Emoke Lorincz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emoke Lorincz has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Gábor Erdei
Budapest University of Technology and Economics
25 shared publications Ferenc Ujhelyi
18 shared publicationsPál Koppa
Budapest Univ. of Technology and Economics (Hungary)
7 shared publicationsBalázs Játékos
6 shared publicationsF. Ujhelyi
Budapest University of Technology and Economics (BME), Budapest, Hungary
6 shared publicationsP.S. Ramanujam
Optics and Fluid Dynamics Department, Risø National Laboratory, DK-4000 Roskilde, Denmark
5 shared publications
Latest Publications
- 1 January 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 769, 59-64
Investigation of photon detection probability dependence of SPADnet-I digital photon counter as a function of angle of incidence, wavelength and polarization
- 1 January 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 769, 59-64
Investigation of photon detection probability dependence of SPADnet-I digital photon counter as a function of angle of incidence, wavelength and polarization
- 8 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9129, 912913-912913-11
SPADnet: a fully digital, scalable, and networked photonic component for time-of-flight PET applications
- 8 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9129, 912913-912913-11
SPADnet: a fully digital, scalable, and networked photonic component for time-of-flight PET applications
- Open Access
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 734, 122-126
SPADnet: Embedded coincidence in a smart sensor network for PET applications
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 734, 122-126
Open AccessSPADnet: Embedded coincidence in a smart sensor network for PET applications
- 1 December 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (12) , C12026
First characterization of the SPADnet sensor: a digital silicon photomultiplier for PET applications
Silicon Photomultipliers have the ability to replace photomultiplier tubes when used as light sensors in scintillation gamma-ray detectors. Their timing properties, compactness, and magnetic field compatibility make them interesting for use in Time-of-Flight Magnetic Resonance Imaging compatible Positron Emission Tomography. In this paper, we present a new fully digital Single Photon Avalanche Diode (SPAD) based detector fabricated in CMOS image sensor technology. It contains 16x8 pixels with a pitch of 610x571.2 μm2. The Dark Count Rate and the Photon Detection Probability of each SPAD has been measured and the homogeneity of these parameters in the entire 92000 SPAD array is shown. The sensor has been optically coupled to a single LYSO needle and a LYSO array. The scintillator crystal was irradiated with several gamma sources and the resulting images and energy spectra are presented.
- 1 December 2013
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (12) , C12026
First characterization of the SPADnet sensor: a digital silicon photomultiplier for PET applications
Silicon Photomultipliers have the ability to replace photomultiplier tubes when used as light sensors in scintillation gamma-ray detectors. Their timing properties, compactness, and magnetic field compatibility make them interesting for use in Time-of-Flight Magnetic Resonance Imaging compatible Positron Emission Tomography. In this paper, we present a new fully digital Single Photon Avalanche Diode (SPAD) based detector fabricated in CMOS image sensor technology. It contains 16x8 pixels with a pitch of 610x571.2 μm2. The Dark Count Rate and the Photon Detection Probability of each SPAD has been measured and the homogeneity of these parameters in the entire 92000 SPAD array is shown. The sensor has been optically coupled to a single LYSO needle and a LYSO array. The scintillator crystal was irradiated with several gamma sources and the resulting images and energy spectra are presented.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1-4
High probability crystal pin identification in scintillator matrix-based PET detector with a prototype digital SiPM
We evaluated spatial resolution performance of a 1.51×1.51×10mm 3 LYSO:Ce pin based experimental PET module coupled to a prototype, digital silicon photomultiplier device (digital SiPM). Utilizing the spatial oversampling capability of our digital SiPM we were able to achieve high-probability crystal identification. Position histograms were generated using a modified center of gravity algorithm (COG). We found that the distributions of estimated positions of single crystal pins in neighboring positions are separated at least by 15σ. We also tested our digital SiPM with a 7×3 element scintillator array. From the acquired 2D position histogram the pins can be easily identified by using constant pitch grid segmentation. Analysis of average light distribution of a single crystal pin was also performed. The root means square (RMS) radius of the light spots from consecutive measurements were to be found very similar (r RMS =1.106±0.034 mm).
