Rajesh Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajesh Patel has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
S. Sengottuvel
SQUIDs Applications Section, SQUID and Detector Technology Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, India
11 shared publicationsK. Gireesan
SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam, India
10 shared publicationsM. P. Janawadkar
SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam, India
7 shared publicationsT. S. Radhakrishnan
SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam, India
6 shared publications- Sengottuvel Senthilnathan
Indira Gandhi Centre for Atomic Research
4 shared publications - Awadhesh Mani
Indira Gandhi Centre for Atomic Research
2 shared publications
Latest Publications
- 30 July 2025
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 80 (5-6) , 186-190
Performance analysis of blind source separation algorithms in de-noising multichannel magnetocardiogram during rest and stress conditions
Magnetocardiography (MCG) offers a non-contact, non-invasive way of capturing the heart's weak magnetic field signals. MCG measurements often suffer from physiological artifacts, particularly during exercise. Blind source separation algorithms (BSS) are commonly utilized to eliminate noise in multichannel systems. This study assesses the performance of BSS algorithms in noise removal from multichannel MCG recordings under varying physical conditions. We used three BSS algorithms such as fast independent component analysis (Fast ICA), temporally decorrelated source separation (TDSEP), and second order blind identification (SOBI) for noise reduction in different physical conditions of the subject rest, stress, and recovery. It has been observed that Fast ICA demonstrated superior performance in rest conditions, while SOBI exhibited better performance during stress conditions, as evidenced by higher signal-to-noise ratio (SNR) across all cardiac beats. This study helps to explore the possibility of improving the quality of MCG signals, facilitating the cardiac health assessment under different physical conditions, especially for subjects with diverse cardiac abnormalities.
- 30 July 2025
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 80 (5-6) , 186-190
Performance analysis of blind source separation algorithms in de-noising multichannel magnetocardiogram during rest and stress conditions
Magnetocardiography (MCG) offers a non-contact, non-invasive way of capturing the heart's weak magnetic field signals. MCG measurements often suffer from physiological artifacts, particularly during exercise. Blind source separation algorithms (BSS) are commonly utilized to eliminate noise in multichannel systems. This study assesses the performance of BSS algorithms in noise removal from multichannel MCG recordings under varying physical conditions. We used three BSS algorithms such as fast independent component analysis (Fast ICA), temporally decorrelated source separation (TDSEP), and second order blind identification (SOBI) for noise reduction in different physical conditions of the subject rest, stress, and recovery. It has been observed that Fast ICA demonstrated superior performance in rest conditions, while SOBI exhibited better performance during stress conditions, as evidenced by higher signal-to-noise ratio (SNR) across all cardiac beats. This study helps to explore the possibility of improving the quality of MCG signals, facilitating the cardiac health assessment under different physical conditions, especially for subjects with diverse cardiac abnormalities.
- Open Access
- 16 May 2025
- Published by Springer Nature in International Journal of Information Technology
- Vol. 17 (6) , 3213-3220
A feasibility study on non-contact liquid nitrogen level measurement in laboratory settings using machine learning-driven ultrasonic system
Accurate liquid nitrogen level measurement is crucial in cryogenics for safety and optimal storage. Industrial-grade solutions, such as optical fibers and capacitive sensors, are effective but costly and complex, while conventional dipstick methods suffer from heat transfer issues and measurement inaccuracies. This study explores the feasibility of using an ultrasonic sensor for non-contact level detection in an open-mouth laboratory storage setup. By measuring the time of flight of ultrasonic pulses and applying a machine learning model to compensate for environmental fluctuations, the proposed approach offers a non-contact, accurate, and reliable alternative for laboratory applications.
