Seth Sims
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seth Sims has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- David Stiven Campo
Centers for Disease Control and Prevention
9 shared publications - Alex Zelikovsky
Georgia State University
7 shared publications Yury Khudyakov
Molecular Epidemiology and Bioinformatics Laboratory, Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
6 shared publications- Yury Khudyakov
Centers for Disease Control and Prevention
6 shared publications - Amanda Sue
Division of Viral Hepatitis, Centers for Disease Control and Prevention, 1600 Clifton Road, MS A33, Atlanta, GA, 30329, USA
3 shared publications Pavel Skums
Department of Computer Science, Georgia State University Atlanta, GA 30302
3 shared publications
Latest Publications
- 28 March 2026
- Published by SAGE Publications in Journal of Computational Biology
- Vol. 33 (5-6) , 705-715
Assessment of PHRED Score Characteristics in Illumina MiSeq Amplicon Sequencing
PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as a monotonic function of the probability that the basecall is incorrect. The calibration of PHRED scores has previously been examined by evaluating errors made in reading known sequences. We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large dataset. We also derive calibration methods for the PHRED scores in datasets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST). The GHOST protocol uses a short amplicon, resulting in many positions having two base calls, one coming from each of the paired reads. A maximum likelihood model of redundant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations ( p < 0.0001 ) from being calibrated. The accuracy of the scores varied significantly between the MiSeq instrument runs. Recalibration produced quality scores that improved Brier scores for the dataset by an average relative improvement of 2.83 % . Methods developed to create calibration curves for PHRED scores will be useful in improving error-correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.
- 28 March 2026
- Published by SAGE Publications in Journal of Computational Biology
- Vol. 33 (5-6) , 705-715
Assessment of PHRED Score Characteristics in Illumina MiSeq Amplicon Sequencing
PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as a monotonic function of the probability that the basecall is incorrect. The calibration of PHRED scores has previously been examined by evaluating errors made in reading known sequences. We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large dataset. We also derive calibration methods for the PHRED scores in datasets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST). The GHOST protocol uses a short amplicon, resulting in many positions having two base calls, one coming from each of the paired reads. A maximum likelihood model of redundant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations ( p < 0.0001 ) from being calibrated. The accuracy of the scores varied significantly between the MiSeq instrument runs. Recalibration produced quality scores that improved Brier scores for the dataset by an average relative improvement of 2.83 % . Methods developed to create calibration curves for PHRED scores will be useful in improving error-correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.
- Open Access
- 17 April 2025
- Published by Springer Nature in Research Square
Assessment of PHRED Score Characteristics inIllumina MiSeq Amplicon Sequencing
Background: PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as the probability that the basecall is incorrect. The calibration of PHRED scores has been examined in other studies by evaluating errors made in reading known sequences. Methods: We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large data set. We also derive calibration meth- ods to adjust the PHRED scores to reflect characteristics of data sets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST) error correction pipeline. The GHOST protocol intentionally uses a short amplicon, resulting in a region where many positions have two base calls, one coming from each of the paired reads. A maximum likelihood model of redun- dant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. Results: The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations (p < 0.0001) from being calibrated. The accuracy of the scores varied significantly among MiSeq instrument runs. Recalibration procedures produced quality scores that improved Brier scores for paired base matching by an average relative improvement of 2.83%. Conclusions: Methods developed to create calibration curves for PHRED scores will be useful in improving error correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The MiSeq instrument fails to separate substitution base calls from adjacent correct base calls. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.
- 17 April 2025
- Published by Springer Nature in Research Square
Open AccessAssessment of PHRED Score Characteristics inIllumina MiSeq Amplicon Sequencing
Background: PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as the probability that the basecall is incorrect. The calibration of PHRED scores has been examined in other studies by evaluating errors made in reading known sequences. Methods: We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large data set. We also derive calibration meth- ods to adjust the PHRED scores to reflect characteristics of data sets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST) error correction pipeline. The GHOST protocol intentionally uses a short amplicon, resulting in a region where many positions have two base calls, one coming from each of the paired reads. A maximum likelihood model of redun- dant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. Results: The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations (p < 0.0001) from being calibrated. The accuracy of the scores varied significantly among MiSeq instrument runs. Recalibration procedures produced quality scores that improved Brier scores for paired base matching by an average relative improvement of 2.83%. Conclusions: Methods developed to create calibration curves for PHRED scores will be useful in improving error correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The MiSeq instrument fails to separate substitution base calls from adjacent correct base calls. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.
