures. In contrast, rural seismic signals were found to be more sensitive to environmental noise, particularly wind-induced vegetation movement. These findings underscore the emerging potential of leveraging existing seismic networks as a continuous, passive, and rapid urban sensing technique.

  • Open Access

    Hydraulic Fracturing Enhances Wastewater Disposal Seismicity in Eastern Oklahoma

    by Paul Ogwari, Jacob I. Walter, Xiaowei Chen, Isaac Woelfel, Andrew Thiel, Fernando Ferrer, Colin Brooks

    Between June 2019 and June 2022, 1192 earthquakes of magnitude ML 0.2–3.7 were recorded by the Oklahoma state seismic network near the town of Quinton in eastern Oklahoma. In our analysis of the area, we find that the earthquake sequence was plausibly enhanced due to adjacent hydraulic fracturing (HF) activity that broadened the influence of wastewater injection at a single disposal well. The initial cataloged seismicity indicated earthquake epicenters aligning as a northeast-striking fault south of northeast-striking mapped faults. However, careful relocation suggests the seismicity epicenters overlay a series of east–west-striking faults that are subparallel to the maximum-horizontal stress direction. We reanalyze the seismicity to establish the interaction between HF and wastewater disposal (WD) and their role in inducing seismicity in the area. We relocated earthquakes using a double-difference scheme and a local 1D velocity model to reveal three fault segments oriented in a northwest direction. The spatiotemporal occurrence of seismicity suggests increased pore pressure from the point of injection as the primary driver of seismicity. HF is found to “prime” the faults for the WD to induce and propagate seismicity. Furthermore, the preceding HF may have increased the vertical hydraulic connectivity, allowing a direct vertical propagation of fault permeability. The frequency-index method, which utilizes earthquake waveform frequency content, indicates fluid inclusion into the seismogenic faults during the fault reactivation by wastewater injection.


  • Open Access

    Sequential Fracture Activation and Stress Evolution During EGS Stimulation at Utah FORGE Revealed by Waveform Cross-Correlation

    by Richard Asirifi, Xiaowei Chen, Ahmad Mohammadi, Nori Nakata, Pranshu Ratre

    Mapping fracture networks in Enhanced Geothermal Systems (EGS) is essential for optimizing reservoir performance, yet their complex evolution during stimulation remains difficult to resolve. This study examines the evolution of microseismicity and fracture networks during stage 3 of the 2022 EGS stimulation at the Utah FORGE site. We map the fracture network represented by 20 clusters of seismic events identified by waveform similarities with cross-correlation. We characterize their geometric properties, such as strike, dip, length, and width, and analyze the time evolution of activated fractures. The results reveal a systematic fracture evolution: early activation of pre-existing natural fractures, complex network development during peak injection, and continued activation of less favorably oriented fractures post-injection. Magnitude calibration using the Principal Component Analysis (PCA) of cross-correlated waveforms improves relative amplitude measurements, refining estimations of the Gutenberg-Richter b-values with spatial variations in b-values suggesting stress redistribution across the stimulated area. Analysis of the stress state of selected fractures further shows that fractures requiring higher excess pore pressure primarily activate at the end of injection and post-injection, highlighting stress transfer due to pore pressure as a dominant triggering mechanism. These findings provide insights into fracture propagation, stress evolution, and seismic hazard assessment in EGS reservoirs.

  • Top Cited Papers

    Overview of the SCEC/USGS Community Stress Drop Validation Study Using the 2019 Ridgecrest Earthquake Sequence

    by Rachel E. Abercrombie, Annemarie Baltay, Shanna Chu, Taka’aKi Taira, Dino Bindi, Oliver S. Boyd, Xiaowei Chen, Elizabeth S. Cochran, Emma Devin, Douglas Dreger, et al.

    We present initial findings from the ongoing Community Stress Drop Validation Study to compare spectral stress-drop estimates for earthquakes in the 2019 Ridgecrest, California, sequence. This study uses a unified dataset to independently estimate earthquake source parameters through various methods. Stress drop, which denotes the change in average shear stress along a fault during earthquake rupture, is a critical parameter in earthquake science, impacting ground motion, rupture simulation, and source physics. Spectral stress drop is commonly derived by fitting the amplitude-spectrum shape, but estimates can vary substantially across studies for individual earthquakes. Sponsored jointly by the U.S. Geological Survey and the Statewide (previously, Southern) California Earthquake Center our community study aims to elucidate sources of variability and uncertainty in earthquake spectral stress-drop estimates through quantitative comparison of submitted results from independent analyses. The dataset includes nearly 13,000 earthquakes ranging from M 1 to 7 during a two-week period of the 2019 Ridgecrest sequence, recorded within a 1° radius. In this article, we report on 56 unique submissions received from 20 different groups, detailing spectral corner frequencies (or source durations), moment magnitudes, and estimated spectral stress drops. Methods employed encompass spectral ratio analysis, spectral decomposition and inversion, finite-fault modeling, ground-motion-based approaches, and combined methods. Initial analysis reveals significant scatter across submitted spectral stress drops spanning over six orders of magnitude. However, we can identify between-method trends and offsets within the data to mitigate this variability. Averaging submissions for a prioritized subset of 56 events shows reduced variability of spectral stress drop, indicating overall consistency in recovered spectral stress-drop values.


  • Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

    by Xiaowei Chen, Qimin Wu, Colin Pennington

    Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. We also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.


  • Comparison of EGF Methods for Ridgecrest Sequence: Can EGFs Help Resolve Ambiguity in Isolating Source Spectra?

    by Rachel E. Abercrombie, Xiaowei Chen, Yihe Huang, Shanna Chu

    The spectral stress drop is a popular parameter for the simple quantification and characterization of an earthquake source and its expected seismic radiation, enabling investigation of earthquake spatial and temporal variability for larger numbers of events. In addition, spectral measurements are one of the few possible for earthquake characterization and hazard prediction in regions of low seismicity. However, spectral stress-drop estimates are uncertain, especially as recorded earthquakes may be too complex to characterize ideally with a single parameter. Empirical Green’s function (EGF) approaches to isolate the earthquake source are widely regarded as one of the best for individual analysis of well-recorded earthquakes. However, analysis decisions related to the selection of stations, EGFs, time windows, frequency bandwidth, and source models can cause discrepancies in resulting estimates of the source spectrum, source time function, and source parameters. We present results following one well-developed EGF approach, and compare it with those from three other independent methods applied to earthquakes in the 2019 Ridgecrest, California, earthquake, sequence selected for the Southern California Earthquake Center /U.S. Geological Survey Community Stress Drop Validation Study. The common data set consists of two weeks of earthquakes from the 2019 Ridgecrest earthquake sequence, including nearly 13,000 events of M 1 and greater, recorded on stations within 100 km. We obtain estimates of corner frequency and spectral stress drop for 75 earthquakes (M 2.2–4.6) and find varying degrees of similarity among studies. We investigate four events in detail (M 2.7–4.1) and find that we obtain consistent results when the sources are relatively simple. Multiple EGFs produce good ratios and source time functions at stations with good azimuthal distribution. This suggests that there is a role for such approaches to resolve the inherent ambiguity in larger scale inversions between source scaling and attenuation and site effects.


  • Effect of Time Window and Spectral Measurement Options on Empirical Green’s Function Analysis Using DAS Array and Seismic Stations

    by Xiaowei Chen, Jiuxun Yin, Colin Pennington, Qimin Wu, Zhongwen Zhan

    The recorded seismic waveform is a convolution of event source term, path term, and station term. Removing high-frequency attenuation due to path effect is a challenging problem. Empirical Green’s function (EGF) method uses nearly collocated small earthquakes to correct the path and station terms for larger events recorded at the same station. However, this method is subject to variability due to many factors. We focus on three events that were well recorded by the seismic network and a rapid response distributed acoustic sensing (DAS) array. Using a suite of high-quality EGF events, we assess the influence of time window, spectral measurement options, and types of data on the spectral ratio and relative source time function (RSTF) results. Increased number of tapers (from 2 to 16) tends to increase the measured corner frequency and reduce the source complexity. Extended long time window (e.g., 30 s) tends to produce larger variability of corner frequency. The multitaper algorithm that simultaneously optimizes both target and EGF spectra produces the most stable corner-frequency measurements. The stacked spectral ratio and RSTF from the DAS array are more stable than two nearby seismic stations, and are comparable to stacked results from the seismic network, suggesting that DAS array has strong potential in source characterization.


  • SCEC/USGS Community Stress-Drop Validation Study: How Spectral Fitting Approaches Influence Measured Source Parameters

    by Elizabeth S. Cochran, Annemarie Baltay, Shanna Chu, Rachel E. Abercrombie, Dino Bindi, Xiaowei Chen, Grace A. Parker, Colin Pennington, Peter M. Shearer, Daniel T. Trugman

    Spectral source parameters used to estimate an earthquake’s stress drop (Δσ) can vary significantly across measurement approaches. The Statewide California Earthquake Center/U.S. Geological Survey Community Stress-Drop Validation Study was initiated to compare source parameter estimates, focusing initially on a dataset from the 2019 Ridgecrest earthquake sequence. As part of that validation effort, here we focus on one potential source of uncertainty: whether spectral fitting approaches alone, applied to a common set of spectra from the 2019 Ridgecrest sequence result in different source parameter estimates. By using a common set of benchmark spectra analyzed across a consistent frequency band of 1–40 Hz, we eliminate many sources of variability. A subgroup of validation study participants volunteered to estimate the low-frequency displacement (Ω0) and corner frequency (fc) by fitting a smooth function to benchmark displacement spectra. Participants used linear- or log-sampled spectra, assumed a Brune or Boatwright spectral model, and applied different misfit criteria. We compare 17 approaches used to estimate Ω0, fc, and Δσ for 54 earthquake spectra. Our results reveal that 35% of events have Δσ estimates within a factor of two, whereas others exhibit variations exceeding an order of magnitude. The variability in Ω0 and fc can largely be attributed to whether a spectrum is consistent with the smooth function of an idealized simple crack model. The trade-off between Ω0 and fc may be more pronounced when using linearly sampled spectra, as higher frequency spectral bumps control the fits. As expected, methods that assumed a Boatwright model tended to have lower Ω0 and somewhat higher fc compared to those assuming a Brune model, although resulting Δσ estimates are similar. When compared to the overall validation study results, the fitting approach alone may account for between 5% and 90% (25% on average) of the total variability in spectral Δσ.