Dariusz Janusek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dariusz Janusek has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
R. Maniewski
Nalecz Institute of Biocybernetics and Biomedical Engineering PAS
6 shared publications- Michal Kania
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Trojdena 4, 02-109, Warsaw, Poland.
5 shared publications - Andrzej Przybylski
Faculty of Medicine, University of Rzeszów, Poland
3 shared publications - Adam Liebert
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications H. Zavala-Fernandez
Department for Biophysical Measurements and Imaging, Nalecz Institute of Biocybernetic and Biomedical Engineering PAS, 4 Ks. Trojdena Str., 02-109 Warsaw, Poland
2 shared publicationsM. Fereniec
Institute of Biocybernetics and Biomedical Engineering PAS, Warsaw, Poland
2 shared publications
Latest Publications
- 29 May 2019
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 29 (05) , 1850033
Causal Coupling Between Electrophysiological Signals, Cerebral Hemodynamics and Systemic Blood Supply Oscillations in Mayer Wave Frequency Range
The aim of the study was to assess causal coupling between neuronal activity, microvascular hemodynamics and blood supply oscillations in the Mayer wave frequency range. An electroencephalogram, cerebral blood oxygenation changes, an electrocardiogram and blood pressure were recorded during rest and during a movement task. Causal coupling between them was evaluated using directed transfer function, a measure based on the Granger causality principle. The multivariate autoregressive model was fitted to all the signals simultaneously, which made it possible to construct a complete scheme of interactions between the considered signals. The obtained pattern of interactions in the resting state estimated in the 0.05–0.15 Hz band revealed a predominant influence of blood pressure oscillations on all the other variables. Reciprocal connections between blood pressure and heart rate variability time series indicated the presence of feedback loops between these signals. During movement, the pattern of connections did not change dramatically. The number of connections decreased, but the couplings between blood pressure and heart rate variability signal were not significantly changed, and the strong influence of the decreased blood hemoglobin concentration on the oxygenated hemoglobin concentration persisted. For the first time our results provided a comprehensive scheme of interactions between electrical and hemodynamic brain signals, heart rate and blood pressure oscillations. Persistent reciprocal connections between blood pressure and heart rate variability time series suggest possible feedforward and feedback coupling of cardiovascular variables which may lead to the observed oscillations in Mayer wave range.
- 29 May 2019
- Published by World Scientific Pub Co Pte Ltd in International Journal of Neural Systems
- Vol. 29 (05) , 1850033
Causal Coupling Between Electrophysiological Signals, Cerebral Hemodynamics and Systemic Blood Supply Oscillations in Mayer Wave Frequency Range
The aim of the study was to assess causal coupling between neuronal activity, microvascular hemodynamics and blood supply oscillations in the Mayer wave frequency range. An electroencephalogram, cerebral blood oxygenation changes, an electrocardiogram and blood pressure were recorded during rest and during a movement task. Causal coupling between them was evaluated using directed transfer function, a measure based on the Granger causality principle. The multivariate autoregressive model was fitted to all the signals simultaneously, which made it possible to construct a complete scheme of interactions between the considered signals. The obtained pattern of interactions in the resting state estimated in the 0.05–0.15 Hz band revealed a predominant influence of blood pressure oscillations on all the other variables. Reciprocal connections between blood pressure and heart rate variability time series indicated the presence of feedback loops between these signals. During movement, the pattern of connections did not change dramatically. The number of connections decreased, but the couplings between blood pressure and heart rate variability signal were not significantly changed, and the strong influence of the decreased blood hemoglobin concentration on the oxygenated hemoglobin concentration persisted. For the first time our results provided a comprehensive scheme of interactions between electrical and hemodynamic brain signals, heart rate and blood pressure oscillations. Persistent reciprocal connections between blood pressure and heart rate variability time series suggest possible feedforward and feedback coupling of cardiovascular variables which may lead to the observed oscillations in Mayer wave range.
