Keefe B. Manning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Keefe B. Manning has a total of 171 co-authors. Here are the top co-authors by number of shared publications:
Steven Deutsch
Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania
28 shared publicationsBryan C. Good
Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania
9 shared publicationsScott D. Simon
Department of Neurosurgery, Penn State College of Medicine , 700 HMC Crescent Road , Hershey, PA 17033
9 shared publicationsFrancesco Costanzo
Department of Engineering Science and Mechanics, The Pennsylvania State University , W315 Millennium Science Complex, 491 Pollock Road , University Park, PA 16802
7 shared publications- Brent A. Craven
Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland, 20993, UNITED STATES
6 shared publications Joshua O. Taylor
Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, USA; Applied Research Laboratory, The Pennsylvania State University, State College, PA, USA
6 shared publications
Latest Publications
- 28 July 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (9) , 1-23
An In Vitro Study of Embolus Migration in an Anatomical Cerebrovascular Model
Acute ischemic stroke (AIS) remains a driver of mortality and long-term impairment, with clinical outcomes depending strongly on the final lodging site of emboli within the cerebrovasculature. However, the physical mechanisms governing embolus migration and partitioning remain incompletely understood. Further, due to the paucity of experimental data in realistic anatomical models under pulsatile flow conditions, computational modeling of embolus migration in AIS remains largely unvalidated. The study objective is to acquire experimental benchmark data of embolus migration in an in vitro anatomical model comprising the aorta and the cerebrovasculature. Experiments are performed under pulsatile flow to quantify the migration of 480 rigid nylon spheres (1.58–4.76 mm) and 160 deformable blood emboli (2.53–3.95 mm). Emboli are injected into both Newtonian and non-Newtonian blood analogs to evaluate the influence of size, deformability, and fluid rheology. Results demonstrate an inverse relationship between embolus size and the propensity to migrate into the cerebrovasculature. Furthermore, when comparing emboli of similar dimensions, deformable blood clots exhibited consistently higher migration rates to the supra-aortic branches. While rheology slightly influences the migration of rigid spheres, it has a negligible effect on the partitioning of blood emboli. These findings suggest that embolus deformability plays a more dominant role than rheology in dictating whether realistic blood emboli migrate to the cerebral circulation. Consequently, to predict embolus trajectories and lodging sites in AIS, future in silico studies should incorporate fluid–structure interaction modeling to account for realistic clot deformability.
- 28 July 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (9) , 1-23
An In Vitro Study of Embolus Migration in an Anatomical Cerebrovascular Model
Acute ischemic stroke (AIS) remains a driver of mortality and long-term impairment, with clinical outcomes depending strongly on the final lodging site of emboli within the cerebrovasculature. However, the physical mechanisms governing embolus migration and partitioning remain incompletely understood. Further, due to the paucity of experimental data in realistic anatomical models under pulsatile flow conditions, computational modeling of embolus migration in AIS remains largely unvalidated. The study objective is to acquire experimental benchmark data of embolus migration in an in vitro anatomical model comprising the aorta and the cerebrovasculature. Experiments are performed under pulsatile flow to quantify the migration of 480 rigid nylon spheres (1.58–4.76 mm) and 160 deformable blood emboli (2.53–3.95 mm). Emboli are injected into both Newtonian and non-Newtonian blood analogs to evaluate the influence of size, deformability, and fluid rheology. Results demonstrate an inverse relationship between embolus size and the propensity to migrate into the cerebrovasculature. Furthermore, when comparing emboli of similar dimensions, deformable blood clots exhibited consistently higher migration rates to the supra-aortic branches. While rheology slightly influences the migration of rigid spheres, it has a negligible effect on the partitioning of blood emboli. These findings suggest that embolus deformability plays a more dominant role than rheology in dictating whether realistic blood emboli migrate to the cerebral circulation. Consequently, to predict embolus trajectories and lodging sites in AIS, future in silico studies should incorporate fluid–structure interaction modeling to account for realistic clot deformability.