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1-4
High probability crystal pin identification in scintillator matrix-based PET detector with a prototype digital SiPM
We evaluated spatial resolution performance of a 1.51×1.51×10mm 3 LYSO:Ce pin based experimental PET module coupled to a prototype, digital silicon photomultiplier device (digital SiPM). Utilizing the spatial oversampling capability of our digital SiPM we were able to achieve high-probability crystal identification. Position histograms were generated using a modified center of gravity algorithm (COG). We found that the distributions of estimated positions of single crystal pins in neighboring positions are separated at least by 15σ. We also tested our digital SiPM with a 7×3 element scintillator array. From the acquired 2D position histogram the pins can be easily identified by using constant pitch grid segmentation. Analysis of average light distribution of a single crystal pin was also performed. The root means square (RMS) radius of the light spots from consecutive measurements were to be found very similar (r RMS =1.106±0.034 mm).
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1-5
SPADnet: A fully digital, networked approach to MRI compatible PET systems based on deep-submicron CMOS technology
This paper is the first comprehensive presentation of the SPADnet concept. SPADnet is a fully digital, networked MRI compatible time-of-flight PET system, exploiting the speed and integration density of deep-submicron CMOS technologies. The core enabling technologies of SPADnet are a sensor device comprising an array of 8×16 pixels, each composed of 4 mini-SiPMs with in situ time-to-digital conversion, a multi-ring network to filter, carry, and process data produced by the sensor devices at 2Gbps, and a 130nm CMOS process enabling mass-production of photonic modules that are optically interfaced to scintillator crystals. The SPADnet photonic modules comprise a matrix of tightly packed sensor devices; each module is networked in multiple rings, where coincidence pairs are identified and readily used in reconstruction algorithms, enabling scalable, MRI compatible pre-clinical PET systems for multi-modal imaging.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 1-5
SPADnet: A fully digital, networked approach to MRI compatible PET systems based on deep-submicron CMOS technology
This paper is the first comprehensive presentation of the SPADnet concept. SPADnet is a fully digital, networked MRI compatible time-of-flight PET system, exploiting the speed and integration density of deep-submicron CMOS technologies. The core enabling technologies of SPADnet are a sensor device comprising an array of 8×16 pixels, each composed of 4 mini-SiPMs with in situ time-to-digital conversion, a multi-ring network to filter, carry, and process data produced by the sensor devices at 2Gbps, and a 130nm CMOS process enabling mass-production of photonic modules that are optically interfaced to scintillator crystals. The SPADnet photonic modules comprise a matrix of tightly packed sensor devices; each module is networked in multiple rings, where coincidence pairs are identified and readily used in reconstruction algorithms, enabling scalable, MRI compatible pre-clinical PET systems for multi-modal imaging.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2555-2558
Enhanced model of quantum efficiency for the optical simulation of photodetectors
Photodetector manufacturers provide characteristic data of their devices, such as quantum efficiency, in the form of diagrams as a function of wavelength. Though these are appropriate in most measuring situations, for simulation purposes their application is not straightforward. We present a method to convert quantum efficiency into a model that can be built into simulation tools generally used for the design of PET detectors. The model parameters are determined from the measurement of the wavelength dependent reflectance of the photo-sensitive detector surface. The effect of how the new quantum efficiency model influences the results of simulations is presented on a simple detector arrangement.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2555-2558
Enhanced model of quantum efficiency for the optical simulation of photodetectors
Photodetector manufacturers provide characteristic data of their devices, such as quantum efficiency, in the form of diagrams as a function of wavelength. Though these are appropriate in most measuring situations, for simulation purposes their application is not straightforward. We present a method to convert quantum efficiency into a model that can be built into simulation tools generally used for the design of PET detectors. The model parameters are determined from the measurement of the wavelength dependent reflectance of the photo-sensitive detector surface. The effect of how the new quantum efficiency model influences the results of simulations is presented on a simple detector arrangement.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3746-3750
Evaluation of light extraction from PET detector modules using gamma equivalent UV excitation
Monolithic scintillator-based PET detector modules offer depth of interaction capability and lower price relative to conventional pixelated crystal detectors. However, making such constructions poses several problems that affect light extraction efficiency and accuracy of position determination. In this work we examine potential detector geometries proposed to solve these problems. The geometries were tested by our novel measurement method that utilizes point-like excitation of the scintillator. With the applied methods we successfully increased the light extraction with a factor of two relative to a conventional monolithic PET detector. The measurements were compared to results of complete optical CAD models of the investigated arrangements. We concluded that our optical CAD tool can be used to further optimize the current constructions.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3746-3750