- Open Access
- 8 May 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 57
The roles of mid-myocardial and epicardial cells in T-wave alternans development: a simulation study
The occurrence of T-wave alternans in electrocardiographic signals was recently linked to susceptibility to ventricular arrhythmias and sudden cardiac death. Thus, by detecting and comprehending the origins of T-wave alternans, it might be possible to prevent such events. Here, we simulated T-wave alternans in a computer-generated human heart model by modulating the action potential duration and amplitude during the first part of the repolarization phase. We hypothesized that changes in the intracardiac alternans patterns of action potential properties would differentially influence T-wave alternans measurements at the body surface. Specifically, changes were simulated globally in the whole left and right ventricles to simulate concordant T-wave alternans, and locally in selected regions to simulate discordant and regional discordant, hereinafter referred to as “regional”, T-wave alternans. Body surface potential maps and 12-lead electrocardiographic signals were then computed. In depth discrimination, the influence of epicardial layers on T-wave alternans development was significantly higher than that of mid-myocardial cells. Meanwhile, spatial discrimination revealed that discordant and regional action potential property changes had a higher influence on T-wave alternans amplitude than concordant changes. Notably, varying T-wave alternans sources yielded distinct body surface potential map patterns for T-wave alternans amplitude, which can be used for location of regions within hearts exhibiting impaired repolarization. The highest ability for T-wave alternans detection was achieved in lead V1. Ultimately, we proposed new parameters Vector Magnitude Alternans and Vector Angle Alternans, with higher ability for T-wave alternans detection when using multi-lead electrocardiographic signals processing than for single leads. Finally, QT alternans was found to be associated with the process of T-wave alternans generation. The distributions of the body surface T-wave alternans amplitude have been shown to have unique patterns depending on the type of alternans (concordant, discordant or regional) and the location of the disturbance in the heart. The influence of epicardial cells on T-wave alternans development is significantly higher than that of mid-myocardial cells, among which the sub-endocardial layer exerted the highest influence. QT interval alternans is identified as a phenomenon that correlate with T-wave alternans.
- 8 May 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 57
Open AccessThe roles of mid-myocardial and epicardial cells in T-wave alternans development: a simulation study
The occurrence of T-wave alternans in electrocardiographic signals was recently linked to susceptibility to ventricular arrhythmias and sudden cardiac death. Thus, by detecting and comprehending the origins of T-wave alternans, it might be possible to prevent such events. Here, we simulated T-wave alternans in a computer-generated human heart model by modulating the action potential duration and amplitude during the first part of the repolarization phase. We hypothesized that changes in the intracardiac alternans patterns of action potential properties would differentially influence T-wave alternans measurements at the body surface. Specifically, changes were simulated globally in the whole left and right ventricles to simulate concordant T-wave alternans, and locally in selected regions to simulate discordant and regional discordant, hereinafter referred to as “regional”, T-wave alternans. Body surface potential maps and 12-lead electrocardiographic signals were then computed. In depth discrimination, the influence of epicardial layers on T-wave alternans development was significantly higher than that of mid-myocardial cells. Meanwhile, spatial discrimination revealed that discordant and regional action potential property changes had a higher influence on T-wave alternans amplitude than concordant changes. Notably, varying T-wave alternans sources yielded distinct body surface potential map patterns for T-wave alternans amplitude, which can be used for location of regions within hearts exhibiting impaired repolarization. The highest ability for T-wave alternans detection was achieved in lead V1. Ultimately, we proposed new parameters Vector Magnitude Alternans and Vector Angle Alternans, with higher ability for T-wave alternans detection when using multi-lead electrocardiographic signals processing than for single leads. Finally, QT alternans was found to be associated with the process of T-wave alternans generation. The distributions of the body surface T-wave alternans amplitude have been shown to have unique patterns depending on the type of alternans (concordant, discordant or regional) and the location of the disturbance in the heart. The influence of epicardial cells on T-wave alternans development is significantly higher than that of mid-myocardial cells, among which the sub-endocardial layer exerted the highest influence. QT interval alternans is identified as a phenomenon that correlate with T-wave alternans.
