TMTugce Ozekli Misirlioglu

Tugce Ozekli Misirlioglu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tugce Ozekli Misirlioglu has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Ultrasound-Guided Lavage and Subacromial Bursa Injection for Calcific Tendinitis: A Prospective, Randomized, Double-Blind Trial

    by Nuri Tuğbay Yıldıran, Bilge Çakır, Tuğçe Özekli Mısırlıoğlu, Rana Terlemez, Kenan Akgün, Deniz Palamar

  • Open Access

    Turkish version of the American Academy of Orofacial Pain screening questionnaire for temporomandibular disorders: Its cross-cultural adaptation, validity, and reliability

    by Tuğçe Özekli Mısırlıoğlu, Özden Özyemişci Taşkıran, Deniz Palamar, Caner Günerbüyük, Pelin Yıldız, Arzu Baygül, Kenan Akgün

    Objectives: This study aims to translate and cross-culturally adapt the American Academy of Orofacial Pain (AAOP) screening questionnaire and assess its validity and reliability. Patients and methods: This cross-sectional study included a total of 60 patients (16 males, 44 females; mean age: 50.9±17.3 years; range, 19 to 84 years) admitted to a Physical Medicine And Rehabilitation Outpatient Clinic between January 2016 and June 2016. Backward and forward translation of AAOP questionnaire was performed in both languages. Diagnostic Criteria for Temporomandibular Disorders was used to as a reference standard. Validity was assessed with internal construct and criterion validity. Reliability was evaluated with test-retest reliability and internal consistency. Results: Fifty-seven percent of the patients were classified as having a temporomandibular disorder. The factor analysis yielded three components that explained 63.8% of the variance. The internal consistency of the AAOP questionnaire was acceptable (Cronbach’s alpha value=0.781). The correlation coefficient for the intra- and interrater reliability were found as 0.740 and 0.713, respectively. Conclusion: The Turkish version of the AAOP screening questionnaire is a valid and reliable tool for screening of patients admitted to physical medicine and rehabilitation outpatient clinics with a good internal consistency, intra- and interrater reliability.

  • Open Access

    Development of artificial intelligence and multi-sensor-based dexterity assessment system: performance evaluation

    by Mehmet Emin Aktan, Sena Zeybek Kılıç, Erhan Akdoğan, Tuğçe Özekli Mısırlıoğlu, Deniz Palamar

    Manual dexterity tests are essential for diagnosing diseases and evaluating professional skills that require fine motor control. Traditional assessments often depend on expert supervision, leading to delays, subjectivity, and inaccuracies. This study introduces an automated dexterity assessment system that integrates multiple sensors and artificial intelligence algorithms for high-precision evaluation. The system classifies hand movements, analyzes muscle contraction levels, and determines hold-release durations using electromyography (EMG), inertial measurement units (IMU), and image processing techniques. An expert system interprets the multimodal sensor data and presents the results to clinicians. A performance evaluation with 20 participants demonstrated the system’s capability to assess hand dexterity automatically and accurately. Graphical Abstract

  • Open Access

    Sensitivity and specificity assessment of four clinical tests for palmaris longus muscle by ultrasound

    by Zennure Adıgüzel Şahin, Mehmet Üzel, Fatma Güler Kahraman Yıldırım, Mahmut Ercan Tanyeli, Ahmet Ertaş, Deniz Palamar, Tuğçe Özekli Mısırlıoğlu, Kenan Akgün, Ahmet Dirican