Evaluation of light extraction from PET detector modules using gamma equivalent UV excitation
Monolithic scintillator-based PET detector modules offer depth of interaction capability and lower price relative to conventional pixelated crystal detectors. However, making such constructions poses several problems that affect light extraction efficiency and accuracy of position determination. In this work we examine potential detector geometries proposed to solve these problems. The geometries were tested by our novel measurement method that utilizes point-like excitation of the scintillator. With the applied methods we successfully increased the light extraction with a factor of two relative to a conventional monolithic PET detector. The measurements were compared to results of complete optical CAD models of the investigated arrangements. We concluded that our optical CAD tool can be used to further optimize the current constructions.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 59 (3) , 507-512
Optimized Light Sharing Module for High Resolution PET Block Detectors
Controlled deflection of light cones from excited crystal pins has been realized in a positron emission tomography (PET) block detector that allows the enhancement of spatial resolution. The new light sharing module consists of special double prism units optically coupled to a continuous light guide. Slope angle in the prism units can be optimized for each pin in the array. We present well correlating results of light distribution measurements and simulations of single crystal pins with double prisms with different slope angles. First test results of spatial resolution improvement with optimized pixels of a block detector are also presented.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 59 (3) , 507-512
Optimized Light Sharing Module for High Resolution PET Block Detectors
Controlled deflection of light cones from excited crystal pins has been realized in a positron emission tomography (PET) block detector that allows the enhancement of spatial resolution. The new light sharing module consists of special double prism units optically coupled to a continuous light guide. Slope angle in the prism units can be optimized for each pin in the array. We present well correlating results of light distribution measurements and simulations of single crystal pins with double prisms with different slope angles. First test results of spatial resolution improvement with optimized pixels of a block detector are also presented.
- 23 April 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8439, 84391R-84391R-10
Characterization of MRI-compatible PET detector modules by optical excitation of the scintillator material
In the field of biomedical imaging there is a strong interest in combining modalities of positron emission tomography (PET) and magnetic resonance imaging (MRI). An MRI-compatible PET detector module has to be insensitive to the magnetic field that is why it needs to incorporate avalanche photodiodes (APD) or silicon photomultipliers (SiPM). We propose a new purely optical characterization method for these devices where no nuclear source is needed. In our method we use LED sources for both the direct illumination of silicon sensors and fluorescent excitation of the scintillator material. With this method we can measure the response characteristic and uniformity of pixels in sensor arrays as well as the optical cross-talk between neighboring pixels. In the same experimental setup we can also emulate the pulse response of the detector module (i.e. light-spread over the sensor array from a point source in the scintillator material). We present the detailed construction of the experimental setup and analyze the benefits and drawbacks of this method compared to the nuclear measurements. The viability of the idea is proven through the characterization of a SiPM array and a block detector module based on it.
- 23 April 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8439, 84391R-84391R-10
Characterization of MRI-compatible PET detector modules by optical excitation of the scintillator material
In the field of biomedical imaging there is a strong interest in combining modalities of positron emission tomography (PET) and magnetic resonance imaging (MRI). An MRI-compatible PET detector module has to be insensitive to the magnetic field that is why it needs to incorporate avalanche photodiodes (APD) or silicon photomultipliers (SiPM). We propose a new purely optical characterization method for these devices where no nuclear source is needed. In our method we use LED sources for both the direct illumination of silicon sensors and fluorescent excitation of the scintillator material. With this method we can measure the response characteristic and uniformity of pixels in sensor arrays as well as the optical cross-talk between neighboring pixels. In the same experimental setup we can also emulate the pulse response of the detector module (i.e. light-spread over the sensor array from a point source in the scintillator material). We present the detailed construction of the experimental setup and analyze the benefits and drawbacks of this method compared to the nuclear measurements. The viability of the idea is proven through the characterization of a SiPM array and a block detector module based on it.