- 3 February 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 53 (4) , 361-370
Improved robust T-wave alternans detectors
New statistical and spectral detectors, the modified matched pairs t test, the extended spectral method and the modified spectral method, were proposed for T-wave alternans (TWA) detection gaining robustness according to trend and single-frequency interferences. They were compared to classic detectors such as matched pairs t test, unpaired t test, spectral method, generalized likelihood ratio test and estimated TWA amplitude within a simulation framework and applied to real data. The optimal detection threshold was selected by using a full Monte-Carlo simulation where signals, with and without alternans episodes, were corrupted by Gaussian noise with different power and single-frequency interferences with different tones. All the combinations of noise and frequency were selected and repeated 500 times in order to compute probability of detection ( \(P_{\mathrm{d}}\) ) and the false alarm probability ( \(P_{\mathrm{fa}}\) ), providing ROC curves. The study group consisted of 50 patients with implantable cardioverter-defibrillator (age: \(55.3 \pm 16.4\) ; LVEF: \(42.8 \pm 15.5\) ), who were paced (ventricular pacing) at 100 bpm. Two-minute recordings were analyzed. The XYZ orthogonal lead system was used. The best performance was reached by using the modified matched pairs t test (in comparison with the spectral method and other reference methods).- 3 February 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 53 (4) , 361-370
Improved robust T-wave alternans detectors
New statistical and spectral detectors, the modified matched pairs t test, the extended spectral method and the modified spectral method, were proposed for T-wave alternans (TWA) detection gaining robustness according to trend and single-frequency interferences. They were compared to classic detectors such as matched pairs t test, unpaired t test, spectral method, generalized likelihood ratio test and estimated TWA amplitude within a simulation framework and applied to real data. The optimal detection threshold was selected by using a full Monte-Carlo simulation where signals, with and without alternans episodes, were corrupted by Gaussian noise with different power and single-frequency interferences with different tones. All the combinations of noise and frequency were selected and repeated 500 times in order to compute probability of detection ( \(P_{\mathrm{d}}\) ) and the false alarm probability ( \(P_{\mathrm{fa}}\) ), providing ROC curves. The study group consisted of 50 patients with implantable cardioverter-defibrillator (age: \(55.3 \pm 16.4\) ; LVEF: \(42.8 \pm 15.5\) ), who were paced (ventricular pacing) at 100 bpm. Two-minute recordings were analyzed. The XYZ orthogonal lead system was used. The best performance was reached by using the modified matched pairs t test (in comparison with the spectral method and other reference methods).- 1 April 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 114 (1) , 102-108
A simulation of T-wave alternans vectocardiographic representation performed by changing the ventricular heart cells action potential duration
- 1 April 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 114 (1) , 102-108
A simulation of T-wave alternans vectocardiographic representation performed by changing the ventricular heart cells action potential duration
- Open Access
- 1 October 2013
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 13 (5) , 231-236
Influence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices
Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.
- 1 October 2013
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 13 (5) , 231-236
Open AccessInfluence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices
Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.
- Open Access
- 1 January 2011
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 11 (6)
Application of Wavelet Based Denoising for T-Wave Alternans Analysis in High Resolution ECG Maps
Application of Wavelet Based Denoising for T-Wave Alternans Analysis in High Resolution ECG MapsT-wave alternans (TWA) allows for identification of patients at an increased risk of ventricular arrhythmia. Stress test, which increases heart rate in controlled manner, is used for TWA measurement. However, the TWA detection and analysis are often disturbed by muscular interference. The evaluation of wavelet based denoising methods was performed to find optimal algorithm for TWA analysis. ECG signals recorded in twelve patients with cardiac disease were analyzed. In seven of them significant T-wave alternans magnitude was detected. The application of wavelet based denoising method in the pre-processing stage increases the T-wave alternans magnitude as well as the number of BSPM signals where TWA was detected.