- 19 October 2022
- Published by Springer Nature
- p. 163-175
An SVM Based Approach to Study the Racial Disparity in Triple-Negative Breast Cancer
- 19 October 2022
- Published by Springer Nature
- p. 163-175
An SVM Based Approach to Study the Racial Disparity in Triple-Negative Breast Cancer
- 1 November 2018
- Published by Elsevier in Infection, Genetics and Evolution
- Vol. 65, 216-225
HCV adaptation to HIV coinfection
- 1 November 2018
- Published by Elsevier in Infection, Genetics and Evolution
- Vol. 65, 216-225
HCV adaptation to HIV coinfection
- Open Access
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 358-358:15
Automated quality control for a molecular surveillance system
Molecular surveillance and outbreak investigation are important for elimination of hepatitis C virus (HCV) infection in the United States. A web-based system, Global Hepatitis Outbreak and Surveillance Technology (GHOST), has been developed using Illumina MiSeq-based amplicon sequence data derived from the HCV E1/E2-junction genomic region to enable public health institutions to conduct cost-effective and accurate molecular surveillance, outbreak detection and strain characterization. However, as there are many factors that could impact input data quality to which the GHOST system is not completely immune, accuracy of epidemiological inferences generated by GHOST may be affected. Here, we analyze the data submitted to the GHOST system during its pilot phase to assess the nature of the data and to identify common quality concerns that can be detected and corrected automatically. The GHOST quality control filters were individually examined, and quality failure rates were measured for all samples, including negative controls. New filters were developed and introduced to detect primer dimers, loss of specimen-specific product, or short products. The genotyping tool was adjusted to improve the accuracy of subtype calls. The identification of “chordless” cycles in a transmission network from data generated with known laboratory-based quality concerns allowed for further improvement of transmission detection by GHOST in surveillance settings. Parameters derived to detect actionable common quality control anomalies were incorporated into the automatic quality control module that rejects data depending on the magnitude of a quality problem, and warns and guides users in performing correctional actions. The guiding responses generated by the system are tailored to the GHOST laboratory protocol. Several new quality control problems were identified in MiSeq data submitted to GHOST and used to improve protection of the system from erroneous data and users from erroneous inferences. The GHOST system was upgraded to include identification of causes of erroneous data and recommendation of corrective actions to laboratory users.
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 358-358:15
Open AccessAutomated quality control for a molecular surveillance system
Molecular surveillance and outbreak investigation are important for elimination of hepatitis C virus (HCV) infection in the United States. A web-based system, Global Hepatitis Outbreak and Surveillance Technology (GHOST), has been developed using Illumina MiSeq-based amplicon sequence data derived from the HCV E1/E2-junction genomic region to enable public health institutions to conduct cost-effective and accurate molecular surveillance, outbreak detection and strain characterization. However, as there are many factors that could impact input data quality to which the GHOST system is not completely immune, accuracy of epidemiological inferences generated by GHOST may be affected. Here, we analyze the data submitted to the GHOST system during its pilot phase to assess the nature of the data and to identify common quality concerns that can be detected and corrected automatically. The GHOST quality control filters were individually examined, and quality failure rates were measured for all samples, including negative controls. New filters were developed and introduced to detect primer dimers, loss of specimen-specific product, or short products. The genotyping tool was adjusted to improve the accuracy of subtype calls. The identification of “chordless” cycles in a transmission network from data generated with known laboratory-based quality concerns allowed for further improvement of transmission detection by GHOST in surveillance settings. Parameters derived to detect actionable common quality control anomalies were incorporated into the automatic quality control module that rejects data depending on the magnitude of a quality problem, and warns and guides users in performing correctional actions. The guiding responses generated by the system are tailored to the GHOST laboratory protocol. Several new quality control problems were identified in MiSeq data submitted to GHOST and used to improve protection of the system from erroneous data and users from erroneous inferences. The GHOST system was upgraded to include identification of causes of erroneous data and recommendation of corrective actions to laboratory users.
- Open Access
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 360-360:10
Fast estimation of genetic relatedness between members of heterogeneous populations of closely related genomic variants
Many biological analysis tasks require extraction of families of genetically similar sequences from large datasets produced by Next-generation Sequencing (NGS). Such tasks include detection of viral transmissions by analysis of all genetically close pairs of sequences from viral datasets sampled from infected individuals or studying of evolution of viruses or immune repertoires by analysis of network of intra-host viral variants or antibody clonotypes formed by genetically close sequences. The most obvious naïeve algorithms to extract such sequence families are impractical in light of the massive size of modern NGS datasets. In this paper, we present fast and scalable k-mer-based framework to perform such sequence similarity queries efficiently, which specifically targets data produced by deep sequencing of heterogeneous populations such as viruses. It shows better filtering quality and time performance when comparing to other tools. The tool is freely available for download at https://github.com/vyacheslav-tsivina/signature-sj The proposed tool allows for efficient detection of genetic relatedness between genomic samples produced by deep sequencing of heterogeneous populations. It should be especially useful for analysis of relatedness of genomes of viruses with unevenly distributed variable genomic regions, such as HIV and HCV. For the future we envision, that besides applications in molecular epidemiology the tool can also be adapted to immunosequencing and metagenomics data.
