Markus Groissböck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Markus Groissböck has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Michael Stadler
Lawrence Berkeley National Laboratory, Berkeley, CA, USA
7 shared publications C. Marnay
2 shared publicationsG. Cardoso
2 shared publications- Hafiz Muhammad Afzal Siddiqui
Department of Mathematics, COMSATS University Islamabad, Lahore Campus, Pakistan
2 shared publications A. Alvarez
1 shared publicationA. Gusmao
Saudi Aramco (PSRD/PSPD), Dhahran, Kingdom of Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 1 November 2020
- Published by Elsevier in Applied Energy
- Vol. 277
Impact of renewable resource quality on security of supply with high shares of renewable energies
- 1 November 2020
- Published by Elsevier in Applied Energy
- Vol. 277
Open AccessImpact of renewable resource quality on security of supply with high shares of renewable energies
- Open Access
- 1 November 2020
- Published by Elsevier in Renewable Energy
- Vol. 160, 1396-1407
Impact of spatial renewable resource quality on optimum renewable expansion
- 1 November 2020
- Published by Elsevier in Renewable Energy
- Vol. 160, 1396-1407
Open AccessImpact of spatial renewable resource quality on optimum renewable expansion
- 1 March 2019
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 102, 234-248
Are open source energy system optimization tools mature enough for serious use?
- 1 March 2019
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 102, 234-248
Are open source energy system optimization tools mature enough for serious use?
- Open Access
Reliability constrained least-cost generation expansion planning: an isolated mini-grid in KSA
Renewable energy sources (RES) are getting closer to grid parity within interconnected systems while their use in isolated and remote areas is already cost competitive with conventional generation. In mini-grids, isolated and far from the grid, the economics of different technology options (e.g. pure solar photovoltaic (PV), wind, concentrated solar power (CSP), and open cycle gas turbine (OCGT)) with different amounts of added capacity is assessed to allow the peak demand to increase by 5 MW (or 5%) and 10 MW (or 10%). This assessment is based on keeping the system reliability (measured in loss of load expectation, LOLE) at the same level as it was before the addition of conventional and renewable generators. An effective load carrying capability (ELCC) increase by 5 MW (or 5%) can be realized by adding a 5 MW OCGT or 10 MW PV and 10 MW wind. An ELCC increase of 10 MW (or 10%) requires either 11 MW OCGT or 7.2 MW OCGT, 2.7 MW PV, and 8.1 MW wind. In both cases, the solution with RES has 8% and 4% lower annual costs than the OCGT only solution (assuming crude costs of $40/barrel). From an economic and system reliability perspective, systems with low growth rates (5%) still need to incorporate conventional generation.
Open AccessReliability constrained least-cost generation expansion planning: an isolated mini-grid in KSA
Renewable energy sources (RES) are getting closer to grid parity within interconnected systems while their use in isolated and remote areas is already cost competitive with conventional generation. In mini-grids, isolated and far from the grid, the economics of different technology options (e.g. pure solar photovoltaic (PV), wind, concentrated solar power (CSP), and open cycle gas turbine (OCGT)) with different amounts of added capacity is assessed to allow the peak demand to increase by 5 MW (or 5%) and 10 MW (or 10%). This assessment is based on keeping the system reliability (measured in loss of load expectation, LOLE) at the same level as it was before the addition of conventional and renewable generators. An effective load carrying capability (ELCC) increase by 5 MW (or 5%) can be realized by adding a 5 MW OCGT or 10 MW PV and 10 MW wind. An ELCC increase of 10 MW (or 10%) requires either 11 MW OCGT or 7.2 MW OCGT, 2.7 MW PV, and 8.1 MW wind. In both cases, the solution with RES has 8% and 4% lower annual costs than the OCGT only solution (assuming crude costs of $40/barrel). From an economic and system reliability perspective, systems with low growth rates (5%) still need to incorporate conventional generation.
