Jacqui Robinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jacqui Robinson has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- John Eric Deanfield
Institute of Cardiovascular Science, University College London, London, UK
10 shared publications David S. Celermajer
9 shared publicationsMark R. Adams
From the Departments of Cardiology (S.M.H., J.T.C.R., R.J.M., M.R.A., D.S.C.) and Medical Oncology (M.J.B.), Royal Prince Alfred Hospital, and the Heart Research Institute (J.T.C.R., R.J.M., D.S.C.), Sydney, Australia
7 shared publicationsD S Celermajer
4 shared publicationsAndrew P. Hopkins
Department of Cardiology, Liverpool Hospital, Liverpool BC, New South Wales, Australia
3 shared publicationsD.S. Celermajer
3 shared publications
Latest Publications
- 21 October 2016
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 61 (1) , 31-38
Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery
Background: It remains unclear whether measuring carotid arterial flow by the time velocity integral using vascular Doppler ultrasound can be used to monitor cardiac output and volume responsiveness.Methods: The carotid Doppler flow (time velocity integral and peak flow velocity variation) was assessed in triplicate by an intensivist with formal vascular ultrasound training. Thirty‐three patients admitted following coronary by‐pass surgery were studied before and after a passive leg‐raising manoeuvre to investigate volume responsiveness (more than 10% increase in cardiac output) along with indices of arterial load measuring cardiac output by thermodilution. Pearson's correlation coefficient and area under the curve (AUC) by receiver operating characteristics were calculated.Results: A significant correlation between carotid Doppler flow and cardiac output was demonstrated in post‐operative cardiac surgery patients (r = 0.80 [95%CI 0.61–0.89]), including relative changes following passive leg raising (r = 0.79 [95%CI 0.60–0.89]) that showed a mean difference of 2% with wide limits of agreements (−19% to 16%). Changes in carotid Doppler flow following passive leg raising correlated with the baseline arterial resistance but not with compliance or effective elastance. A peak flow variation > 10% before passive leg raising discriminated responders to the manoeuvre with an AUC of 0.81 [95% CI 0.55–0.95].Conclusions: Weak correlations between common carotid Doppler flow and cardiac output mean that the methods cannot be used interchangeably in post‐operative cardiac surgery patients.
- 21 October 2016
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 61 (1) , 31-38
Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery
Background: It remains unclear whether measuring carotid arterial flow by the time velocity integral using vascular Doppler ultrasound can be used to monitor cardiac output and volume responsiveness.Methods: The carotid Doppler flow (time velocity integral and peak flow velocity variation) was assessed in triplicate by an intensivist with formal vascular ultrasound training. Thirty‐three patients admitted following coronary by‐pass surgery were studied before and after a passive leg‐raising manoeuvre to investigate volume responsiveness (more than 10% increase in cardiac output) along with indices of arterial load measuring cardiac output by thermodilution. Pearson's correlation coefficient and area under the curve (AUC) by receiver operating characteristics were calculated.Results: A significant correlation between carotid Doppler flow and cardiac output was demonstrated in post‐operative cardiac surgery patients (r = 0.80 [95%CI 0.61–0.89]), including relative changes following passive leg raising (r = 0.79 [95%CI 0.60–0.89]) that showed a mean difference of 2% with wide limits of agreements (−19% to 16%). Changes in carotid Doppler flow following passive leg raising correlated with the baseline arterial resistance but not with compliance or effective elastance. A peak flow variation > 10% before passive leg raising discriminated responders to the manoeuvre with an AUC of 0.81 [95% CI 0.55–0.95].Conclusions: Weak correlations between common carotid Doppler flow and cardiac output mean that the methods cannot be used interchangeably in post‐operative cardiac surgery patients.