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 360-360:10
Open AccessFast estimation of genetic relatedness between members of heterogeneous populations of closely related genomic variants
Many biological analysis tasks require extraction of families of genetically similar sequences from large datasets produced by Next-generation Sequencing (NGS). Such tasks include detection of viral transmissions by analysis of all genetically close pairs of sequences from viral datasets sampled from infected individuals or studying of evolution of viruses or immune repertoires by analysis of network of intra-host viral variants or antibody clonotypes formed by genetically close sequences. The most obvious naïeve algorithms to extract such sequence families are impractical in light of the massive size of modern NGS datasets. In this paper, we present fast and scalable k-mer-based framework to perform such sequence similarity queries efficiently, which specifically targets data produced by deep sequencing of heterogeneous populations such as viruses. It shows better filtering quality and time performance when comparing to other tools. The tool is freely available for download at https://github.com/vyacheslav-tsivina/signature-sj The proposed tool allows for efficient detection of genetic relatedness between genomic samples produced by deep sequencing of heterogeneous populations. It should be especially useful for analysis of relatedness of genomes of viruses with unevenly distributed variable genomic regions, such as HIV and HCV. For the future we envision, that besides applications in molecular epidemiology the tool can also be adapted to immunosequencing and metagenomics data.
- Open Access
Fast estimation of genetic relatedness between members of heterogeneous populations of closely related genomic variants
Many biological analysis tasks require extraction of families of genetically similar sequences from large datasets produced by Next-generation Sequencing (NGS). Such tasks include detection of viral transmissions by analysis of all genetically close pairs of sequences from viral datasets sampled from infected individuals or studying of evolution of viruses or immune repertoires by analysis of network of intra-host viral variants or antibody clonotypes formed by genetically close sequences. The most obvious naϊeve algorithms to extract such sequence families are impractical in light of the massive size of modern NGS datasets. In this paper, we present fast and scalable k-mer-based framework to perform such sequence similarity queries efficiently, which specifically targets data produced by deep sequencing of heterogeneous populations such as viruses. The tool is freely available for download at https://github.com/vyacheslav-tsivina/signature-sj
Open AccessFast estimation of genetic relatedness between members of heterogeneous populations of closely related genomic variants
Many biological analysis tasks require extraction of families of genetically similar sequences from large datasets produced by Next-generation Sequencing (NGS). Such tasks include detection of viral transmissions by analysis of all genetically close pairs of sequences from viral datasets sampled from infected individuals or studying of evolution of viruses or immune repertoires by analysis of network of intra-host viral variants or antibody clonotypes formed by genetically close sequences. The most obvious naϊeve algorithms to extract such sequence families are impractical in light of the massive size of modern NGS datasets. In this paper, we present fast and scalable k-mer-based framework to perform such sequence similarity queries efficiently, which specifically targets data produced by deep sequencing of heterogeneous populations such as viruses. The tool is freely available for download at https://github.com/vyacheslav-tsivina/signature-sj
- Open Access
- 6 December 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (S10) , 916
GHOST: global hepatitis outbreak and surveillance technology
Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics expertise. Improvement in molecular detection capacity will contribute to increasing the rate of transmission detection, thus providing opportunity for rapid, accurate and effective response to outbreaks of hepatitis C. Although GHOST was originally developed for hepatitis C surveillance, its modular structure is readily applicable to other infectious diseases. Worldwide availability of GHOST for the detection of HCV transmissions will foster deeper involvement of public health researchers and practitioners in hepatitis C outbreak investigation.
- 6 December 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (S10) , 916
Open AccessGHOST: global hepatitis outbreak and surveillance technology
Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics expertise. Improvement in molecular detection capacity will contribute to increasing the rate of transmission detection, thus providing opportunity for rapid, accurate and effective response to outbreaks of hepatitis C. Although GHOST was originally developed for hepatitis C surveillance, its modular structure is readily applicable to other infectious diseases. Worldwide availability of GHOST for the detection of HCV transmissions will foster deeper involvement of public health researchers and practitioners in hepatitis C outbreak investigation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Efficient filtering algorithm for detection of genetic similarity between large genomic datasets
Many biological analysis techniques require measurement of similarity between sequences from large genomic datasets, which often involves extraction of all pairs of close DNA or RNA sequences. We present a k-mer-based tool to efficiently perform such sequence similarity queries for large viral datasets produced by next-generation sequencing.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Efficient filtering algorithm for detection of genetic similarity between large genomic datasets
Many biological analysis techniques require measurement of similarity between sequences from large genomic datasets, which often involves extraction of all pairs of close DNA or RNA sequences. We present a k-mer-based tool to efficiently perform such sequence similarity queries for large viral datasets produced by next-generation sequencing.
- Open Access
- 24 May 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (4) , 372
Efficient detection of viral transmissions with Next-Generation Sequencing data.
- 24 May 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (4) , 372
Open AccessEfficient detection of viral transmissions with Next-Generation Sequencing data.