- 1 March 2016
- Published by Elsevier in Applied Energy
- Vol. 165, 548-558
An analysis of the power market in Saudi Arabia: Retrospective cost and environmental optimization
- 1 March 2016
- Published by Elsevier in Applied Energy
- Vol. 165, 548-558
An analysis of the power market in Saudi Arabia: Retrospective cost and environmental optimization
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Capacity value of photovoltaic and wind power plants in an isolated Mini-grid in the Kingdom of Saudi Arabia
Solar Photovoltaic (PV) and Wind power plants are becoming increasingly cost competitive when compared with conventional thermal power plants and in the not far future may set the ceiling price of electricity in many markets. The Kingdom of Saudi Arabia (KSA) is internationally known for its hydrocarbon reserves but is less recognized for its renewable energy resources, especially wind energy. These renewable energy resources, although known as Variable Energy Resources (VERs), can be efficiently integrated into conventional power systems to provide stable and reliable electricity, whether for national power systems or for isolated Mini-grid power systems in KSA. Traditional capacity measures as Capacity Factor (CF) and Reserve Margin (RM) are not able to deal with the intermittency of Wind and PV power plants. Statistical and probabilistic measures coming from System's Adequacy methodology as Effective Load Carrying Capability (ELCC), Equivalent Firm Capacity (EFC) or Equivalent Conventional Power Plant (ECPP) are available to assess the capacity value of VERs. All of these methods are based on Generation Adequacy where VER is added to conventional power plants to fulfil the load. A case study was completed for a Mini-grid within the Saudi Electric Company's (SEC) Southern Operating Area (SOA) where the Loss of Load Probability (LOLP) for the conventional thermal power plant was estimated and the addition of VER is assessed by using ELCC. Based on the available load data and VER profiles for PV a Capacity Credit of 51.8% was estimated, declining at a rate of 2.2% per MWp of additional installed capacity. The ELCC for Wind was estimated to be 19.4%, declining at a rate of 1.4% per MW of additional installed capacity. It was also found that using VER improves the system reliability in terms of Loss of Load Expectation (LOLE). While excessive VER production does not impact LOLE it does impact the economics. A penetration of up to 25% wind or 30% PV does not result in curtailing VER production.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Capacity value of photovoltaic and wind power plants in an isolated Mini-grid in the Kingdom of Saudi Arabia
Solar Photovoltaic (PV) and Wind power plants are becoming increasingly cost competitive when compared with conventional thermal power plants and in the not far future may set the ceiling price of electricity in many markets. The Kingdom of Saudi Arabia (KSA) is internationally known for its hydrocarbon reserves but is less recognized for its renewable energy resources, especially wind energy. These renewable energy resources, although known as Variable Energy Resources (VERs), can be efficiently integrated into conventional power systems to provide stable and reliable electricity, whether for national power systems or for isolated Mini-grid power systems in KSA. Traditional capacity measures as Capacity Factor (CF) and Reserve Margin (RM) are not able to deal with the intermittency of Wind and PV power plants. Statistical and probabilistic measures coming from System's Adequacy methodology as Effective Load Carrying Capability (ELCC), Equivalent Firm Capacity (EFC) or Equivalent Conventional Power Plant (ECPP) are available to assess the capacity value of VERs. All of these methods are based on Generation Adequacy where VER is added to conventional power plants to fulfil the load. A case study was completed for a Mini-grid within the Saudi Electric Company's (SEC) Southern Operating Area (SOA) where the Loss of Load Probability (LOLP) for the conventional thermal power plant was estimated and the addition of VER is assessed by using ELCC. Based on the available load data and VER profiles for PV a Capacity Credit of 51.8% was estimated, declining at a rate of 2.2% per MWp of additional installed capacity. The ELCC for Wind was estimated to be 19.4%, declining at a rate of 1.4% per MW of additional installed capacity. It was also found that using VER improves the system reliability in terms of Loss of Load Expectation (LOLE). While excessive VER production does not impact LOLE it does impact the economics. A penetration of up to 25% wind or 30% PV does not result in curtailing VER production.
- 1 January 2015
- Published by Elsevier in Applied Energy
- Vol. 137, 782-792
Modeling of thermal storage systems in MILP distributed energy resource models
- 1 January 2015
- Published by Elsevier in Applied Energy
- Vol. 137, 782-792
Modeling of thermal storage systems in MILP distributed energy resource models
- 1 November 2014
- Published by Elsevier in Applied Energy
- Vol. 132, 557-567
Optimizing Distributed Energy Resources and building retrofits with the strategic DER-CAModel
- 1 November 2014
- Published by Elsevier in Applied Energy
- Vol. 132, 557-567
Optimizing Distributed Energy Resources and building retrofits with the strategic DER-CAModel
- 1 October 2014
- Published by Elsevier in Energy and Buildings
- Vol. 81, 416-423
A strategic optimization model for energy systems planning
- 1 October 2014
- Published by Elsevier in Energy and Buildings
- Vol. 81, 416-423
A strategic optimization model for energy systems planning
- 1 March 2014
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 140 (1)
Optimizing Building Energy Operations via Dynamic Zonal Temperature Settings
- 1 March 2014
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 140 (1)
Optimizing Building Energy Operations via Dynamic Zonal Temperature Settings