- 16 May 2025
- Published by Springer Nature in International Journal of Information Technology
- Vol. 17 (6) , 3213-3220
Open AccessA feasibility study on non-contact liquid nitrogen level measurement in laboratory settings using machine learning-driven ultrasonic system
Accurate liquid nitrogen level measurement is crucial in cryogenics for safety and optimal storage. Industrial-grade solutions, such as optical fibers and capacitive sensors, are effective but costly and complex, while conventional dipstick methods suffer from heat transfer issues and measurement inaccuracies. This study explores the feasibility of using an ultrasonic sensor for non-contact level detection in an open-mouth laboratory storage setup. By measuring the time of flight of ultrasonic pulses and applying a machine learning model to compensate for environmental fluctuations, the proposed approach offers a non-contact, accurate, and reliable alternative for laboratory applications.
- 13 May 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 43 (8) , 4968-4990
Machine Learning-Based Automated Method for Effective De-noising of Magnetocardiography Signals Using Independent Component Analysis
- 13 May 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 43 (8) , 4968-4990
Machine Learning-Based Automated Method for Effective De-noising of Magnetocardiography Signals Using Independent Component Analysis
- 19 December 2022
- Published by Springer Nature in Sādhanā
- Vol. 47 (4) , 1-12
Optimal classification of N-back task EEG data by performing effective feature reduction
- 19 December 2022
- Published by Springer Nature in Sādhanā
- Vol. 47 (4) , 1-12
Optimal classification of N-back task EEG data by performing effective feature reduction
- 1 November 2022
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Journal of Scientific & Industrial Research
- Vol. 81 (11) , 1181-1185-1185
Combining CEEMDAN with PCA for effective cardiac artifact suppression from single-channel EEG
The large signal due to cardiac activity can easily distort the signals originating from the relatively weak electrical activity of the brain, commonly measured as an Electroencephalogram (EEG). The artifact due to cardiac activity in EEG is called cardiac artifact, which contaminates the EEG data and makes interpretation of the EEG difficult for clinicians. Hence it is crucial to remove the cardiac artifact from EEG data. To suppress the cardiac artifact, we propose a novel approach to effectively extract cardiac artifacts from single-channel contaminated EEG data without using reference Electrocardiogram (EKG) data. The proposed methodology uses Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) to decompose EEG data contaminated by cardiac activity into the Intrinsic Mode Functions (IMFs). Principal Component Analysis (PCA) is performed on these IMFs to obtain the principal components arranged in the order of decreasing variance. Effective cardiac artifact extraction is achieved by optimizing the signal reconstruction process so that only those principal components that capture the cardiac activity are retained with the constraint that distortion introduced in EEG data should be minimum. The comparison clearly shows that the proposed method outperforms conventionally employed methods like wavelet-based approach.
- 1 November 2022
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Journal of Scientific & Industrial Research
- Vol. 81 (11) , 1181-1185-1185
Combining CEEMDAN with PCA for effective cardiac artifact suppression from single-channel EEG
The large signal due to cardiac activity can easily distort the signals originating from the relatively weak electrical activity of the brain, commonly measured as an Electroencephalogram (EEG). The artifact due to cardiac activity in EEG is called cardiac artifact, which contaminates the EEG data and makes interpretation of the EEG difficult for clinicians. Hence it is crucial to remove the cardiac artifact from EEG data. To suppress the cardiac artifact, we propose a novel approach to effectively extract cardiac artifacts from single-channel contaminated EEG data without using reference Electrocardiogram (EKG) data. The proposed methodology uses Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) to decompose EEG data contaminated by cardiac activity into the Intrinsic Mode Functions (IMFs). Principal Component Analysis (PCA) is performed on these IMFs to obtain the principal components arranged in the order of decreasing variance. Effective cardiac artifact extraction is achieved by optimizing the signal reconstruction process so that only those principal components that capture the cardiac activity are retained with the constraint that distortion introduced in EEG data should be minimum. The comparison clearly shows that the proposed method outperforms conventionally employed methods like wavelet-based approach.