- 1 January 2011
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 11 (6)
Open AccessApplication of Wavelet Based Denoising for T-Wave Alternans Analysis in High Resolution ECG Maps
Application of Wavelet Based Denoising for T-Wave Alternans Analysis in High Resolution ECG MapsT-wave alternans (TWA) allows for identification of patients at an increased risk of ventricular arrhythmia. Stress test, which increases heart rate in controlled manner, is used for TWA measurement. However, the TWA detection and analysis are often disturbed by muscular interference. The evaluation of wavelet based denoising methods was performed to find optimal algorithm for TWA analysis. ECG signals recorded in twelve patients with cardiac disease were analyzed. In seven of them significant T-wave alternans magnitude was detected. The application of wavelet based denoising method in the pre-processing stage increases the T-wave alternans magnitude as well as the number of BSPM signals where TWA was detected.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 327-328
T-wave alternans influence on vectocardiographic parameters
The influence of T-wave alternans (TWA) on vectocardiographic parameters has been presented. Alternations in the length and the angle of T-wave loop vector have been found between odd and even beats in electrocardiograms with detectable T-wave alternans. The study shows the significance of changes of T-wave loop vector length and angle in the process of shaping Twave alternans signal. The aim of the study was to improve TWA detection process. The results showed the advantages of using vectocardiographic analysis for Twave alternans detection.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 327-328
T-wave alternans influence on vectocardiographic parameters
The influence of T-wave alternans (TWA) on vectocardiographic parameters has been presented. Alternations in the length and the angle of T-wave loop vector have been found between odd and even beats in electrocardiograms with detectable T-wave alternans. The study shows the significance of changes of T-wave loop vector length and angle in the process of shaping Twave alternans signal. The aim of the study was to improve TWA detection process. The results showed the advantages of using vectocardiographic analysis for Twave alternans detection.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 721-723
Spatial distribution of T-wave alternans
The aim of the study was a selection of best ECG leads to get the significant T-wave alternans signal (TWA). The group of 16 patients with implantable cardioverter-defibrillator (ICD) was examined. The 64 lead ECG system was used. Three lead sets were analyzed: 64 BSPM lead set, orthogonal lead set (XYZ) and standard 12 lead set. Patients were divided into two groups: TWA positive (TWA(+)) 5 patients and TWA negative (TWA(-)) 11 patients. In TWA(+) group mean alternans ratio was equal 5.4 (SD 8.09) and in TWA(-) group 0.73 (SD 0.26). Both standard ECG leads and XYZ leads are less sensitive to TWA than specially selected leads from 64 lead set.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 721-723
Spatial distribution of T-wave alternans
The aim of the study was a selection of best ECG leads to get the significant T-wave alternans signal (TWA). The group of 16 patients with implantable cardioverter-defibrillator (ICD) was examined. The 64 lead ECG system was used. Three lead sets were analyzed: 64 BSPM lead set, orthogonal lead set (XYZ) and standard 12 lead set. Patients were divided into two groups: TWA positive (TWA(+)) 5 patients and TWA negative (TWA(-)) 11 patients. In TWA(+) group mean alternans ratio was equal 5.4 (SD 8.09) and in TWA(-) group 0.73 (SD 0.26). Both standard ECG leads and XYZ leads are less sensitive to TWA than specially selected leads from 64 lead set.
- 1 July 2007
- Published by Elsevier in Journal of Electrocardiology
- Vol. 40 (4) , S36-S37
Evaluation of the T-wave alternans detection methods—simulation study
- 1 July 2007
- Published by Elsevier in Journal of Electrocardiology
- Vol. 40 (4) , S36-S37
Evaluation of the T-wave alternans detection methods—simulation study
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 499-502
Spatial and temporal variability of ECG waveforms observed in sinus rhythm and during atrio-ventricular stimulation in a patient with implanted ICD: case study
Measurements of surface HR ECG were carried out in an unshielded environment. Signals were acquired from one patient with implanted ICD (implantable cardioverter-defibrillator) during sinus rhythm and during atrial and ventricular stimulation. QRS, STT, QRST deflection areas and T wave alternans were studied. Significant differences between two ventricular activation sequences were found in spatial distributions of QRS and STT integrals in comparison to QRST integral maps, of which spatial distribution was almost independent of activation order. Quantification of differences was done with the use of principal component analysis and correlation coefficient between deflection areas of waveforms. Departure maps were also studied. Beat to beat variations of QRS, STT and QRST deflection areas were calculated and compared to microvolt T-wave alternans test results
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 499-502
Spatial and temporal variability of ECG waveforms observed in sinus rhythm and during atrio-ventricular stimulation in a patient with implanted ICD: case study
Measurements of surface HR ECG were carried out in an unshielded environment. Signals were acquired from one patient with implanted ICD (implantable cardioverter-defibrillator) during sinus rhythm and during atrial and ventricular stimulation. QRS, STT, QRST deflection areas and T wave alternans were studied. Significant differences between two ventricular activation sequences were found in spatial distributions of QRS and STT integrals in comparison to QRST integral maps, of which spatial distribution was almost independent of activation order. Quantification of differences was done with the use of principal component analysis and correlation coefficient between deflection areas of waveforms. Departure maps were also studied. Beat to beat variations of QRS, STT and QRST deflection areas were calculated and compared to microvolt T-wave alternans test results