- Open Access
- 3 December 2015
- Published by Wiley in Sonography
- Vol. 2 (4) , 101-102
Inside ultrasound vascular reference guide
- 3 December 2015
- Published by Wiley in Sonography
- Vol. 2 (4) , 101-102
Open AccessInside ultrasound vascular reference guide
- 1 December 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 66 (4) , 528-534
Comparison of 6 and 7 French guiding catheters for percutaneous coronary intervention: Results of a randomised trial with a vascular ultrasound endpoint
Objective: To perform a randomized, ultrasound controlled trial to define the procedural and clinical advantages and limitations of 6 French (Fr) compared with 7 Fr transfemoral coronary intervention in the stenting era. Background: The use of 7 Fr guiding catheters may facilitate Percutaneous Coronary Intervention (PCI), but may be associated with increased vascular complications when compared with 6 Fr catheters. Methods: Patients undergoing PCI considered suitable for either a 6 or 7 Fr sheath and guiding catheter system were included. All vascular sheaths were removed with assisted manual compression. Femoral vascular ultrasounds were performed prior to hospital discharge and interpreted by a vascular surgeon blinded to treatment assignment. The primary endpoint was a composite of significant vascular complications including major haematoma, retroperitoneal haematoma, pseudoaneurysm, arterio–venous fistula, or femoral venous or arterial thrombosis. Results: During the study, 414 patients (mean age 61 ± 11 years, 27% females) were randomly assigned to 6 Fr or 7 Fr sheath groups. The incidence of major vascular complications was 5.7% in the 6 Fr group and 3.9% in the 7 Fr group (P = 0.383). There was no significant difference in procedural or angiographic success between the groups. The use of contrast volume was higher in the 7 Fr group (157 ± 58 ml vs. 144 ± 58 ml; P = 0.029). There was a trend toward better operator satisfaction with the 7 Fr guide (P = 0.08). Conclusions: This prospective, randomized trial indicates no reduction in major peripheral vascular complications with the use of smaller guiding catheters in PCI. There was less contrast used in the 6 Fr group, which may benefit some patient subsets, however operators tended to prefer the larger 7 Fr system. The target coronary anatomy and need for complex device intervention should mandate the choice of guiding catheter size, not a perceived impact on vascular complications.
- 1 December 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 66 (4) , 528-534
Comparison of 6 and 7 French guiding catheters for percutaneous coronary intervention: Results of a randomised trial with a vascular ultrasound endpoint
Objective: To perform a randomized, ultrasound controlled trial to define the procedural and clinical advantages and limitations of 6 French (Fr) compared with 7 Fr transfemoral coronary intervention in the stenting era. Background: The use of 7 Fr guiding catheters may facilitate Percutaneous Coronary Intervention (PCI), but may be associated with increased vascular complications when compared with 6 Fr catheters. Methods: Patients undergoing PCI considered suitable for either a 6 or 7 Fr sheath and guiding catheter system were included. All vascular sheaths were removed with assisted manual compression. Femoral vascular ultrasounds were performed prior to hospital discharge and interpreted by a vascular surgeon blinded to treatment assignment. The primary endpoint was a composite of significant vascular complications including major haematoma, retroperitoneal haematoma, pseudoaneurysm, arterio–venous fistula, or femoral venous or arterial thrombosis. Results: During the study, 414 patients (mean age 61 ± 11 years, 27% females) were randomly assigned to 6 Fr or 7 Fr sheath groups. The incidence of major vascular complications was 5.7% in the 6 Fr group and 3.9% in the 7 Fr group (P = 0.383). There was no significant difference in procedural or angiographic success between the groups. The use of contrast volume was higher in the 7 Fr group (157 ± 58 ml vs. 144 ± 58 ml; P = 0.029). There was a trend toward better operator satisfaction with the 7 Fr guide (P = 0.08). Conclusions: This prospective, randomized trial indicates no reduction in major peripheral vascular complications with the use of smaller guiding catheters in PCI. There was less contrast used in the 6 Fr group, which may benefit some patient subsets, however operators tended to prefer the larger 7 Fr system. The target coronary anatomy and need for complex device intervention should mandate the choice of guiding catheter size, not a perceived impact on vascular complications.
- 23 September 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 63 (2) , 166-170
Patient tolerance and resource utilization associated with an arterial closure versus an external compression device after percutaneous coronary intervention
We assessed patient tolerance and resource utilization of using the AngioSeal closure device versus assisted manual compression using the Femostop device after percutaneous coronary intervention (PCI). Patients undergoing PCI with clean arterial access and no procedural hematoma were randomized to receive the AngioSeal or Femostop device to achieve femoral arterial hemostasis. Times from procedure end to removal from angiography table, hemostasis, ambulation, and hospital discharge were recorded. Bedside nursing/medical officer care time, vascular complications, and disposable use were also documented. Patient comfort was assessed using Present Pain Intensity and Visual Analogue scales at baseline, 4 hr, 8 hr, and the morning after the procedure. One hundred twenty‐two patients were enrolled (62 AngioSeal, 60 Femostop). Patients in the AngioSeal group took longer to be removed from the angiography table (11 ± 4 vs. 9 ± 3 min; P = 0.002) compared with the Femostop group. Time to hemostasis (0.4 ± 1.1 vs. 6.4 ± 1.7 hr; P < 0.001) and ambulation (17 ± 8 vs. 22 ± 13 hr; P = 0.004) were less in the AngioSeal group, although time to discharge was not different. Nursing and medical officer time was no different. Disposables including device cost were higher in the AngioSeal group ($209 ± 13 vs. $53 ± 9; P < 0.001). On a Visual Analogue scale, patients reported more pain at 4 hr (P < 0.001) and 8 hr (P < 0.001) in the Femostop group. The worst amount of pain at any time point was also more severe in the Femostop group (P < 0.001). Similar results were found on a Present Pain Intensity scale of pain. There were no differences in ultrasound‐determined vascular complications (two each). Femoral access site closure using the AngioSeal device resulted in a small delay in leaving the angiography suite and a higher disposable cost compared to using the Femostop device. However, patients receiving the AngioSeal were able to ambulate sooner and reported less pain, which may justify the increased costs involved. Catheter Cardiovasc Interv 2004;63:166–170.
