Eric Laciar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Laciar has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Raimon Jane
Department of Automatic Control, Universitat Politècnica de Catalunya-BarcelonaTech (UPC), 08028 Barcelona, Spain
15 shared publications - Pablo. F. Diez
Gabinete de Tecnología Médica (GATEME), Facultad de Ingeniería, Universidad Nacional de San Juan, San Juan, Argentina
13 shared publications - Abel Torres
ORCID http://orcid.org
10 shared publications - Raúl Correa
Gabinete de Tecnología Médica, Facultad de Ingeniería, Universidad Nacional de San Juan (UNSJ), San Juan, Argentina
7 shared publications Vicente Mut
Universidad Nacional de San Juan
7 shared publicationsEnrique Avila
6 shared publications
Latest Publications
- 8 July 2020
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (4) , 555-563
A New Algorithm to Score Apnea/Hypopnea Events based on Respiratory Effort Signal and Oximeter Sensors
- 8 July 2020
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (4) , 555-563
A New Algorithm to Score Apnea/Hypopnea Events based on Respiratory Effort Signal and Oximeter Sensors
- 1 October 2019
- Published by Springer Nature
- p. 1502-1509
Evaluation of Respiratory Signal Record Based on Impedance Pneumography and Textile Electrodes
- 1 October 2019
- Published by Springer Nature
- p. 1502-1509
Evaluation of Respiratory Signal Record Based on Impedance Pneumography and Textile Electrodes
- 1 October 2019
- Published by Springer Nature
- p. 1066-1072
Design and Implementation of a Multifunctional Myoelectric Control for Upper Limb Prostheses
- 1 October 2019
- Published by Springer Nature
- p. 1066-1072
Design and Implementation of a Multifunctional Myoelectric Control for Upper Limb Prostheses
- 1 October 2019
- Published by Springer Nature
- p. 1171-1177
Development of a Serious Game Controlled by Myoelectric Signals
- 1 October 2019
- Published by Springer Nature
- p. 1171-1177
Development of a Serious Game Controlled by Myoelectric Signals
- 30 May 2018
- Published by Springer Nature
- p. 133-137
SAHS Patients’ Classification Based on Oximetry and Respiratory Effort Signal: An Alternative Method
- 30 May 2018
- Published by Springer Nature
- p. 133-137
SAHS Patients’ Classification Based on Oximetry and Respiratory Effort Signal: An Alternative Method
- 7 April 2017
- Published by Springer Nature
- p. 496-499
VCG and ECG indexes for classification of patients with Myocardial Infarction
- 7 April 2017
- Published by Springer Nature
- p. 496-499
VCG and ECG indexes for classification of patients with Myocardial Infarction
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Diseño de una mano artificial antropomórfica para aplicaciones protésicas
This paper presents the design of a prototype of an artificial anthropomorphic prosthetic hand that attempts to reproduce the appearance and movements of the human hand. Motivator's goals for the design were functionality, aesthetics and economics. Regarding the functionality, the hand can be configured with three grasping patterns to handle objects of different shapes and sizes. It has five fingers, where the index, middle, ring and little fingers, have three phalanges that facilitate their flexion and extension. The thumb has two phalanges to perform flexion and extension movements. The thumb was designed with an independent mechanism that allows its opposition to the rest of the fingers. The hand opening and closing is performed by DC motors located into the palm and commanded with an Arduino board. The fingers have force and flex sensors that provide feedback to control the hands movements. With respect to aesthetics, we intended to mimic the appearance, in terms of size and shape, of an adult man hand without harming its functionality. Finally, the economic aspect was accomplished using materials and other parts that were easily accessible and inexpensive. The construction of the prototype was performed by plastic modelling technology such as 3D printers.
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Diseño de una mano artificial antropomórfica para aplicaciones protésicas
This paper presents the design of a prototype of an artificial anthropomorphic prosthetic hand that attempts to reproduce the appearance and movements of the human hand. Motivator's goals for the design were functionality, aesthetics and economics. Regarding the functionality, the hand can be configured with three grasping patterns to handle objects of different shapes and sizes. It has five fingers, where the index, middle, ring and little fingers, have three phalanges that facilitate their flexion and extension. The thumb has two phalanges to perform flexion and extension movements. The thumb was designed with an independent mechanism that allows its opposition to the rest of the fingers. The hand opening and closing is performed by DC motors located into the palm and commanded with an Arduino board. The fingers have force and flex sensors that provide feedback to control the hands movements. With respect to aesthetics, we intended to mimic the appearance, in terms of size and shape, of an adult man hand without harming its functionality. Finally, the economic aspect was accomplished using materials and other parts that were easily accessible and inexpensive. The construction of the prototype was performed by plastic modelling technology such as 3D printers.
- Open Access
- 1 April 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 705 (1) , 012039
Development of an apnea detection algorithm based on temporal analysis of thoracic respiratory effort signal
This work describes the design of an algorithm for detecting apnea episodes, based on analysis of thorax respiratory effort signal. Inspiration and expiration time, and range amplitude of respiratory cycle were evaluated. For range analysis the standard deviation statistical tool was used over respiratory signal temporal windows. The validity of its performance was carried out in 8 records of Apnea-ECG database that has annotations of apnea episodes. The results are: sensitivity (Se) 73%, specificity (Sp) 83%. These values can be improving eliminating artifact of signal records.
- 1 April 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 705 (1) , 012039
Open AccessDevelopment of an apnea detection algorithm based on temporal analysis of thoracic respiratory effort signal
This work describes the design of an algorithm for detecting apnea episodes, based on analysis of thorax respiratory effort signal. Inspiration and expiration time, and range amplitude of respiratory cycle were evaluated. For range analysis the standard deviation statistical tool was used over respiratory signal temporal windows. The validity of its performance was carried out in 8 records of Apnea-ECG database that has annotations of apnea episodes. The results are: sensitivity (Se) 73%, specificity (Sp) 83%. These values can be improving eliminating artifact of signal records.
- 1 April 2016
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 71, 128-134
Patient non-specific algorithm for seizures detection in scalp EEG
- 1 April 2016
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 71, 128-134
Patient non-specific algorithm for seizures detection in scalp EEG
- 3 January 2016
- Published by Springer Nature
- p. 60-63
Development of Portable Device to Measure Respiratory Activity Based on Impedance Pneumography
- 3 January 2016
- Published by Springer Nature
- p. 60-63
Development of Portable Device to Measure Respiratory Activity Based on Impedance Pneumography