Leming Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Leming Cheng has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Chenghang Zheng
Zhejiang University
4 shared publications Qinhui Wang
State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering, Zhejiang University, Hangzhou 310027, P. R. China
4 shared publicationsZhangke Ma
Zhejiang Univ, Inst Thermal Power Engn, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
4 shared publicationsZhongyang Luo
4 shared publicationsJieqiang Ji
State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering, Zhejiang University, Hangzhou 310027, P. R. China
3 shared publicationsKefa Cen
State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, Zhejiang, China
3 shared publications
Latest Publications
- 10 August 2024
- Published by Elsevier in Particuology
- Vol. 94, 187-196
Experimental study on gas uniformity at the inlets of six cyclones in a CFB with multi-tracer gas method
- 10 August 2024
- Published by Elsevier in Particuology
- Vol. 94, 187-196
Experimental study on gas uniformity at the inlets of six cyclones in a CFB with multi-tracer gas method
- 8 September 2023
- Published by Springer Nature in Journal of Thermal Science
- Vol. 32 (5) , 1832-1848
Comparison of Fully 3-D, Simplified 3-D and 2-D Numerical Simulations on a Circulating Fluidized Bed Boiler
- 8 September 2023
- Published by Springer Nature in Journal of Thermal Science
- Vol. 32 (5) , 1832-1848
Comparison of Fully 3-D, Simplified 3-D and 2-D Numerical Simulations on a Circulating Fluidized Bed Boiler
- 25 May 2023
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 37 (12) , 8364-8373
Desulfurization Characteristics of Carbide Slag during Circulating Fluidized Bed Coal Combustion
- 25 May 2023
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 37 (12) , 8364-8373
Desulfurization Characteristics of Carbide Slag during Circulating Fluidized Bed Coal Combustion
- 2 November 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (45) , 16857-16868
MP-PIC Simulation on Solid Dispersion in a 350 MW CFB Boiler
- 2 November 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (45) , 16857-16868
MP-PIC Simulation on Solid Dispersion in a 350 MW CFB Boiler
- Open Access
Effect of Connection Resistance between Cyclones and Backpass on Furnace Solids Suspension Density Profile and Circulation Rates in CFB
The connection section between cyclones and backpass is an important configuration in multi-cyclone circulating fluidized bed boilers (CFB). In this work, the resistance coefficient of different connection modes, and connection resistance distribution from each cyclone outlet to backpass (connection branch) in one mode are defined and calculated, in order to investigate their effects on furnace solids suspension density distribution and circulation rates. Three connection modes with different overall resistance coefficients were tested experimentally and analyzed by a 1.5-dimensional model in a four-cyclone scaling CFB apparatus. Both experimental and theoretical results show that, with larger overall resistance of a connection, there are more solids suspended in the furnace bottom and fewer in the top section. The investigation of the C-type connection has revealed that when the branch resistance of the connection decreases from branch No. 1–4, the solids suspension density and circulation rate from corresponding solids recycle loops (No. 1–4) increase. Moreover, the non-uniformity of connection branch resistance distribution will lead to uneven lateral solids suspension density distribution and circulation rates allocation. This effect is enhanced by growing superficial velocity.
Open AccessEffect of Connection Resistance between Cyclones and Backpass on Furnace Solids Suspension Density Profile and Circulation Rates in CFB
The connection section between cyclones and backpass is an important configuration in multi-cyclone circulating fluidized bed boilers (CFB). In this work, the resistance coefficient of different connection modes, and connection resistance distribution from each cyclone outlet to backpass (connection branch) in one mode are defined and calculated, in order to investigate their effects on furnace solids suspension density distribution and circulation rates. Three connection modes with different overall resistance coefficients were tested experimentally and analyzed by a 1.5-dimensional model in a four-cyclone scaling CFB apparatus. Both experimental and theoretical results show that, with larger overall resistance of a connection, there are more solids suspended in the furnace bottom and fewer in the top section. The investigation of the C-type connection has revealed that when the branch resistance of the connection decreases from branch No. 1–4, the solids suspension density and circulation rate from corresponding solids recycle loops (No. 1–4) increase. Moreover, the non-uniformity of connection branch resistance distribution will lead to uneven lateral solids suspension density distribution and circulation rates allocation. This effect is enhanced by growing superficial velocity.
- 3 September 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (18) , 14805-14815
Evaluation of Different Red Muds as Oxygen Carriers in a Fluidized Bed Thermogravimetric Analyzer
- 3 September 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (18) , 14805-14815
Evaluation of Different Red Muds as Oxygen Carriers in a Fluidized Bed Thermogravimetric Analyzer
- 27 November 2019
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 104 (2) , 765-774
Efficient biotransformation of vitamin D3 to 25-hydroxyvitamin D3 by a newly isolated Bacillus cereus strain
25-hydroxyvitamin D3 has attracted considerable attention due to its great medical value and huge market demand in animal husbandry. Microbial production of 25-hydroxyvitamin D3 has been recognized as an alternative superior to traditional chemical synthesis. In this study, a Gram-positive bacteria zju 4-2 (CCTCC M 2019385) was isolated from the soil using vitamin D3 as the sole carbon source and was identified as Bacillus cereus according to its physiological characteristics and 16S rRNA analysis, which also showed a relatively high capacity for 25-hydroxyvitamin D3 production. Through systematic optimization of different catalytic conditions, the optimal solvent system of vitamin D3, vitamin D3 addition time and concentration, temperature, and pH were shown to be propylene glycol/ethanol (v/v = 9:1), early stationary phase, 2 g/L, 37 °C, and pH 7.2, respectively. With these optimal conditions, 796 mg/L of 25-hydroxyvitamin D3 was achieved after 48 h bioconversion with zju 4-2 at the shake flask level. Finally, up to 830 mg/L 25-hydroxyvitamin D3 with a yield of 41.5% was obtained in a 5 L fermentation tank. Our developed biotransformation process with this newly isolated strain provides a platform to produce 25-hydroxyvitamin D3 efficiently at industrialization scale.