- 10 July 2026
- Published by Elsevier in Biophysical Journal
- Vol. 125 (17) , 4662-4681
Red Blood Cell Deformation in a Microfluidic Sudden Expansion at Supraphysiological Strain Rates
- 10 July 2026
- Published by Elsevier in Biophysical Journal
- Vol. 125 (17) , 4662-4681
Red Blood Cell Deformation in a Microfluidic Sudden Expansion at Supraphysiological Strain Rates
- Open Access
- 25 June 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (10) , 2794-2808
Mechanical compaction alters microstructural and magnetic resonance imaging properties of acute ischemic stroke clots
Thrombolytic recanalization rates in acute ischemic stroke (AIS) patients remain low. Magnetic resonance susceptibility vessel sign has been correlated with reduced thrombolytic susceptibility. However, the driving mechanisms have not been clarified. In the present study, high-field magnetic resonance imaging is used to quantify relaxation rates and compaction of embolus analogs undergoing simulated AIS with varying pressures. Microscopy and perfusion tests are used to study the effect of compaction on clot microstructure and permeability, respectively. The results show that pressure dependent compaction alters clot microstructural characteristics and increases the R2 relaxation rate. Following compaction, the R2 in red blood cell (RBC) rich clots increases up to 224%, corresponding to a twofold increase in RBC volume fraction and polyhedrocyte formation. RBC and fibrin dominant clot permeabilities decrease by 78% and 97%, respectively, when compaction pressure increases 50 mmHg. Compacted RBC rich clots are the most likely to present with susceptibility vessel sign and have the lowest permeability. Our results suggest that increased clot constituent density due to compaction can lead to susceptibility vessel sign and elevated thrombolytic resistance by limiting thrombolytic perfusion. This is the first study to evaluate the clinical relevance of clot compaction during AIS using multiple imaging techniques.
- 25 June 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 46 (10) , 2794-2808
Open AccessMechanical compaction alters microstructural and magnetic resonance imaging properties of acute ischemic stroke clots
Thrombolytic recanalization rates in acute ischemic stroke (AIS) patients remain low. Magnetic resonance susceptibility vessel sign has been correlated with reduced thrombolytic susceptibility. However, the driving mechanisms have not been clarified. In the present study, high-field magnetic resonance imaging is used to quantify relaxation rates and compaction of embolus analogs undergoing simulated AIS with varying pressures. Microscopy and perfusion tests are used to study the effect of compaction on clot microstructure and permeability, respectively. The results show that pressure dependent compaction alters clot microstructural characteristics and increases the R2 relaxation rate. Following compaction, the R2 in red blood cell (RBC) rich clots increases up to 224%, corresponding to a twofold increase in RBC volume fraction and polyhedrocyte formation. RBC and fibrin dominant clot permeabilities decrease by 78% and 97%, respectively, when compaction pressure increases 50 mmHg. Compacted RBC rich clots are the most likely to present with susceptibility vessel sign and have the lowest permeability. Our results suggest that increased clot constituent density due to compaction can lead to susceptibility vessel sign and elevated thrombolytic resistance by limiting thrombolytic perfusion. This is the first study to evaluate the clinical relevance of clot compaction during AIS using multiple imaging techniques.
- Open Access
- 27 March 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (2) , 28
Computational fluid dynamics assessment of altered hemodynamics in the Circle of Willis during acute ischemic stroke and the impact of cerebral collateral development
Cerebral collateral assessment has become a common metric for treatment planning in acute ischemic stroke patients due to clinical evidence that well-developed collateral networks are correlated with favorable patient outcomes for reperfusion therapies, such as intravenous thrombolytics and mechanical thrombectomy. However, the mechanisms driving these outcome disparities are not well clarified. In the present study, a computational model is used to help clarify these mechanisms by assessing the Circle of Willis hemodynamics during middle cerebral artery occlusion with different levels of collateral development present. The results showed that middle cerebral artery occlusion causes up to a 30% increase in systemic mean arterial pressure, but the increase is less severe in cases with better collateralization, and cases with well-developed collaterals had up to a 66% lower pressure drop across the clot compared to the cases with poor collateral development. The ipsilateral collateral flow increased up to 20-fold following occlusion, which elevated blood flow and mixing distal to the occlusion. These results indicate that cerebral collaterals serve multiple functions that are important to consider in stroke cases. First, collaterals compensate for part of the lost blood flow to the affected brain region by permitting retrograde flow toward the distal end of the occluded vessel. Second, collaterals reduce the pressure forces on the clot, which can improve the susceptibility to reperfusion therapies. Overall, this study shows that we can leverage our unique computational model to better understand the importance of cerebral collateral circulation during stroke and the influence of collaterals on therapeutic outcomes.