- 23 September 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 63 (2) , 166-170
Patient tolerance and resource utilization associated with an arterial closure versus an external compression device after percutaneous coronary intervention
We assessed patient tolerance and resource utilization of using the AngioSeal closure device versus assisted manual compression using the Femostop device after percutaneous coronary intervention (PCI). Patients undergoing PCI with clean arterial access and no procedural hematoma were randomized to receive the AngioSeal or Femostop device to achieve femoral arterial hemostasis. Times from procedure end to removal from angiography table, hemostasis, ambulation, and hospital discharge were recorded. Bedside nursing/medical officer care time, vascular complications, and disposable use were also documented. Patient comfort was assessed using Present Pain Intensity and Visual Analogue scales at baseline, 4 hr, 8 hr, and the morning after the procedure. One hundred twenty‐two patients were enrolled (62 AngioSeal, 60 Femostop). Patients in the AngioSeal group took longer to be removed from the angiography table (11 ± 4 vs. 9 ± 3 min; P = 0.002) compared with the Femostop group. Time to hemostasis (0.4 ± 1.1 vs. 6.4 ± 1.7 hr; P < 0.001) and ambulation (17 ± 8 vs. 22 ± 13 hr; P = 0.004) were less in the AngioSeal group, although time to discharge was not different. Nursing and medical officer time was no different. Disposables including device cost were higher in the AngioSeal group ($209 ± 13 vs. $53 ± 9; P < 0.001). On a Visual Analogue scale, patients reported more pain at 4 hr (P < 0.001) and 8 hr (P < 0.001) in the Femostop group. The worst amount of pain at any time point was also more severe in the Femostop group (P < 0.001). Similar results were found on a Present Pain Intensity scale of pain. There were no differences in ultrasound‐determined vascular complications (two each). Femoral access site closure using the AngioSeal device resulted in a small delay in leaving the angiography suite and a higher disposable cost compared to using the Femostop device. However, patients receiving the AngioSeal were able to ambulate sooner and reported less pain, which may justify the increased costs involved. Catheter Cardiovasc Interv 2004;63:166–170.
- 1 January 2003
- Published by Wiley in Heart, Lung and Circulation
- Vol. 12 (2) , A96-A97
Patient tolerance and resource implications of the use of the angioseal™ device after percutaneous coronary intervention
- 1 January 2003
- Published by Wiley in Heart, Lung and Circulation
- Vol. 12 (2) , A96-A97
Patient tolerance and resource implications of the use of the angioseal™ device after percutaneous coronary intervention
- 1 July 1998
- Published by S. Karger AG in Hormone Research in Paediatrics
- Vol. 50 (Suppl. 1) , 38-40
Macroangiopathy – Does It Play a Role in Young People?
Using a novel ultrasound method, brachial artery endothelial and smooth muscle physiology were studied in 20 adolescents with IDDM and in 20 nondiabetic subjects matched for age (13–22 years), gender and vessel size. Endothelium-dependent dilatation (EDD) was assessed in response to flow (EDD) and endothelium-independent vasodilatation after sublingual glyceryl trinitrate (GTN). Both EDD and GTN were reduced in those with IDDM compared with controls: 5 vs. 9%, (p = 0.0002) and 14 vs. 21% (p = 0.002). Abnormal EDD was found in 12 IDDM adolescents (diabetes duration 3.3–14.9 years). The mean urinary albumin excretion rate of the diabetic group with abnormal EDD was 5.76 ± 2.82 vs. 8.05 ± 4.88 µg/min in those with normal EDD (p = 0.25). In the diabetic adolescents there was no significant correlation observed between the test for early large vessel disease, HbA1c and tests for diabetic microangiopathy.
