Martin Gilar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Gilar has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- John C. Gebler
Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
13 shared publications - Květa Kalíková
Department of Physical and Macromolecular Chemistry, Charles University, Prague, Czech Republic
7 shared publications Thomas S. McDonald
Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
7 shared publicationsFabrice Gritti
Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
6 shared publicationsAleksander Jaworski
51 Palomino Drive, Franklin, MA 02038, USA
5 shared publications- Fabrice Gritti
Waters Corporation, Core Research/Fundamental, Milford, MA, 01757, USA
4 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Wiley in Analytical Science Advances
- Vol. 7 (2) , e70113
Recent Advances in Reversed‐Phase Liquid Chromatography for Therapeutic Oligonucleotide and Conjugate Characterization: From Ion‐Pairing to Green Analytical Approaches
Therapeutic oligonucleotides (ONs) have rapidly emerged as a novel class of treatments in the pharmaceutical industry, with over 25 medicines approved in the past decade. Ion‐pair reversed‐phase liquid chromatography coupled with mass spectrometry (IP‐RPLC‐MS) is widely used method for ON characterization. This review critically examines the state‐of‐the‐art developments in IP‐RPLC‐MS for ON analysis, with particular focus on the selection of optimal chromatographic conditions for three key applications: impurity profiling for single‐stranded ON, characterization of novel conjugates (e.g., lipid‐and peptide‐conjugated ONs) and double‐stranded siRNA analysis in non‐denaturing conditions. Finally, recent developments in ion‐pair‐free RPLC are discussed in the context of pharmaceutical and bioanalytical applications.
- 26 October 2026
- Published by Wiley in Analytical Science Advances
- Vol. 7 (2) , e70113
Open AccessRecent Advances in Reversed‐Phase Liquid Chromatography for Therapeutic Oligonucleotide and Conjugate Characterization: From Ion‐Pairing to Green Analytical Approaches
Therapeutic oligonucleotides (ONs) have rapidly emerged as a novel class of treatments in the pharmaceutical industry, with over 25 medicines approved in the past decade. Ion‐pair reversed‐phase liquid chromatography coupled with mass spectrometry (IP‐RPLC‐MS) is widely used method for ON characterization. This review critically examines the state‐of‐the‐art developments in IP‐RPLC‐MS for ON analysis, with particular focus on the selection of optimal chromatographic conditions for three key applications: impurity profiling for single‐stranded ON, characterization of novel conjugates (e.g., lipid‐and peptide‐conjugated ONs) and double‐stranded siRNA analysis in non‐denaturing conditions. Finally, recent developments in ion‐pair‐free RPLC are discussed in the context of pharmaceutical and bioanalytical applications.
- Open Access
- 23 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (33) , 24117-24125
On-Column Preparation of High-Performance Affinity Chromatography Columns
We describe a custom preparation of high-performance affinity columns based on 3.5 μm nonporous polymeric particles covalently modified with streptavidin. The sorbent was packed into a 2.1 × 20 mm column hardware compatible with pressures up to 10,000 psi (68 MPa). Biotinylated affinity ligands were then immobilized on-column using a repetitive injection method until the streptavidin sorbent was saturated. The saturation was observed as a ligand breakthrough signal by ultraviolet detection. Column binding capacity of immobilized affinity ligands was estimated for d-biotin, biotinylated 25nt oligodeoxythymidine, and biotinylated anti-insulin mAb ligands. The prepared columns were used to quantify mRNA and insulin. Affinity column performance was evaluated in terms of binding capacity, calibration linearity range, and target analyte limit of quantitation. The high-performance streptavidin column is a platform for custom-made affinity chromatography device preparation, enabling routine quantitation of analytes of interest.
- 23 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (33) , 24117-24125
Open AccessOn-Column Preparation of High-Performance Affinity Chromatography Columns
We describe a custom preparation of high-performance affinity columns based on 3.5 μm nonporous polymeric particles covalently modified with streptavidin. The sorbent was packed into a 2.1 × 20 mm column hardware compatible with pressures up to 10,000 psi (68 MPa). Biotinylated affinity ligands were then immobilized on-column using a repetitive injection method until the streptavidin sorbent was saturated. The saturation was observed as a ligand breakthrough signal by ultraviolet detection. Column binding capacity of immobilized affinity ligands was estimated for d-biotin, biotinylated 25nt oligodeoxythymidine, and biotinylated anti-insulin mAb ligands. The prepared columns were used to quantify mRNA and insulin. Affinity column performance was evaluated in terms of binding capacity, calibration linearity range, and target analyte limit of quantitation. The high-performance streptavidin column is a platform for custom-made affinity chromatography device preparation, enabling routine quantitation of analytes of interest.
