József Simon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
József Simon has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- László Gergely Vigh
BME, Department of Structural Engineering, Budapest, Hungary
2 shared publications - Adrián Horváth
Ipari professzor, Főmterv Zrt., Budapest; Budapesti Műszaki és Gazdaságtudományi Egyetem Hidak és Szerkezetek Tanszék, Budapest, Hungary
1 shared publication Gergely L. Vigh
1 shared publication- Katalin Bagi
Department of Structural Mechanics, Faculty of Civil Engineering, Budapest University of Technology and Economics, Budapest, Hungary
1 shared publication László Gergely Vigh
Department of Structural Engineering, Budapest University of Technology and Economics, Budapest, Hungary
1 shared publication- Pál Pusztai
CÉH Planning, Developing and Consulting Inc
1 shared publication
Latest Publications
- 12 May 2017
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (10) , 1758-1786
Seismic Reliability Assessment of Typical Road Bridges in Hungary
Prior to modern seismic codes, several road bridges were not designed for earthquakes in many moderate seismic regions. The seismic performance of these bridges is questionable. A portfolio of 30 non-seismically designed bridges is compiled for seismic reliability assessment. Fragility analysis is conducted, and the reliability of each structure is determined considering typical moderate seismic areas. The study shows that slab and multi-girder bridges with elastomeric bearings perform worse, whereas girder bridges with conventional bearings and multi-girder bridges with monolithic joints have better behavior. It is also shown that seismic design per Eurocode 8 leads to a reliability index of ~2.
- 12 May 2017
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (10) , 1758-1786
Seismic Reliability Assessment of Typical Road Bridges in Hungary
Prior to modern seismic codes, several road bridges were not designed for earthquakes in many moderate seismic regions. The seismic performance of these bridges is questionable. A portfolio of 30 non-seismically designed bridges is compiled for seismic reliability assessment. Fragility analysis is conducted, and the reliability of each structure is determined considering typical moderate seismic areas. The study shows that slab and multi-girder bridges with elastomeric bearings perform worse, whereas girder bridges with conventional bearings and multi-girder bridges with monolithic joints have better behavior. It is also shown that seismic design per Eurocode 8 leads to a reliability index of ~2.
- 25 March 2017
- Published by Techno-Press in Earthquakes and Structures
- Vol. 12 (3) , 375-388
Parametric seismic evaluation of highway overpass bridges in moderate seismic areas
- 25 March 2017
- Published by Techno-Press in Earthquakes and Structures
- Vol. 12 (3) , 375-388
Parametric seismic evaluation of highway overpass bridges in moderate seismic areas
- 23 June 2016
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 14 (11) , 3125-3150
Seismic fragility assessment of integral precast multi-span bridges in areas of moderate seismicity
- 23 June 2016
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 14 (11) , 3125-3150
Seismic fragility assessment of integral precast multi-span bridges in areas of moderate seismicity
- Open Access
- 1 January 2015
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 59 (2) , 109-122
Application and Assessment of Equivalent Linear Analysis Method for Conceptual Seismic Retrofit Design of Háros M0 Highway Bridge
In this study, seismic performance of the existing M0 Háros Highway Bridge in Hungary is evaluated. The large-span bridge is designed with minimal consideration of seismic actions, seismic resistance of certain piers, bearings and pile foundations is not adequate. Eight different demand mitigation methods are evaluated considering quasi-elastic configurations as well as non-linear systems adopted with non-linear anti-seismic devices (NLASD). To accelerate the preliminary design phase, an equivalent linear analysis (ELA) methodology is worked out. Keeping in mind the limitations of the ELA method, non-linear timehistory analysis (NLTHA) is also applied for the retrofitted configuration for validation purposes. Comparison of the two methods shows that the ELA method gives the designer adequate, still conservative results for optimal retrofit decisions.
- 1 January 2015
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 59 (2) , 109-122
Open AccessApplication and Assessment of Equivalent Linear Analysis Method for Conceptual Seismic Retrofit Design of Háros M0 Highway Bridge
In this study, seismic performance of the existing M0 Háros Highway Bridge in Hungary is evaluated. The large-span bridge is designed with minimal consideration of seismic actions, seismic resistance of certain piers, bearings and pile foundations is not adequate. Eight different demand mitigation methods are evaluated considering quasi-elastic configurations as well as non-linear systems adopted with non-linear anti-seismic devices (NLASD). To accelerate the preliminary design phase, an equivalent linear analysis (ELA) methodology is worked out. Keeping in mind the limitations of the ELA method, non-linear timehistory analysis (NLTHA) is also applied for the retrofitted configuration for validation purposes. Comparison of the two methods shows that the ELA method gives the designer adequate, still conservative results for optimal retrofit decisions.
- 31 December 2014
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (4) , 457-475
Discrete Element Analysis of the Minimum Thickness of Oval Masonry Domes
This study focuses on domes the ground plan of which, instead of the more common circular shape, is an oval, and aims at finding the minimally necessary uniform wall thickness for domes of different geometries loaded by their selfweight. The discrete element code 3DEC was applied because of its capability of simulating the collapse mechanisms of masonry structures. Results on the minimal wall thickness, corresponding masonry volume and failure mechanisms for different dome geometries are presented. Three ranges of the friction coefficient were found. For very low frictional resistance collapse happens with pure frictional sliding, for any arbitrarily large wall thickness. In the range of relatively high (i.e., realistic) friction coefficients the structure collapses without any sliding if the wall is not sufficiently thick, and in the observed range of the friction coefficient the necessary wall thickness is nearly insensitive to its value (collapse initiates with hinging cracks only). Between the two domains an intermediate behavior was found: combined cracking and sliding collapse modes occur for insufficient wall thickness, and the minimal thickness strongly depends on the friction coefficient. The critical and transitional friction coefficients separating the failure modes were determined for different eccentricities of the groundplan.
- 31 December 2014
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (4) , 457-475
Discrete Element Analysis of the Minimum Thickness of Oval Masonry Domes
This study focuses on domes the ground plan of which, instead of the more common circular shape, is an oval, and aims at finding the minimally necessary uniform wall thickness for domes of different geometries loaded by their selfweight. The discrete element code 3DEC was applied because of its capability of simulating the collapse mechanisms of masonry structures. Results on the minimal wall thickness, corresponding masonry volume and failure mechanisms for different dome geometries are presented. Three ranges of the friction coefficient were found. For very low frictional resistance collapse happens with pure frictional sliding, for any arbitrarily large wall thickness. In the range of relatively high (i.e., realistic) friction coefficients the structure collapses without any sliding if the wall is not sufficiently thick, and in the observed range of the friction coefficient the necessary wall thickness is nearly insensitive to its value (collapse initiates with hinging cracks only). Between the two domains an intermediate behavior was found: combined cracking and sliding collapse modes occur for insufficient wall thickness, and the minimal thickness strongly depends on the friction coefficient. The critical and transitional friction coefficients separating the failure modes were determined for different eccentricities of the groundplan.