AMAbdollah Mehrpanahi

Abdollah Mehrpanahi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abdollah Mehrpanahi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Linear Transfer Functions Extraction for a Power Generation Three-Shaft Gas Turbine Based on Actual Specifications

    by Abdollah Mehrpanahi, Gholamhassan Payganeh, Mohammadreza Arbabtafti

    The design and testing of various types of controllers require accurate and reliable transfer functions that are compatible with the performance condition of the system. In this paper, the linear and the nonlinear methods have been utilized for extracting the transfer functions for a three-shaft industrial gas turbine. The main variables are the fuel input and environment temperature, while the main outputs are the LPT exhaust gas temperature and the generated power. According to the nonlinear structure of the system and the input variation intervals, the quasi-amplitude-modulated pseudo random binary sequence signals have been utilized for generating input parameters. Finally, the results extracted from the selected methods were compared to the outputs of real performance data under loading and unloading conditions. Based on the comparison between the accuracies obtained by the results, the auto-regressive moving average with eXogenous, try and error transfer function and linearized Hammerstein model methods are proposed, respectively. The outcome of using the controller indicated higher compatibility from transfer functions as compared to the reference dynamic model.

  • Robust controller design for a three-shaft industrial gas turbine in the infinite grid power generation

    by Abdollah Mehrpanahi, Mohammadreza Arbabtafti, Gholamhassan Payganeh

    Due to the sensitivity of gas turbines’ power generation in Iran, robustness is considered as a crucial matter and the controllers play an essential role in this objective. The common controllers used in gas turbines are usually based on standard performance. Whereas, robust controllers demonstrate acceptable performance in the presence of adverse factors such as uncertainties, disturbances, and input step changes. In this study, dynamic structures and various robust control design scenarios for an MGT-30 three-shaft gas turbine have proposed. Input-output matrices have been presented based on the dynamic model structures, and a standard robust controller structure has been used to design and present transfer matrices. Four scenarios have been considered in the robust control design according to the number of control variables, uncertainties, and disturbance effects, evolutionally, respectively. H∞ and H2/H∞ methods were used in the controller design when presenting the results of using the existing PID controller. The results show that with the increase and develop in parameters influencing the production of the actual system behavior and the controller responses improve noticeably. Finally, the fourth scenario was proposed as a scenario with more desirable robustness features than other scenarios, which provide a complete array of robust controllers.


  • Improved criteria for stall-free preliminary design of axial compressor of aero gas turbine engines

    by Aligoodarz, A Mehrpanahi, M Moshtaghzadeh, A Hashiehbaf

    A worldwide effort has been devoted to developing highly efficient and reliable gas turbine engines. There exist many prominent factors in the development of these engines. One of the most important features of the optimal design of axial flow compressors is satisfying the allowable range for various parameters such as flow coefficient, stage loading, the degree of reaction, De-Haller number, etc. But, there are some applicable cases that the mentioned criteria are exceeded. One of the most famous parameters is De-Haller number, which according to literature data should not be kept less than 0.72 in any stage of the axial compressor. A deep insight into the current small- or large-scale axial flow compressors shows that a discrepancy will occur among design criterion for De-Haller number and experimental measurements in which the De-Haller number is less than the design limit but no stall or surge is observed. In this paper, an improved formulation is derived based on one-dimensional modeling for predicting the stall-free design parameter ranges especially stage loading, flow coefficient, etc. for various combinations. It was found that the current criterion is much more accurate than the De-Haller criterion for design purposes.


  • Semi-Simplified Black-Box Dynamic Modeling of an Industrial Gas Turbine Based on Real Performance Characteristics

    by Abdollah Mehrpanahi, Gholamhassan Payganeh, Mohammadreza Arbabtafti, Ali Hamidavi

    The use of multishaft industrial gas turbines is expanding in various industries because of variation in their structure, flexibility, and their appropriate power generation range. In this study, a semi-simplified black-box dynamic modeling has been done for the three-shaft gas turbine MGT-30. Modeling is done in such a way that all the important variables can be calculated and evaluated. One of the important parameters in dynamic modeling of gas turbine is the time lag relevant to the performance properties of sensors and actuators of the system. In this study, in order to measure the transfer function, physical and actual characteristics of the system were applied. Depending on the type of thermocouples (TCs) used, their activation time was eliminated using a lead compensator. In modeling of the system, the functions were related to the implementation of off-design conditions for compliance with the outputs of a real system model, and outputs were presented proportional to the rate and type of changes for each variable. Finally, validation was done by comparing the power-turbine generated power, exhaust gas temperatures downstream of low pressure (LP) turbine, and speeds of LP and high-pressure (HP) turbines with the real values of Qeshm turbogenerator power plant.


  • Dynamic modeling of an industrial gas turbine in loading and unloading conditions using a gray box method

    by Abdollah Mehrpanahi, Gholamhasan Payganeh, Mohammadreza Arbabtafti


  • Thermoeconomic investigation of coupling MED-TVC with a combined cycle power plant

    by Karim Maghsoudi, Majid Aliasghari, Abdollah Mehrpanahi

    Freshwater generation has always been one of the most important issues in human communities that coincided with population increase in different areas. Freshwater desalination technology can be one of the most effective methods in utilizing power plants heat recovery. Iran has a high potential to use this technology due to the shortage of fresh water resources on the one hand and several thermal power plants in the coastal areas of North and South on the other hand. In this study, according to the project of transferring Caspian Sea water to the central plateau of Iran and the necessity of water desalination before transferring, the studied topics are exergy destruction rate in different components of the cycle and rate of both profit and loss which results from coupling thermal desalination to Neka power plant. Results have shown that the maximum exergy destruction cost occurred in thermocompressor and then in condenser. Furthermore, if at least 2,000 cubic meters water per day, equivalent to 730,000 cubic meters in a year, was daily generated and sold with trade tariffs, power plant had acquired significant benefit of 28,732 ($/year), in addition to compensation for losses resulting from reduced electricity generation and if the maximum possible amount of 7,215 cubic meters per day equivalent to 2,633,457 cubic meters in a year of water was daily generated, the power plant had gained a significant benefit about 380,786.25 ($/year).