- 27 March 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (2) , 28
Open AccessComputational fluid dynamics assessment of altered hemodynamics in the Circle of Willis during acute ischemic stroke and the impact of cerebral collateral development
Cerebral collateral assessment has become a common metric for treatment planning in acute ischemic stroke patients due to clinical evidence that well-developed collateral networks are correlated with favorable patient outcomes for reperfusion therapies, such as intravenous thrombolytics and mechanical thrombectomy. However, the mechanisms driving these outcome disparities are not well clarified. In the present study, a computational model is used to help clarify these mechanisms by assessing the Circle of Willis hemodynamics during middle cerebral artery occlusion with different levels of collateral development present. The results showed that middle cerebral artery occlusion causes up to a 30% increase in systemic mean arterial pressure, but the increase is less severe in cases with better collateralization, and cases with well-developed collaterals had up to a 66% lower pressure drop across the clot compared to the cases with poor collateral development. The ipsilateral collateral flow increased up to 20-fold following occlusion, which elevated blood flow and mixing distal to the occlusion. These results indicate that cerebral collaterals serve multiple functions that are important to consider in stroke cases. First, collaterals compensate for part of the lost blood flow to the affected brain region by permitting retrograde flow toward the distal end of the occluded vessel. Second, collaterals reduce the pressure forces on the clot, which can improve the susceptibility to reperfusion therapies. Overall, this study shows that we can leverage our unique computational model to better understand the importance of cerebral collateral circulation during stroke and the influence of collaterals on therapeutic outcomes.
- Open Access
- 29 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (5) , 1345-1364
Modeling Red Blood Cell Deformation at Supraphysiological Strain Rates Using a Droplet Framework
Purpose: Hemolysis remains a concern in mechanical circulatory support devices (MCSDs). Capturing flow-induced red blood cell (RBC) deformation is important to improve these technologies. Deformation models that are feasible for macroscale MCSD flows have not been calibrated with human RBC deformation data across multiple conditions. The purpose of this study is to modify and test a droplet deformation model that is applicable for MCSD flows for predicting human RBC deformation in silico . Methods: In vitro human RBC deformation is studied in microfluidic flows in two suspension viscosities (2.05 and 4.17 cP) at MCSD relevant strain rates (5,000 – 200,000 s -1 in shear flow; 330 – 13,160 s -1 in extensional flow). Modifications are made to the deformation model’s constitutive parameters to represent the observed RBC deformation in silico . Results: The calibrated model reproduces the unique RBC deformation behaviors observed in shear and extensional flows across a range of conditions. In silico shear deformation index data have mean absolute error (MAE) ≤ 0.15 compared to in vitro results for both viscosity conditions from 5,000 to 200,000 s -1 . Peak in silico extensional deformation data demonstrate MAE ≤ 0.11 compared to our in vitro results for both viscosity conditions from 670 to 1,300 s -1 , while MAE is higher (up to 0.17) for conditions at 330 s -1 . Conclusion: The model adaptations successfully produce accurate RBC deformation results at MCSD relevant strain rates for two flow types and two suspension viscosities. The strengths of the model are in relatively high velocity gradient magnitudes and/or suspension viscosities where RBCs emulate liquid droplets.