- 1 July 1998
- Published by S. Karger AG in Hormone Research in Paediatrics
- Vol. 50 (Suppl. 1) , 38-40
Macroangiopathy – Does It Play a Role in Young People?
Using a novel ultrasound method, brachial artery endothelial and smooth muscle physiology were studied in 20 adolescents with IDDM and in 20 nondiabetic subjects matched for age (13–22 years), gender and vessel size. Endothelium-dependent dilatation (EDD) was assessed in response to flow (EDD) and endothelium-independent vasodilatation after sublingual glyceryl trinitrate (GTN). Both EDD and GTN were reduced in those with IDDM compared with controls: 5 vs. 9%, (p = 0.0002) and 14 vs. 21% (p = 0.002). Abnormal EDD was found in 12 IDDM adolescents (diabetes duration 3.3–14.9 years). The mean urinary albumin excretion rate of the diabetic group with abnormal EDD was 5.76 ± 2.82 vs. 8.05 ± 4.88 µg/min in those with normal EDD (p = 0.25). In the diabetic adolescents there was no significant correlation observed between the test for early large vessel disease, HbA1c and tests for diabetic microangiopathy.
- 31 October 1997
- Published by Elsevier in Atherosclerosis
- Vol. 134 (1) , 172
2.P.268 Aging, smoking and hypercholesterolaemia have a less impact on endothelial function in the Chinese than Caucasian
- 31 October 1997
- Published by Elsevier in Atherosclerosis
- Vol. 134 (1) , 172
2.P.268 Aging, smoking and hypercholesterolaemia have a less impact on endothelial function in the Chinese than Caucasian
- 1 October 1997
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 17 (10) , 2004-2009
Androgen Deprivation Is Associated With Enhanced Endothelium-Dependent Dilatation in Adult Men
Male gender is an independent risk factor for coronary artery disease, and androgen administration has been associated with increased atherosclerosis in experimental animals. Since endothelial dysfunction is an important event in the atherogenic process, we hypothesized that androgen deprivation in adult men might be associated with enhanced arterial endothelial function. Using external vascular ultrasound, brachial artery diameter was measured at rest, after flow increase (causing endothelium-dependent dilatation) and after nitroglycerin (an endothelium-independent dilator). We studied 30 adult males aged 40 to 70 years: 10 had had bilateral orchidectomy and/or maximal androgen blockade for ≥6 months for treatment of prostate cancer, and all were in complete remission (group 1). Ten healthy controls (group 2) and 10 controls who had remission from nonprostate cancers (group 3) were matched for age and smoking history. Testosterone levels were lower in men in group 1 versus groups 2 or 3 (0.8±0.1 versus 19.2±8.4 or 16.1±4.9 nmol/L,P<.001). By contrast, endothelium-dependent dilatation was markedly higher in group 1 than in groups 2 or 3 (6.2±3 versus 2.7±2 or 2.0±1.9%,P<.001). The nitroglycerin response was similar in all three groups (P=.92). On multivariate analysis, increased endothelium-dependent dilatation was significantly associated with low serum testosterone levels (P=.001) but not with cholesterol levels or with a past history of malignancy (P>.25). The withdrawal of male sex hormones may be associated with enhanced endothelial function in adult men. This is consistent with a deleterious effect of physiologic levels of male sex steroids on the arterial wall.
- 1 October 1997
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 17 (10) , 2004-2009
Androgen Deprivation Is Associated With Enhanced Endothelium-Dependent Dilatation in Adult Men
Male gender is an independent risk factor for coronary artery disease, and androgen administration has been associated with increased atherosclerosis in experimental animals. Since endothelial dysfunction is an important event in the atherogenic process, we hypothesized that androgen deprivation in adult men might be associated with enhanced arterial endothelial function. Using external vascular ultrasound, brachial artery diameter was measured at rest, after flow increase (causing endothelium-dependent dilatation) and after nitroglycerin (an endothelium-independent dilator). We studied 30 adult males aged 40 to 70 years: 10 had had bilateral orchidectomy and/or maximal androgen blockade for ≥6 months for treatment of prostate cancer, and all were in complete remission (group 1). Ten healthy controls (group 2) and 10 controls who had remission from nonprostate cancers (group 3) were matched for age and smoking history. Testosterone levels were lower in men in group 1 versus groups 2 or 3 (0.8±0.1 versus 19.2±8.4 or 16.1±4.9 nmol/L,P<.001). By contrast, endothelium-dependent dilatation was markedly higher in group 1 than in groups 2 or 3 (6.2±3 versus 2.7±2 or 2.0±1.9%,P<.001). The nitroglycerin response was similar in all three groups (P=.92). On multivariate analysis, increased endothelium-dependent dilatation was significantly associated with low serum testosterone levels (P=.001) but not with cholesterol levels or with a past history of malignancy (P>.25). The withdrawal of male sex hormones may be associated with enhanced endothelial function in adult men. This is consistent with a deleterious effect of physiologic levels of male sex steroids on the arterial wall.