- 27 November 2019
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 104 (2) , 765-774
Efficient biotransformation of vitamin D3 to 25-hydroxyvitamin D3 by a newly isolated Bacillus cereus strain
25-hydroxyvitamin D3 has attracted considerable attention due to its great medical value and huge market demand in animal husbandry. Microbial production of 25-hydroxyvitamin D3 has been recognized as an alternative superior to traditional chemical synthesis. In this study, a Gram-positive bacteria zju 4-2 (CCTCC M 2019385) was isolated from the soil using vitamin D3 as the sole carbon source and was identified as Bacillus cereus according to its physiological characteristics and 16S rRNA analysis, which also showed a relatively high capacity for 25-hydroxyvitamin D3 production. Through systematic optimization of different catalytic conditions, the optimal solvent system of vitamin D3, vitamin D3 addition time and concentration, temperature, and pH were shown to be propylene glycol/ethanol (v/v = 9:1), early stationary phase, 2 g/L, 37 °C, and pH 7.2, respectively. With these optimal conditions, 796 mg/L of 25-hydroxyvitamin D3 was achieved after 48 h bioconversion with zju 4-2 at the shake flask level. Finally, up to 830 mg/L 25-hydroxyvitamin D3 with a yield of 41.5% was obtained in a 5 L fermentation tank. Our developed biotransformation process with this newly isolated strain provides a platform to produce 25-hydroxyvitamin D3 efficiently at industrialization scale.
- 18 April 2019
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 33 (5) , 4169-4176
Direct Measurement of Gaseous Sodium in Flue Gas for High-Alkali Coal
- 18 April 2019
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 33 (5) , 4169-4176
Direct Measurement of Gaseous Sodium in Flue Gas for High-Alkali Coal
- 9 January 2019
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 33 (2) , 916-926
Investigation on Sodium Fate for High Alkali Coal during Circulating Fluidized Bed Combustion
- 9 January 2019
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 33 (2) , 916-926
Investigation on Sodium Fate for High Alkali Coal during Circulating Fluidized Bed Combustion
- Open Access
- 2 October 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (59) , 33817-33827
Ash deposition behavior of a high-alkali coal in circulating fluidized bed combustion at different bed temperatures and the effect of kaolin
High alkali and alkali earth metals (AAEMs) content in coal causes severe slagging and fouling during combustion in a boiler. In this study, the ash deposition behavior of a high-alkali coal at different bed temperatures and the effect of kaolin were investigated in a 30 kW circulating fluidized bed (CFB) test system using an ash slagging probe and deposition probe. The results show that the ash deposition tendency increases with the bed temperature. The condensation of Na2SO4 is an important inducement for slag formation in the furnace. The melting or partial melting of slags is attributed to Na–Fe–Ca eutectics. At 920 °C, Na2SO4 will react with CaSO4 to form the low-melting compound of Na2SO4–CaSO4. The deposited ash on the convection-heating surface consists of granular particles. On the windward side, the layered-structure ash deposits, i.e. the inner and outer layers, are formed at the bed temperature of 920 °C but are absent at lower temperatures (820 °C and 870 °C). The formation of the inner layer consists of fine particles (2SO4. The size of the deposited ash in the outer layer is larger than 10 μm, while that on the leeward side is less than 10 μm. By adding kaolin in the coal, the slags are replaced by loose particles due to the absorption reactions between kaolin and alkali metals. The ash deposition tendency is improved and the optimal result is achieved when kaolin is added at an addition ratio of 3%.
- 2 October 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (59) , 33817-33827
Open AccessAsh deposition behavior of a high-alkali coal in circulating fluidized bed combustion at different bed temperatures and the effect of kaolin
High alkali and alkali earth metals (AAEMs) content in coal causes severe slagging and fouling during combustion in a boiler. In this study, the ash deposition behavior of a high-alkali coal at different bed temperatures and the effect of kaolin were investigated in a 30 kW circulating fluidized bed (CFB) test system using an ash slagging probe and deposition probe. The results show that the ash deposition tendency increases with the bed temperature. The condensation of Na2SO4 is an important inducement for slag formation in the furnace. The melting or partial melting of slags is attributed to Na–Fe–Ca eutectics. At 920 °C, Na2SO4 will react with CaSO4 to form the low-melting compound of Na2SO4–CaSO4. The deposited ash on the convection-heating surface consists of granular particles. On the windward side, the layered-structure ash deposits, i.e. the inner and outer layers, are formed at the bed temperature of 920 °C but are absent at lower temperatures (820 °C and 870 °C). The formation of the inner layer consists of fine particles (2SO4. The size of the deposited ash in the outer layer is larger than 10 μm, while that on the leeward side is less than 10 μm. By adding kaolin in the coal, the slags are replaced by loose particles due to the absorption reactions between kaolin and alkali metals. The ash deposition tendency is improved and the optimal result is achieved when kaolin is added at an addition ratio of 3%.