- 29 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (5) , 1345-1364
Open AccessModeling Red Blood Cell Deformation at Supraphysiological Strain Rates Using a Droplet Framework
Purpose: Hemolysis remains a concern in mechanical circulatory support devices (MCSDs). Capturing flow-induced red blood cell (RBC) deformation is important to improve these technologies. Deformation models that are feasible for macroscale MCSD flows have not been calibrated with human RBC deformation data across multiple conditions. The purpose of this study is to modify and test a droplet deformation model that is applicable for MCSD flows for predicting human RBC deformation in silico . Methods: In vitro human RBC deformation is studied in microfluidic flows in two suspension viscosities (2.05 and 4.17 cP) at MCSD relevant strain rates (5,000 – 200,000 s -1 in shear flow; 330 – 13,160 s -1 in extensional flow). Modifications are made to the deformation model’s constitutive parameters to represent the observed RBC deformation in silico . Results: The calibrated model reproduces the unique RBC deformation behaviors observed in shear and extensional flows across a range of conditions. In silico shear deformation index data have mean absolute error (MAE) ≤ 0.15 compared to in vitro results for both viscosity conditions from 5,000 to 200,000 s -1 . Peak in silico extensional deformation data demonstrate MAE ≤ 0.11 compared to our in vitro results for both viscosity conditions from 670 to 1,300 s -1 , while MAE is higher (up to 0.17) for conditions at 330 s -1 . Conclusion: The model adaptations successfully produce accurate RBC deformation results at MCSD relevant strain rates for two flow types and two suspension viscosities. The strengths of the model are in relatively high velocity gradient magnitudes and/or suspension viscosities where RBCs emulate liquid droplets.
- Open Access
- 16 December 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 17 (1) , 76-84
Computational Modeling of Flow in an in Vitro Cerebrovascular Model Under Pulsatile Conditions with Experimental Validation
Purpose: Computational fluid dynamics (CFD) has been widely used to understand various cardiovascular diseases such as acute ischemic stroke (AIS), which occurs when a blood clot lodges in the cerebrovasculature and obstructs blood flow that may lead to brain damage or death. Compared with medical imaging, CFD can predict hemodynamics and clot migration, which are crucial in better understanding the biomechanics of AIS. To rely on computational modeling, however, the simulations need to be validated by comparing with experiments Methods: In this study, we develop an in vitro experimental model of pulsatile flow in the aorta and cerebrovasculature. The model was filled with a blood analog fluid and pulsatile flow was driven by a piston pump to generate realistic physiological flow conditions. Experimental measurements of the time-varying pressure and flow rate were acquired and are used to validate corresponding CFD simulations Results: CFD predictions of the time-averaged pressure at the outlets are shown to be within 8% of the experimental measurements, while the time-averaged flow rate is within 1%. Conclusions: This work demonstrates a promising capability for modeling embolus migration and lodging in the brain. Future work will validate simulations of clot migration that may be used to better understand AIS biomechanics and treatment options.
- 16 December 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 17 (1) , 76-84
Open AccessComputational Modeling of Flow in an in Vitro Cerebrovascular Model Under Pulsatile Conditions with Experimental Validation
Purpose: Computational fluid dynamics (CFD) has been widely used to understand various cardiovascular diseases such as acute ischemic stroke (AIS), which occurs when a blood clot lodges in the cerebrovasculature and obstructs blood flow that may lead to brain damage or death. Compared with medical imaging, CFD can predict hemodynamics and clot migration, which are crucial in better understanding the biomechanics of AIS. To rely on computational modeling, however, the simulations need to be validated by comparing with experiments Methods: In this study, we develop an in vitro experimental model of pulsatile flow in the aorta and cerebrovasculature. The model was filled with a blood analog fluid and pulsatile flow was driven by a piston pump to generate realistic physiological flow conditions. Experimental measurements of the time-varying pressure and flow rate were acquired and are used to validate corresponding CFD simulations Results: CFD predictions of the time-averaged pressure at the outlets are shown to be within 8% of the experimental measurements, while the time-averaged flow rate is within 1%. Conclusions: This work demonstrates a promising capability for modeling embolus migration and lodging in the brain. Future work will validate simulations of clot migration that may be used to better understand AIS biomechanics and treatment options.