    Objectives: This study aimed to evaluate the accuracy of four clinical tests confirmed by ultrasonography (USG) and to evaluate the role of age, sex, handedness, subcutaneous tissue thickness (STT), tendon thickness (TT), and STT/TT in determining the absence of the palmaris longus muscle. Patients and methods: In this descriptive study, 282 wrists of 141 healthy individuals (71 females, 70 males; mean age: 29±9.6 years; range, 21 to 55 years) were included between September 2021 and November 2022. The palmaris longus muscle tendon was identified by Schaeffer’s test, Mishra’s test I, Thompson’s test, and Pushpakumar’s test and then evaluated with USG. Before the tests, age, sex, and dominant hand information of the individuals were obtained. The STT and TT were measured with USG. Results: Sensitivity values by side were as follows (right/left respectively): Schaeffer’s 92%/73%, Mishra’s I 91%/93%, Thompson’s 84%/87%, and Pushpakumar’s 86%/91%. Specificity values by side were as follows (right/left respectively): Schaeffer’s 87%/95%, Mishra’s I 78%/82%, Thompson’s 78%/79%, and Pushpakumar’s 84%/82%. Sensitivity values by sex were as follows (female/male respectively): Schaeffer’s 81%/96%, Mishra’s I 92%/94%, Thompson’s 85%/90%, and Pushpakumar’s 91%/92%. Specificity values by sex were as follows (female/male respectively): Schaeffer’s 68%/90%, Mishra’s I 72%/90%, Thompson’s 72%/85%, and Pushpakumar’s 78%/85%. The intraclass correlation coefficient between clinical tests and USG was 0.94 for the left side and 0.95 for the right side. Conclusion: Mishra’s test I and Pushpakumar’s test can be used in females, while Schaeffer's test and Mishra’s test I can be used in males as a mutually supportive clinical test. Furthermore, while there may be false negative and false positive test results due to muscle variations, it should be noted that STT/TT is also effective, particularly on the right side.


  • DESIGN, DEVELOPMENT AND HYBRID IMPEDANCE CONTROL OF AN ANKLE REHABILITATION ROBOT

    by Emre Yildirim, Mehmet Emi̇n Aktan, Erhan Akdoğan, Tuğçe Özekli̇ Misirlioğlu, Deni̇z Palamar

    In this study, a hybrid impedance control-based portable ankle rehabilitation robot that can perform therapeutic exercises for the ankle has been developed. This 1-DOF robot can perform plantar flexion and dorsiflexion movements for the ankle. The capacity of the robotic system to perform therapeutic exercises was tested with subjects. Isotonic and resistive exercises were tested with 10 healthy subjects and stretching exercise was tested with a patient. The results showed that the hybrid impedance controlled robotic system can successfully perform passive stretching, active isotonic and active resistive exercises by providing a safe human-robot interaction. Especially when a sudden resistance increase occurs in the joint, the hybrid impedance controller acts like a physiotherapist and performs the movement without damaging the joint.


  • The frequency of superior cluneal nerve entrapment diagnosed with ultrasound‐guided nerve block in patients with low back pain: A prospective, cross‐sectional study

    by Busra Sezer Kiral, Tugce Ozekli Misirlioglu, Rana Terlemez, Deniz Palamar, Dogan Kiral, Eren Aygun, Kenan Akgun

    Introduction: To determine the frequency of superior cluneal nerve entrapment (SCN‐E) in patients who applied to our outpatient clinic with low back pain.Methods: Two hundred patients with mechanical low back pain persisting more than 3 months were included in our study. All patients were evaluated with detailed clinical history and physical examination. Ultrasound‐guided diagnostic injection was performed in patients who had tenderness on the posterior iliac crest and whose main complaint emerged by pressing on this point. Patients with 70% or greater pain relief 1 h after the injection were considered as SCN‐E. The frequency and clinical features of SCN‐E were determined and compared with other mechanical low back pain.Results: The mean age of the patients included in our study was 48.56 ± 14.11 years, with 138 female and 62 male patients. The diagnostic injection was performed on 31 patients and considered positive in 24 of them. The frequency of SCN‐E was determined as 12%. The Hip‐Knee Flexion Test was determined to be more specific for SCN‐E than other causes of low back pain, the sensitivity and specificity of the test were 41.67% and 88.64% (p = 0.001; p < 0.01). In addition, all demographic and clinical features in patients diagnosed with SCN‐E were found to be similar to other mechanical low back pain cases.Conclusions: In patients with chronic low back pain, SCN‐E is not a rare cause and is often overlooked. Increasing the awareness and experience of physicians on SCN‐E will prevent patients from being exposed to unnecessary surgical or non‐surgical treatments.