- 24 September 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1761, 466404
Impact of column selection for the analysis of 3mer phosphorothioated oligonucleotides in hydrophilic interaction liquid chromatography
- 24 September 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1761, 466404
Impact of column selection for the analysis of 3mer phosphorothioated oligonucleotides in hydrophilic interaction liquid chromatography
- Open Access
- 14 April 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1753, 465968
Impact of nucleotide hydrophobicity on oligonucleotides separation in liquid chromatography
- 14 April 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1753, 465968
Open AccessImpact of nucleotide hydrophobicity on oligonucleotides separation in liquid chromatography
- Open Access
- 17 August 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1733, 465285
Impact of mobile and stationary phases on siRNA duplex stability in liquid chromatography
- 17 August 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1733, 465285
Open AccessImpact of mobile and stationary phases on siRNA duplex stability in liquid chromatography
- 11 June 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1730, 465074
Impact of ion-pairing systems choice on diastereomeric selectivity of phosphorothioated oligonucleotides in reversed-phase liquid chromatography
- 11 June 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1730, 465074
Impact of ion-pairing systems choice on diastereomeric selectivity of phosphorothioated oligonucleotides in reversed-phase liquid chromatography
- Open Access
- 26 October 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1712, 464475
Ion-pair reversed-phase and hydrophilic interaction chromatography methods for analysis of phosphorothioate oligonucleotides
- 26 October 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1712, 464475
Open AccessIon-pair reversed-phase and hydrophilic interaction chromatography methods for analysis of phosphorothioate oligonucleotides
- Open Access
- 11 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (38) , 14308-14316
Liquid Chromatography Methods for Analysis of mRNA Poly(A) Tail Length and Heterogeneity
Messenger RNA (mRNA) is a new class of therapeutic compounds. The current advances in mRNA technology require the development of efficient analytical methods. In this work, we describe the development of several methods for measurement of mRNA poly(A) tail length and heterogeneity. Poly(A) tail was first cleaved from mRNA with the RNase T1 enzyme. The average length of a liberated poly(A) tail was analyzed with the size exclusion chromatography method. Size heterogeneity of the poly(A) tail was estimated with high-resolution ion-pair reversed phase liquid chromatography (IP RP LC). The IP RP LC method provides resolution of poly(A) tail oligonucleotide variants up to 150 nucleotide long. Both methods use a robust ultraviolet detection suitable for mRNA analysis in quality control laboratories. The results were confirmed by the LC-mass spectrometry (LC MS) analysis of the same mRNA sample. The poly(A) tail length and heterogeneity results were in good agreement.
- 11 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (38) , 14308-14316
Open AccessLiquid Chromatography Methods for Analysis of mRNA Poly(A) Tail Length and Heterogeneity
Messenger RNA (mRNA) is a new class of therapeutic compounds. The current advances in mRNA technology require the development of efficient analytical methods. In this work, we describe the development of several methods for measurement of mRNA poly(A) tail length and heterogeneity. Poly(A) tail was first cleaved from mRNA with the RNase T1 enzyme. The average length of a liberated poly(A) tail was analyzed with the size exclusion chromatography method. Size heterogeneity of the poly(A) tail was estimated with high-resolution ion-pair reversed phase liquid chromatography (IP RP LC). The IP RP LC method provides resolution of poly(A) tail oligonucleotide variants up to 150 nucleotide long. Both methods use a robust ultraviolet detection suitable for mRNA analysis in quality control laboratories. The results were confirmed by the LC-mass spectrometry (LC MS) analysis of the same mRNA sample. The poly(A) tail length and heterogeneity results were in good agreement.
- 7 September 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1681, 463473
Phosphorothioate oligonucleotides separation in ion-pairing reversed-phase liquid chromatography: effect of temperature
- 7 September 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1681, 463473
Phosphorothioate oligonucleotides separation in ion-pairing reversed-phase liquid chromatography: effect of temperature