- Open Access
- 3 October 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (10) , e70094
Characterization of the In Situ Stress State of Blood Clots in Ischemic Stroke: The Effect of Initial Conditions and Arterial Interaction
Ischemic stroke, caused by a blood clot lodging in cerebral vasculature, is a leading cause of death worldwide. The mechanics of vessel occlusion and the influence of residual stress on thrombectomy outcomes remain poorly understood. Most computational studies neglect arterial residual stress and the deformation a clot undergoes as it lodges, both of which elevate system stresses. Here, we introduce a method to simulate the initial state of a clot lodged in an idealized artery with residual stress. In this study, the artery is formulated as two concentric right cylinders with fibers embedded in an isotropic mesh, with a pre‐deformation used to incorporate residual stress. A base equilibrium state of an elastic clot is simulated in continuous contact with the arterial wall. The opening angle of the artery, un‐lodged‐to‐lodged dimensional ratios, and stiffness of the clot are varied in parametric sweeps to characterize the traction forces of the clot into the arterial wall. An aspiration pressure is applied to the proximal end of the clot to determine the pressures necessary to begin tensile detachment of the clot. As the artery opening angle increased, removal aspiration pressures increased, while the pressures decreased with increasing artery fiber orientation. The stress‐free‐to‐lodged length ratio of the clot influenced the removal aspiration pressure, with pressures increasing nearly a thousand‐fold with increased ratio. By incorporating different factors that contribute to the stress state of the system, this study provides a library of realistic initial conditions for simulating aspiration thrombectomy and validating new surgical techniques.
- 3 October 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (10) , e70094
Open AccessCharacterization of the In Situ Stress State of Blood Clots in Ischemic Stroke: The Effect of Initial Conditions and Arterial Interaction
Ischemic stroke, caused by a blood clot lodging in cerebral vasculature, is a leading cause of death worldwide. The mechanics of vessel occlusion and the influence of residual stress on thrombectomy outcomes remain poorly understood. Most computational studies neglect arterial residual stress and the deformation a clot undergoes as it lodges, both of which elevate system stresses. Here, we introduce a method to simulate the initial state of a clot lodged in an idealized artery with residual stress. In this study, the artery is formulated as two concentric right cylinders with fibers embedded in an isotropic mesh, with a pre‐deformation used to incorporate residual stress. A base equilibrium state of an elastic clot is simulated in continuous contact with the arterial wall. The opening angle of the artery, un‐lodged‐to‐lodged dimensional ratios, and stiffness of the clot are varied in parametric sweeps to characterize the traction forces of the clot into the arterial wall. An aspiration pressure is applied to the proximal end of the clot to determine the pressures necessary to begin tensile detachment of the clot. As the artery opening angle increased, removal aspiration pressures increased, while the pressures decreased with increasing artery fiber orientation. The stress‐free‐to‐lodged length ratio of the clot influenced the removal aspiration pressure, with pressures increasing nearly a thousand‐fold with increased ratio. By incorporating different factors that contribute to the stress state of the system, this study provides a library of realistic initial conditions for simulating aspiration thrombectomy and validating new surgical techniques.
- Open Access
- 16 August 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
Development, characterization, and curve fitting of rate-dependent models of calcified cerebral embolus analogs for acute ischemic stroke
Acute ischemic stroke (AIS) is a leading cause of death worldwide. In recent years, several studies have characterized the material properties of clot types that were removed from stroke patients, showing a highly nonlinear, asymmetric behavior in compression and tension. However, little is still known about the clot phenotype underlying complications in endovascular thrombectomy (EVT). In this study, we propose a spectrum of clot surrogates for highly stiff, red blood cell-rich, aged, calcified clots that may underpin the outcomes of AIS procedures, often called ‘hyperdense middle cerebral artery signs’ by clinicians. This study aims to characterize the high-strain, rate-dependent mechanical properties of a broad range of aged and calcified clot analogs. Blood from healthy donors was used to form aged and calcified clots, which were subjected to rate-dependent uniaxial testing and structural analyses. A method for curve fitting standard linear solids with multiple hyperelastic elements is considered, and a subsequent procedure is outlined for fitting rate-dependent data. High-strain clot analog peak stresses and moduli are on the same order of magnitude as previous studies, with the hypercalcified clots nearly an order of magnitude stiffer than previously recorded. The calcification was shown to be time dependent, as the longer the clots incubated in the calcium solutions, the stiffer they became. SEM images show drastic changes in clot morphology, with mineral nucleation evident around all components of the clot. The curve fitting produced parameters for a host of models that can be used in numerical implementation. The authors note that when curve fitting, energy state of the system should be taken into consideration, in addition to the minimization of the relative error. We demonstrate a wide spectrum of clot properties that are captured well by rate-dependent models for the full dataset, the compressive data, and the tensile data. In this study, we provide a method for creating and characterizing hypercalcified clot analogs as surrogates for the clot phenotype underlying EVT complications. The library of clot properties reported here can be used in numerical simulations, with careful considerations of the curve fitting methods that are employed. These data highlight the need for further investigation into this clot phenotype, which may be related to the subset of AIS patients where clots are unable to be removed.