- 12 July 2021
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (7) , 4001-4011
Solving Inverse Problem in Magnetocardiography by Pattern Search Method
In this paper, we report a novel way of choosing the initial estimates for solving magnetocardiographic inverse problems using the pattern search method. As opposed to the conventional choice of pseudo random numbers, the co-ordinates of the maximum spatial gradient of magnetic fields across sensor locations were used as initial estimates for pattern search method with the help of current density maps. The proposed method has been extensively validated by computer simulation and test coil localization before applying to real magnetocardiogram of a few healthy subjects and those with a known conduction anomaly and ischemic heart disease.
- 12 July 2021
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (7) , 4001-4011
Solving Inverse Problem in Magnetocardiography by Pattern Search Method
In this paper, we report a novel way of choosing the initial estimates for solving magnetocardiographic inverse problems using the pattern search method. As opposed to the conventional choice of pseudo random numbers, the co-ordinates of the maximum spatial gradient of magnetic fields across sensor locations were used as initial estimates for pattern search method with the help of current density maps. The proposed method has been extensively validated by computer simulation and test coil localization before applying to real magnetocardiogram of a few healthy subjects and those with a known conduction anomaly and ischemic heart disease.
- Open Access
- 1 October 2018
- Published by Elsevier in SLAS Technology
- Vol. 23 (5) , 463-469
Designing a Low-Cost, Single-Supply ECG System for Suppression of Movement Artifact from Contaminated Magnetocardiogram
- 1 October 2018
- Published by Elsevier in SLAS Technology
- Vol. 23 (5) , 463-469
Open AccessDesigning a Low-Cost, Single-Supply ECG System for Suppression of Movement Artifact from Contaminated Magnetocardiogram
- Open Access
- 10 February 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (2) , 318
Correction to: Common Methodology for Cardiac and Ocular Artifact Suppression from EEG Recordings by Combining Ensemble Empirical Mode Decomposition with Regression Approach
- 10 February 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (2) , 318
Open AccessCorrection to: Common Methodology for Cardiac and Ocular Artifact Suppression from EEG Recordings by Combining Ensemble Empirical Mode Decomposition with Regression Approach
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1942 (1) , 060018
Feasibility study on measurement of magnetocardiography (MCG) using fluxgate magnetometer
This paper reports the feasibility of measuring weak magnetic fields generated by the electrical activity of the heart using a portable tri-axial fluxgate magnetometer inside a magnetically shielded room. Measurement of Magnetocardiogram (MCG) signals could be successfully demonstrated from a healthy subject using a novel set-up involving a reference fluxgate sensor which simultaneously measures the magnetic fields associated with the ECG waveform measured on the same subject. The timing information provided by R wave peaks of ECG recorded by the reference sensor is utilized to generate trigger locked average of the sensor output of the measurement fluxgate, and extract MCG signals in all the three orthogonal directions (X, Y and Z) on the anterior thorax. It is expected that such portable room temperature measurements using fluxgate sensor could assist in validating the direction of the equivalent current dipole associated with the electrical activity of the human heart. This is somewhat difficult in conventional MCG measurements using SQUID sensors, which usually furnish only the z component of the magnetic field and its spatial derivatives.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1942 (1) , 060018
Feasibility study on measurement of magnetocardiography (MCG) using fluxgate magnetometer
This paper reports the feasibility of measuring weak magnetic fields generated by the electrical activity of the heart using a portable tri-axial fluxgate magnetometer inside a magnetically shielded room. Measurement of Magnetocardiogram (MCG) signals could be successfully demonstrated from a healthy subject using a novel set-up involving a reference fluxgate sensor which simultaneously measures the magnetic fields associated with the ECG waveform measured on the same subject. The timing information provided by R wave peaks of ECG recorded by the reference sensor is utilized to generate trigger locked average of the sensor output of the measurement fluxgate, and extract MCG signals in all the three orthogonal directions (X, Y and Z) on the anterior thorax. It is expected that such portable room temperature measurements using fluxgate sensor could assist in validating the direction of the equivalent current dipole associated with the electrical activity of the human heart. This is somewhat difficult in conventional MCG measurements using SQUID sensors, which usually furnish only the z component of the magnetic field and its spatial derivatives.