  • Ultrasonographic evaluation of ulnar nerve morphology in patients with ulnar nerve instability

    by Narmin Ahmadli, Kenan Akgun, Rana Terlemez, Tugce Ozekli Misirlioglu, Deniz Palamar

    Introduction/Aims: Ulnar nerve instability (UNI) in the retroepicondylar groove is described as nerve subluxation or dislocation. In this study, considering that instability may cause chronic ulnar nerve damage by increasing the friction risk, we aimed to examine the effects of UNI on nerve morphology ultrasonographically.Methods: Asymptomatic patients with clinical suspicion of UNI were referred for further clinical and ultrasonographic examination. Based on ulnar nerve mobility on ultrasound, the patients were first divided into two groups: stable and unstable. The unstable group was further divided into two subgroups: subluxation and dislocation. The cross‐sectional area (CSA) of the nerve was measured in three regions relative to the medial epicondyle (ME).Results: In the ultrasonographic evaluation, UNI was identified in 59.1% (52) of the 88 elbows. UNI was bilateral in 50% (22) of the 44 patients. Mean CSA was not significantly different between groups. A statistically significant difference in ulnar nerve mobility was found between the group with CSA of 2 (p = .027). Nerve instability was found in 85.7% of elbows with an ulnar nerve CSA value of ≥10 mm2 at the ME level.Discussion: The probability of developing neuropathy in patients with UNI may be higher than in those with normal nerve mobility. Further prospective studies are required to elucidate whether asymptomatic individuals with UNI and increased CSA may be at risk for developing symptomatic ulnar neuropathy at the elbow.


  • Open Access

    Ultrasonographic Evaluation of Nail Involvement in Patients With Axial Spondyloarthritis

    by Bilal Kulaksız, Deniz Palamar, Tugce Ozekli Misirlioglu, Kenan Akgun, Rana Terlemez

    Objectives-This study aimed to evaluate the nail units of patients with axial spondyloarthritis (ax-SpA) using ultrasound and to identify any subclinical changes. We also aimed to examine the relationship between clinical enthesitis scores and nail involvement in patients with ax-SpA. Methods-The study included 40 patients with ax-Spa, 40 patients with psoriatic arthritis (PsA), and 40 healthy controls. the thickness of the nail plates, morphological changes, the thickness of the proximal nail units, the thickness of the nail beds, and power Doppler signal intensities were evaluated and compared. Maastricht Ankylosing Spondylitis Enthesitis Score and Spondyloarthritis Research Consortium of Canada Enthesitis Index were also evaluated in patients with ax-SpA. Results-There was no significant difference between the thickness of the nail plates of the three groups (P > .05). The first nail bed thickness of ax-SpA cases was significantly higher than the control group (P = .046), and the fourth and fifth nail proximal unit thicknesses of the control group were significantly lower than the ax-SpA and PsA groups (P = .023, P = .017). We also found that the Wortsman scores of the cases with PsA were significantly higher than the ax-SpA and control groups (P = .0001). Conclusion-The thickness of the proximal nail unit adjacent to the insertion of the digital extensor tendon, which is considered as the enthesis area, is similar to the patients with PsA in patients with ax-SpA, especially in the fourth and fifth fingers compared to the control group. On the other hand, almost no structural changes in nail plates were observed in patients with ax-SpA group.


  • Open Access

    An unusual cause of posterior interosseous nerve palsy and contribution of ultrasonography to electromyography in a patient with neurofibroma

    by Deniz Palamar, Kenan Akgün, Tuğçe Özekli Mısırlıoğlu, Rana Terlemez, Atakan Aydın, Meral Erdemir Kızıltan

    Neurofibroma, a benign peripheral nerve sheath tumor, represents a rare cause of posterior interosseous nerve syndrome. Electrodiagnostic studies may not identify the exact site of nerve compression, a possible lesion that compresses the nerve and do not provide information about the morphological changes. Ultrasound is a cost-effective, practical modality that provides the opportunity for dynamic tracking in the peripheral nerves, and it is widely considered as the initial imaging modality for peripheral nerves. Herein, we report a case of posterior interosseous nerve palsy in a 13-year-old boy with neurofibroma of posterior interosseous nerve diagnosed with ultrasound. The benefit of ultrasound in localizing and determining the etiology of the posterior interosseous nerve palsy is emphasized in this case report. A meticulous ultrasound examination is recommended in suspected peripheral nerve lesions, regardless of the results of electrophysiological and imaging modalities.


  • Open Access

    Why is Nerve Ultrasound Scan Necessary for Peripheral Nerve Lesions?

    by Deniz Palamar, Tuğçe Özekli Mısırlıoğlu, Rana Terlemez, Bülent Özçelik, Kenan Akgün