- 16 August 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
Open AccessDevelopment, characterization, and curve fitting of rate-dependent models of calcified cerebral embolus analogs for acute ischemic stroke
Acute ischemic stroke (AIS) is a leading cause of death worldwide. In recent years, several studies have characterized the material properties of clot types that were removed from stroke patients, showing a highly nonlinear, asymmetric behavior in compression and tension. However, little is still known about the clot phenotype underlying complications in endovascular thrombectomy (EVT). In this study, we propose a spectrum of clot surrogates for highly stiff, red blood cell-rich, aged, calcified clots that may underpin the outcomes of AIS procedures, often called ‘hyperdense middle cerebral artery signs’ by clinicians. This study aims to characterize the high-strain, rate-dependent mechanical properties of a broad range of aged and calcified clot analogs. Blood from healthy donors was used to form aged and calcified clots, which were subjected to rate-dependent uniaxial testing and structural analyses. A method for curve fitting standard linear solids with multiple hyperelastic elements is considered, and a subsequent procedure is outlined for fitting rate-dependent data. High-strain clot analog peak stresses and moduli are on the same order of magnitude as previous studies, with the hypercalcified clots nearly an order of magnitude stiffer than previously recorded. The calcification was shown to be time dependent, as the longer the clots incubated in the calcium solutions, the stiffer they became. SEM images show drastic changes in clot morphology, with mineral nucleation evident around all components of the clot. The curve fitting produced parameters for a host of models that can be used in numerical implementation. The authors note that when curve fitting, energy state of the system should be taken into consideration, in addition to the minimization of the relative error. We demonstrate a wide spectrum of clot properties that are captured well by rate-dependent models for the full dataset, the compressive data, and the tensile data. In this study, we provide a method for creating and characterizing hypercalcified clot analogs as surrogates for the clot phenotype underlying EVT complications. The library of clot properties reported here can be used in numerical simulations, with careful considerations of the curve fitting methods that are employed. These data highlight the need for further investigation into this clot phenotype, which may be related to the subset of AIS patients where clots are unable to be removed.
- Open Access
- 3 January 2025
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 6, 1533412
Corrigendum: Modeling flow in an in vitro anatomical cerebrovascular model with experimental validation
In the published article, there was an error in Figure 3b as published. The simulation was based on an incorrect scale and the values have been updated. The corrected Figure 3b and its caption appear below. In the published article, there was an error in Figure 5 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected Figure 5 and its caption appear below. In the published article, there was an error in Table 2 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected Table 2 and its caption appear below.In In the published article, there was an error in Table 3 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected
- 3 January 2025
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 6, 1533412
Open AccessCorrigendum: Modeling flow in an in vitro anatomical cerebrovascular model with experimental validation
In the published article, there was an error in Figure 3b as published. The simulation was based on an incorrect scale and the values have been updated. The corrected Figure 3b and its caption appear below. In the published article, there was an error in Figure 5 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected Figure 5 and its caption appear below. In the published article, there was an error in Table 2 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected Table 2 and its caption appear below.In In the published article, there was an error in Table 3 as published. The simulation was conducted using an incorrect scale and these values have been revised. The corrected
- 2 December 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (1) , 116-137
Fluid Dynamic and in Vitro Blood Study to Understand Catheter-Related Thrombosis