- 1 September 1997
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 127 (5) , 372-375
Differences in the Effect of Cigarette Smoking on Endothelial Function in Chinese and White Adults
The prevalence of coronary artery disease in southern China is approximately one fifth that in “westernized” countries, even though approximately 70% of Chinese men smoke cigarettes and Chinese women have substantial passive exposure to cigarette smoke. Endothelial dysfunction is an early event in atherosclerosis and occurs in young white active and passive smokers; we compared endothelial physiology in healthy young Chinese and white smokers and nonsmokers. 144 healthy adults who were 16 to 45 years of age: 72 Chinese persons in a village in southern China and 72 white persons in Australia and England who were matched for exposure to cigarette smoke. Each ethnic group comprised 36 controls (lifelong nonsmokers with no regular exposure to cigarette smoke; 16 men and 20 women) and 36 active or passive smokers (15 men and 21 women). Arterial endothelial function was tested with high-resolution external vascular ultrasonography, and brachial artery diameter was measured at rest, after flow increase (which causes endothelium-dependent dilatation), and after administration of sublingual nitroglycerin (an endothelium-independent dilator). Endothelium-dependent dilatation was similar in Chinese (7.9%) and white (8.4%) nonsmokers (P > 0.2). Among white persons, endothelium-dependent dilatation was lower in active or passive smokers (3.9%) than in nonsmokers (8.4%) (P < 0.001). Among Chinese persons, dilatation was not significantly lower in active or passive smokers (7.3%) than in nonsmokers (7.9%) (P > 0.2). Dilatation was higher in Chinese active or passive smokers (7.3%) than in white active or passive smokers (3.9%) (P < 0.001). Dilatation responses to nitroglycerin were similar in all groups (P = 0.17). Young Chinese adults have less evidence of arterial endothelial dysfunction than young white adults with similar direct or indirect exposure to cigarette smoke.
- 1 September 1997
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 127 (5) , 372-375
Differences in the Effect of Cigarette Smoking on Endothelial Function in Chinese and White Adults
The prevalence of coronary artery disease in southern China is approximately one fifth that in “westernized” countries, even though approximately 70% of Chinese men smoke cigarettes and Chinese women have substantial passive exposure to cigarette smoke. Endothelial dysfunction is an early event in atherosclerosis and occurs in young white active and passive smokers; we compared endothelial physiology in healthy young Chinese and white smokers and nonsmokers. 144 healthy adults who were 16 to 45 years of age: 72 Chinese persons in a village in southern China and 72 white persons in Australia and England who were matched for exposure to cigarette smoke. Each ethnic group comprised 36 controls (lifelong nonsmokers with no regular exposure to cigarette smoke; 16 men and 20 women) and 36 active or passive smokers (15 men and 21 women). Arterial endothelial function was tested with high-resolution external vascular ultrasonography, and brachial artery diameter was measured at rest, after flow increase (which causes endothelium-dependent dilatation), and after administration of sublingual nitroglycerin (an endothelium-independent dilator). Endothelium-dependent dilatation was similar in Chinese (7.9%) and white (8.4%) nonsmokers (P > 0.2). Among white persons, endothelium-dependent dilatation was lower in active or passive smokers (3.9%) than in nonsmokers (8.4%) (P < 0.001). Among Chinese persons, dilatation was not significantly lower in active or passive smokers (7.3%) than in nonsmokers (7.9%) (P > 0.2). Dilatation was higher in Chinese active or passive smokers (7.3%) than in white active or passive smokers (3.9%) (P < 0.001). Dilatation responses to nitroglycerin were similar in all groups (P = 0.17). Young Chinese adults have less evidence of arterial endothelial dysfunction than young white adults with similar direct or indirect exposure to cigarette smoke.