Purpose Central venous catheters (CVCs) provide a direct route to the venous circulation but are prone to catheter-related thrombosis (CRT). A known CRT risk factor is a high catheter-to-vein ratio (CVR), or a large catheter diameter with respect to the indwelling vein size. In this study, the CVR’s effect on CVC hemodynamics and its impact on CRT is investigated with in vitro and in silico experiments. Methods An in vitro flow loop is used to characterize the hemodynamics around CVCs using particle image velocimetry. In addition, CRT is investigated using an in vitro flow loop with human blood and clinical catheters. The wall shear rate of flow around the CVC is computed numerically. CVRs of 0.20, 0.33, and 0.49 and Reynolds numbers of 200, 800, and 1300 are evaluated. No flow is used through CVC lumens to model chronic indwelling catheters. Results Results show CVR ≥ 0.33 promotes platelet-rich clot growth at the device tip and at an increased rate compared to lower CVR cases. A high wall shear rate gradient on the CVC tip and an extended wake distal to the tip exists for higher CVR cases, promoting the aggregation of platelets and subsequent stagnation for clot formation. Further, the combination of the CVR and Reynolds number are crucial to CRT potential, not the CVR alone. Specifically, thrombosis risk is increased with low (stasis driven) and/or high (platelet activation driven) flow conditions, with the CVR and CVC’s geometry playing an additional role in promoting fluid mechanic driven thrombus development. A high CVR (≥ 0.33) and high flow condition (≥ 1300) results in the highest risk for clot growth at the tip of the device; other locations of the device are at risk for thrombus development in lower flow conditions, regardless of the CVR. The importance of the device geometry and flow in promoting thrombus and fibrin sheath formation is also shown for the device investigated. Conclusions This work demonstrates that the CVR, flow, and device geometry affect CRT. For clinical cases with CVR ≥ 0.33 and/or Re ≥ 1300, the device tip may be monitored more consistently for clot formation. Thrombosis risks remain on the entire catheter, regardless of the flow condition, for a CVR = 0.49. Device placement should be chosen carefully with respect to the combination of the Reynolds number and CVR. Further study is needed on the effect of catheterization to confirm these findings.
- 2 December 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (1) , 116-137
Fluid Dynamic and in Vitro Blood Study to Understand Catheter-Related Thrombosis
Purpose Central venous catheters (CVCs) provide a direct route to the venous circulation but are prone to catheter-related thrombosis (CRT). A known CRT risk factor is a high catheter-to-vein ratio (CVR), or a large catheter diameter with respect to the indwelling vein size. In this study, the CVR’s effect on CVC hemodynamics and its impact on CRT is investigated with in vitro and in silico experiments. Methods An in vitro flow loop is used to characterize the hemodynamics around CVCs using particle image velocimetry. In addition, CRT is investigated using an in vitro flow loop with human blood and clinical catheters. The wall shear rate of flow around the CVC is computed numerically. CVRs of 0.20, 0.33, and 0.49 and Reynolds numbers of 200, 800, and 1300 are evaluated. No flow is used through CVC lumens to model chronic indwelling catheters. Results Results show CVR ≥ 0.33 promotes platelet-rich clot growth at the device tip and at an increased rate compared to lower CVR cases. A high wall shear rate gradient on the CVC tip and an extended wake distal to the tip exists for higher CVR cases, promoting the aggregation of platelets and subsequent stagnation for clot formation. Further, the combination of the CVR and Reynolds number are crucial to CRT potential, not the CVR alone. Specifically, thrombosis risk is increased with low (stasis driven) and/or high (platelet activation driven) flow conditions, with the CVR and CVC’s geometry playing an additional role in promoting fluid mechanic driven thrombus development. A high CVR (≥ 0.33) and high flow condition (≥ 1300) results in the highest risk for clot growth at the tip of the device; other locations of the device are at risk for thrombus development in lower flow conditions, regardless of the CVR. The importance of the device geometry and flow in promoting thrombus and fibrin sheath formation is also shown for the device investigated. Conclusions This work demonstrates that the CVR, flow, and device geometry affect CRT. For clinical cases with CVR ≥ 0.33 and/or Re ≥ 1300, the device tip may be monitored more consistently for clot formation. Thrombosis risks remain on the entire catheter, regardless of the flow condition, for a CVR = 0.49. Device placement should be chosen carefully with respect to the combination of the Reynolds number and CVR. Further study is needed on the effect of catheterization to confirm these findings.